west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "人工全髋关节置换术" 136 results
  • PRELIMINARY EXPERIENCES IN MINIMALLY INVASIVE AND MINIINCISION SURGERY TOTAL HIP ARTHROPLASTY FOR LATE OSTEONECROSIS OF THE FEMORAL HEAD

    Objective To explore the effect of minimally invasive and mini-incision surgery (MIS) in total hip arthroplasty (THA) on late osteonecrosis of femoral head (ONFH). Methods From March 2003, Eighteen patients (22 hips) with ONFH underwent MIS in THA. Their ages ranged from 24to 57 years, including 13 males and 5 females. The mean body mass index ranged from 17.1 to 30.1(24.6 on average). The Harris hip score was 46 points before operation. Modified posterior-lateral approach was adopted, and the MIS THA was performed by cementless prosthesis. As a comparison, 18 patients (22 hips) were performed by conventional THA at the same period. The data, including bleeding volume during operation, incision length, operative time, and postoperative function recovery, were compared. Results Follow-ups were done for 6 to 20 months (11 months on average). Dislocation occurred in one patient that underwent conventional THA 2 days after operation. No complication occurred in MIS THA group. The incision lengths ranged from 8.7 to 10.5 cm (9.3 cm on average) in MIS THA group, being statistically different (Plt;0.01). There was no significant difference in Harris scoring of the function between the two groups both before the operation and after the operation (Pgt;0.05). The operative time was almost the same, but the bleeding volume in MIS THA group was less (Plt;0.05). The function recovery was faster in MIS THA group.Conclusion The MIS THA is an alternative to the treatment of late ONFH. The advantages of MIS THA are fewer trauma, less bleeding volume, and faster recovery. The MIS THA should be performed by surgeons with rich experiences in THA and hospitals with necessary instruments. 

    Release date:2016-09-01 09:30 Export PDF Favorites Scan
  • Early effectiveness of robot-assisted total hip arthroplasty via direct superior approach

    ObjectiveTo evaluate the early effectiveness of the robot-assisted total hip arthroplasty (THA) via direct superior approach (DSA).MethodsBetween March 2021 and April 2021, 11 patients (11 hips) were treated with a robot-assisted THA via DSA. There were 7 males and 4 females, with an average age of 55 years (range, 26-73 years). There were 5 patients of osteoarthritis secondary to hip dysplasia and 6 patients of osteonecrosis of femoral head. Preoperative hip Harris score was 55.8±6.3. The operation time, volume of blood loss, length of incision, postoperative blood transfusion and hospital stay, and the incidence of surgical complications were recorded. The visual analogue scale (VAS) score and Harris score were used to evaluate hip joint pain and function. The leg length discrepancy (LLD) was measured on the X-ray films. The inclination angle and anteversion angle of the acetabular component were also measured, and the difference between the planned and actual values were compared.ResultsOne THA was performed via conventional posterolateral approach finally because of poor exposure. The rest of 10 THAs were performed with assistance of robotic arm via DSA. The average operation time was 89 minutes (range, 65-120 minutes); the average length of incision was 10.5 cm (range, 9-13 cm); and the average blood loss was 400 mL (range, 110-740 mL). One patient was given a blood transfusion for 2 unit. All incisions healed by first intention and no neurovascular injury, deep vein thrombosis, or fracture occurred. The length of hospital stay after operation was 2-6 days (mean, 4.4 days). The duration of follow-up was 1-3 months (mean, 2.1 months). The VAS score was 0 in 9 patients and 2 in 1 patient at the day of discharge. At last follow-up, the hip Harris score was 84.9±6.7, showing significant difference when compared with that before operation (t=−8.717, P=0.000). The inclination and anteversion angles were (37.4±2.0)° and (17.1±4.5)°, respectively, and there was no significant difference when compared with the planned values [(38.2±1.6)°, (16.6±3.7)°] (t=1.809, P=0.104; t=–1.103, P=0.299). The LLD ranged from –2 to 4 mm. No complication such as dislocation, aseptic loosening, or periprosthetic joint infection occurred. ConclusionThe robot-assisted THA via DSA has encouraged early effectiveness.

