Objective To evluate the clinical outcome of autograftsof ilium and interbody fusion cage or bone morphogenetic protein(BMP)/artificial bone material/ cage in treating lumbar spondylolisthesis. Methods From January 1997 to January 2004,114 patients with lumbar spondylolisthesis were treated with posterior lumbar interbody fusion and pedicle screw fixation. There were 45 males and 69 females with an average age of 43 years ranging from 32 to 61 years. Of 114patients, 85 cases were classified as degree Ⅰ, 24 cases as degree Ⅱ and 5 cases as degree Ⅲ. The patients were divided into three groups accordingto the material used for interbody fusion: autografts of ilium (group A, n=42), interbody fusion cages(group B, n=36), and BMP/artificial bone material/ cage (group C, n=36).The clinical and radiographic results of the patients were compared among three groups. Results All patients were followed from 13 to 30 months with an average of 15 months. There were no statistically significant differences in surgical time, blood loss, and disc space height of preoperation(P>0.05) among three groups. No severe complication occurred in the three groups(P>0.05). The excellent and good rates in groups A,B and C were 81.0%, 80.6%, and 83.3% respectively, showing no statisticallysignificant difference(P>0.05).The fusion rate of group C(97.0%) was significantly higher than those of group A(81.0%) and group B(83.3%) (P<0.05) after 1 year of operation.And the average loss of disc space height in groups B and C was significantly lower than that in group A(P<0.05). Conclusion Higher fusion rate and lower loss of disc space height can beobtained in treating lumbar spondylolisthesis with BMP/artificial bone materiel.It is an effective method in the treatment of spondylolisthesis.
ObjectiveTo explore the effectiveness of nano-hydroxyapatite/polyamide-66 (n-HA/PA66) Cage in interbody fusion for degenerative lumbar scoliosis.MethodsA retrospective analysis was designed and conducted for 43 patients, who underwent posterior decompression and n-HA/PA66 Cage interbody fusion with correction of deformity between January 2013 and June 2016. Eighteen cases were single-level fusion (single-level group) and 25 cases were double-level fusion (double-level group). There was no significant difference in gender, age, body mass index, direction of convex, degree of apical rotation, fusion level, the number of osteoporotic patients, pre-operative intervertebral height of fusion segments, coronal Cobb angle, visual analogue score (VAS), and modified Oswestry Disability Index (ODI) between 2 groups (P>0.05). The operation time, intraoperative blood loss, postoperative drainage, hospital stay, and complications of the operation were recorded. Modified ODI, VAS score, and MacNab criteria were adopted to assess clinical outcomes. Radiographic indexes, including intervertebral height of fusion segments, coronal Cobb angle, disc insertion depth, and the bone graft fusion rate, were also evaluated.ResultsThere was no significant difference in operation time, intraoperative blood loss, postoperative drainage, and hospital stay between 2 groups (P>0.05). All patients were followed up 18-62 months (mean, 30.9 months). Wound complications, postoperative delirium, and Cage retropulsion occurred in 4 cases (2 cases in single-level group, 2 cases in double-level group), 1 case of single-level group, and 1 case of double-level group, respectively. The intervertebral height of fusion segments after operation significantly improved compared with preoperative ones in both groups (P<0.05). At last follow-up, the intervertebral height in double-level group was superior to which in single-level group (P<0.05). The coronal Cobb angles after operation significantly improved compared with preoperative ones (P<0.05), and no significant difference was found between 2 groups at each time point (P>0.05). The disc insertion depth showed no significant difference between different time points after operation in 2 groups (P>0.05) and between 2 groups at each time point after operation (P>0.05). Bony fusion was obtained in all patients at last follow-up. The VAS score and modified ODI after operation in both groups were superior to those before operation (P<0.05). The VAS score in double-level group was higher than that in single-level group (P<0.05) at last follow-up, and no significant difference was found in VAS score and modified ODI between 2 groups at other time points (P>0.05). According to the MacNab criteria, the excellent and good rates at last follow-up were 94.4% and 84.0% in single-level group and double-level group, respectively.ConclusionThe n-HA/PA66 Cage can effectively restore and maintain the disc height of fusion segment, normal sequence, and biomechanical stability of the spine, and gain favorable effectivenss for degenerative lumbar scoliosis. And double-level fusion is superior to single-level fusion in maintaining disc height of fusion segment.
