west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "撕脱骨折" 37 results
  • A comparative study of absorbable screw fixation and absorbable screw combined with suture anchor fixation in treatment of avulsion fracture of posterior cruciate ligament at tibial insertion of knee joint

    ObjectiveTo compare the effectiveness of open reduction of posterior cruciate ligament (PCL) avulsion fracture at tibial insertion of knee joint with absorbable screws fixation and absorbable screw combined with suture anchor fixation. Methods The clinical data of 26 patients with PCL avulsion fracture at tibial insertion who met the selection criteria between March 2015 and October 2021 were retrospectively analyzed. Among them, 14 patients were fixed with simple absorbable screw (group A), and 12 patients were fixed with absorbable screw combined with suture anchors (group B). All patients were confirmed by X-ray film, CT, or MRI preoperatively, and got positive results in preoperative posterior drawer tests. There was no significant difference in gender, age, side of affected limb, time from injury to operation, comorbidities, and preoperative Meyers & McKeever classification, Lysholm score, and International Knee Documentation Committee (IKDC) score between the two groups (P>0.05). The operation time and postoperative complications were recorded and compared between the two groups. At last follow-up, Lysholm score and IKDC score were used to evaluate the improvement of knee function. ResultsThere was no significant difference in operation time between the two groups (P>0.05). All incisions healed by first intention, and no complication such as vascular and nerve injury or venous thrombosis occurred. All 26 patients were followed up 9-89 months, with an average of 55.3 months. The follow-up time of group A and group B was (55.7±23.2) and (56.8±29.3) months, respectively, with no significant difference (t=−0.106, P=0.916). Radiographs showed bone healing in both groups at 3 months after operation, and no complication such as infection and traumatic arthritis occurred. At last follow-up, the posterior drawer test was negative in both groups, and the Lysholm score and IKDC score significantly improved when compared with the pre-operative values (P<0.05). However, there was no significant difference in the improvement value between the two groups (P>0.05). ConclusionFor PCL avulsion fracture at tibial insertion of the knee joint, the open reduction and absorbable screw combined with suture anchor fixation can achieve reliable fracture reduction and fixation, which is conducive to the early rehabilitation and functional exercise, and the postoperative functional recovery of the knee joint is satisfactory.

    Release date:2023-05-11 04:44 Export PDF Favorites Scan
  • The Efficacy Analysis of Treatment of Medial Avulsion Fraction and Patellofemoral Ligament Injury of Patella Following Acute Traumatic Patellar Dislocation with Anchor

    目的:探讨带线锚钉治疗急性创伤性髌骨脱位后髌骨内侧缘撕脱骨折伴内侧髌股韧带损伤的疗效。方法:自2003年9月至2008年7月共收治28例急性髌骨脱位后髌骨内侧缘撕脱骨折伴内侧髌股韧带损伤患者。对28例患者均采用开放手术下带线锚钉固定髌骨骨折及修复内侧髌股韧带损伤。术后1年进行术后的髌骨骨折Levack功能评分。结果:所有患者术后随访时间12~30个月,平均(16±3.50)个月。术后1年的髌骨骨折Levack功能评分标准优23例,可3例,差2例,优秀率达82.14%。无再次髌骨脱位或伴脱位患者。结论:开放手术下带线锚钉治疗对髌骨骨折固定及内侧髌股韧带修复可靠,是治疗急性创伤性髌骨脱位后髌骨内侧缘撕脱骨折伴内侧髌股韧带损伤的有效方法。

    Release date:2016-09-08 10:12 Export PDF Favorites Scan
  • 自制齿状钩钢板治疗后交叉韧带胫骨止点撕脱骨折

