Objective To introduce a new surgical approach to rectify the shortened lower limbs. Methods From March 1985 to October 2000,288 cases of shortened lower limbs were treated and reviewed. Closed fracture at the metaphysis was made by a self-made “needle saw”, and then the “multiple-plane and double-track elongation instrument” was adopted to elongate the fractured bone. There were totally 161 cases of male and 127 cases of female included, with average age 21.3 years old, ranging from 12 to 29 years old, among which there were 268 cases elongated at the proximal metaphysis of the tibia, 16 cases at the distal femur and 4 cases at the distal tibia. All of the cases were followed up for 6 to 8 months before clinical evaluation. Results The lower limbs in 288 cases were elongated for 3.0 to 11.5 cm in 24 to 96 days, averaging 47 days, which fulfilled pre-operative plan. In the second week after the operation, new calculus and periosteum formed obviously in the gap between the fractured parts, and in 6 to 8 months bone union was observed at the fractured site in all cases. There was no nerve or blood vessel injury, or non-union of the metaphysis fracture. The functionof the manipulated knee joints and ankle joints recovered well. Conclusion It is a practical and safe surgical option to rectify the shortened lower limbs by closed fracture at the metaphysis, followed by elongation of the fractured bone,without any complication such as non-union or atrophy of manipulated bone, andwith no need of internal fixation or bone grafting.
OBJECTIVE The purpose of this study was to find the best material for valvular wrapping operation of deep vein of lower limb and to study the diagnostic value of colored Ultrasonic-Doppler for valvular incompetency of the deep vein and the function of the popliteal valve. METHODS Strips of autogenous saphenous vein, autogenous fascia lata and pieces of polytetrafluroethylene artificial vessel were used respectively as the wrapping material for narrowing the valve in 30 dogs. The results of three different wrapping material were obtained by colored Ultrasonic-Doppler and transpopliteal venography in 78 patients. The hemokinetics of the popliteal valve was examined in 20 normal persons. RESULTS In the saphenous vein and fascia lata groups, diffuse fibrosis and marked narrowing of the femoral vein were found, while in the group of artificial vein graft, the graft was intact without prominent fibrosis and narrowing of the vein. In comparing with the result of venography, the accuracy of diagnosis by colored Ultrasonic-Doppler was 91.86%. The femoral and popliteal venous valves closed at the same time when holding the breath, but the popliteal venous valve opened more widely than the femoral venous valve when the calf muscles of the leg contracted. CONCLUSION It was suggested that the graft was the best material for valvular wrapping operation, and colored Ultrasonic-Doppler was an important and non-invasive method for the diagnosis of incompetency of deep vein. The popliteal venous valve was the important barrier for protection of the function of deep vein.
Objective To investigate clinical significanceand surgical protocols about the balance of the lower limb lengths in the total hip arthroplasty. Methods Forty-eight patients undergoing the unilateral primary total hip arthroplasty from March 2000 to October 2004 were retrospectively studied. In 12 hips, the prostheses were of the cement type; in 36 hips, of the mixture type. Thirty patients with an equal limb length had a fractured femoral neck, 10 patients had a shortened (1.0-2.0 cm) limb, 6 patients had a shortened (2.0-4.0 cm)limb, and 2 patients had a shortened (4.0-6.0 cm) limb. Based on the clinical measurement and radiographic examination, the surgical protocols were designed, the hip prosthesis type was chosen, and the neck length of the femoral prosthesis and the position of osteotomy were estimated. By the wearing of the acetabula properly, the best rotation point was found out during the operation. The cut plane of the femoral neck was adjusted according to the results of the radiographic and other examinations. The neck length was readjusted after the insertion of the prosthesis so as to achieve an intended limblength equalization. Results All the patients were followed up for 3-42 months.According to the Harris scoring system, clinical results were excellent in 30 patients, good in 12, fair in4, and poor in 2. Of the 30 patients with an equal limb before operation, 5 were lengthened 1.0-2.0 cm in their lower limbs, and 1 lengthened 2.5 cm postoperatively. Of the 18 patients with shortened limbs before operation, 10 returned to the same lengths in their lower limbs, 6 were lengthened 1.0-2.0 cm in their lower limbs, but 2 with seriously-shortened lower limbs for congenital dysplasia of the hipjoint were still shortened 2.0-3.0 cm in the limb length after operation. The Harris hip scores revealed an average of 92.3 points in the patients with an equal limb length, and 88.6 points in the patients with shortened limbs. 〖WTHZ〗Conclusion Many factors, such as surgical protocols, prosthesis type designs, and the management techniques during the operation, can affect the limb length after operation. As the limb length discrepancy will make the patients feel disappointed, the clinical measurements are very important before operation. Application of the comprehensive appraisal methods during the operation, use of the soft tissuebalance method, and skills for obtaining an equal limb length during the total hip arthroplasty are also important for improving the surgical result further.
