ObjectivesTo investigate the influence of the abduction angle of the upper extremities on the image quality of non-enhanced CT scan and clinical value of the patients who cannot lift with double upper limbs by vehicle accident.Methods60 patients with double upper limbs that could not lift by vehicle accidents were required to receive liver non-enhanced CT scan, the patients were divided into 3 groups according to the abduction angle (group A, B, C), 20 cases in each group, another 20 cases with standard pose as the control group (group D). The CT value and standard deviation of the liver region of interest, the erector and the background air were measured, and the contrast to noise ratio of liver images, image noise value were calculated, together with the assessment of image quality and statistic analysis.ResultsThe liver non-enhanced CT scan were completed successfully. The image quality of group D was significantly better than A, B, C (Z=–10.753, P<0.05;Z=–11.645, P<0.05;Z=–12.281, P<0.05), respectively. Group C was better than A and B (Z=–8.502, P<0.05;Z=–4.068, P<0.05), respectively. Group B was better than A (Z=–5.885, P<0.05). The CNR of the four groups of images increased gradually, group A (0.09±0.77), group B (1.56±0.83), group C (2.51±0.87), group D (2.59±0.97), respectively. There were significant differences between four groups (F=36.323, P<0.05). The image noise decreased systematically, group A (14.84±2.94), group B (13.04±1.59), group C (11.60±1.72), group D (10.44±1.13), respectively. There were significant differences between four groups (H=426.755, P<0.05).ConclusionOn the premise of safety inspection, with the enlargement of angle of the upper limbs of patients who cannot lift with double upper limbs by vehicle accidents, the image noise decreased and image quality is improved with the increase of signal noise ratio.
ObjectiveTo evaluate the value of 70 kV and sonogram-affirmed iterative reconstruction technique in CT examination for children with congenital heart disease. MethodsThirty children with congenital heart disease who underwent CT scan between January and September 2014 were included in this study. According to the different tube voltage, they were randomly divided into group A (80 kV) and group B (70 kV), with fifteen in each. All the children were scanned on a dual-source-CT (Siemens Definition Flash). Group A used filtered back projection reconstruction. Group B used sonogram-affirmed iterative reconstruction. We measured and calculated the pulmonary artery signal-to-noise ratio at the level of main pulmonary artery window, the signal-to-noise ratio of the ascending aorta, noise ratio contrast between the pulmonary artery and erector spinae and between the ascending aorta and erector spinae. The image quality for congenital heart disease was assessed by two senior radiologists. The measurement of radiation dose included effective dose (ED), volume CT dose index (CTDIvol) and dose length product (DLP). ResultsThere were no significant differences between group A and B in terms of pulmonary artery signal-to-noise ratio (14.54±3.77, 11.23±2.52), the signal-to-noise ratio of the ascending aorta (14.76±3.41, 12.31±3.47), the noise ratio contrast between pulmonary artery and erector spinae (12.04±3.96, 9.18±3.76) and between the ascending aorta and erector spinae (12.47±4.59, 9.77±4.41) (P > 0.05). There was significant difference between group A and group B in CTDIvol[(0.53±0.09), (0.38±0.03) mGy], DLP[(12.93±1.79), (6.67±0.72) mGy·cm], and ED[(0.34±0.05), (0.17±0.02) mSv] (P < 0.05). ConclusionThe application of 70 kV and sonogram-affirmed iterative reconstruction technique in CT examination for children with congenital heart disease can significantly reduce the radiation dose without any influence on image quality.
目的 探讨常规注射速率下单倍剂量对比剂在颈部三维对比增强磁共振血管成像(3D-CEMRA)中的可行性及临床应用价值。 方法 2011年8月-11月,连续纳入30例临床怀疑颈动脉或椎动脉狭窄并要求颈部磁共振血管成像检查的患者,随机分成A、B两组(每组各15例)。使用西门子Magnetom Avanto 1.5 T磁共振成像仪及其配备的颈部线圈和头部线圈进行CEMRA成像。A组使用双倍剂量对比剂(0.2 mmol/kg),B组使用单倍剂量对比剂(0.1 mmol/kg)。用三维快速小角度激发序列进行颈部血管成像。由2位有丰富经验的高年资医生对两组原始图像的信噪比以及最大密度投影(MIP)图像的质量进行评价,并对结果进行统计学分析和处理。 结果 A、B两组的所颈动脉信噪比分别为189.95 ± 71.31、175.07 ± 68.61,差异无统计学意义(t=?0.566,P=0.576);所得的MIP图像质量均达到优良,差异无统计意义(χ2=0.180,P=0.671)。 结论 与双倍剂量相比,单倍剂量对比剂获得颈部血管的图像清晰,能够满足临床诊断要求。
ObjectiveTo summarize the methods and research progress of imaging evaluation of liver iron concentration.MethodsThe current status and progress of different imaging techniques in liver iron overload research were reviewed by studying the relevant literatures at home and abroad. The methods for determining liver iron concentration and their advantages and disadvantages were summarized.ResultsThe imaging methods for determining liver iron concentration mainly included traditional non-enhanced CT and dual energy CT examination, magnetic resonance signal intensity ratio, relative signal intensity index, T2 and R2 values, magnetic resonance spectroscopy, T2* and R2* values, susceptibility weighted imaging, and quantitative susceptibility mapping.ConclusionLiver iron quantification imaging method, including dual-energy CT and magnetic resonance imaging could non-invasively and accurately assess the liver iron overload.