    目的总结自制齿状钩钢板治疗后交叉韧带(posterior cruciate ligament,PCL)胫骨止点撕脱骨折的疗效。 方法2012 年 11 月—2016 年 4 月,采用自制齿状钩钢板治疗 PCL 胫骨止点撕脱骨折 11 例。其中男 6 例,女 5 例;年龄 37~63 岁,平均 48.5 岁。致伤原因:交通事故伤 4 例,高处坠落伤 2 例,跌伤 5 例;均为新鲜骨折,受伤至手术时间 3~11 d,平均 5.2 d。骨折按 Meyer-McKeever 分型:Ⅱ型 4 例,Ⅲ型 7 例。术前膝关节屈曲活动度 40~90°,平均 65.9°。术前 Lysholm 评分 50~69 分,平均 58.5 分。 结果术后切口均Ⅰ期愈合。11 例患者均获随访,随访时间 6~20 个月,平均 11 个月。术后 3 个月 X 线片示患者骨折均愈合,骨折端无明显移位。术后 6 个月,患肢膝关节屈曲活动度达 115~130°,平均 121.8°;膝关节后抽屉试验均呈阴性,未见膝关节伸直功能障碍及腘窝部血管、神经损伤并发症;Lysholm 评分为 85~99 分,平均 92.8 分。 结论自制齿状钩钢板治疗 PCL 胫骨止点撕脱骨折可行,操作简便、固定效果可靠,术后疗效满意。

    Release date:2017-06-15 10:04 Export PDF Favorites Scan
  • EFFECTIVENESS COMPARISON OF TWO ARTHROSCOPIC DIFFERENT FIXATIONS FOR ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURES

    Objective To compare the effectiveness of arthroscopic screw and suture fixations in treatment of anterior cruciate ligament tibial eminence avulsion fractures. Methods Between January 2002 and January 2009, 43 patients with freshanterior cruciate ligament tibial eminence avulsion fracture were treated, which were rated as types II and III according to Meyers- McKeever-Zaricznyj classification. Fractures were fixed with either screw (screw group, n=21) or nonabsorbable suture (suture group, n=22). There was no significant difference in sex, age, disease duration, and fracture type between 2 groups (P gt; 0.05). The range of motion (ROM) and Lysholm score were compared between 2 groups, and the knee stabil ity was evaluated based on the Lachman test and KT-2000 measurement. Results The operation time was 48-60 minutes (mean, 51.6 minutes) in the screw group, and 55-68 minutes (mean, 63.2 minutes) in the suture group, showing significant difference (t=4.645, P=0.032). Incisions healed by first intention and no compl ication occurred in 2 groups. All patients were followed up (5.7 ± 0.6) years in the screw group and (5.3 ± 0.5) years in the suture group. The fracture healed completely in both groups; the heal ing time was (3.3 ± 0.6) months in the screw group and (3.2 ± 0.4) months in the suture group, showing significant difference (t=3.723, P=0.019). Between the screw group and the suture group, no significant difference was found in ROM [(128.6 ± 10.1)° vs. (130.2 ± 14.1)°, P gt; 0.05] and Lysholm score (94.6 ± 14.5 vs. 95.1 ± 17.2, P gt; 0.05). The stabil ities based on KT-2000 measurement were also similar between 2 groups at last follow-up [(0.9 ± 0.3) mm vs. (1.0 ± 0.4) mm, P gt; 0.05]. Lachman test of 2 groups were negative. Conclusion Boththe screw and nonabsorbable suture fixation techniques for anterior cruciate l igament tibial eminence avulsion fracture (type II or III) have good results in terms of functional outcome and stabil ity. However, some patients show flexion contractures of 5° or 10°.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • Effectiveness analysis of minimally invasive safe approach to knee joint for treatment of avulsion fractures of tibial insertion of posterior cruciate ligament