【Abstract】 Objective To explore the effectiveness of multiple joint arthroplasty in treating lower limb joint disease. Methods Between January 2000 and December 2007, 5 patients with lower limb joint disease (three or more joints were involved) were treated with total hip and knee arthroplasty. There were 3 males and 2 females, aged from 27 to 59 years (mean, 41.8 years). Two patients had ankylosing spondylitis and 3 had rheumatoid arthritis, whose hip and knee joints were involved. Four patients lost the ability of walking preoperatively, 1 patient could only walk with crutch. The Harris score was 24 ± 24 and the Hospital for Special Surgery (HSS) score was 28 ± 15. All patients underwent multiple joint arthroplasty simultaneously (2 cases) or multiple-stage (3 cases). Results Wounds healed by first intention in all patients. In 1 patient who had dislocation of the hip after operation, manipulative reduction and immobilization with skin traction were given for 3 weeks, and no dislocation occurred; in 2 patients who had early sign of anemia, blood transfusion was given. All patients were followed up 46-140 months with an average of 75 months. The patients could walk normally, and had no difficulty in upstairs and downstairs. The stability of the hip and knee was good, and no joint infection or loosening occurred. The Harris score was 88 ± 6 at last follow-up, showing significant difference when compared with the preoperative score (t=8.16, P=0.00); the HSS score was 86 ± 6, showing significant difference when compared with the preoperative score (t=13.96, P=0.00). Conclusion Multiple joint arthroplasty is an effective treatment method in patients with lower limb joint disease, which can significantly improve life quality of patients.
Objective To investigate the clinical effect of the one-stage arteriovenous shunt on the extensive arterial ischemic disease of the lower extremities. Methods The one-stage arteriovenous shunts in the lower extremities were applied to 90 patients with extensive arterial ischemic diseases, including arterial occlusive disease (AODs,62 patients) and thromboangiitis obliterans (TAOs,28 patients). By the retrospective analysis on the clinical materials and the follow-up of the postoperative patients, the immediate and the longterm surgical outcomes were summarized. Results During the hospitalization, 88 patients achieved a remarkable surgical effectiveness, with an immediate surgical effectiveness rate of 97.7% (88/90), but 2 patients failed in the operation and had to undergo amputation of the lower limb. Of the 72 patients who were followed up for 0.5-5 years after the arteriovenous shunt operation, 64 could have a sufficient blood supply to the lower extremities, with a longterm effectiveness rate of 88.9% (64/72); however, 8 patients had to undergo transplantation of the greater omentum or amputation of the lower limb. Conclusion The one-stage arteriovenous shunt performedon the lower extremities for an extensive arterial ischemic disease is a simpler and more effective surgical protocol for reconstruction of the circulation of the patient who is not suitable for the operation of arterial bypass.
Objective To analyze the effectiveness of free vascularized fibula grafts (FVFG) for extensive bone defects after resection of lower limb malignant bone tumors. Methods Between November 2015 and July 2018, 15 cases of lower limb malignant bone tumors were treated. There were 12 males and 3 females with an average age of 12.3 years (range, 9-21 years). There were 11 cases of osteosarcoma and 4 cases of Ewing’s sarcoma. The tumor located at middle femur in 8 cases, lower femur in 4 cases, and middle tibia in 3 cases. The disease duration was 2-6 months (mean, 3.2 months). The tumor was completely removed, and the length of the bone defect was 8-23 cm (mean, 17.7 cm). The bone defect was repaired by FVFG, and combined inactivated tumor bone was used in 8 cases of femoral bone defect. Results The average operation time was 280 minutes (range, 180-390 minutes). The average blood loss was 310 mL (range, 200-480 mL). All incisions healed by first intention. All patients were followed up 2-24 months with an average of 14.5 months. Bone healing achieved in all patients at 9-18 months (mean, 12.3 months) after operation except 1 patient which was followed up only 2 months. The fibula grafts had active metabolism and the average bone metabolism score was 184 (range, 111-257) in effected side and 193 (range, 127-259) in contralateral side. There was no difference between bilateral sides. The average Enneking score was 24.6 (range, 20-30) at last follow-up. No ankle instability or paralysis of common peroneal nerve occurred. Conclusion FVFG appeared very efficient in repair of extensive bone defect after resection of lower limb malignant bone tumor.
