ObjectiveTo compare the clinical efficacy and safety between percutaneous vertebroplasty (PVP) and percutaneous kyphoplasty (PKP) in the treatment of osteoporotic vertebral compression fracture (OVCF) with intravertebral vacuum cleft (IVC). MethodsBetween January 2010 and December 2013, 68 patients with single OVCF and IVC were treated, and the clinical data were retrospectively analyzed. Of 68 patients, 48 underwent PVP (PVP group) and 20 underwent PKP (PKP group). There was no significant difference in age, gender, disease duration, fracture level, bone mineral density (BMD), visual analogue scale (VAS), Oswestry disability index (ODI), and preoperative radiological parameters between 2 groups (P > 0.05). The intraoperative incidence of cement leakage, cement volume, and operative time were compared between 2 groups; VAS score was used for evaluation of back pain and ODI for evaluation of dysfunction; the incidence of adjacent vertebral fracture was observed within 2 years. The vertebral height and kyphotic angle were measured on X-ray films; the rate of vertebral compression (CR), reduction rate (RR), progressive height loss (PHL), reduction angle (RA), and progressive angle (PA) were calculated. ResultsThere was no significant difference in cement volume and the incidence of cement leakage between 2 groups (P > 0.05). The operative time in PVP group was shorter than that in PKP group, showing significant difference (t=-8.821, P=0.000). The mean follow-up time was 2.4 years (range, 2.0-3.1 years). The VAS scores and ODI were significantly reduced at 1 day, 1 year, and 2 years after operation when compared with preoperative scores (P < 0.05), but there was no significant difference between different time points after operation in 2 groups (P > 0.05). Adjacent vertebral fracture occurred in 5 cases (10.4%) of PVP group and in 2 cases (10.0%) of PKP group, showing no significant difference (χ2=0.003, P=0.963). BMD was significantly increased at 1 year and 2 years after operation when compared with preoperative BMD (P < 0.05), but no significant difference was found between 2 groups (t=0.463, P=0.642; t=0.465, P=0.646). The X-ray films showed that CR and kyphotic angle were significantly restored at immediate after operation in 2 groups (P < 0.05); but vertebral height and kyphotic angle gradually aggravated with time, showing significant difference between at immediate and at 1 and 2 years after operation (P < 0.05); there was no significant difference in CR and kyphotic angle between 2 groups at each time point (P > 0.05). RR, RA, PHL, and PA showed no significant difference between 2 groups (P > 0.05). ConclusionThere is similar clinical and radiological efficacy between PVP and PKP for treatment of OVCF with IVC. Re-collapse could happen after operation, so strict observation and follow-up are needed.
Objective To compare the effectiveness of arthroscopy assisted percutaneous internal fixation and open reduction and internal fixation for Schatzker types II and III tibial plateau fractures. Methods Between August 2006 and April 2010, 58 patients with tibial plateau fractures of Schatzker types II and III were treated with arthroscopy assisted percutaneous internal fixation (arthroscopy group, n=38), and with open reduction and internal fixation (control group, n=20). There was no significant difference in gender, age, disease duration, fracture type, and compl ication between 2 groups (P gt; 0.05). The operation time, incision length, fracture heal ing time, and compl ications were compared between 2 groups. Knee function score and the range of motion were measured according to American Hospital for Special Surgery (HSS) scorestandard. Results All patients achieved primary incision heal ing. The arthroscopy group had smaller incision length andlonger operation time than the control group, showing significant differences (P lt; 0.05). The patients of 2 groups were followed up 12 to 14 months. At 6 months, the HSS score and the range of motion of the arthroscopy group were significantly greater than those of the control group (P lt; 0.05). The X-ray films showed bony union in 2 groups. The fracture heal ing time of the arthroscopy group was shorter than that of the control group, but no significant difference was found (t=2.14, P=0.41). Morning stiffness occurred in 2 cases (5.3%) of the arthroscopy group, joint pain in 6 cases (30.0%) of the control group (3 cases had joint stiffness) at 1 week, which were cured after symptomatic treatment. There was significant difference in the incidence of compl ications between 2 groups (χ2=6.743, P=0.016). Conclusion The arthroscopy assisted percutaneous internal fixation is better than open reduction and internal fixation in the treatment of tibial plateau fractures of Schatzker types II and III, because it has smaller incision length and shorter fracture heal ing time.
Objective To assess the effectiveness and safety of different dual antiplatelet therapies in patients undergoing percutaneous coronary intervention. Methods Such databases as The Cochrane Library, MEDLINE, EMbase, CBM, CNKI and WanFang Data were searched to collect the randomized controlled trials (RCTs) and observational studies on the effectiveness and safety of dual antiplatelet therapies both short-duration (≤6 months) and long-duration (gt;6 months) after percutaneous coronary intervention. The literature was screened according to the inclusive and exclusive criteria by two reviewers independently, the quality was evaluated, the data were extracted, and meta-analyses were performed by using RevMan 5.1 software. Results Eight trials were included, of which 3 were RCTs involving 7 475 patients, and 5 were observational studies involving 12 744 patients. Meta-analyses on RCTs showed that the incidence of death or myocardial infarction in the long-duration treatment group was lower than that of the short-duration treatment group (OR=0.74, 95%CI 0.56 to 0.98, Plt;0.000 1), while meta-analyses on observation studies showed the similar result (OR=0.7, 95%CI 0.45 to 1.08, P=0.11). With the variables of published year and follow-up time, the heterogeneity of cohort studies was discussed through meta-regression (Z=3.61, P=0.000) which indicated that both published year and follow-up time might be the source of heterogeneity due to their contribution. For RCTs, the incidence of severe bleeding events in the short-duration treatment group was lower than that in the long-duration treatment group (OR=1.29, 95%CI 0.99 to 1.69, P=0.06). For observational studies, the incidence of late stent thrombosis in the long-duration treatment group was lower than that in the short-duration treatment group (OR=0.40, 95%CI 0.15 to 1.07, P=0.07). Conclusion The long duration (gt;6months) of dual antiplatelet therapy in patients undergoing percutaneous coronary intervention can reduce the incidence of death or myocardial infarction and decrease the tendency of late stent thrombosis, but cannot obviously increase the incidence rate of severe bleeding events. The current evidence shows no marked superiority in longer duration (gt;12months) of dual antiplatelet therapy.