    Objective To analyze the effectiveness of minimally invasive safe approach of the knee joint in the treatment of avulsion fractures of the tibial insertion of the posterior cruciate ligament (PCL). Methods The clinical data of 26 patients with avulsion fractures of tibial insertion of PCL treated with open reduction and internal fixation via minimally invasive safe approach of the knee joint between February 2019 and March 2022 were analyzed retrospectively. There were 18 males and 8 females with an average age of 45.5 years (range, 33-58 years). The causes of injury were traffic accident in 14 cases, falling from height in 7 cases, and sports injury in 5 cases. There were 15 cases of left knee and 11 cases of right knee. The preoperative Lysholm score of knee joint was 34.4±7.3 and the flexion range of motion of knee joint was (69±12)°. According to Meyers classification, there were 8 cases of type Ⅱ and 18 cases of type Ⅲ. The time from injury to operation ranged from 1 to 5 days, with an average of 2 days. ResultsThe operation time was 40-70 minutes, with an average of 55 minutes; the intraoperative blood loss was 10-30 mL, with an average of 15 mL. Delayed incision healing occurred in 1 case after operation, and the incision healed after conservative treatment, and the incisions of the other patients all healed by first intention. Postoperative X-ray films showed satisfactory fracture reduction. All 26 patients were followed up 3-30 months, with an average of 22 months. No complication such as neurovascular injury, infection, and knee extension disorder occurred after operation. X-ray films at 3 months after operation showed that all fractures healed without displacement of the fracture ends; the posterior drawer test was negative. At last follow-up, the flexion range of motion of knee joint was (120±9)°, the Lysholm score was 90.7±3.8, which were significantly improved when compared with those before operation (t=16.376, P<0.001; t=47.665, P<0.001). Conclusion The minimally invasive safe approach of the knee joint for the treatment of PCL tibial insertion avulsion fractures is easy to operate, with minimal surgical trauma, safe and reliable approach, and satisfactory recovery of knee joint function after operation.

    Release date:2023-02-13 09:57 Export PDF Favorites Scan
  • Treatment of Wehbe-Schneider typesⅠB and ⅡB bony mallet fingers with one-stage closed reduction and elastic compression fixation with double Kirschner wires

    Objective To investigate the effectiveness of one-stage closed reduction and elastic compression fixation with double Kirschner wires for Wehbe-Schneider types ⅠB and ⅡB bony mallet fingers. Methods Between May 2017 and June 2020, 21 patients with Wehbe-Schneider type ⅠB and ⅡB bony mallet fingers were treated with one-stage closed reduction and elastic compression fixation using double Kirschner wires. There were 15 males and 6 females with an average age of 39.2 years (range, 19-62 years). The causes of injury were sports injury in 9 cases, puncture injury in 7 cases, and sprain in 5 cases. The time from injury to admission was 5-72 hours (mean, 21.0 hours). There were 2 cases of index finger injury, 8 cases of middle finger injury, 9 cases of ring finger injury, and 2 cases of little finger injury. The angle of active dorsiflexion loss of distal interphalangeal joint (DIPJ) was (40.04±4.02)°. According to the Wehbe-Schneider classification standard, there were 10 cases of typeⅠB and 11 cases of type ⅡB. The Kirschner wire was removed at 6 weeks after operation when X-ray film reexamination showed bony union of the avulsion fracture, and the functional exercise of the affected finger was started. Results The operation time was 35-55 minutes (mean, 43.9 minutes). The length of hospital stay was 2-5 days (mean, 3.4 days). No postoperative complications occurred. All patients were followed up 6-12 months (mean, 8.8 months). X-ray films reexamination showed that all avulsion fractures achieved bony union after 4-6 weeks (mean, 5.3 weeks). Kirschner wire was removed at 6 weeks after operation. After Kirschner removal, the visual analogue scale (VAS) score of pain during active flexion of the DIPJ was 1-3 (mean, 1.6); the VAS score of pain was 2-5 (mean, 3.1) when the DIPJ was passively flexed to the maximum range of motion. The angle of active dorsiflexion loss of affected finger was (2.14±2.54)°, showing significant difference when compared with preoperative angle (t=52.186, P<0.001). There was no significant difference in the active flexion angle between the affected finger (79.52±6.31)° and the corresponding healthy finger (81.90±5.36)° (t=1.319, P=0.195). At 6 months after operation, according to Crawford functional evaluation criteria, the effectiveness was rated as excellent in 11 cases, good in 9, and fair in 1, with an excellent and good rate of 95.24%. Conclusion For Wehbe-Schneider typesⅠB and ⅡB bony mallet fingers, one-stage closed reduction and elastic compression fixation with double Kirschner wires can effectively correct the deformity and has the advantages of simple surgery, no incision, and no influence on the appearance of the affected finger.