    Release date:2021-10-28 04:29 Export PDF Favorites Scan
  • COMPARATIVE STUDY ON ASSOCIATION BETWEEN FEMORAL HEAD SIZE AND LINEAR WEAR RATE OF HIGHLY CROSS-LINKED POLYETHYLENE LINER

    ObjectiveTo investigate the effects of the femoral head size on the linear wear rate of highly crosslinked polyethylene (HXLPE) l iner in total hip arthroplasty (THA). MethodsA retrospective analysis was performed on the cl inical data of 41 patients (43 hi ps) who underwent primary THA with HXLPE liner and different sizes of femoral heads between January 2004 and December 2007 for hip diseases. There were 22 males (23 hi ps) and 19 females (20 hi ps) with a mean age of 60.2 years (range, 35-89 years), including femoral neck fracture (26 hi ps), avascular necrosis of femoral head (8 hi ps), osteoarthritis (5 hi ps), rheumatoid arthritis (2 hi ps), and congenital hip dysplasia (2 hi ps). According to the size of the femoral head, the patients were divided into 2 groups: standard head size (26 and 28 mm) was used in 25 cases (26 hi ps, group A) and big head size (32, 36, and 40 mm) in 16 cases (17 hi ps, group B). The cumulative penetration of the femoral head, linear wear rate, and effectiveness were evaluated and compared between 2 groups. ResultsAll the incisions healed by first intention, no complications of infection, deep vein thrombosis, or nerve injury occurred. The patients were followed up 5-9 years (mean, 5.7 years). No two-stage revision was needed. Harris score was significantly improved at 3 months, 6 months, and 1, 2, 3, 4, and 5 years after operation when compared with preoperative score in each group (P < 0.05), but no significant difference was found between different time points after operation in 2 groups (P > 0.05), and between 2 groups at each time point (P > 0.05). Acetabular abduction angle was (31.4±3.8)° in group A and (32.3±4.1)° in group B, showing no significant difference (t=0.482, P=0.621). At last follow-up, no radiographic or cl inical loosening was observed in each group. At 5 years after operation, X-ray results of acetabular components showed radiolucent line ( < 1 mm) in 1 case (1 hi p) and 1 case (1 hi p) of 2 groups respectively; but X-ray results of femoral components showed no radiolucent line. There was no significant difference in the cumulative penetration of the femoral head between 2 groups at 1, 2, 3, 4, and 5 years after operation (P > 0.05). The linear wear rate was (0.026±0.007) mm/year in group A and (0.025±0.007) mm/year in group B, showing no significant difference between 2 groups (t=0.708, P=0.483). ConclusionNo association is found between femoral head size and the linear wear rate of HXLPE liner. It is an ideal interface of THA because of its low linear wear rate.

    Release date: Export PDF Favorites Scan
  • ONE-STAGE RADICAL DEBRIDEMENT AND TOTAL HIP ARTHROPLASTY FOR TREATMENT OF ACTIVE TUBERCULOSIS OF THE HIP

    ObjectiveTo investigate the short-term effectiveness of one-stage radical debridement and total hip arthroplasty (THA) in the treatment of active tuberculosis of the hip. MethodsBetween January 2006 and June 2011,one-stage radical debridement and THA were performed on 12 cases (12 hips) of active tuberculosis of the hip.There were 7 males and 5 females,aged 18-60 years (mean,46.3 years).The disease duration ranged from 6 to 24 months (mean,10.5 months).According to Babhulkar and Pande staging criteria,5 cases were at stage Ⅲ and 7 cases were at stage IV.One case had sinus,and 2 cases had previous pulmonary tuberculosis.Preoperative hip range of motion was (35.83±9.25)°; hip Harris score was 36.83±6.44.Erythrocyte sedimentation rate (ESR) was 45-90 mm/1 h (mean,62.4 mm/1h); C-reactive protein (CRP) was 19-50 mg/L (mean,33.6 mg/L).Perioperatively all the patients accepted the regular anti-tuberculous medication. ResultsThe results of histopathological examination and PCR detection were positive for tuberculosis bacillus.Postoperatively the incisions healed primarily.All the patients were followed up 25-60 months (mean,40.8 months).The ESR and CRP returned to normal level with no liver injury.Tuberculosis recurrence occurred in 1 patient at 4 months after operation,which was cured after revision.X-ray film showed no prosthesis shift,prosthesis loosening,or sinus tract.At 18-24 months after operation,the bilateral sides had the same bone density,which was similar to that at the final follow-up.Hip range of motion was significantly improved to (107.08±13.56)° (t=14.571,P=0.000).Hip Harris score was significantly increased to 88.00±10.78 (t=16.750,P=0.000). ConclusionA combination of one-stage radical debridement and THA is a safe method to treat active tuberculosis of the hip,which can relief symptoms and improve hip function,with low recurrence and satisfactory short-term effectiveness.