目的 探讨多层螺旋CT在评价颈动脉斑块特征中的价值。 方法 回顾性分析2011年7月-10月132例行CT颈部血管造影患者的影像资料。对颈动脉斑块特征进行评价,重建方法包括多层面重建、容积再现技术、最大密度投影及曲面重建。 结果 132例患者中,80例检出颈动脉斑块,最常出现钙化斑块的部位为海绵窦段和床突上段,右侧海绵窦段52例(65.0%)、左侧海绵窦段49例(61.3%),右床突上段37例(46.3%)、左侧床突上段30例(37.5%)。最常出现软斑块的部位为双侧颈总动脉,均为12例(15.0%)。最常出现混合斑块的部位为颈总动脉,右侧颈总动脉9例(11.3%)、左侧颈总动脉12例(15.0%)。颈动脉最容易轻度狭窄294处(294/1 440,20.4%),中、重度狭窄少见,分别为8处(8/1 440,0.5%)和6处(6/1 440,0.4%)。颈部动脉血管斑块最易出现钙化,总计249处(249/1 440,17.3%),其次是软斑块和混合斑块,均为39处(39/1 440,2.7%)。 结论 多层螺旋CT可准确评价颈动脉斑块特征。
【摘要】 目的 评价64层螺旋CT低剂量冠状动脉血管成像的价值。 方法 2009年1-6月157例患者随机分为3组,常规剂量组(A组)管电流量采用1 000 mAs,两个低剂量组(B、C组)分别采用800、600 mAs。对3组的图像质量、噪声、CT剂量指数(CTDI)、剂量长度乘积(DLP)和有效剂量(ED)进行评估。 结果 A、B、C组图像噪声分别为20.50±3.23、23.02±3.05和26.28±2.58,组间差异均无统计学意义(Pgt;0.05);A、B、C组的CTDI分别为(58.7±0.23)、(46.98±2.27)、(35.28±3.56) mGy,DLP分别为(1 050.88±89.63)、(846.21±57.86)、(641.13±32.15) mGy?cm,ED分别为(14.78±2.56)、(11.85±1.87)、(8.98±1.15) mSv,B、C组的CTDI、DLP、ED均明显低于常规剂量A组(Plt;0.05),C组的CTDI、DLP、ED均为3组中最低值。 结论 64层螺旋CT冠状动脉血管检查,采用600 mAs管电流量获得的冠脉图像既可满足诊断需要,又可使患者接受的辐射剂量降低。【Abstract】 Objective To evaluate the best tube current for low-dose radiation CT in coronary artery imaging by 64-slices multi-detector CT. Methods From January to June 2009, a total of 157 consecutive patients were randomly divided into 3 groups: group A (conventional group): 1 000 mAs; group B: 800 mAs; group C: 600 mAs. The image quality, noise, CT dose index (CTDI), dose length product (DLP) and effective dose (ED) in each group were measured and compared respectively. Results The image noise scores in group A, B, and C were (20.50±3.23), (23.02±3.05) and (26.28±2.58), respectively. There was no statistically significant difference among the three groups in the two indexes (Pgt;0.05). The CTDI in group A, B and C were (58.7±0.23), (46.98±2.27), and (35.28±3.56) mGy, respectively; the DLP in each were (1 050.88±89.63), (846.21±57.86), and (641.13±32.15) mGy?cm, respectively; the Ed were (14.78±2.56), (11.85±1.87), and (8.98±1.15) mSv, respectively. All of the differences among the three groups in CTDI, DLP and ED were statistically significant (Plt;0.05). Conclusion The image with 600 mAs as tube current in the coronary artery imaging of 64-slices multi-detector CT could fulfill the need of the diagnosis, and the radiation dose is apparently lower than the conventional scan.