west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "内固定" 838 results
  • Clinical study on the subchondral screw compression technique assisted reduction of residual or secondary collapse of lateral tibial plateau

    Objective To explore the reduction and support effect of the subchondral screw compression technique for residual or secondary collapse of the lateral tibial plateau during operation. Methods Between January 2020 and June 2021, 11 patients with residual or secondary collapse of the lateral tibial plateau during operation were treated with the subchondral screw compression technique. There were 6 males and 5 females, aged 52.3 years old (range, 27-64 years). The fractures were caused by traffic accident in 10 cases and falling from height in 1 case and located at the left knee in 6 cases and the right knee in 5 cases. According to Schatzker classification, there were 5 cases of type Ⅱ fractures, 4 cases of type Ⅲ fractures, and 2 cases of type Ⅴfractures. According to the three columns classification, there were 5 cases of lateral column, 4 cases of lateral column and posterior column, and 2 cases of three columns. The time from injury to operation was 4.5 days (range, 3-7 days). During the follow-up, X-ray films were obtained and the Rasmussen standard was used to evaluate the quality of fracture reduction, meanwhile fracture healing was observed. The medial proximal tibial angle (mPTA), posterior tibial slope angle (pTSA), and articular surface collapse were measured at immediate and 12 months after operation. The knee joint range of motion was evaluated at last follow-up, and the knee joint function was evaluated using the Hospital for Special Surgery (HSS) score. Results All operations were successfully completed, with a mean operation time of 71.4 minutes (range, 55-120 minutes), and a mean hospital stay of 8.0 days (range, 5-13 days). The incisions all healed by first intention, without complications such as infection, flap necrosis, or vascular and nerve injury. All patients were followed up 16.5 months on average (range, 12-24 months). X-ray films showed that the fracture reduction score was 14-18 (mean, 16.7) according to Rasmussen score criteria; and 5 cases were rated as excellent and 6 as good. All fractures healed clinically with a mean clinical healing time of 14.9 weeks (range, 12-16 weeks), and there was no complications such as plate or screw loosening. At 12 months after operation, the mPTA and pTSA were (87.5±1.7)° and (6.2±3.1)°, respectively; there was no significant difference when compared to the values at immediate after operation [(87.6±1.8)° and (6.5±3.1)°] (P>0.05). The articular surface of the tibial plateaus was effectively supported, and it collapsed again by 0-1.0 mm at 12 months, with an average of 0.4 mm. At last follow-up, the knee joint range of motion was 115°-135° (mean, 126.8°) and the HSS score for knee joint function was 87-98 (mean, 93.9). Five patients underwent secondary operation to remove the internal fixator at 12-18 months after operation.ConclusionThe subchondral screw compression technique is helpful for the reduction of residual or secondary collapse of the lateral tibial plateau during operation, and can provide good support for osteochondral blocks.

    Release date:2023-12-12 05:09 Export PDF Favorites Scan
  • CLINICAL STUDY ON TWO INTERNAL FIXATION METHODS KANEDA AND Z-PLATE IN THE OPERATION OF ANTERIOR SURGICAL APPROACH AFTER THORACOLUMBAR FRACTURES

    OBJECTIVE To study the difference between two internal fixation methods Kaneda and Z-plate in the operation of anterior surgical approach and decompression after thoracolumbar fractures. METHODS: The bio-mechanical structure of the internal fixture, install when operating, complications and time of the operation were compared in the cases by Kaneda and Z-plate. RESULTS: Z-plate method had the following characteristics: reasonable of the bio-mechanical structure; stability after internal fixture being installed; capability of completely propping up the injured centrum and keeping the height of middle-column; simple operation when installing internal fixture and shorter time of operation (1.1 hours, P lt; 0.05); fewer complications. CONCLUSION: Z-plate is an ideal internal fixation method in the operation of anterior surgical approach after thoracolumbar fractures. Thoracolumbar vertebra Fracture Internal fixation

    Release date: Export PDF Favorites Scan
  • RECONSTRUCTION OF THE UNSATBLE PELVIC FRACTURES

    Objective To investigate the clinical characteristics of unstable pelvic fractures and to find out an alternative for the treatment. Methods From October 2000 to June 2004, fifty-six patients with unstable pelvic fractures were treated by open reduction and pelvic-reconstructed plate fixation to recover the anatomical structure of pelvis and acetabulum. According to Tile classification, 33 cases were type B (15 cases were Tile B1, 11 cases were Tile B2, 7 cases were Tile B3); 23 cases were type C (10 cases were Tile C1, 8 cases were Tile C2, 5 cases were Tile C3). Results The 56 cases were followed up 12 to 68 months(26 months in average).All cases with fractures got healed during 3 to 6 mouths. According to the Majeed evaluation, 40 cases were excellent, 11 cases were good, 4 cases were fair, and only one case was a failure. The rate of excellency and goodness was 91.07%.The pelvic abnormity was rectified; partial patients felt light pain in iliac scar. Conclusion The choice of the proper operative approach and pelvic-reconstructed plate fixation by allowingfor fracture classification is a good and dependable means for treating unstablepelvic fractures.

