Objective To explore the method of the distal perforator-based gluteus maximus muscle V-Y flap to treat the sacral ulcer and to simplify the operative procedures.Methods From March 2002 to March 2005, 11 cases of sacral ulcer were repaired by distal perforatorbased gluteus maximus muscle flaps. The area of sacral ulcer ranged from 13 cm×11 cm to 18 cm×14 cm. Of 11 cases, 7 were female and 4 were male,whose age ranged from 21 to 69 years, and the disease course was 8 months to 3 years.A triangular flap was designed to create a V-Y advancement flap.The length of the base was made almost equal to the diameter of the defect.The apex of the tringle was located near the great trochanter. The medial part of the flap was elevated as a fasciocutaneous flap by dissecting the layer between the fascia and the muscle.The distal part ofthe flap was elevated by dissecting the layer between the gluteus maximus muscle and the fascia of the deeper muscle group.The flap was advanced to the defect. Results All the flaps survived. After a follow-up of 5 months to 3 years, the bilateral buttocks were symmetry and whose appearance was satisfactory. Except for 1 case dying of other disease, no recurrence of ulcer was observed.All the flaps survived. Conclusion The distal perforatorbased fasciocutaneous V-Y flap for treatment of sacral ulcers is a simple and reliable technique, which has several advantages over the conventional V-Y flap technique,such as excelent excursion,viable coverage with the fasciocutaneous component, high flap reliability, preservation of the contralateral buttock, and preservation of the gluteus maximus muscle function.
ObjectiveTo investigate the effectiveness of the free medial sural artery perforator flap for repairing anterior dorsal foot wound. MethodsBetween January 2010 and April 2015, 16 patients with skin and soft tissue defects of the anterior foot dorsal side were treated. There were 12 males and 4 females with the average age of 35 years (mean, 16-58 years). The disease causes included burn in 5 cases, traffic accident injury in 8 cases, and crush injury in 3 cases. The time from injury to admission was 2-30 hours (mean, 6.5 hours). The wound area ranged from 4 cm×3 cm to 10 cm×7 cm; combined injury included defects of lateral collateral ligament and joint capsule in 3 cases, and bone exposure in 12 cases, and all had exposure of tendon. Wounds were repaired with the medial sural artery perforator flap in 13 cases, and with medial sural artery perforator composite tissue flap carrying of medial head of gastrocnemius muscle flap in 3 cases. The size of flaps ranged from 5 cm×4 cm to 11 cm×8 cm. The donor site was sutured directly or was repaired with skin grafting. ResultsAll flaps survived well and wounds healed with stage I; skin grafts at donor site survived and the incision healed with stage I. All patients were followed up 6-36 months (mean, 11 months). The appearance of skin flap was satisfactory, without overstaffed; the joint of reconstructed ligament was stable, without secondary deformity. There was no obvious depression at the donor site, and no effect on the function. ConclusionThe medial sural artery perforator flap has the advantages of relatively constant perforator anatomy, reliable blood supply, and carries the gastrocnemius muscle flap for repair of compound tissue defect. It is one of better ways to repair the anterior dorsal foot wound.
ObjectiveTo investigate the effectiveness of free-style perforator flap in repairing the soft tissue defect of knee.MethodsBetween December 2011 and October 2017, 13 patients with the soft tissue defects of knees were repaired with the free-style perforator flaps. There were 9 males and 4 females, with an average age of 40 years (range, 14-65 years). The injuries were caused by traffic accident in 7 cases, crushing in 4 cases, and falling from height in 2 cases. The soft tissue defects in 9 cases formed after 2 weeks-2 months (mean, 1 month) of lower extremity fractures fixation. The other 4 cases were urgently admitted to the hospital after injury, and the time from injury to admission was 0.5-18.0 hours (mean, 8 hours). The size of soft tissue defect ranged from 3 cm×2 cm to 12 cm×8 cm after debridement. Nine propeller flaps, 6 rotating flaps, and 2 V-Y advanced flaps were used; and 9 cases were repaired by single flap and 4 cases were repaired by combined flaps. The size of flap ranged from 7.5 cm×2.5 cm to 20.0 cm×6.0 cm. The donor sites were sutured directly.ResultsThe flaps survived smoothly and incisions healed by first intention in 12 cases. The congestion occurred in 1 case, which obtained delayed healing after symptomatic treatment. All incisions at donor sites healed by first intention. All patients were followed up 3-24 months with an average of 6 months. The shape and motions of knee were satisfactory.ConclusionThe free-style perforator flap can maximize the utilization of the donor area around the knee wound, with reliable blood supply, small trauma, and easy operation. It is an ideal flap for the soft tissue defect of knee.
