Six cases of old fracture of the tibia with large sear, bony defect, and shortening deformity of the limb were treated by elongation osteotomy at epiphysis and compression fixation of the fracture with external semilunar fixation frame. The bony defect ranged from 3cm to 6cm. Bony healing developed in all patients 4-7 months after operation. Early postoperative movement was suggested. The results revealed that there was an obvious improvement of the joint function and the shortened legs were corrected. The advantages of this method are that there is no need of bone grafting and operative treatment of the scar prior to treatment of the bone.
目的:评价外固定支架治疗桡骨远端骨折的疗效。方法:2004年3月至2008年8月以外固定支架或辅以克氏针、可吸收螺钉内固定治疗桡骨远端骨折37例。结果:31例获得4~28 个月(平均14 个月)的随访,所有骨折均临床愈合,平均愈合时间8周。腕关节功能按Sarmiento标准进行评定,优17例,良9例,可4例,差1例,优良率839%。结论:外固定支架治疗桡骨远端骨折疗效可靠,值得推广。
Forty cases of intertrochanteric fractures of femur were treated with percutaneous nonmetallic external fixator. The patients were followed up for 6 months to 3 years, and the fractures were all united without coxa vara or shirtening deformities. There was no mortality in this series. This method had the advantages ofbeing simple, save time and effort, less traumatic and early ambulation. The design of the apparatus tallied with the biomechanics of the neck and shaft of the femur.
Objective To investigate the effectiveness of hinged external fixator with mini-plate to treat terrible triad of the elbow. Methods Between August 2008 and June 2011, 11 patients with terrible triad of the elbow were treated with hinged external fixator combined with mini-plate. There were 9 males and 2 females, aged 22-56 years (mean, 34 years). The injuries were caused by falling from height in 8 cases and traffic accident in 3 cases. All patients were closed injury. The time from injury to operation varied from 8 hours to 7 days (mean, 3.7 days). According to Mason classification standard, all radial head fractures were type IV and complicated by posterior dislocation of the elbow; according to Regan-Morrey classification standard, ulna coronary process fractures were type I in 3 cases, type II in 3 cases, and type III in 5 cases. Results All the patients achieved primary healing of incision after operation and no nerve injury occurred. The patients were followed up 12-20 months (mean, 15 months). Two cases had screw channel infection after 12 weeks of operation, and 1 case had mild heterotopic ossification of the elbow after 4 months of operation. X-ray films showed that all fractures healed from 8 to 20 weeks (mean, 16 weeks). No recurrent dislocation or instability of the elbow occurred. At 12 months after operation, the elbow range of motion (ROM) were 120-145° (mean, 135°) in flexion, 0-25° (mean, 10°) in extension, 50-90° (mean, 70°) in pronation, and 50-80° (mean, 60°) in supination. According to Mayo elbow function evaluation standard, the results were excellent in 5 cases, good in 4 cases, and fair in 2 cases, with an excellent and good rate of 81.8%. Conclusion Hinged external fixator with mini-plate can enhance postoperative stability of the elbow. This therapy is beneficial to early functional exercise and obviously decrease the disability rate caused by complex damage on the elbow.
Objective To investigate the effectiveness of arthroscopy-assisted combined fixation of Kirschner wire and external fixator for treating extreme distal radial fractures. Methods Between January 2014 and May 2016, 21 patients who suffered from extreme distal radial fractures were treated by arthroscopy-assisted combined fixation of Kirschner wire and external fixator. There were 14 males and 7 females with an age of 32-57 years (mean, 42.3 years). The causes of injury included falling in 13 cases and traffic accident in 8 cases. The fracture type included 8 cases of type 23C1, 9 cases of type 23C2, and 4 cases of type 23C3 according to AO/OTA classification. The time from injury to operation was 3-7 days (mean, 4.4 days). The Mayo score and disability of arm, shoulder, and hand (DASH) score were used to assess the pain and function of the wrist joint. Results There was no needle red swelling, tendon irritation, or orther early complications. All the patients were followed up 10-35 months (mean, 18.3 months). The fracture healing time was 9-13 weeks (mean, 10.6 weeks). At last follow-up, the Mayo score was 87-94 (mean, 90.9); and 17 cases were excellent and 4 were good. The DASH score was 7-13 (mean, 10.6). Conclusion Arthroscopy-assisted combined fixation of Kirschner wire and external fixator for treating extreme distal radial fractures has the advantages of firm fixation, early functional exercise, less postoperative complications, and good functional recovery of wrist joint.