ObjectiveTo summarize the advances in research on Cage subsidence following lumbar interbody fusion, and provide reference for its prevention.MethodsThe definition, development, clinical significance, and related risk factors of Cage subsidence following lumbar interbody fusion were throughout reviewed by referring to relevant domestic and doreign literature in recent years.ResultsAt present, there is no consensus on the definition of Cage subsidence, and mostly accepted as the disk height reduction greater than 2 mm. Cage subsidence mainly occurs in the early postoperative stage, which weakens the radiological surgical outcome, and may further damage the effectiveness or even lead to surgical failure. Cage subsidence is closely related to the Cage size and its placement location, intraoperative endplate preparation, morphological matching of disk space to Cage, bone mineral density, body mass index, and so on.ConclusionThe appropriate size and shape of the Cage usage, the posterolateral Cage placed, the gentle endplate operation to prevent injury, the active perioperative anti-osteoporosis treatment, and the education of patients to control body weight may help to prevent Cage subsidence and ensure good surgical results.
Objective To evaluate the safety and effectiveness of anterior cervical discectomy and fusion (ACDF) by using zero-profile anchored cage (ZAC) in treatment of consecutive three-level cervical spondylosis, by comparing with plate-cage construct (PCC). Methods A clinical data of 65 patients with cervical spondylosis admitted between January 2020 and December 2022 and met the selection criteria was retrospectively analyzed. During consecutive three-level ACDF, 35 patients were fixed with ZAC (ZAC group) and 30 patients with PCC (PCC group). There was no significant difference in baseline data between the two groups (P>0.05), including gender, age, body mass index, surgical segment, preoperative Japanese Orthopaedic Association (JOA) score, Neck Disability Index (NDI), visual analogue scale (VAS) score, prevertebral soft tissue thickness (PSTT), cervical lordosis, and surgical segmental angle. The operation time, intraoperative blood loss, hospital stay, clinical indicators (JOA score, NDI, VAS score), and radiological indicators (cervical lordosis, surgical segmental angle, implant subsidence, surgical segment fusion, and adjacent segment degeneration), and the postoperative complications [swelling of the neck (PSTT), dysphagia] were recorded and compared between the two groups. Results Patients in both groups were followed up 24-39 months. There was no significant difference in follow-up duration between the two groups (P>0.05). The operation time and intraoperative blood loss were lower in ZAC group than in PCC group, and the length of hospital stay was longer, but there was no significant difference (P>0.05). At each time point after operation, both groups showed significant improvements in JOA score, VAS score, and NDI compared with preoperative scores (P<0.05), but there was no significant difference between the two groups at each time point after operation (P>0.05). Both groups showed an increase in PSTT at 3 days and 3, 6 months after operation compared to preoperative levels (P<0.05), but returned to preoperative levels at last follow-up (P>0.05). The PSTT at 3 days and 3 months after operation were significantly lower in ZAC group than in PCC group (P<0.05), and there was no significant difference between the two groups at 6 months and at last follow-up (P>0.05). The incidences of dysphagia at 3 days and 3 months were significantly lower in ZAC group than in PCC group (P<0.05), while no significant difference was observed at 6 months and last follow-up between the two groups (P>0.05). There was no postoperative complication in both groups including hoarseness, esophageal injury, cough, or hematoma. Both groups showed improvement in cervical lordosis and surgical segmental angle compared to preoperative levels, with a trend of loss during follow-up. The cervical lordosis loss and surgical segmental angle loss were significantly more in the ZAC group than in PCC group (P<0.05). The incidence of implante subsidence was significantly higher in ZAC group than in PCC group (P<0.05). There was no significant difference between the ZAC group and PCC group in the incidences of surgical segment fusion and adjacent segment degeneration (P>0.05). ConclusionIn consecutive three-level ACDF, both ZAC and PCC can achieve satisfactory effectiveness. The former can reduce the incidence of postoperative dysphagia, while the latter can better maintain cervical curvature and reduce the incidence of implant subsidence.