ObjectiveThis study was aimed to evaluate the clinical efficacy of mechanical thrombectomy using the AngioJet System for the treatment of lower extremity acute arterial embolism and thrombosis.MethodsThe clinical data of 20 patients with acute lower extremity arterial embolism and thrombosis admitted to the Department of Vascular Surgery in the People’s Hospital in Gansu Province where the author worked from September 2016 to March 2017, were retrospectively analyzed. All patients were treated with the AngioJet mechanical thrombectomy system. Clinical data of the patients were retrospectively collected. The clinical efficacy of AngioJet mechanical thrombectomy wasanalyzed.ResultsEighteen (90.0%) of the 20 patients successfully completed the mechanical thrombectomy by using the AngioJet System. The mean time for hospital stay and operation was (4.2±1.4) d and (1.3±0.4) h, respectively. The average doses of urokinase and heparin during operation were (35.80±12.30) ×104 U and (45.10±8.30) mg, respectively. Two patients received a complementary treatment of incision for removing the thrombus. Two patients received catheter-directed thrombolysis after the mechanical thrombectomy, 5 patients received bare-metal stent implantation after balloon expansion. Clinical success was in 16 cases. According to the Cooley standard, 10 patients were in excellent condition,6 in good condition, 2 in fair condition, and 2 in poor condition. There were 2 cases of distal arterial embolization,2 cases of antecardial discomfort of bradycardia, and 4 cases of bleeding at the puncture point, but no serious bleeding complications such as gastrointestinal and intracranial hemorrhage occurred. A total of 16 patients presented myoglobinuria during and after operation. All patients were followed up for 6–12 months. The results of ultrasound examination showed that the artery was patency in 15 cases. One patient died of myocardial infarction in 9 months after surgery,2 patients developed lower extremity ischemia symptoms again after surgery, and 2 patients had lower extremity ulcer caused by lower extremity ischemia symptoms. During the follow-up period, no lower limb necrosis, amputation, and death occurred in the remaining patients.ConclusionsThe AngioJet mechanical thrombectomy system is safe and effective. Combined with the use of catheter-directed thrombolysis and stent implantation, the AngioJet mechanical thrombectomy could lead to quick recovery of the perfusion of the lower extremity and improve the limb salvage rates, exhibiting excellent clinical value.
ObjectiveTo discuss the implantation and conversion technology of convertible inferior vena cava filter and the experience of management.MethodsThe clinical data of 115 patients with convertible inferior vena cava filter implantation admitted to our vascular surgery center from January 2018 to December 2018 was retrospectively analyzed.ResultsAmong the 115 patients with convertible inferior vena cava filter implantation, 74 were males and 41 were females. The ages ranged from 22 to 87 years, with median age 54 years. The successful rate of filter implantation was 100% without any surgical related complications. After implantation surgery, patients were followed up from 4 to 455 days with a median of 90 days and the recurrence rate of adverse events was 7.8% (9/115). The recurrence time were 16 to 104 days after conversion, with a median of 42 days. Twenty-three patients (20.0%) received filter conversion, one of them failed and all the others succeeded. The technical successful rate was 95.7% (22/23). The conversion operative time was 22.8 to 51.4 min, with median time 27.4 min. The intervals between implantation and conversion were from 4 to 455 days, with median time 159 days. Accessory techniques were used in 20 of 22 successful filter conversions and the application rate of accessory technique was 90.9%. The patients were followed-up from 30 to 180 days after conversion with a median time of 90 days and no adverse event was reported.ConclusionConvertible inferior vena cava filter is a significant choice for patients application of inferior vena cava filter due to its high safety of conversion surgery, technical success rate and possibility of conversion after long-term indwelling.