west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "一致性" 21 results
  • A multi-parameter resting-state functional magnetic resonance imaging study of brain intrinsic activity in attention deficit hyperactivity disorder children

    A great number of studies have demonstrated functional abnormalities in children with attention-deficit/hyperactivity disorder (ADHD), although conflicting results have also been reported. And few studies analyzed homotopic functional connectivity between hemispheres. In this study, resting-state functional magnetic resonance imaging (MRI) data were recorded from 45 medication-naïve ADHD children and 26 healthy controls. The regional homogeneity (ReHo), degree centrality (DC) and voxel-mirrored homotopic connectivity (VMHC) values were compared between the two groups to depict the intrinsic brain activities. We found that ADHD children exhibited significantly lower ReHo and DC values in the right middle frontal gyrus and the two values correlated with each other; moreover, lower VMHC values were found in the bilateral occipital lobes of ADHD children, which was negatively related with anxiety scores of Conners' Parent Rating Scale (CPRS-R) and positively related with completed categories of Wisconsin Card Sorting Test (WCST). Our results might suggest that less spontaneous neuronal activities of the right middle frontal gyrus and the bilateral occipital lobes in ADHD children.

    Release date:2018-08-23 03:47 Export PDF Favorites Scan
  • Research on classification of benign and malignant lung nodules based on three-dimensional multi-view squeeze-and-excitation convolutional neural network

    Lung cancer is the most threatening tumor disease to human health. Early detection is crucial to improve the survival rate and recovery rate of lung cancer patients. Existing methods use the two-dimensional multi-view framework to learn lung nodules features and simply integrate multi-view features to achieve the classification of benign and malignant lung nodules. However, these methods suffer from the problems of not capturing the spatial features effectively and ignoring the variability of multi-views. Therefore, this paper proposes a three-dimensional (3D) multi-view convolutional neural network (MVCNN) framework. To further solve the problem of different views in the multi-view model, a 3D multi-view squeeze-and-excitation convolution neural network (MVSECNN) model is constructed by introducing the squeeze-and-excitation (SE) module in the feature fusion stage. Finally, statistical methods are used to analyze model predictions and doctor annotations. In the independent test set, the classification accuracy and sensitivity of the model were 96.04% and 98.59% respectively, which were higher than other state-of-the-art methods. The consistency score between the predictions of the model and the pathological diagnosis results was 0.948, which is significantly higher than that between the doctor annotations and the pathological diagnosis results. The methods presented in this paper can effectively learn the spatial heterogeneity of lung nodules and solve the problem of multi-view differences. At the same time, the classification of benign and malignant lung nodules can be achieved, which is of great significance for assisting doctors in clinical diagnosis.

    Release date:2022-08-22 03:12 Export PDF Favorites Scan
  • Analysis of Abnormal Muscular Coupling During Rehabilitation after Stroke

    For the questions of deeply researching abnormal neuromuscular coupling and better evaluating motor function of stroke patients with motor dysfunction, an effective intermuscular coherence analysis method and index are studied to explore the neuromuscular oscillation and the pathomechanism of motor dysfunction, based on which an assessment standard of muscle function is established. Firstly, the contrastive analysis about the intermuscular coherence of antagonistic muscle of affected and intact upper limbs of stroke patients was conducted. Secondly, a significant indicator of Fisher's Z-transformed coherence significant indicator was defined to quantitatively describe the coupling differences in certain functional frequency domain between surface electromyogram (sEMG) of affected and intact sides. Further more, the relationship between intermuscular coherence and motor task was studied. Through the analysis of intermuscular coherence during elbow flexion-extension of affected and intact sides, we found that the intermuscular coherence was associated with motor task and the stroke patients exhibited significantly lower beta-band intermuscular coherence in performing the task with their affected upper limbs. More conclusion can be drawn that beta-band intermuscular coherence has been found concerned with Fugle-Meyer scale, which indicates that beta-band intermuscular coherence could be an index assisting in evaluating motor function of patients.

    Release date: Export PDF Favorites Scan
  • An overview of the COSMIN-RoB checklist and the interpretation of it in evaluating the risk of bias of studies on internal structure

    Measurement properties studies of patient-reported outcome measures (PROMs) aims to validate the measurement properties of PROMs. In the process of designing and statistical analysis of these measurement properties studies, bias will occur if there are any defects, which will affect the quality of PROMs. Therefore, the COSMIN (consensus-based standards for the selection of health measurement instruments) team has developed the COSMIN risk of bias (COSMIN-RoB) checklist to evaluate risk of bias of studies on measurement properties of PROMs. The checklist can be used to develop systematic reviews of PROMs measurement properties, and for PROMs developers, it can also be used to guide the research design in the measurement tool development process for reducing bias. At present, similar assessment tools are lacking in China. Therefore, this article aims to introduce the primary contents of COSMIN-RoB checklist and to interpret how to evaluate risk of bias of the internal structure studies of PROMs with examples.