Objective To compare the clinical outcomes of posterior lumbar interbody fusion(PLIF) using simple cage alone fusion with pedicle screw fixationand autogenous bone grafting and cage fusion with pedicle screw fixation in adult spondylolisthesis. Methods From March 2003 to March 2004,Twenty-seven patients with lumbar spondylolisthesis were divided in two groups. In group A, 15 patients were treated by PLIF using simple cage alone fusion with pedicle screw fixation, including 4 males and 11 females, aging 53-68 years. Isthmic defectswere located at L4 in 9 cases, at L5 in 6 cases. Four patients were smokers.Thepreoperative mean disc space height was 5.4±2.3 mm, the mean percentage of slip was 36.8%±7.2%. In group B, 12 patients were treated by PLIF using autogenous bone grafting and cage fusion with pedicle screw fixation, including 3 males and 9 females, aging 56 years. Isthmic defects were located at L4 in 8 cases, atL5 in 4 cases. Five patients were smokers. The preoperative mean disc space height was 5.7±2.5 mm, the mean percentage of slip was 37.8%±6.2%. Two groupswere compared in the amount of blood loss, duration of hospitalization, back pain, radiating pain, fusion rate, the intervertebral disc space height, the postoperative degree of slip and the fusion rate. Results All patientswere followed up for 24-38 months. The mean follow-up was 29(24-36) months in group A and26(24-38) months in group B. There were no statistically significant differences infollow-up period, age,sex, the location of isthmic defects, smoking, the preoperative disc space height and the percentage of slip between two groups (Pgt;0.05).There were no statistically significant differences in the amount of blood loss, the duration of hospitalization, the fusion time between two groups(Pgt;0.05). But there were statistically significant differences in the back pain score, the radiating pain score and the fusion rate between two groups(Plt;0.05).Thepo stoperative disc space height and the degree of slip of the last follow-up were5.8±2.2 mm and 25.6%±7.2% in group A, 6.2±2.5 mm and 24.1%±7.4 % ingroupB, showing statistically significant difference (Plt;0.05). Conclusion The PLIF using autogenous bone grafting and cage fusion with pedicle screw fixations ismore beneficial to improving the fusion rate and preventing longterm instabilities than simple cage alone fusion with pedicle screw fixation in adult spondylolisthesis.
ObjectiveTo compare the biomechanical differences between the kidney-shaped nano-hydroxyapatite/polyamide 66 (n-HA/PA66) Cage and the bullet-shaped n-HA/PA66 Cage. MethodsL2-L5 spinal specimens were selected from 10 adult male pigs. L2, L3 and L4, L5 served as a motor unit respectively, 20 motor units altogether. They were divided into 4 groups (n=5):no treatment was given as control group (group A); nucleus pulposus resection was performed (group B); bullet-shaped Cage (group C), and kidney-shaped Cage (group D) were used in transforaminal lumbar interbody fusion (TLIF) through left intervertebral foramen and supplemented by posterior pedicle screw fixation. The intervertebral height (IH) and the position of Cages were observed on the X-ray films. The range of motion (ROM) was measured. ResultsThere was no significant difference in the preoperative IH among 4 groups (F=0.166, P=0.917). No significant change was found in IH between at pre- and post-operation in group B (P>0.05); it increased after operation in groups C and D, but difference was not statistically significant (P>0.05). There was no significant difference in the postoperative IH among groups B, C, and D (P>0.05). The distance from Cage to the left margin was (3.06±0.51) mm in group C (close to the left) and (5.68±0.69) mm in group D (close to the middle), showing significant difference (t=6.787, P=0.000). The ROM in all directions were significantly lower in groups C and D than in groups A and B (P<0.05), and in group A than in group B (P<0.05). The right bending and compression ROM of group C were significantly higher than those of group D (P<0.05), but no statistically significant difference was found in the other direction ROM (P>0.05). ConclusionThe bullet-shaped and kidney-shaped Cages have similar results in restoring IH and maintaining the stability of the spine assisted by internal fixation. Kidney-shaped Cage is more stable than bullet-shaped Cage in the axial compression and the bending load opposite implant, it can be placed in the middle and back of the vertebral body more ideally.
Objective To evaluate the therapeutic effects of expandable pedicle screw (EPS) combined with interbody fusion cage on lumbar spondylolisthesis. Methods From June 2004 to March 2008, 23 patients with lumbar spondylolisthesiswere treated, including 9 males and 14 females aged 24-72 years old (average 48.7 years old). The course of the disease varied from 6 months to 6 years (average 30.4 months). There were 18 cases of degenerative spondylol isthesis and 5 of isthmic spondylolisthesis, including 1 case at L3,4 level, 14 at L4,5 level, and 8 at L5 and S1 levels. There were 17 cases of grade I, 4 of grade II, and 2 of grade III (including 1 case of recurrent L5 spondylolysis) according to Meyerding classification system. Posterior lumbar interbody fusion was performed using 48 PLIVIOS interbody fusion cages, and spondylolisthesis reduction and internal fixation were conducted using 84 pieces of EPS. The indications for use of EPS were initial operation with bone mass reduction or osteoporosis, reoperation of previous pedicle instrumentation, intraoperative screw relocation, sacral anchoring, and construct reinforcement. Cl inical outcomes, radiographic reduction of spondylol isthesis and bone fusion of lumbar interbody were evaluated based on JOA score, Boxall index, and Cook criteria. Results The incision healed by first intension in all cases except for one revision case that suffered from postoperative cerebrospinal fluid leakage and obtained delayed-healing without infection 23 days after operation using conservative treatment. No operative compl ications such as nerve and organ injuries were found.All cases were followed up for 12-39 months (average 17.8 months). X-ray exams of spine AP, lateral, fully extended position and fully flexed position view showed all 84 EPS were fully expanded within vertebral body. The improvement rate of JOA at the final follow-up visit was markedly effective in 14 cases, and effective in 5 cases, and noneffective in 4 cases, with a total effective rate of 82.61%. Anatomic reduction was achieved in 14 cases, improvement was obtained in 6 cases, no improvement was observed in 3 cases, and the reduction rate was 86.69%. Lumber interbody fusion was achieved in 20 cases, fixation was achieved in 2 cases, failure was observed in 1 cases, and the fusion rate was 86.69%. Conclusion EPS in complex with interbody fusion cage provides effective reduction, internal fixation and interbody fusion for the reconstruction of lumbar spondylolisthesis.