【Abstract】 Objective To investigate the effect of the volar capsular l igament complex on stabil ity of the wrist jointand to provide basic biomechanical theoretical criteria for cl inic appl ication of the external fixator. Methods Nine upperl imbs specimens (left 6, right 3) were taken from fresh adult cadavers to make wrist joint-bone capsular l igament complex specimens. Firstly, soft tissues of forearms and hands were resected and capsular membranes and l igaments were reserved to make the bone-articular l igament complex (normal specimen). Secondly, the volar capsular l igament complex was cut off from radial malleolus to ulnar malleolus (impaired specimen). Thirdly, the impaired volar capsular l igament complex was interruptedly sutured by the use of 4# suture silk (repaired specimen). To simulate cl inical operation with external fixator, the biomechanical test was done according to the sequence (normal, impaired, repaired, repaired and fixed, impaired and fixed). Statistical significance was analyzed through selected loads at the three different shifts (1.5, 2.0, 2.5 cm). Results According to the sequence (normal, impaired, repaired, repaired and fixed, impaired and fixed), when the shift was 1.5 cm, the different respective loads were (60.74 ± 20.60), (35.23 ± 13.88), (44.36 ± 20.78), (168.40 ± 29.21) and (139.00 ± 33.18) N, respectively. When the shift was 2.0 cm, the different loads were (138.46 ± 12.93), (87.17 ± 24.22), (97.52 ± 23.29), (289.00 ± 54.29) and (257.98 ± 55.74) N, respectively. When the shift was 2.5 cm, the different loads were (312.87 ± 37.15), (198.16 ± 37.14), (225.66 ± 30.96), (543.15 ± 74.33) and (450.35 ± 29.38) N, respectively. There was no statistically significant difference between the impaired and repaired specimens (P gt; 0.05). Similarly, there was statistically significant difference among the rest specimens (P lt; 0.05). The same statistical results were obtained when the two different shifts were compared. There was statistically significant difference at the three different shifts for the same specimen (P lt; 0.05). Conclusion Volar capsular l igament complex is an important anatomic structure to keep stabil ity of the wrist joint. The carpal instabil ity arises out of the injured complex. Repairing the injured complex only can not immediately restore stabil ity of the wrist joint. The external fixator can effectively help to diminish the relative shift of the impaired capsular l igament complex, to reduce the load of the repaired complex and to protect the complex accordingly. The device plays an important role in maintaining stabil ity of the wrist joint.
Objective To compare the clinical results of locking compress plate (LCP) as an external fixator and standard external fixator for treatment of tibial open fractures. Methods Between May 2009 and June 2012, 59 patients with tibial open fractures were treated with LCP as an external fixator in 36 patients (group A), and with standard external fixator in 23 patients (group B). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, location, and interval between injury and surgery between 2 groups (P gt; 0.05). The time of fracture healing and incision healing, the time of partial weight-bearing, the range of motion (ROM) of knee and ankle, and complications were compared between 2 groups. Results The incidence of pin-track infection in group A (0) was significantly lower than that in group B (21.7%) (P=0.007). No significant difference was found in the incidence of superficial infection and deep infection of incision, and the time of incision healing between 2 groups (P gt; 0.05). Deep vein thrombosis occurred in 5 cases of group A and 2 cases of group B, showing no significant difference (χ2=0.036, P=0.085). All patients were followed up 15.2 months on average (range, 9-28 months) in group A, and 18.6 months on average (range, 9-47 months) in group B. The malunion rate and nonunion rate showed no significant difference between groups A and B (0 vs. 13.0% and 0 vs. 8.7%, P gt; 0.05); the delayed union rate of group A (2.8%) was significantly lower than that of group B (21.7%) (χ2=5.573, P=0.018). Group A had shorter time of fracture healing, quicker partial weight-bearing, greater ROM of the knee and ankle than group B (P lt; 0.05). Conclusion The LCP external fixator can obtain reliable fixation in treating tibial open fracture, and has good patients’ compliance, so it is helpful to do functional exercise, improve fracture healing and function recovery, and reduce the complication incidence.