    Release date:2020-11-19 02:32 Export PDF Favorites Scan
  • Study of Functional Magnetic Resonance Imaging at Resting State for Patients in Sub-health Status

    This study sought to reveal the difference of brain functions at resting-state between subjects with sub-health and normal controls by using the functional magnetic resonance imaging (fMRI) technology. Resting-state fMRI scans were performed on 24 subjects of sub-health and on 24 healthy controls with gender, age and education matched with the sub-health persons. Compared to the healthy controls, the sub-health group showed significantly higher regional homogeneity (ReHo) in the left post-central gyrus and the right post-central gyrus. On the other hand, the sub-health group showed significantly lower ReHo in the left superior frontal gyrus, in the right anterior cingulated cortex and ventra anterior cingulate gyrus, in the left dorsolateral frontal gyrus, and in the right middle temporal gyrus. The Significant difference in ReHo suggests that thebsub-health persons have abnormalities in certain brain regions. It is proved that its specific action and meaning deserves further assessment.

    Release date: Export PDF Favorites Scan
  • A Study of Resting State Functional Magnetic Resonance Imaging in Patients with Posttraumatic Stress Disorder Using Regional Homogeneity

    目的 利用局部一致性(ReHo)方法探测创伤后应激障碍(PTSD)患者在静息状态下是否存在着大脑功能异常。 方法 2010年5月-7月对18例未经治疗的地震PTSD患者和19例同样经历地震但未患PTSD的对照者进行了静息态功能磁共振成像(Rs-fMRI) 扫描。应用ReHo方法处理Rs-fMRI数据,得出PTSD患者的异常脑区,并将患者存在组间差异的脑区ReHo值与临床用PTSD诊断量表(CAPS)、汉密尔顿抑郁量表(HAMD)和汉密尔顿焦虑量表(HAMA)分别进行相关分析。 结果 ① PTSD组ReHo显著增加的脑区包括右侧颞下回、楔前叶、顶下叶、中扣带回,左侧枕中回以及左/右侧后扣带回;ReHo显著降低的脑区包括左侧海马和左/右侧腹侧前扣带回。② 异常脑区中后扣带回和右侧中扣带回ReHo与HAMD呈负相关(中扣带回r=?0.575,P=0.012;右侧后扣带回:r=?0.507,P=0.032),其余脑区ReHo与临床指标无明显相关性(P>0.05),左侧海马与CAPS的相关性相对其他脑区较大(r=?0.430,P=0.075)。 结论 PTSD患者在静息状态下即存在着局部脑功能活动的降低和增加,ReHo方法可能有助于研究PTSD患者静息状态脑活动。

    Release date:2016-09-08 09:14 Export PDF Favorites Scan
  • Evaluation Method for Medical Literature Applicability

    Objective To investigate an evaluation method of medical literature applicability to clinical work, and provide a convenient way for physicians to search for the best evidence. Methods Delphi method was used to choose appropriate evaluating indexes, analytic hierarchy process was performed to determine the weighing of each index, and the formula to calculate medical literature applicability was formed. The practicability of this formula was evaluated by consistency checking between the formula’s results and experts’ opinions on literature applicability. Results Five evaluating indexes were determined, including literature’s publishing year (X1), whether the target questions were covered (X2), sample size (X3), trial category (X4), and journal level (X5). The formula to calculate medical literature applicability was Y=3.93 X1+11.78 X2+14.83 X3+44.53 X4+24.93 X5. The result of consistency checking showed that the formula’s results were highly consistent with experts’ opinions (Kappa=0.75, P<0.001). Conclusion The applicability formula is a valuable tool to evaluate medical literature applicability.