Objective To explore the application value of infrared thermography in the design and harvesting of ultrathin anterolateral thigh perforator flaps. Methods Between June 2024 and December 2024, 9 cases of ultrathin anterolateral thigh perforator flaps were designed and harvested with the assistance of infrared thermography. There were 7 males and 2 females, aged 21-61 years (mean, 39.8 years). The body mass index ranged from 19.49 to 26.45 kg/m² (mean, 23.85 kg/m²). Causes of injury included 5 cases of traffic accident injuries and 4 cases of machine crush injuries. There were 3 cases of leg wounds, 2 cases of foot wounds, and 4 cases of hand wounds. After debridement, the size of wound ranged from 7 cm×4 cm to 13 cm×11 cm. The time from admission to flap repair surgery was 5-12 days (mean, 7 days). Preoperatively, perforator localization was performed using a traditional Doppler flow detector and infrared thermography, respectively. The results were compared with the actual intraoperative locations; a discrepancy ≤10 mm was considered as consistent localization (positive), and the positive predictive value was calculated. All 9 cases were repaired with ultrathin anterolateral thigh perforator flaps designed and harvested based on thermographic images. The size of flap ranged from 8 cm×5 cm to 14 cm×8 cm, with a thickness of 3-6 mm (mean, 5.2 mm). One donor site was repaired with a full-thickness skin graft, and the others were sutured directly. Postoperatively, anti-inflammatory, anticoagulant, and anti-vascular spasm treatments were administered, and follow-up was conducted. ResultsThe Doppler flow detector identified 22 perforating vessels within the set range, among which 16 were confirmed as superficial fascia layer perforators intraoperatively, with a positive predictive value of 72.7%. The infrared thermograph detected 23 superficial fascia layer perforating vessels, and 21 were verified intraoperatively, with a positive predictive value of 91.3%. There was no significant difference between the two methods [OR (95%CI)=3.93 (0.70, 22.15), P=0.100]. The perforator localization time of the infrared thermograph was (5.1±1.3) minutes, which was significantly shorter than that of the Doppler flow detector [(10.1±2.6) minutes; MD (95%CI)=–5.00 (–7.08, –2.91), P<0.001]. Postoperatively, 1 case of distal flap necrosis healed after dressing change; all other flaps survived successfully. The skin grafts at donor site survived, and all incisions healed by first intention. All patients were followed up 3-6 months (mean, 4.7 months). No pain or other discomfort occurred at the donor or recipient sites. All patients with foot wounds could walk with shoes, and no secondary flap revision was required. Flaps in 3 hand wound cases, 2 foot wound cases, and 3 leg wound cases recovered light touch and pressure sensation, but not pain or temperature sensation; the remaining 2 cases had no sensory recovery.ConclusionPreoperative localization using infrared thermography for repairing ultrathin anterolateral thigh perforator flaps can help evaluate the blood supply status of perforators, reduce complications, and improve surgical safety and flap survival rate.