    Release date: Export PDF Favorites Scan
  • Efficacy and safety of a loading high-dose tranexamic acid followed by postoperative five doses in total hip arthroplasty: A randomized controlled trial

    ObjectiveTo evaluate the efficacy and safety of a loading high-dose tranexamic acid (TXA) followed by postoperative 5 doses in total hip arthroplasty (THA) by a randomized controlled trial.MethodsSeventy-two patients who underwent primary unilateral THA between December 2017 and March 2018 were randomly divided into two groups (36 patients in each group). A single dose of 20 mg/kg TXA was administered intravenously before 5-10 minutes of operation in group A; and a single dose of 40 mg/kg TXA was administered intravenously in group B at the same time point. All patients received 5 doses of 1 g TXA at 3, 6, 12, 18, and 24 hours after the first dose. There was no significant difference in gender, age, weight, height, body mass index, disease type, and combined medical diseases between the two groups (P>0.05). Total blood loss (TBL), lowest postoperative hemoglobin (Hb) level, fibrinolysis parameters [fibrin (ogen) degradation products (FDP), D-dimer], inflammatory factors [C-reaction protein (CRP), interleukin-6 (IL-6)], adverse events (thrombosis, pulmonary embolism) were recorded and compared between groups.ResultsThe TBL was significantly lower in group B than in group A (P<0.05). Furthermore, the lowest postoperative Hb level was significantly higher in group B than in group A (P<0.05). There was no significant difference in FDP and D-dimer before operation between the two groups (P>0.05). The levels of FDP and D-dimer were significantly lower in group B than in group A at 12 and 36 hours postoperatively (P<0.05). There was no significant difference in CRP and IL-6 before operation between the two groups (P>0.05). The levels of CRP and IL-6 were significant lower in group B than in group A at 12, 24, and 36 hours postoperatively (P<0.05). There was no significant difference at 14 days (P>0.05). There were 2 patients with intramuscular venous thrombosis in group A and 1 in group B after operation, and there was no significant difference in the incidence of embolic events (P>0.05). No deep venous thrombosis or pulmonary embolism occurred in all groups.ConclusionA loading high-dose TXA followed by postoperative 5 doses can further reduce the blood loss, provide additional fibrinolysis and inflammation control in THA, without increasing the risk of embolic events.

    Release date:2019-07-23 09:50 Export PDF Favorites Scan
  • SHORT-TERM EFFECTIVENESS OF TOTAL HIP ARTHROPLASTY FOR POST-TRAUMATIC OSTEOARTHRITIS SECONDARY TO ACETABULAR FRACTURE