    Release date:2022-05-07 02:02 Export PDF Favorites Scan
  • Effectiveness of three-needle and two-cable structure in treatment of inferior patellar pole avulsion fractures

    Objective To investigate the effectiveness of three-needle and two-cable structure in the treatment of inferior patellar pole avulsion fractures. Methods A clinical data of 62 patients with inferior patellar pole avulsion fractures who were admitted between January 2023 and December 2023 and met the selection criteria was retrospectively analyzed. Among them, the fractures were fixed with three-needle and two-cable structure in 32 patients (observation group) and traditional steel wire tension band in 30 cases (control group). There was no significant difference in the baseline data of age, gender, side of the affected limb, cause of injury, and disease duration between the two groups (P>0.05). The operation time, fracture healing and healing time, patellar height (Insall-Salvati index), occurrence of complications, knee range of motion, and Böstman score at last follow-up were compared between the two groups. Results The operation time of the observation group was significantly shorter than that of the control group (P<0.05). Patients in both groups were followed up 6-12 months (mean, 10.4 months). X-ray films re-examination showed that all fractures healed, and the fracture healing time was significantly shorter in observation group than in control group (P<0.05); no significant difference was found in Insall-Salvati index between the two groups (P>0.05). During follow-up, the complications occurred in 2 cases (6.25%) of observation group and in 9 cases (30.00%) of control group, and the difference in the incidences between the two groups was significant (P<0.05). At last follow-up, the range of motion and Böstman score of the knee joint in observation group were significantly superior to control group (P<0.05). Conclusion Compared with the traditional steel wire tension band fixation, the three-needle and two-cable structure fixation of the inferior patellar pole avulsion fractures is firm, which allows the knee joint to move early after operation and is conducive to the recovery of knee joint function.

    Release date:2025-06-11 03:21 Export PDF Favorites Scan
  • Arthroscopic suspension fixation with Endobutton in treatment of tibial insertion avulsion fractures of posterior cruciate ligament

    Objective To investigate the effectiveness of arthroscopic suspension fixation with Endobutton in the treatment of tibial insertion avulsion fractures of posterior cruciate ligament (PCL). Methods A retrospective analysis was conducted on the clinical data of 52 patients (52 knees) with tibial insertion avulsion fractures of PCL, who were treated by arthroscopic suspension fixation with Endobutton between June 2017 and October 2022. There were 29 males and 23 females, with an average age of 40.6 years (range, 19-66 years). There were 24 cases of traffic accident injuries, 17 cases of sports injuries, and 11 cases of fall injuries. The time from injury to operation ranged from 6 to 19 days (mean, 13.3 days). According to the Meyers-McKeever classification, there were 30 cases of type Ⅱ and 22 cases of type Ⅲ fractures. All patients exhibited positive posterior drawer test results. Preoperative knee joint function was assessed with Lysholm score (21.3±6.7), International Knee Documentation Committee (IKDC) score (20.7±5.8), and visual analogue scale (VAS) score (5.3±0.7); and knee joint range of motion was (41.73±3.17)°. Based on preoperative CT three-dimensional reconstruction measurements, the longitudinal diameter of the avulsed bone fragment ranged from 13 to 25 mm (mean, 18.1 mm). Operation time and occurrence of complications were recorded, and postoperative imaging was used to assess fracture healing. Knee joint function and pain severity were evaluated using knee joint range of motion, Lysholm score, IKDC score, and VAS score. Results The operation time ranged from 46 to 81 minutes (mean, 56.2 minutes). All patients were followed up 12-28 months (mean, 20.1 months). The iatrogenic fractures of bone fragments occurred during operation in 4 cases; and knee effusion occurred in 2 cases and anterior knee pain in 1 case after operation. All incisions healed by first intention. Imaging evaluations at 3 months after operation showed the fracture healing and no internal fixation failure. All patients demonstrated good knee function and had returned to normal activities at 12 months after operation. At last follow-up, the knee joint range of motion was (133.44±4.17)°, Lysholm score 93.6±3.1, IKDC score 93.4±2.5, and VAS score 1.0±0.6, with significant differences compared to preoperative scores (P<0.05). Conclusion Arthroscopic suspension fixation with Endobutton in the treatment of tibial insertion avulsion fractures of PCL is simple to operate, and the knee joint function recovers well.