Objective To investigate the method, effectiveness, andclinical application of the anterolateral thigh perforator free flaps for reconstruction of the soft tissue defects in the head and the four limbs after tumorresection. Methods From April 2004 to April 2006, 16 patients (13 males, 3 females; aged 26-72 years) with the soft tissue defects in the head (9 patients) and the four limbs (7 patients) underwent reconstructive operations with the anterolateral thigh perforator free flaps after their tumor resection. The defects ranged in area from 8 cm×6 cm to 20 cm×13 cm in the head with the process of diseases from 6 to 24 months, and the defects ranged in area from 10 cm×7 cm to 21 cm× 12 cm in the four limbs with the process of diseases from 2 to 18 months.The technique for the anterolateral thigh perforator flap freegrafting, the degree of the injury in the donor sites, and the appearance of the donor and recipient sites, and the influence on the anatomy and function in the both local sites were analyzed. Results In the 16 patients with the soft tissue defects in the head and the four limbs after tumor resection, 14 had a primary wound healing (Stage Ⅰ), and 2 had a delayed wound healing (Stage Ⅱ) . Fifteen flaps survived completely but two flaps had a partial failure. Theflap appearance was good and smooth without any severe scarring, and there was a minimal effect on the function at the donor and recipient sites. Conclusion Because of the less morbidity at the donor site, the better result at the recipient site, and the use of the anterolateral thigh perforator flap free grafting, this kind of the technique for reconstruction of the head and fourlimb soft tissue defects after tumor resection is well acceptable.
Objective To investigate the effectiveness of dorsal perforator flap of cross-finger proper digital artery in the treatment of finger soft tissue defect caused by high-pressure injection injury. MethodsBetween July 2011 and June 2020, 14 cases of finger soft tissue defect caused by high-pressure injection injury were repaired with dorsal perforator flap of cross-finger proper digital artery. All patients were male, with a mean age of 36 years (range, 22-56 years). The defects were located on the index finger in 8 cases, middle finger in 4 cases, and ring finger in 2 cases. The causes of injury include 8 cases of emulsion paint injection, 4 cases of oil paint injection, and 2 cases of cement injection. The time from injury to debridement was 2-8 hours, with a mean time of 4.5 hours. The soft tissue defects sized from 4.0 cm×1.2 cm to 6.0 cm×2.0 cm. The flaps sized from 4.5 cm×1.5 cm to 6.5 cm×2.5 cm. The donor site of the flap was repaired with skin graft. The pedicle was cut off at 3 weeks after operation, and followed by functional exercise. ResultsAll flaps and skin grafts at donor sites survived, and the wounds healed by first intention. Twelve patients were followed-up 16-38 months (mean, 22.6 months). The texture and appearance of all flaps were satisfactory. The color and texture of the flaps were similar to those of the surrounding tissues. The two-point discrimination of the flap was 10-12 mm, with a mean of 11.5 mm. There were different degrees of cold intolerance at the end of the affected fingers. At last follow-up, the finger function was evaluated according to the Upper Extremity Functional Evaluation Standard set up by Hand Surgery Branch of Chinese Medical Association, 3 cases were excellent, 8 cases were good, and 1 case was poor. Conclusion The dorsal perforator flap of cross-finger proper digital artery can effectively repair finger soft tissue defect caused by high-pressure injection injury. The operation was simple, and the appearance and function of the finger recover well.
Objective To investigate the effectiveness of the deep inferior epigastric perforator (DIEP) flap for extreme defects around the knee. Methods Between June 2017 and December 2018, 15 patients with the extreme defects around the knee were admitted. There were 9 males and 6 females with a median age of 36 years (range, 23-51 years). The etiology was the traffic accident in 7 cases, tumor in 5 cases, and burn in 3 cases. The injured location was left knee in 8 cases and right knee in 7 cases. The size of soft tissue defects ranged from 15 cm×10 cm to 30 cm×20 cm, and all defects complicated with exposure of blood vessels, nerves, tendons, and other tissues. Transverse DIEP flaps with 1-2 vascular pedicles were prepared according to the size of the defect, including 6 cases of single-pedicle flaps and 9 cases of double-pedicle conjoined flaps. According to the depth of the defect, 10 cases of skin flaps were thinned under microscope. The size of the DIEP flaps ranged from 16 cm×10 cm to 32 cm×20 cm; the average thickness was 1.5 cm (range, 0.8-1.8 cm); the average pedicle length was 7.5 cm (range, 5.0-9.0 cm). The donor site was directly sutured. Results One single-pedicle flap developed distal necrosis after operation, and healed after skin grafting; the other skin flaps survived, and the wounds at the donor and recipient sites healed by first intention. All patients were followed up 16-28 months (mean, 24 months). The shape and texture of the flap were satisfactory, and there was no abnormal hair growth or obvious pigmentation. There was only linear scar at the donor site and no complication such as abdominal hernia. The appearance and function of the knee were satisfactory. No recurred tumor was observed, and the scar contracture was released. At last follow-up, 13 cases were excellent and 2 cases were good, according to the Knee Society Score (KSS) criteria. Conclusion The DIEP flap is an ideal alternative for repairing the extreme defects around knee, with a concealed donor site, easy dissection, flexible design, as well as less complication.