    Release date:2016-08-30 05:45 Export PDF Favorites Scan
  • A gait signal acquisition and parameter characterization method based on foot pressure detection combined with Azure Kinect system

    The gait acquisition system can be used for gait analysis. The traditional wearable gait acquisition system will lead to large errors in gait parameters due to different wearing positions of sensors. The gait acquisition system based on marker method is expensive and needs to be used by combining with the force measurement system under the guidance of rehabilitation doctors. Due to the complex operation, it is inconvenient for clinical application. In this paper, a gait signal acquisition system that combines foot pressure detection and Azure Kinect system is designed. Fifteen subjects are organized to participate in gait test, and relevant data are collected. The calculation method of gait spatiotemporal parameters and joint angle parameters is proposed, and the consistency analysis and error analysis of the gait parameters of proposed system and camera marking method are carried out. The results show that the parameters obtained by the two systems have good consistency (Pearson correlation coefficient r ≥ 0.9, P < 0.05) and have small error (root mean square error of gait parameters is less than 0.1, root mean square error of joint angle parameters is less than 6). In conclusion, the gait acquisition system and its parameter extraction method proposed in this paper can provide reliable data acquisition results as a theoretical basis for gait feature analysis in clinical medicine.

    Release date:2023-06-25 02:49 Export PDF Favorites Scan
  • Interobserver agreement of international classification of myopic maculopathy

    ObjectiveTo observe the interobserver agreement of classification of macular degeneration in severe pathological myopia (PM) by ophthalmologists with different clinical experience. MethodsA retrospective study. From January 2019 to December 2021, 171 eyes of 102 patients with severe PM macular degeneration who were examined at Eye Center of Beijing Tongren Hospital of Capital Medical University were included in the study. The clinical data such as age, gender, axial length, spherical equivalent power, fundus color photography, and optical coherence tomography (OCT) were collected in detail. Six independent ophthalmologists (A, B, C, D, E, F) classified each fundus photography based on META-PM and ATN classification of atrophy (A) system and interobserver agreement was assessed by Kappa statistics. According to the classification standard of traction (T) in the ATN classification, the OCT images were interpreted and classified, in which T0 was subdivided into retinal pigment epithelium (RPE) and choroidal thinning, choroidal neovascularization (CNV) with partial RPE and choroidal atrophy, RPE, and choroidal atrophy. Lamellar macular hole can't be classified by ATN system, which was defined as TX. Kappa (κ) test was used to analyze the consistency of classification results between physicians A, B, C, D, E and F. κ value ≤0.4 indicates low consistency, 0.4<κ value ≤ 0.6 indicates moderate consistency, and κ value >0.6 indicates strong consistency. ResultsAmong the 171 eyes of 102 cases, there were 20 males with 37 eyes (19.6%, 20/102), and 82 females with 134 eyes (80.4%, 82/102); age was 61.97±8.78 years; axial length was (30.87±1.93) mm; equivalent spherical power was (-16.56±7.00) D. Atrophy (A) classification results in META-PM classification and ATN classification, the consistency of physician A, B, C, D, E and physician F were 73.01%, 77.19%, 81.28%, 81.28%, 88.89%; κ value were 0.472, 0.538, 0.608, 0.610, 0.753, respectively. In the ATN classification, the T0, T1, T2, T3, T4, and T5 were in 109, 18, 11, 12, 9, and 8 eyes, respectively; TX was in 4 eyes. ConclusionsThere are differences in the consistency of classification of severe PM macular lesions among physicians with different clinical experience, and the consistency will gradually improve with the accumulation of clinical experience.

    Release date:2022-07-18 03:05 Export PDF Favorites Scan
  • Reporting quality assessment of Bland-Altman method consistency evaluation in China from 2014 to 2016

    Objectives To evaluate the reporting quality of Bland-Altman method consistency evaluation in China from 2014 to 2016. Methods WanFang Data, VIP and CNKI databases were electronically searched to collect literature about the application of Bland-Altman method from 2014 to 2016 in China. Two reviewers screened literature, extracted data, and the data were then statistically analyzed by SPSS 22.0 software. Results A total of 376 articles were included. The published articles on Bland-Altman method had major flaws (not conforming to reporting standards) in the application conditions, evaluation indexes, graphic depiction and so on. Merely 11.4% of the literature set the clinically acceptable consensus values in the pre-period studies. Merely one literature (0.3%) correctly compared the 95%CI of 95%LoA with the clinically acceptable threshold which had been set previously. The offer rates of the differences between the two measurements and the 95%CI, 95%LoA and 95%CI of 95%LoA in the figure were 95.9%, 9.5%, 94.6% and 4.4%, respectively. Conclusions The reporting quality of Bland-Altman method consistency evaluation in China is of low quality, specifically not conforming to reporting standards. We should strengthen the introduction of Bland-Altman methodology to improve the reporting quality.

    Release date:2018-01-20 10:09 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content