Objective To evaluate the fixation technique of using the cervical lateral mass plate in the cervical posterior approach operation. Methods Eight patients in this group were admitted from September 2001 to November 2006. Among the 8 patients, there were 6 males and 2 females, with their ages ranging from 28 to 78 years. Cervical vertebral fracture with dislocation was found in 4 patients, C2 spinal cord injury in 1, C1 fracture in 1, cervical spinal stenosis in 1, and C2-5 spinal cord neurofibroma in 1. Muscle strength 3-4. TheFrankel grading system was usedin 6 patients with traumatic injury. Before operation, Grade C was observed in 2patients,Grade D in 3,and Grade E in 1. All the operations were performed according to requirements of the Margel’s method. We positioned 40 screws in all the patients, including 4 screws at C2,6 screws at C3,12 screws at C4,4 screws at C5,4 screws at C6,2 screws at C7,and 6 screws at T1. Results The followingup for an average of 14.1 months (range,645 months) revealed that there was no malposition of the screws in the patients. One of the 8 patients developed spinal instability in the fixed segment at 3 months after operation. The headchestbrace was applied to the patient for 3 months, and the spinal fusion was achieved. The further followingup to 45 months indicated that there was no instability occurring. The remaining patients recovered to their spinal stability by the spinal fusion. The patients also recovered in their neurological function after operation. The Frankel assessment showed that 1 patient had Grade E, 3 from Grade D to Grade E, 1 from Grade C to Grade D, and 1 from Grade C to Grade E. Conclusion The cervical lateral mass plate fixation can provide the immediate and b segmental immobilization for the good cervical spine stability.
Objective To summarize the method and effectiveness of open reduction and internal fixation in the treatment of 4 cases of bipolar clavicle dislocations. Methods Between June 2017 and June 2022, 4 patients with bipolar clavicle dislocations were admitted. There were 3 males and 1 female. The age ranged from 27 to 63 years, with an average age of 45 years. There were 2 cases of crushing injury of mine car, 1 case of traffic accident injury, and 1 case of heavy object injury. The time from injury to operation was 3-7 days, with an average of 5.0 days. The sternoclavicular joint dislocations were classified as Grade Ⅱ in 1 case and type Ⅲ in 3 cases, and anterior dislocation in 3 cases and posterior dislocation in 1 case. The acromioclavicular joint dislocations were classified as Tossy type Ⅱ in 2 cases and type Ⅲ in 2 cases. After open reduction, the sternoclavicular joint and acromioclavicular joint were fixed with lateral malleolus locking titanium plate and clavicular hook plate, respectively. ResultsAll operations were successfully completed without vascular or nerve injury. All incisions healed by first intention. All patients were followed up 12-18 months, with an average of 14 months. At last follow-up, the shoulder joint functions were rated as excellent in 3 cases and good in 1 case according to Rockwood score. During follow-up, there was no loosening of internal fixator or fracture. The internal fixators were removed in all patients at 5-7 months after operation (mean, 6 months), and no re-dislocation occurred after removal. Conclusion For bipolar clavicle dislocation, open reduction combined with lateral malleolus locking titanium plate fixation of the sternoclavicular joint and clavicle hook plate fixation of the acromioclavicular joint can achieve good effectiveness. It has the advantages of simple operation, high safety, firm fixation, and fewer complications, and the shoulder function recovers well.
From January 1984 to November 1997, the boiling xenogenic bone (porcine and bovine bone) was applied in 65 patients. The xenogenic bone was used to promote bone healing in 24 cases, intramedullary bone graft in 37 and osteomyelitis in 4. All of the patients were followed up for 2 to 35 months. The results showed that in five cases there was infection after operation, and all other the wounds had primary healing. The xenogenic bone seemed to induce rejection in vivo. In the sevious cases immunosuppressive treatment was often needed. The volume of the bone grafted and the extent of the periosteum being stripped seemed to be important whether xenogenic bone graft would be successful or. There were lots of problem needed investigation.