ObjectiveTo review the research progress and clinical application of allograft bone spacer in cervical and lumbar interbody fusion. MethodsLiterature about allograft bone spacer in cervical and lumbar degenerative disease was reviewed and analyzed, including the advantages and disadvantages of allograft material, fusion rate, effectiveness, and complications. ResultsFusion rate and effectiveness of allograft bone spacers were similar to those of autograft and polyetheretherketone spacers, and they were recommended by many orthopedists. However, indications, long-term effectiveness, and complications were not clear. ConclusionFurther study on allograft bone spacer in cervical and lumbar interbody fusion should be focused on optimal indications and long-term effectiveness.
Objective To summarize the basic research and the cl inical appl ication of biodegradable interbody fusion Cage. Methods Recent l iterature concerning biodegradable interbody fusion Cage at home and abroad was extensively reviewed, and current developments of the basic research and the cl inical appl ication of biodegradable interbody fusion Cage were investigated. Results Basic research showes that the stiffness of biodegradable interbody fusion Cage is lower than that of metall ic Cage, so it can enhance interbody fusion. As interbody fusion proceeded, biodegradable interbody fusion Cage degrades constantly, but the speed of degradation can not keep in parallel with that of fusion. In addition, the tissue response to degradation products is controversy. Cl inical appl ication showes that the biodegradable interbody fusion Cage can enhance interbody fusion and maintain disc space height. The short term results are good, however, the long term results need further observation. Conclusion Biodegradable interbody fusion Cage can effectively enhance interbody fusion.
Objective To compare the effectiveness between three-dimensional (3D) printed porous titanium alloy cage (3D Cage) and poly-ether-ether-ketone cage (PEEK Cage) in the posterior lumbar interbody fusion (PLIF). Methods A total of 66 patients who were scheduled to undergo PLIF between January 2018 and June 2019 were selected as the research subjects, and were divided into the trial group (implantation of 3D Cage, n=33) and the control group (implantation of PEEK Cage, n=33) according to the random number table method. Among them, 1 case in the trial group did not complete the follow-up exclusion study, and finally 32 cases in the trial group and 33 cases in the control group were included in the statistical analysis. There was no significant difference in gender, age, etiology, disease duration, surgical segment, and preoperative Japanese Orthopaedic Association (JOA) score between the two groups (P>0.05). The operation time, intraoperative blood loss, complications, JOA score, intervertebral height loss, and interbody fusion were recorded and compared between the two groups. Results The operations of two groups were completed successfully. There was 1 case of dural rupture complicated with cerebrospinal fluid leakage during operation in the trial group, and no complication occurred in the other patients of the two groups. All incisions healed by first intention. There was no significant difference in operation time and intraoperative blood loss between groups (P>0.05). All patients were followed up 12-24 months (mean, 16.7 months). The JOA scores at 1 year after operation in both groups significantly improved when compared with those before operation (P<0.05); there was no significant difference between groups (P>0.05) in the difference between pre- and post-operation and the improvement rate of JOA score at 1 year after operation. X-ray film reexamination showed that there was no screw loosening, screw rod fracture, Cage collapse, or immune rejection in the two groups during follow-up. At 3 months and 1 year after operation, the rate of intervertebral height loss was significantly lower in the trial group than in the control group (P<0.05). At 3 and 6 months after operation, the interbody fusion rating of trial group was significantly better in the trial group than in the control group (P<0.05); and at 1 year after operation, there was no significant difference between groups (P>0.05). ConclusionThere is no significant difference between 3D Cage and PEEK Cage in PLIF, in terms of operation time, intraoperative blood loss, complications, postoperative neurological recovery, and final intervertebral fusion. But the former can effectively reduce vertebral body subsidence and accelerate intervertebral fusion.