Objective To investigate the effectiveness of the wrap-around great toe flap combined with medial plantar artery perforator flap (MPAP) for repairing the completely degloved fingers. Methods Between February 2018 and December 2019, 12 patients with the completely degloved fingers caused by machine strangulation were admitted. There were 9 males and 3 females with a median age of 32 years (range, 18-42 years). The injured finger was index finger in 7 cases, middle finger in 3 cases, and ring finger in 2 cases. The skin was avulsed from the metacarpophalangeal joint level, with the intact tendon and joint. The interval between injury and admission was 1-8 hours (mean, 5 hours). All fingers were taken debridement during the emergency operation. The size of the skin defect ranged from 8.0 cm×5.0 cm to 12.0 cm×7.5 cm. After flap thinning, the wrap-around great toe flap (8.0 m×2.0 cm-12.0 cm×3.5 cm) and MPAP (8.0 cm×4.0 cm-12.0 cm×5.5 cm) were used to repair the degloved finger. The donor sites were repaired with the full-thickness skin graft or the flap. Results All flaps and skin grafts survived completely without significant complications and the wounds at recipient and donor sites healed by first intention. All patients were followed up 12-16 months (mean, 14 months). The texture, appearance, and color of the affected fingers were close to those of normal fingers, and the nails grew normally. At last follow-up, the mean two-point discrimination of the flap was 9 mm (range, 8-10 mm), and the sensation of the injured finger recovered to S3-S4. And 10 cases were rated as excellent and 2 cases as good according to the Michigan Hand Outcomes Questionnaire (MHQ). There was no complication such as pain from walking or skin ulceration at the donor site. The American Orthopaedic Foot and Ankle Society (AOFAS) score was excellent in 9 cases and good in 3 cases. Conclusion Treating for the completely degloved fingers, the wrap-around great toe flap combined with MPAP can obtain good effectiveness in the respect of the sensation, function, and appearance.
ObjectiveTo investigate the effectiveness of free sensate intercostal artery perforator flap for the hand soft tissue reconstruction.MethodsBetween March 2010 and September 2015, 19 cases of hand soft tissue defect were repaired with free sensate intercostal artery perforator flap, including 16 males and 3 females, aged from 18 to 53 years, with an average of 35.2 years. The defect was located in the dorsum of the hand in 15 cases and in the palm in 4 cases. The causes of injury were traffic accident injury in 8 cases, hot crush injury in 5 cases, strangulation injury in 4 cases, and avulsion injury in 2 cases. All of them were full-thickness skin and soft tissue defects of hand with exposure of phalanges, tendons, blood vessels, and nerves. The size of defect was 10.0 cm×7.0 cm to 17.0 cm×8.0 cm. There were 12 cases of emergency operation and 7 cases of selective operation. The thickness of flap was 10-25 mm, and the size of the flap ranged from 10.0 cm×7.5 cm to 17.0 cm×8.0 cm. The vascular pedicle of the flap was anastomosed with the snuff nest branch of the radial artery (12 cases), the main radial artery (7 cases), and there accompanying vein, and the intercostal nerve cutaneous branch of the flap was anastomosed with the lateral cutaneous nerve of the forearm. The donor site was closed directly (14 cases) or repaired with medium thickness skin graft (5 cases).ResultsAll of the flaps and skin grafts survived; the wounds in the donor and recipient sites healed by first intention. All 19 patients were followed up 10- 18 months, with an average of 12.7 months. After operation, the appearance and function of the hand recovered well, and there was no flap bloated. The two-point discrimination of the flap was 7-11 mm, with an average of 8.8 mm. Only linear scars left in the patients with direct closure of the donor site. The sensory function of the donor site was not significantly affected, and the hand function recovered satisfactorily. Conclusion Free sensate intercostal artery perforator flap is a valuable and reliable technique for the hand soft tissue defect.