Objective To assess the possibility of placing the posterior pedicle screw on atlas. Methods Twenty human cadaver specimens were used to insert pedicle screws in atlas, through the posterior arch or the pedicle of C1 into the lateral mass. The screw entry point was on the posterior surface of C1 posterior arch and at the intersection of the vertical line through the center of C2 inferior articular process and the horizontal line at least 3 mm below the superior rim of the C1 lamina. The screw of 3.5 mm in diameter was placed in a direction of 10° medial angle and 5° upwardangle. After placement of C1 pedicle screw, the distance from C1 screw entry point to the mediallateral midpoint of C1 pedicle, the maximum length of screw trajectory and the actual screw trajectory angles were measured. The direction of screw penetrating through the cortical of C1 pedicle or lateral mass and the injuries to the vertebral artery and spinal cord were observed.Results Forty pedicle screws were placed on atlas, the mean distance from C1 screw entry point to the medial-lateral midpoint of C1 pedicle was (2.20±0.42)mm, the maximum length of screw trajectory averaged (30.51±1.59)mm, and the actual screw trajectory angle measured (9.7±0.67)° in a medial direction and (4.6±0.59) ° in a upward direction. Only 1 screw penetrated the upper cortical bone of the atlas pedicle because the upward angle was too large, and 8 screws were inserted so deep that the inferior cortical bone of the C1 lateral mass was penetrated. But no injuries to the vertebral artery and spinal cord wereobserved. Conclusion C1 posterior pedicle screw fixation is quite accessible and safe, but the su
Forty cases of intertrochanteric fractures of femur were treated with percutaneous nonmetallic external fixator. The patients were followed up for 6 months to 3 years, and the fractures were all united without coxa vara or shirtening deformities. There was no mortality in this series. This method had the advantages ofbeing simple, save time and effort, less traumatic and early ambulation. The design of the apparatus tallied with the biomechanics of the neck and shaft of the femur.
ObjectiveTo assess the outcomes in indirect reduction technique via Nice knot for transverse patellar fractures.MethodsThe clinical data of 25 patients with transverse patellar fractures meeting the inclusion criteria between January 2017 and December 2018 were retrospectively analyzed. The patients were divided into trial group (n=13) and control group (n=12) according to different intraoperative reduction methods. No significant difference was found in gender, age, affected side, cause of fracture, classification, or the time from injury to operation between the two groups (P>0.05). In the trial group, No.2 suture was used to cross the quadriceps tendon and patellar tendon to construct the Nice knot, then the suture was tightened to make the distal and proximal fracture segments contact in an indirect reduction pattern. Depend on Nice knot’s sliding compression and self-stabilizing function, the suture mesh created an anterior tension band as a temporary fixation. In the control group, Weber’s clamp was used to hold the fracture segments directly and fixed temporarily. After reduction, terminal fixation was conducted using a titanium Kirschner wire with titanium cable in both groups. The operation time, intraoperative blood loss, follow-up time, fracture healing time, and complications were recorded and compared in the two groups. At last follow-up, the knee function was evaluated according to the Böstman scoring criteria for efficacy in patellar fractures.ResultsThe operation time in the trial group was significantly shorter than that in the control group (t=−2.165, P=0.041). There was no significant difference of intraoperative blood loss between the two groups (t=0.514, P=0.612). The incisions of the two groups healed by first intention. All the patients were followed up 12-16 months, with an average of 14.4 months, no significant difference was found in the follow-up time between the two groups (t=−0.309, P=0.760). One patient in the control group developed soft tissue irritation symptoms at 1 day after operation, and no special treatment was given, the symptoms disappeared at 2 months after operation. The fractures of the two groups healed at the 12-week follow-up. During the follow-up, there was no complication such as loosening and fracture of titanium cables and tendon tissue calcification. At last follow-up, the Böstman score presented no significant difference between the two groups (t=−0.086, P=0.932). In the trial group, an 80-year-old female patient was evaluated as good (score, 27) due to atrophy of the quadriceps femoris, leg weakness, and affected stair climbing, and the rest 24 patients were all evaluated as excellent.ConclusionThe indirect reduction with Nice knot can shorten the operation time in the treatment of transverse patellar fractures, and obtain good effectiveness.
