west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "临床应用" 103 results
  • 低气管极度阻塞术中部分心肺转流的应用

    目的 将部分心肺转流应用于低气管极度阻塞并呼吸窘迫患者的手术.方法 局部麻醉下经双侧股-股动、静脉插管建立体外循环,同时对患者施行病变的手术治疗.结果 转流中氧饱和度为0.92~0.99,动脉血氧分压为14.7~20 kPa(110~150mmHg),动脉血二氧化碳分压为5~5.6 kPa(37.5~42mmHg),pH为7.23~7.29,达到了较好的人工临时辅助肺呼吸的作用.结论 体外循环技术用于气管外科急诊手术,为保证麻醉及手术的顺利实施创造条件.

    Release date:2016-08-30 06:35 Export PDF Favorites Scan
  • CURRENT DEVELOPMENT OF RESEARCH OF BIODEGRADABLE INTERBODY FUSION CAGE

    Objective To summarize the basic research and the cl inical appl ication of biodegradable interbody fusion Cage. Methods Recent l iterature concerning biodegradable interbody fusion Cage at home and abroad was extensively reviewed, and current developments of the basic research and the cl inical appl ication of biodegradable interbody fusion Cage were investigated. Results Basic research showes that the stiffness of biodegradable interbody fusion Cage is lower than that of metall ic Cage, so it can enhance interbody fusion. As interbody fusion proceeded, biodegradable interbody fusion Cage degrades constantly, but the speed of degradation can not keep in parallel with that of fusion. In addition, the tissue response to degradation products is controversy. Cl inical appl ication showes that the biodegradable interbody fusion Cage can enhance interbody fusion and maintain disc space height. The short term results are good, however, the long term results need further observation. Conclusion Biodegradable interbody fusion Cage can effectively enhance interbody fusion.

    Release date:2016-09-01 09:04 Export PDF Favorites Scan
  • Clinical application of three-dimensional printed metal prosthesis in joint surgery

    Objective To summarize the application progress of three-dimensional (3D) printed metal prosthesis in joint surgery. Methods The related literature was extensively reviewed. The effectiveness of 3D printed metal prosthesis in treatment of joint surgery diseases were discussed and summarized, including the all key issues in prosthesis transplantation such as prosthesis stability, postoperative complications, bone ingrowth, etc. Results 3D printed metal prosthesis has good matching degree, can accurately reconstruct and restore joint function, reduce operation time, and achieve high patient satisfaction in short- and medium-term follow-up. Its application in joint surgery has made good progress. Conclusion The personalized microporous structure prostheses of different shapes produced by 3D printing can solve the problem of poor personalized matching of joints for special patients existing in traditional prostheses. Therefore, 3D printing technology is full of hope and will bring great potential to the reform of orthopedic practice in the future.

    Release date:2019-06-04 02:16 Export PDF Favorites Scan
  • CLINICAL APPLICATION AND RELATIVE EXAMINATION OF MORSELIZED BONE

    Objective To review progress of clinical application ofmorselized bone and to investigate relative exploration on it.Methods The recent articles on morselized bone in the field of clinicand experimental research were extensively reviewed, and relative examination of morselized bone referring to method and mechanism were investigated carefully.Results Morselized bone worked well clinically, especially inrevision ofartificial total hip joint, and it was proved effective with lots of advantages.Conclusion Morselized bone functions well clinically. Although its mechanism requires a further research, it still has a promising value in clinical application.

    Release date:2016-09-01 09:33 Export PDF Favorites Scan
  • EXPERIMENTAL STUDY PREVENTION OF REPERFUSION INJURY OF SKELETAL MUSCLE BY LOCAL HYPOTHERMIA AND ITS CLINICAL APPLICATION

    Local hypothermia as a preventive method to reperfusion injury of skeletal muscles was studied. Sixteen Japanese rabbits were divided into four groups at random. Before the tourniquet was inflated, a cold gel pack was applied to the right hind leg of each rabbit for 15 minutes to produce local hypothermic condition, without application of tourniquet the left hind limb was under local hypothermic condition as a control. The duration of tourniquet ischemia was 4 hours, and then reperfusion for one and two hours in the A and B groups respectively; in the C and D groups the duration of ischemia was 5 hours, and reperfusion for one and two hours, respectively. The muscle temperature averaged 16.6 degrees C with a needle thermocouple in the hind limb under local hypothermia. The serum K+, LA, SOD, LPO were determined from bilateral femoral veins, and electron and light microscopic studies of sural muscles were done in the post-reperfusion period. It was found that the K+, LA, LPO were lower than that of the control groups (P lt; 0.01), but SOD was higher than that of the control group (P lt; 0.01). Electron and light microscopic studies showed sight but reversible damage of muscular structure with the possibility of in the hypothermic groups cell regeneration. Basing on this experimental results, this method was applied in 45 cases reparative and reconstructive surgery of limbs. The duration of application of tourniquet averaged 2 hours and 57 minutes, the longest being 4 hours and 31 minutes, when the muscle temperature had reduced to 22.4 degrees C. There were no postoperative complications associated with this technique. Local hypothermia appeared to be a safe and effective method of decreasing the reperfusion damage after ischemia.

