Right-sided cardiac valvular diseases have traditionally been considered less important than disease of mitral or aortic valve. However, severe tricuspid regurgitation could lead to right ventricle dysfunction and reduce patients' survival rate. In clinic setting, tricuspid valve disease should be paid more attention for patients with secondary tricuspid regurgitation caused by left-sided valvular surgery combined with irreversible annular dilatation increasing the risk of re-operation. In this review, we summarize the epidemiology, anatomy, pathology, diagnosis, ultrasound and cardiac magnetic resonance imaging findings in patients with tricuspid regurgitation.
ObjectiveTo evaluate early outcomes of transthoracic pulmonary valve implantation for the treatment of moderate and severe pulmonary regurgitation by using homemade self-expanding valve (SalusTM). MethodsPatients with severe pulmonary regurgitation who underwent transthoracic pulmonary valve implantation in Guangdong Provincial People’s Hospital from September 2, 2021 to November 25, 2022 were prospectively enrolled. The early postoperative complications and improvement of valve and heart function were summarized and analyzed. ResultsA total of 25 patients were enrolled, including 16 males and 9 females, with an average age of 24.5±1.5 years and an average weight of 57.0±3.0 kg. The mean systolic diameters of the bifurcation near the main pulmonary artery, the stenosis of the middle segment of the aorta and near the valve of the right ventricular outflow tract of the patients were 31.8±7.4 mm, 30.6±5.9 mm and 38.4±8.0 mm, respectively. All patients were successfully implanted with valves, and there were no serious complications such as death, coronary compression, stent fracture, valve displacement and infective endocarditis in the early postoperative period. The indexed left atrial longitudinal diameter, indexed right atrial longitudinal diameter, and indexed right ventricular outflow tract anteroposterior diameter decreased significantly after the operation. The degree of tricuspid and pulmonary valve regurgitation and the indexed regurgitation area decreased significantly. The above differences were statistically significant (P<0.05). ConclusionThe early outcomes of transthoracic pulmonary valve implantation with homemade self-expanding pulmonary valve (SalusTM) in the treatment of severe pulmonary regurgitation is relatively good, and the long-term outcomes need to be verified by the long-term follow-up studies with large samples.
ObjectiveTo compare the benefits and drawbacks of primary patch expansion versus pericardial tube right ventricular-pulmonary artery connection in patients diagnosed with pulmonary atresia with ventricular septal defect (PA/VSD). MethodsA retrospective study was conducted on patients diagnosed with PA/VSD who underwent primary right ventricular-pulmonary artery connection surgery at our center between 2010 and 2020. Patients were categorized into two groups based on the type of right ventricular-pulmonary artery connection: a pericardial tube group and a patch expansion group. Clinical data and imaging findings were compared between the two groups. ResultsA total of 51 patients were included in the study, comprising 31 males and 20 females, with a median age of 12.57 (4.57, 49.67) months. The pericardial tube group included 19 patients with a median age of 17.17 (7.33, 49.67) months, while the patch expansion group consisted of 32 patients with a median age of 8.58 (3.57, 52.72) months. In both groups, the diameter of pulmonary artery, McGoon index, and Nakata index significantly increased after treatment (P<0.001). However, the pericardial tube group exhibited a longer extracorporeal circulation time (P<0.001). The reoperation rate was notably high, with 74.51% of patients requiring further surgical intervention, including 26 (81.25%) patients in the patch expansion group and 12 (63.16%) patients in the pericardial tube group. No statistical differences were observed in long-term cure rates or mortality between the two groups (P>0.005). Conclusion In patients with PA/VSD, both patch expansion and pericardial tube right ventricular-pulmonary artery connection serve as effective initial palliative treatment strategies that promote pulmonary vessel development and provide a favorable foundation for subsequent radical operations. However, compared to the pericardial tube approach, the patch expansion technique is simpler to perform and preserves some intrinsic potential for pulmonary artery development, making it the preferred procedure.