ObjectiveTo summarize the effectiveness of nitinol memory alloy two foot fixator with autologous cancellous bone grafting in treating old scaphoid fracture and nonunion.MethodsBetween January 2013 and January 2017, 11 patients of old scaphoid fracture and nonunion were treated with nitinol memory alloy two foot fixator and autologous cancellous bone grafting. All patients were male with an average age of 26.1 years (range, 18-42 years). The fractures were caused by sport in 3 cases, falling in 7 cases, and a crashing object in 1 case. The interval between injury and operation was 6-18 months (mean, 8.9 months). Postoperative outcome measures included operation time, fracture healing time, grip strength, range of motion (ROM) of flexion, extension, ulnar deviation, and radial deviation, Mayo score, visual analogue scale (VAS) score, and the Disabilities of the Arm, Shoulder, and Hand (DASH) score.ResultsThe operation time was 35-63 minutes (mean, 48 minutes). All incisions had primary healing with no infection and loosening or breakage of internal fixator. All patients were followed up 12-30 months (mean, 20.7 months). X-ray films showed that fracture healing was achieved in all patients with an average time of 15 weeks (range, 12-25 weeks). All internal fixators were removed after 10-12 months of operation (mean, 11.2 months). At last follow-up, the grip strength, ROMs of flexion, ulnar deviation, and radial deviation were superior to those before operation (P<0.05), no significant difference was found in ROM of extension between pre- and post-operation (t=0.229, P=0.824). There were significant differences in above indexes between affected and normal sides (P<0.05). At last follow-up, the Mayo, VAS, DASH scores were also significantly superior to those before operation (P<0.05).ConclusionFor the old scaphoid fracture and nonunion, Ni-Ti arched shape-memory alloy fixator and autologous cancellous bone grafting can obtain good effectiveness, which is an effective treatment.
目的:探讨后路寰枢椎椎弓根螺钉内固定的术前计划方案,明确其手术指导意义。方法:选取经CT评估寰枢椎椎弓根螺钉置入可行的,并拟选择该手术治疗的上颈椎不稳患者15例,容积再现重建(VR)寰枢椎椎弓表面影像,了解个体椎弓后方表面解剖形态与骨性解剖标志。同时按寰枢椎椎弓根理想的钉道走行,多平面重建(MPR)个体椎弓根断面影像。术前根据这些解剖影像设计手术暴露路经、理想的进钉点与钉道轨迹。术中按该术前计划手术暴露,找到理想的进钉点并钻孔置椎弓根螺钉。将术中观察到的C1后弓及C2椎弓表面解剖,与术前CT重建影像对比。术后CT复查,评价螺钉置入情况。结果:15例术中观察到的C1后弓及C2椎弓表面解剖特征与术前CT容积再现的影像一致。参照寰枢椎椎弓CT影像解剖制定术前计划方案,术中按其逐一操作,手术简单、直观,无重要血管神经损伤,置钉准确。结论:根据CT容积再现与多平面重建的寰枢椎解剖影像,制定后路寰枢椎椎弓根螺钉内固定术前计划方案,指导手术安全、可靠。
Objective To investigate the surgical technique and effectiveness of volar locking plates for senile delayed distal radius fractures. Methods Between October 2014 and September 2015, 25 cases of delayed distal radius fractures were treated by volar locking plates. There were 3 males and 22 females with an average age of 73 years (range, 65-87 years). Injury was caused by tumble in 19 cases and by traffic accident in 6 cases. All the cases had closed fracture. According to the AO classification, 10 cases were rated as type A2, 7 cases as type A3, 3 cases as type B3, and 5 cases as type C1. The manual reduction and plaster immobilization were performed in 18 cases first, but reduction failed; no treatment was given in 7 cases before surgery. The time from injury to surgery was from 33 to 126 days (mean, 61 days). Preoperatively, the volar tilting angle was (–16.0±3.1)°; the ulnar inclining angle was (10.8±7.0)°; the radial shortening was (11.2±3.6) mm; the wrist range of motion was (41.0±7.5)° in flexion and was (42.0±6.3)° in extension; and the grip strength was 33.0%±3.1% of normal side. Results All incisions healed primarily, and no postoperative complication occurred. The patients were followed up 1-1.5 years (mean, 1.3 years). The X-ray films showed that fracture union was achieved in all the patients, with the mean healing time of 9.2 weeks (range, 8-12 weeks); the displacement of the articular surface was less than 1 mm. At last follow-up, the volar tilting angle was (13.1±3.2)°; the ulnar inclining angle was (21.9±4.6)°; the radial shortening was (2.0±1.1) mm; the wrist range of motion was (52.0±11.7)° in flexion and was (65.0±4.8)° in extension; and the grip strength was 84.0%±4.2% of normal side; all showed significant difference when compared with preoperative ones (P<0.05). According to the Gartland and Werley score, the results were excellent in 15 cases, good in 6 cases, fair in 2 cases, and poor in 2 cases at last follow-up; the excellent and good rate was 84%. Conclusion By the good design of the volar locking plate and the command of surgical techniques, good effectiveness can be achieved in the treatment of senile delayed distal radius fracture.