west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "技术" 971 results
  • The Method of Tissue Engineering in Spinal Cord Injury Scaffold Forming Technology’s Exploration

    组织工程的提出、建立和发展,为最终实现脊髓损伤的修复和真正意义上的结构、形态与功能重建开辟了新的途径。支架的生物活性、三维结构和表面微观结构,材料的降解性等众多因素都对细胞增殖,分化和组织形成有明显影响。组织工程的发展也将改变传统的医学模式,使得再生医学得以进一步发展,并最终用于疾病的治疗。

    Release date:2016-09-08 09:56 Export PDF Favorites Scan
  • TREATMENT OF TRAUMATIC SOFT TISSUE DEFECT BY VACUUM SEALING

    OBJECTIVE: To investigate the clinical effect of vacuum sealing in treatment of traumatic soft tissue defect. METHODS: From 1998. 8 to 2001. 2, 49 patients with 55 traumatic soft tissue defects were treated by vacuum sealing after debridement. Among them, there were 39 males and 10 females with mean age 38. 4 years. The wound area varied from 10 cm x 10 cm to 30 cm x 30 cm. In the experimental group, the wound surfaces or cavities were filled with polyvinyl alcohol foams with embedded drainage tubes connected with vacuum bottle (negative pressure of 50-60 kPa). Wound closure was performed with secondary suturing, or skin transplantation, or local flap grafting after 5-7 days. Besides, 126 patients were managed by traditional dressing as the control group. RESULTS: Out of 51 traumatic soft tissue defects (45 patients), the wound closure was performed with a free flap in 4, with local flap in 8, with skin grafting in 27, with secondary suturing in 6, and with vacuum sealing directly in the other 6 defects. Forty-five patients recovered and no complications (systemic and located) occurred. There were significant differences in time of secondary suturing, times of dressing, wound shrink and total therapeutic cost between two groups (P lt; 0.01). CONCLUSION: Vacuum sealing can protect the wound against contamination, evacuate the wound exudates completely, stimulate the growth of granulation tissue, and facilitate the wound healing; so vacuum sealing is a simple and effective method in treatment of traumatic soft tissue defect.

    Release date:2016-09-01 10:15 Export PDF Favorites Scan
  • REPAIR OF ACUTE RUPTURE OF FLEXOR TENDON BY RECONSTRUCTION OF DIGITAL SHEATH WITH BIOLOGICAL MEMBRANE

    Seventeen cases involving 18 fingers of acute rupture of flexor tendon within the Zone Ⅱ were repaired by microsurgical technique for reconstructing the digital sheath with biological membrane since 1989. The excellent/good rate based on Eaton grading was 89%. The main procedure of the operation. the early postoperative rehabilitation and active excercises were described.

    Release date:2016-09-01 11:33 Export PDF Favorites Scan
  • Ultrasonography on eyes with silicon oil tamponade

    Objective To investigate the characteristics of ultrasonogram of eyes with silicon oil tamponade. Methods Forty-seven patients (47 eyes) who had undergone the operation of silicon-oil removing were examined by A-(to determine the length of ocular axis) and B-scan before and after the operation respectively. The length of ocular axis and cubage of vitreous chamber were detected and the characteristics of the ultrasonograms were observed according to the default parameters of ultrasonograph. Results The results of A-scan showed that the preoperative axial length was 1.465 times of the postoperative one in the eyes without lens, and 1.284 times in eyes with lens; after modified the parameter according to the acoustic velocity, the preoperative axial length was (0.78±0.34) mm longer than the postoperative one in the eyes without lens, and (0.56±0.32) mm in eyes with lens. The results of A-scan showed that the cubage of vitreous chamber enlarged obviously in eyes with silicon oil tamponade, and the acoustic features included complete filling and partial filling according to the amount of silicon oil. Several arc echoes at the posterior segment of eye were detected in the silicon-oil-filling eyes with retinal detachment. Conclusion In the silicon-oil-filling eyes with lengthened ocular axis, the characteristics of B-scan images are affected by acoustic velocity through silicon oil, the amount of silicon oil capacity and the emulsification of silicon oil. (Chin J Ocul Fundus Dis,2004,20:349-351)

    Release date:2016-09-02 05:58 Export PDF Favorites Scan
  • 胸主动脉瘤及主动脉夹层外科治疗进展

    胸主动脉瘤及主动脉夹层病情凶险,死亡率和病残率均很高.近几年在保留和不保留主动脉瓣的主动脉根重建术治疗升主动脉瘤,弓部主动脉瘤切除与脑保护,胸主动脉瘤或胸腹主动脉瘤切除与脊髓保护,以及主动脉腔内支架移植术等方面取得了较大的进展.手术死亡率已从31.4%下降至3.3%~4.8%.胸主动脉瘤,特别是主动脉夹层系一全身性主动脉病变,近年来手术疗效有所改善,但远期复发率和再手术率仍较高.主动脉内支架移植与外科手术结合应用,对复杂的伴有降主动脉病变的A型主动脉夹层治疗,可能是一种安全而有效的方法.

    Release date:2016-08-30 06:30 Export PDF Favorites Scan
  • Mitral Valvuloplasty for the Treatment of Mitral Regurgitation

    Abstract: Compared with mitral valve replacement, there areseveral advantages in mitral valvuloplasty, so recently more and more sights are caught on mitral valve repair. According to different etiology, the surgeon can apply annuloplasty, triangular resection, quadrangular resection, replacement or transposition of chordae tendineae and so on to treat mitral regurgitation(MR). With the development of minimally invasive surgical technology, robotic mitral valve reconstruction evolve rapidly and percutaneous interventional therapy also commence from lab to bedside.We believe surgeons can repair MR safely and successfully in the majority of patients with proficiency in the basic techniques.