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
  • RESECTION OF SPINAL TUMOR AND RECONSTRUCTION OF SPINAL STABILITY

    OBJECTIVE: Both primary and metastatic tumor of spine can influence spinal stability, spinal cord and nerves. The principles of dealing spinal tumor are resection of tumor decompression on spinal cord and reconstruction of spinal stability. METHODS: Since Aug. 1993 to Oct. 1996, 15 cases with spinal tumor were treated, including 4 primary spinal tumor and 11 metastatic tumor. Tumor foci were mainly in thoracic and lumbar spine. Graded by Frankel classification of spinal injuries, there were 1 case of grade A, 1 of grade B, 3 of grade C, 5 of grade D and 5 of grade E. Tumors of upper lumbar spine and thoracic spine were resected through anterior approach. Posterior approach also was adopted once posterior column was affected. Tumors of lower lumbar spine were resected by two-staged operation: firstly, operation through posterior approach to reconstruct spinal stability: secondly, operation through anterior approach. After resection of tumor, the spines were fixed by Kaneda instrument, Steffee plate or Kirschner pins. To fuse the spine, bone grafting was used in benign tumor and bone cement used in malignant tumor. RESULTS: Except one patient died from arrest of bone marrow, the others were followed up for 3 to 20 months. Postoperatively, 11 patients could sit up on one foot with the help of body supporter, and 9 patients could walk in two weeks under careful monitoring. There was no exacerbation of symptom and failure of fixation. The function of spinal cord was improved: 1 case from grade B to grade E, 1 from A to C, 2 from C to E and 4 from D to E. CONCLUSION: The spine can be reconstructed for weight bearing early by internal fixation. The symptom can be relieved and the nervous function can be improved by resection of tumor and decompression.

    Release date:2016-09-01 11:05 Export PDF Favorites Scan
  • 近关节骨折镍钛记忆合金骑缝钉内固定治疗探讨

    1984年6月~1989年10月,应用镍钛记忆合金骑缝钉治疗近关节或关节内骨折71例,取得了满意效果。伤口均Ⅰ期愈合。随访6个月~5年,未见不良反应。

    Release date:2016-09-01 11:37 Export PDF Favorites Scan
  • Application of three-dimensional printing technology for closed reduction and percutaneous cannulated screws fixation of displaced intraarticular calcaneus fractures

    Objective To evaluate the effectiveness of three-dimensional (3-D) printing assisting minimally invasive for intraarticular calcaneal fractures with percutaneous poking reduction and cannulate screw fixation. Methods A retrospective analysis was performed of the 19 patients (19 feet) with intraarticular calcaneal fracture who had been treated between March 2015 and May 2016. There were 13 males and 6 females with an average age of 38.2 years (range, 24-73 years). There were 3 open fractures and 16 closed fractures. By Sanders classification, 12 cases were type Ⅱ, 7 cases were type Ⅲ. By Essex-Lopresti classification, 13 cases were tongue type, 6 cases were joint-depression type. The time from injury to surgery was 1-10 days (mean, 4.7 days). A thin slice CT scan was taken of bilateral calcaneus in patients. By using the mirror imaging technique, the contralateral mirror image and the affected side calcaneus model were printed according to 1∶1 ratio. The displacement of fracture block was observed and contrasted, and the poking reduction was simulated. Calcaneal fracture was treated by percutaneous minimally invasive poking reduction and cannulate screw fixation. The Böhler angle and Gissane angle at immediate after operation and last follow-up was measured on X-ray films, and compared with preoperative measurement. The functional recovery was evaluated by American Orthopaedic Foot and Ankle Society (AOFAS) scores. Results The operation time was 25-70 minutes (mean, 45 minutes). The intraoperative blood loss was 10-40 mL (mean, 14.5 mL). All the incisions healed by first intention and had no relevant postoperative complications such as skin necrosis, nail tract infection, and osteomyelitis. All the patients were followed up 12-25 months (mean, 14.6 months). All patients obtained fracture healing, and the fracture healing time was 8-14 weeks (mean, 10.3 weeks). No screw withdrawal or breakage occurred during follow-up; only 1 patient with Sanders type Ⅱ fracture, whose calcaneus height was partially lost at 6 weeks after operation, the other patients had no reduction loss and fracture displacement, and no traumatic arthritis occurred. The Böhler angle and Gissane angle at immediate after operation and last follow-up were significantly improved when compared with preoperative ones (P<0.05), but there was no significant difference between at immediate after operation and last follow-up (P>0.05). The AOFAS score was 76-100 (mean, 88.2), and the results were excellent in 10 feet, good in 7, and fair in 2, the excellent and good rate was 89.5%. Conclusion 3-D printing assisting minimally invasive for intraarticular calcaneal fractures with percutaneous poking reduction and cannulate screw fixation can reduce the surgical trauma, improve the quality of reduction and fixation, and make the operation more safe, accurate, and individualized.