    Objective To discuss the short-term effectiveness of total hip arthroplasty (THA) for post-traumatic osteoarthritis secondary to acetabular fracture. Methods Between January 2004 and March 2012, the clinical data was analyzed retrospectively from 12 cases (13 hips) of post-traumatic osteoarthritis secondary to acetabular fracture undergoing THA. Of 12 patients, 6 were male and 6 were female, with an average age of 55.6 years (range, 40-68 years). The locations were the left hip in 5 cases, the right hip in 6 cases, and bilateral hips in 1 case. The interval between acetabular fracture and THA was 65.7 months on average (range, 12-240 months). The preoperative hip Harris score was 48.8 ± 9.5. Results The incisions healed by first intention. No deep vein thrombosis and infection occurred postoperatively. Ten cases were followed up 1-7 years (mean, 4.8 years). The hip Harris score was 86.5 ± 8.6 at last follow-up, showing significant difference when compared with preoperative score (t=10.520, P=0.006). X-ray films showed no acetabular prosthesis instability. Stem subsidence (2 mm) occurred in 1 case, peri-prosthetic osteolysis in 2 cases, and heterotopic ossification in 2 cases (Brooker type I and type II in 1 case, respectively). Conclusion THA has satisfactory short-term effectiveness for post-traumatic osteoarthritis secondary to acetabular fracture. The good effectiveness is based on strict case selection, pathological evaluation, and the proper acetabular reconstruction.

    Release date:2016-08-31 04:08 Export PDF Favorites Scan
  • Estimation of acetabular cup prosthesis coverage rate in total hip arthroplasty based on X-ray films

    Objective To explore the method of accurately estimating the acetabular cup prosthesis coverage rate (hereinafter referred to as “cup coverage rate”) in total hip arthroplasty (THA) based on X-ray films, and to determine the effective parameters that can be used to estimate the cup coverage rate. MethodsThe three-dimensional printed pelvic models were established based on CT data of 16 healthy pelvis, and the acetabular prosthesis were implanted according to conventional THA procedure. The length and width of the uncovered area of the acetabular cup prosthesis were measured by a modified X-ray recording method with a rotating C-arm X-ray machine, and the cup coverage rate was calculated. Then the differences among the traditional anteroposterior X-ray recording method, the modified method, and actual measurement on pelvic model were statistically analyzed. The correlation between the area of the uncovered area of the prosthesis and its width and length was analyzed by using multiple linear regression analysis. Results The cup coverage rates of traditional method, modified method, and actual measurement were 78.22%±3.36%, 86.74%±3.61%, and 89.62%±2.62%, respectively, with significant differences (P<0.05). The results of multiple linear regression analysis showed that the width and length were positively linear with the uncovered area of the prosthesis, and the regression equation was as follows: uncovered area of the prosthesis=−21.192+0.248×width+0.140×length, and the coefficient of determination R2=0.857, P<0.001. Conclusion Compared with the traditional method, the modified method can more accurately evaluate the cup coverage rate during THA, and the width of the uncovered area of the prosthesis can be used as an effective reference for the cup coverage rate.

    Release date:2024-05-13 02:25 Export PDF Favorites Scan
  • Mid-term effectiveness of total hip arthroplasty with subtrochanteric shortening osteotomy in treatment of Crowe type Ⅳ developmental dysplasia of hip

    ObjectiveTo explore the mid-term effectiveness of total hip arthroplasty (THA) with subtrochanteric shortening osteotomy in treatment of Crowe type Ⅳ developmental dysplasia of the hip (DDH).MethodsBetween September 2009 and March 2014, a total of 49 patients (57 hips) who were diagnosed with Crowe type Ⅳ DDH were treated with THA and subtrochanteric shortening osteotomy. Of the 49 patients, 7 were male and 42 were female with an average age of 44.6 years (range, 20-73 years). The preoperative Harris score was 44.68±3.39 and the preoperative leg length discrepancy was (5.27±0.55) cm.ResultsAll incisions healed primarily. All patients were followed up 32-87 months (mean, 52.1 months). At last follow-up, the Harris score was 85.67±2.89 and the leg length discrepancy was (1.12±0.48) cm, showing significant differences when compared with the preoperative values (t=–69.53, P=0.00; t=42.94, P=0.00). X-ray films showed that bone union of the femoral osteotomy end at 6 months after operation. There was no loosening and subsidence of prosthesis at last follow-up.ConclusionThe subtrochanteric shortening osteotomy with THA in treatment of Crowe type Ⅳ DDH can obtain satisfactory mid-term effectiveness with low risk of peripheral vascular and nerve traction injuries.