    Release date:2016-09-01 11:07 Export PDF Favorites Scan
  • PROGRESS OF AUTOLOGOUS FAT GRAFTING IN CLINICAL APPLICATIONS OF THE FACE

    【Abstract】 Objective To review the progress of autologous fat grafting of the face and outline different arguments in this field. Methods Recent literature concerning autologous fat grafting of the face was reviewed and analyzed. Results The applications and techniques for autologous fat grafting have been matured increasingly. It not only can adjust the proportion of facial contours, restore tissue volume, but also can improve the local skin texture. Reliable clinical results have achieved in facial augmentation and rejuvenation. Although there are arguments about donor site, harvesting technique, processing technique, and grafting technique, the basic principle is the same. Conclusion From the perspective of evidence-based medicine, clinicians are rich in clinical experience, but objective evidence is insufficient. So further researches should be carried to look for scientific evidences.

    Release date:2016-08-31 04:21 Export PDF Favorites Scan
  • CLINICAL APPLICATION OF THE ANTEROLATERAL THIGH FLAP IN 112 PATIENTS

    Objective To investigate the anatomic variations of the perforator vessels of anterolateral thigh (ALT) flap and the clinical indications. Methods From March 1985 to August 2004, the anterolateral thigh flapgraft was performed in 112 patients. The clinical data were analyzed. There were 67 males and 45 females, aging from 5 to 65 years with an average of 38.5 years. According to recipient site condition, four methods of flap harvesting were as follows:① 78 received free fasciocutaneous flaps;② 22 received free adipofascial flaps;③ 5 received pedicled island fasciocutaneous flaps; ④ 7 received pedicled reverse-flow island fasciocutaneous flaps. Facial, neck, breast, extremityjoint, plantar, and perineum defects were repaired and the effectiveness and donor site morbidity were evaluated. Results The blood supply of ALT flap came from the descending branch or transverse branch of the lateral circumflex femoralartery. The skin vessels were found to be septocutaneous perforators in 33% of flaps and to be musculocutaneous perforators in 77% of flaps. Of 112 flaps, 107 survived completely, the survival rate was 95.6% with little donor site morbidity. Conclusion ALT flap is a versatile softtissue flap. If refined to perforator flap, it can achieve better results in reconstructing defect and minimizing donor-site morbidity.

    Release date:2016-09-01 09:26 Export PDF Favorites Scan
  • Clinical application and technical specifications for pediatric helium-free magnetoencephalography

    Magnetoencephalography (MEG), as a non-invasive brain functional imaging technology, plays an increasingly important role in the diagnosis and treatment of pediatric neurological disorders. In recent years, the emergence of helium-free MEG based on optical pumped magnetometer (OPM) technology (OPM-MEG) has provided a novel tool for pediatric brain research and precise diagnosis and treatment of brain diseases. This article elaborates on the technical principles, clinical application standards, testing protocols, and reporting requirements for pediatric OPM-MEG, aiming to establish a scientific and standardized operational framework to promote its rational application and development in pediatric practice. The content covers key aspects such as core equipment parameters, indications and contraindications, pre-examination preparations, optimized operational workflows, data quality control, and reporting standards, offering comprehensive guidance for conducting pediatric OPM-MEG examinations.

    Release date:2025-09-05 01:18 Export PDF Favorites Scan
  • 重组人表皮生长因子促进创面愈合的临床观察

    【摘要】 目的 观察重组人表皮生长因子(rhEGF)促进创面愈合的临床效果。 方法 2007年1月-2009年1月对49例有肢体对称性烧伤的患者,49对中厚取皮区上(用rhEGF)下自身对照;52对植皮区左右(用rhEGF)自身对照。 结果 供区用rhEGF组愈合天数平均10 d,对照组为13 d;植皮区用rhEGF组愈合天数平均11 d,对照组为15 d。供区和植皮区半年后增生性瘢痕发生率为rhEGF组明显低于对照组。 结论 rhEGF可明显促进创面愈合并可提高创面愈合的质量,减轻瘢痕的形成。

    Release date: Export PDF Favorites Scan
  • CLINICAL APPLICATION OF BIO-DERIVED BONE TRANSPLANTATION WITH TISSUE ENGINEERINGTECHNIQUE:YEAR FOLLOW-UP

    To summarize the medium-term cl inical result of bio-derived bone transplantation in orthopedics with tissue engineering technique. Methods From December 2000 to June 2001, 10 cases of various types of bone defect were treated with tissue engineered bone, which was constructed in vitro by allogenous osteoblasts from periosteum (1 × 106/ mL) with bio-derived bone scaffold following 3 to 7 days co-culture. Six men and 4 women were involved in this study, aged from 14 to 70 years with a median of 42 years. Among them, there were 2 cases of bone cyst, 1 case of non-union of old fracture, 6 cases of fresh comminuted fracture with bone defect, and 1 case of chronic suppurative ostemyel itis. The total weight of tissue engineered bone was 3-15 g in all the cases, averaged 7.3 g in each case. Results The wound in all the case healed by first intention. For 7 year follow up, bone union was completed within 3.0 to 4.5 months in 9 cases, but loosening occurred and the graft was taken out 1 year after operation in 1 case. The X-ray films showed that 9 cases achieved union except one who received resection of the head of humerus. No obvious abnormities were observed, and the function of affected l imbs met daily l ife and work. Conclusion Bio-derived tissue engineered bone has good osteogenesis. No obvious rejection and other compl ications are observed in the cl inical appl ication.

    Release date:2016-09-01 09:12 Export PDF Favorites Scan
11 pages Previous 1 2 3 ... 11 Next

Format

Content