    Release date:2017-11-09 10:16 Export PDF Favorites Scan
  • A comparative study on effectiveness of closed reduction and internal fixation of intertrochanteric fracture assisted with skeletal tractor and traction table

    ObjectiveTo investigate the effectiveness and advantages of skeletal tractor in closed reduction and proximal femoral nail antirotation (PFNA) internal fixation of intertrochanteric fracture compared with traction table.MethodsThe clinical data of 86 patients with intertrochanteric fractures, who were treated with closed reduction and PFNA internal fixation between October 2016 and March 2018 and met the selection criteria, was retrospectively analysed. Among them, 44 cases were treated with skeletal tractor (trial group) and 42 cases were treated with traction table (control group). There was no significant difference between the two groups in gender, age, cause of injury, fracture side, AO classification, and degree of osteoporosis (P>0.05). The preoperative position time, operation time, intraoperative fluoroscopy times, intraoperative blood loss, fracture healing time, intraoperative and postoperative complications, and postoperative Harris score were compared between the two groups.ResultsThe operation was successfully completed in both groups. Compared with the control group, the patients in the trial group had shorter preoperative position time and operation time, fewer intraoperative fluoroscopy times, and less intraoperative blood loss (P<0.05). The patients were followed up 12-21 months in trial group (mean, 14.2 months) and 12-22 months in control group (mean, 14.3 months). Venous thrombosis of lower extremity occurred in 8 patients (3 cases of trial group and 5 cases of control group) after operation. Internal fixation failure occurred in 5 patients (2 cases of trial group and 3 cases of control group) during 1 year after operation. All fractures healed except for those with internal fixation failure, the fracture healing time was (11.6±2.9) weeks in trial group and (12.4±3.6) weeks in control group; and there was no significant difference between the two groups (t=1.250, P=0.214). At 1 year after operation, Harris score of the trial group was 86.2±5.9 and that of the control group was 84.1±6.1. There was no significant difference between the two groups (t=1.768, P=0.080).ConclusionCompared with traction table, skeletal tractor in closed reduction and PFNA internal fixation of intertrochanteric fracture can significantly shorten the preoperative position time and operation time, reduce the intraoperative fluoroscopy times, improve the operation efficiency, and have similar effectiveness.

    Release date:2020-04-29 03:03 Export PDF Favorites Scan
  • Application of “door-shaft method” in limited open reduction and internal fixation with locking plate for two- and three-part fractures of the proximal humerus

    ObjectiveTo investigate the effectiveness of limited open reduction via “door-shaft method” and internal fixation with locking plate for two- and three-part fractures of the proximal humerus.MethodsThe clinical data of 64 patients with proximal humeral fractures who were admitted between January 2013 and December 2016 and met the selection criteria were retrospectively analyzed. There were 23 males and 41 females, with an average age of 68.0 years (range, 50-89 years). The injuries were caused by falling in 57 cases, traffic accident in 5 cases, and falling from height in 2 cases. The interval between injury and operation was 1-7 days (mean, 2.1 days). According to Neer classification, there were 28 cases of two-part fractures and 36 cases of three-part fractures. According to the angulation direction of the proximal humeral neck shaft angle, there were 21 cases of adduction fractures and 43 cases of abduction fractures. The fractures were treated with limited open reduction via “door-shaft method” and proximal humerus internal locking systems for internal fixation. The operation time, intraoperative blood loss, number of fluoroscopy, hospital stay, and complications were recorded. The fracture healing was reviewed by X-ray film and the healing time was recorded. The shoulder joint function was evaluated by Neer score standard.ResultsThe operation time was 45-127 minutes, with an average of 82.3 minutes. The intraoperative blood loss was 30-125 mL, with an average of 62.7 mL. Intraoperative fluoroscopy was performed 30-69 times, with an average of 37.0 times. The hospital stay was 6-23 days, with an average of 10.3 days. All incisions healed by first intention. All patients were followed up 12-37 months, with an average of 18.3 months. X-ray film re-examination showed that all fractures healed, the healing time was 12-21 weeks, with an average of 14.3 weeks. After operation, 3 cases had shoulder stiffness and 1 case had fracture malunion. At last follow-up, the Neer score of shoulder joint function was 49-97, with an average of 83.1. Among them, 38 cases were excellent, 13 cases were good, 10 cases were fair, and 3 cases were poor. The excellent and good rate was 79.7%. The excellent and good rate of patients with two-part fractures was 82.1% (23/28), and the excellent and good rate of patients with three-part fractures was 77.8% (28/36).ConclusionThe “door-shaft method” not only reduces the difficulty of the Joystick technique in the reduction of proximal humerus fractures, but also provides auxiliary stability. It is used for limited open reduction and internal fixation with locking plate to treat the two- and three-part fractures of the proximal humerus, which can achieve good effectiveness.

    Release date:2021-07-29 05:02 Export PDF Favorites Scan
  • 三种内固定方法治疗肩锁关节脱位的疗效分析

    Release date:2016-09-01 09:28 Export PDF Favorites Scan
  • 三种内固定方式治疗锁骨骨折临床疗效分析

    Release date: Export PDF Favorites Scan
84 pages Previous 1 2 3 ... 84 Next