Objective To assess clinical results of three different conduit materials (Gore-Tex synthetic graft,bovinejugular vein and autologous pericardium)for palliative right ventricle-to-pulmonary artery (RV-PA) shunt,and explore the correlation between suitable conduit size and patients’ body weight and McGoon ratio. Methods We retrospectively analyzed clinical data of 24 patients with congenital heart diseases who underwent palliative RV-PA shunt in Department of Pediatric Cardiovascular Surgery of Fu Wai Cardiovascular Hospital from July 2010 to July 2012. There were 11 males and 13 females with their age ranging from 60 days to 6 years and body weight of 10.22±7.41 kg. There were 22 patients with pulmonary atresia and ventricular septal defect (PAVSD),1 patient with tetralogy of Fallot (TOF) and 1 patient with doubleoutlet right ventricle (DORV). Among different conduit materials,autologous pericardium was used for 17 patients,Gore-Texsynthetic graft was used for 5 patients,and bovine jugular vein was used for 2 patients. Conduit size and children’s body weight were analyzed with linear regression,then the equation was corrected with McGoon ratio. Results There was no perioperative death. Postoperative percutaneous saturation (SpO2)of the 24 children was 20.37%±28.33% higher than preoperative SpO2 . Electrocardiogram showed sinus rhythm in all the patients. Twenty-three patients were NYHA classⅡ,and 1 patient was NYHA classⅢ. Postoperative mechanical ventilation time of patients with autologous pericardium were significantly shorter than those of patients with other 2 materials (P=0.017). Sixteen patients were followed up from 10 months to 2 years after discharge,including 12 patients with autologous pericardium,3 patients with Gore-Tex synthetic graft and 1 patient with bovine jugular vein. During follow-up,McGoon ratio of patients with autologous pericardium,Gore-Tex synthetic graft and bovine jugular vein were 1.98±0.46,1.83±0.33 and 1.68 respectively,all of which weresignificantly higher than preoperative McGoon ratio (P<0.05). Six patients underwent radical corrective surgery,including5 patients with autologous pericardium and 1 patient with Gore-Tex synthetic graft. There was no complication directly related to surgery during follow-up. Linear regression was performed to form an equation between suitable conduit size and patients’ body weight:conduit diameter (mm)=0.327×body weight (kg)+4.599. McGoon ratio,conduit size and equationresult were compared to find a practical choice of conduit size. If McGoon ratio<0.8,the first integer greater than the equation result could be chosen. If McGoon ratio>1.2,the first integer less than the equation result could be chosen. If 1.2>McGoon ratio>0.8,the first integer either less or greater than the equation result could be chosen. Group analysis showed that patients who recovered better postoperatively were those whose conduit sizes were closer to equation results as well as equation results corrected with McGoon ratio. Conclusion All the 3 materials can be conventionally chosen for RV-PA shunt. Appropriate conduit size can be decided upon patients’ body weight and McGoon ratio for RV-PA shunt.
ObjectivesTo systematically review the efficacy of His-bundle pacing (HBP) and right ventricular pacing (RVP).MethodsPubMed, The Cochrane Library, Web of Science, EMbase, CNKI, VIP and WanFang Data databases were electronically searched to collect randomized controlled trials (RCTs) and cohort studies on efficacy of HBP and RVP from inception to December, 2018. Two reviewers independently screened literature, extracted data and assessed risk of bias of included studies, then, meta-analysis was performed using RevMan 5.3 software.ResultsA total of 8 studies involving 1 130 patients were included. The results of meta-analysis showed that: HBP group was superior to RVP group in QRS duration (MD=–43.88, 95%CI –52.53 to –35.22, P<0.000 01), LVEF (MD=4.53, 95%CI 2.67 to 6.38, P<0.000 01), and NYHA (MD=–0.85, 95%CI –1.14 to –0.56, P<0.000 01). However, the operation time (MD=15.21, 95%CI 11.44 to 18.98, P<0.000 01) and fluoroscopy duration (MD=2.98, 95%CI 2.10 to 3.85, P<0.000 01) of HBP group were longer than that of RVP group.ConclusionsCurrent evidence shows that, compared with RVP, HBP is superior in maintaining of QRS duration, LVEF and NYHA; however, the operation time is longer. Due to limited quality and quantity of the included studies, more high quality studies are required to verify above conclusion.