    Release date:2016-08-30 06:08 Export PDF Favorites Scan
  • Reflections on the construction of the evidence body of technical evaluation of functional foods after market introduction

    Interpretation of the complete scientific connotation of functional foods accurately prior to approval and registration based on animal tests and small sample size human food tests is challenging. Further technical evaluation after market introduction should be carried out on safety, health function and other aspects of those widely used commercial scale production products. According to the analysis report on the consumption situation of post-marketing population submitted when applying for product registration extension since the implementation of the functional food registration and filing management measures more than 3 years ago, the post-marketing evaluation report of functional food still lacks systematic and perfect evidence support. Based on the successful experience of evidence-based medicine and post-marketing evaluation evidence, this paper analyzes the post-marketing evaluation content, evidence source construction, evidence classification and classification of functional food, and puts forward the preliminary idea of constructing post-marketing evaluation evidence body of functional food safety and health function technology from multiple view points, so as to provide insights into evidence system research in this field in the future.

    Release date:2020-12-25 01:39 Export PDF Favorites Scan
  • Surgical treatment of retrograde type A aortic dissection after thoracic endovascular aortic repair for Stanford type B aortic dissection

    Objective To analyze the etiologies, surgical treatment and outcomes of retrograde type A aortic dissection (RTAD) after thoracic endovascular aortic repair (TEVAR) for Stanford type B aortic dissection. Methods The clinical data of patients with RTAD after TEVAR for Stanford type B aortic dissection receiving operations in Changhai Hospital from March 2014 to August 2018 were analyzed. All patients were followed-up by clinic interview or telephone. Results A total of 16 patients were enrolled, including 13 males and 3 females with a mean age of 49.1±12.2 years. The main symptoms of RTAD were chest pain in 12 patients, headache in 1 patient, conscious disturbance in 1 patient, and asymptomatic in 2 patients. All the 16 patients received total arch replacement with the frozen elephant trunk technique. Bentall procedure was used in 2 patients, aortic root plasticity in 10 patients and aortic valve replacement in 1 patient. The primary tear in 10 patients was located in the area which were anchored by bare mental stent, and in the other 6 patients it was located in the anterior part of ascending aorta. The mean cardiopulmonary bypass time was 152.2±29.4 min, aortic cross-clamping time was 93.6±27.8 min and selective cerebral perfusion time was 29.8±8.3 min. There was no death in hospital or within postoperative 30 days. The follow-up period was 32-85 (57.4±18.3) months. No death occurred during the follow-up period. One patient underwent TEVAR again 3 years after this operation and had an uneventful survival. Conclusion Total arch replacement with the frozen elephant trunk technique is a suitable strategy for the management of RTAD after TEVAR for Stanford type B aortic dissection.

    Release date:2023-09-27 10:28 Export PDF Favorites Scan
  • Survival assessment regarding vascularized osseous flaps on reconstruction for mandibular defect: a Bayesian network meta-analysis

    ObjectiveTo systematically review the survival rate of different vascularized bone flaps in mandibular defect repair and reconstruction by Bayesian network meta-analysis. MethodsThe PubMed, EBSCO, Scopus, Web of Science, Cochrane Library, WanFang Data and CNKI databases were electronically searched to collect clinical studies related to the objectives from inception to February 2024. Two reviewers independently screened literature, extracted data and assessed the risk of bias of the included studies. The Bayesian network meta-analysis was carried out applying R software. ResultsA total of 24 studies involving 1 615 patients were included. The results of meta-analysis showed that the respective survival rates of fibula free flap (FFF), deep circumferential iliac artery flap (DCIA), scapula flap, and osteocutaneous radial forearm flap (ORFF) were 95.62%, 94.09%, 98.16%, and 93.75%. Moreover, the network meta-analysis failed to show a statistically significant difference between all comparators. Conclusion Current evidence shows that different vascularized bone flaps have similar survival rates in mandibular defect repair and reconstruction. Due to the limited quality and quantity of the included studies, more high quality studies are needed to verify the above conclusion.

    Release date:2025-01-21 09:54 Export PDF Favorites Scan
  • Application of virtual reality technology in low vision teaching

    Objective To explore the application effect of virtual reality (VR) technology in low vision teaching for optometry students. Methods Undergraduate students majoring in optometry at West China School of Medicine of Sichuan University were selected as the research subjects. The students enrolled in 2020 adopted the traditional lecture-based learning (LBL) teaching mode (LBL teaching group), while the students enrolled in 2021 adopted the VR teaching mode (VR teaching group). Both groups of students studied the content of the same chapter on low vision, completed in-class tests after learning, and completed a questionnaire survey. Results There were 28 students in the VR teaching group and 30 students in the LBL teaching group. There was no statistically significant difference in age or gender composition between the two groups of students (P>0.05). The in-class test scores of students in the VR teaching group were higher than those in the LBL teaching group (86.43±6.10 vs. 78.10±7.69, P<0.05). Except for “subjective discomfort with this teaching mode”, the differences in other evaluation results between the two groups were statistically significant (P<0.05). VR teaching group students generally believed that applying VR technology to low vision teaching helped understand the visual experience and daily life status of low vision patients, improved learning efficiency and hands-on ability, reduced learning burden, and hoped to use this teaching mode routinely in other subject teaching. All students in the VR teaching group believed that this teaching mode was interesting, highly innovative, and enhanced teacher-student interaction.Conclusions Applying VR technology to low vision teaching can enable students to personally experience the impact of various diseases on patients’ visual function and daily life. This teaching method not only optimizes and improves teaching effectiveness, but also has a high acceptance rate among students, which is worth further promoting in future optometry teaching.

    Release date:2024-10-25 01:48 Export PDF Favorites Scan
98 pages Previous 1 2 3 ... 98 Next

Format

Content