    Release date:2018-04-03 09:11 Export PDF Favorites Scan
  • EFFECT OF FEMORAL OFFSET RECONSTRUCTION ON PELVIC STABILITY DURING GAIT AFTER TOTAL HIP ARTHROPLASTY

    Objective To investigate the effect of femoral offset reconstruction on pelvic stabil ity during gait after total hip arthroplasty. Methods According to the inclusion criteria, 29 patients undergoing unilateral total hip arthroplasty between January 2000 and December 2005 were selected. There were 10 males and 19 females with an average age of 64.3 years (range, 33-75 years). The affected hips included 15 left hips and 14 right hips. The follow-up time was from 5 to 10 years (mean, 7.7 years). The Harris score was 90 to 100 (mean, 97) at last follow-up. The femoral offset ratio (FOR) was calculated by measuring the femoral offset of the bilateral hips on radiograph, and then the patients were divided into 2 groups: group A (the femoral offset of diseased hip was less than that of normal hip, n=10) and group B (the femoral offset of diseased hip was greater than that of normal hip, n=19). The pelvis kinematic variables were measured by three-dimensional gait analysis to collect the magnitude of pelvic obl ique angle (POA). Results In group A, the FOR was 0.81 ± 0.08 and the POA was (—0.42 ± 0.91)°. In group B, the FOR was 1.27 ± 0.15 and the POA was (1.02 ± 0.94)°. For the normal hip, the POA was (1.15 ± 0.85)°. The POA was significantly less in group A than in group B and the normal l imb (P lt; 0.05). The difference in POA had no significance between group B and the normal hip (P gt; 0.05). The POA was positive relative with FOR (r=0.534, P=0.003), and the regression equation was y= — 2.551+ 2.781x. Conclusion The femoral offset reconstruction is crucial to improve hip abductor function and gait.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • USE OF SMARTPHONE IN ACETABULAR COMPONENT ANGLE MEASUREMENT DURING TOTAL HIP ARTHROPLASTY

    ObjectiveTo evaluate the accuracy of using smartphone to measure the angle of acetabular component in total hip arthroplasty (THA). MethodsBetween June 2012 and September 2015, the acetabular abduction and anteversion angles were measured in 50 patients undergoing THA. There were 24 males and 26 females, aged 37 to 83 years (mean, 71 years). The left hip was involved in 22 cases and the right hip in 28 cases. Of 50 patients, 34 suffered from fracture of the femoral neck, and 16 suffered from avascular necrosis of the femoral head. Acetabular dysplasia was excluded in all cases. A smartphone was used to measure the acetabular abduction and anteversion angles during operation; standard Picture Archiving and Communication Systems (PACS) was used to measured the acetabular abduction and anteversion angles on the X-ray film at 1 week after operation. It was defined as positive that the component angle values by PACS measurement were greater than those by the smartphone measurement, whereas as negative. The two measurement methods were compared, and intra-observer variability was assessed by analyzing the intraclass correlation coefficient (ICC), the Mann-Whitney U-test was used to analyze difference. ResultsThe ICC was 0.84 in the acetabular component angles by smartphone and PACS measurement methods. The acetabular component abduction angle was (44.02±1.33)° and the anteversion angle was (17.62±2.20)° by smartphone measurement. The acetabular component abduction angle was (44.74±4.05)° and the anteversion angle was (17.22±5.57)° by PACS measurement. There was no significant difference between two measurement methods (Z=-1.977, P=0.482; Z=-0.368, P=0.713). The acetabular component angle was in the safe zone in 44 cases; and the acetabular component anteversion angle was beyond safe range of 1 to 5°, and the abduction angle was beyond safe range of 1 to 3° in 6 cases. Intra-measurement variability was -21 to +10° for the anteversion angle and -10 to + 9° for the abduction angle, indicating that the acetabular component anteversion angle by smartphone measurement was greater than that by the PACS measurement, and the abduction angle was less than that by PACS measurement. ConclusionSmartphone is a convenient tool to measure the acetabular component angle in THA.

    Release date:2016-10-02 04:55 Export PDF Favorites Scan
14 pages Previous 1 2 3 ... 14 Next

Format

Content