    Release date:2024-03-13 08:50 Export PDF Favorites Scan
  • BIOMECHANICAL STUDY ON SUTURE WITH NECKWEAR-KNOT-LOOPLIGATURE FOR TIBIAL EMINENCE AVULSION FRACTURES

    ObjectiveTo study the biomechanical stability of neckwear-knot-loop-ligature fixation for tibial eminence avulsion fractures by comparing with cannulated screw fixation and suture anchor fixation. MethodsTwenty-four fresh porcine knee joints were selected. After the model of tibial eminence avulsion fracture (type Ⅲ) was made, 24 samples were randomly divided into 3 groups: neckwear-knot-loop-ligature group (group A), cannulated screw group (group B), and suture anchor group (group C), 8 samples in each group. The Universal electromagnetic and mechanical testing machines were used for the biomechanical tests. After 200 cyclic tests, pull-out test was done until fixation failure. The maximum failure load, yield load, stiffness, and displacement were measured. ResultsFailure mode: the displacement was beyond limit in 8 samples of group A; screws extraction (5 samples) and bone fragment re-fracture (3 samples) were observed in group B; and suture anchor extraction (4 samples), suture rupture (3 samples), and suture thread cutting (1 sample) were found in group C. Biomechanical test: From groups A to C, the maximum failure load and yield load showed significant decreasing tendency (P<0.05), but the displacements showed significant increasing tendency (P<0.05). The stiffness also gradually decreased, but differences was not significant (P>0.05). ConclusionCompared with cannulated screw and suture anchor, neckwear-knot-loop-ligature fixation for tibial eminence avulsion fracture has good biomechanical performance and the advantages of firm fixation and simple operation.

    Release date: Export PDF Favorites Scan
  • EFFECTIVENESS OF ARTHROSCOPIC TREATMENT OF ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURE WITH NON-ABSORBABLE SUTURE FIXATION COMBINED WITH MINI-PLATE

    Objective To evaluate the surgical techniques and effectiveness of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture with non-absorbable suture fixation combined with the mini-plate. Methods Between January 2009 and March 2012, 32 patients with ACL tibial eminence avulsion fractures were treated. There were 18 males and 14 females, aged 12-40 years (mean, 17.5 years). The injury causes included traffic accident injury in 15 cases, sport injury in 6 cases, and falling injury in 11 cases. The time from injury to operation ranged 7-18 days with an average of 9.5 days. Before operation, the results of Lachman test were all positive; the Lysholm score was 52.13 ± 4.22 and the International Knee Documentation Committee (IKDC) score was 44.82 ± 2.44. According to Meyers-McKeever classification criteria, there were 12 cases of type II and 20 cases of type III. After arthroscopic poking reduction of fracture, tibial eminence avulsion fractures were fixed with the Ethibond non-absorbable sutures bypass figure-of-eight tibial tunnel combined with the metacarpal and phalangeal mini-plate. Results Primary healing was obtained in all incisions; no joint infection or skin necrosis occurred after operation. All patients were followed up with an average time of 22.4 months (range, 12-50 months). The patients showed negative Lachman test at 12 weeks after operation. Except 3 patients having knee extension limitation at last follow-up, the knee extension range of motion (ROM) was normal in the other patients; the knee flexion ROM was normal in all patients. The Lysholm score and IKDC score were significantly improved to 94.19 ± 0.93 and 94.35 ± 1.22 at last follow-up, showing significant differences when compared with preoperative values (t=55.080, P=0.000; t=101.715, P=0.000). Conclusion The arthroscopic treatment of ACL tibial eminence avulsion fracture with Ethibond non-absorbable suture fixation combined with mini-plate is an effective procedure with the advantages of minimal trauma, reliable fixation, and satisfactory recovery of the knee joint function.

    Release date:2016-08-31 04:12 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content