ObjectiveTo compare the effectiveness and safety of electromagnetic navigation-guided localization and CT-guided percutaneous localization for pulmonary nodules.MethodsThe literature published from the inception to January 2021 about the comparison between electromagnetic navigation-guided localization and CT-guided percutaneous localization for pulmonary nodules in the PubMed, The Cochrane Library, Web of Science, EMbase, Chinese Wanfang database and CNKI database was searched. RevMan (version 5.4) software was used for meta-analysis. Nonrandomized controlled trials were evaluated using methodological index for nonrandomized studies (MINORS).ResultsA total of six retrospective studies (567 patients) were included in this meta-analysis. MINORS scores of all studies were all 17 points and above. There were 317 patients in the CT-guided percutaneous localization group and 250 patients in the electromagnetic navigation-guided localization group. The complication rate of the CT-guided percutaneous localization group was significantly higher than that in the electromagnetic navigation-guided localization group (OR=11.08, 95%CI 3.35 to 36.65, P<0.001). There was no significant difference in the success rate of localization (OR=0.48, 95%CI 0.16 to 1.48, P=0.20), localization time (MD=0.30, 95%CI –6.16 to 6.77, P=0.93) or nodule diameter (MD=–0.07, 95%CI –0.19 to 0.06, P=0.29) between the two groups.ConclusionElectromagnetic navigation can be used as an effective preoperative positioning method for pulmonary nodules, which has the advantage of lower complication rate compared with the traditional CT positioning method.
Objective To evaluate the effectiveness of Confidence high viscosity bone cement system and postural reduction in treating acute severe osteoporotic vertebral compression fracture (OVCF). Methods Between June 2004 and June2009, 34 patients with acute severe OVCF were treated with Confidence high viscosity bone cement system and postural reduction. There were 14 males and 20 females with an average age of 72.6 years (range, 62-88 years). All patients had single thoracolumbar fracture, including 4 cases of T11, 10 of T12, 15 of L1, 4 of L2, and 1 of L3. The bone density measurement showed that T value was less than —2.5. The time from injury to admission was 2-72 hours. All cases were treated with postural reduction preoperatively. The time of reduction in over-extending position was 7-14 days. All patients were injected unilaterally. The injected volume of high viscosity bone cement was 2-6 mL (mean, 3.2 mL). Results Cement leakage was found in 3 cases (8.8%) during operation, including leakage into intervertebral space in 2 cases and into adjacent paravertebral soft tissue in 1 case. No cl inical symptom was observed and no treatment was pearformed. No pulmonary embolism, infection, nerve injury, or other complications occurred in all patients. All patients were followed up 12-38 months (mean, 18.5 months). Postoperatively, complete pain rel ief was achievedin 31 cases and partial pain refief in 3 cases; no re-fracture or loosening at the interface occurred. At 3 days after operation and last follow-up, the anterior and middle vertebral column height, Cobb angle, and visual analogue scale (VAS) score were improved significantly when compared with those before operation (P lt; 0.05);and there was no significant difference between 3 days and last follow-up (P gt; 0.05). Conclusion Confidence high viscosity bone cement system and postural reduction can be employed safely in treating acute severe OVCF, which has many merits of high viscosity, long time for injection, and easy-to-control directionally.
ObjectiveTo investigate the short-term effectiveness of minimally invasive percutaneous plate osteosynthesis (MIPPO) in treatment of anterior pelvic ring fractures. MethodsBetween January 2012 and October 2013, 16 patients with anterior pelvic ring fractures were treated with MIPPO. There were 10 males and 6 females at the age of 20-63 years (mean, 41 years). The causes of injury were traffic accident in 9 cases and falling from height in 7 cases. The duration of injury to admission was 2 hours to 5 days (mean, 1 day). According to Tile classification, 8 cases were rated as type B2, 4 cases as type B3, 2 cases as type C1, and 2 cases as type C2. Of them, 2 cases had iliac wing fracture, and 4 cases had pelvic posterior ring fracture. The time from admission to operation was 3-12 days (mean, 6 days). ResultsThe bleeding volume was 60-120 mL (mean, 70 mL). All wounds healed by first intention. No postoperative complication of deep venous thrombosis or long-term continuous pain occurred. All cases were followed up 5-27 months (mean, 11.5 months). No clinical manifestation of lateral femoral cutaneous nerve injury or spermatic cord injury was found, and cremasteric reflex existed in males. All cases obtained bony union, and the healing time was 12-16 weeks (mean, 13 weeks). During the follow-up period, no loss of fracture reduction and no internal fixation loosening or broken were observed. According to Matta radiological evaluation criterion, 16 cases had anatomical reduction, and 3 cases had satisfactory reduction; according to Majeed scoring system of pelvic fracture, the results were excellent in 12 cases and good in 4 cases. ConclusionMIPPO for treatment of anterior pelvic ring fractures has the advantages of less intraoperative blood loss, few soft tissue complications, and low infection rate, and can get satisfactory short-term effectiveness.