ObjectiveTo evaluate the effect of reconstruction of forearm interosseous membrane (IOM) using extensor carpi radialis longus combined with radial head replacement for restoring the forearm longitudinal stability. MethodsTen fresh-frozen adult cadaveric forearms were selected, including 8 males and 2 females with a mean age of 38.2 years (range, 29-74 years). Each forearm was treated as following steps: radial head excision (group A), radial head excision+the distal ulnar radial joints separation (group B), radial head excision+the distal ulnar radial joints separation+IOM central band excision (group C), reconstructed IOM with extensor carpi radialis longus tendon (group D), radial head prothesis replacement (group E), and reconstructed IOM with extensor carpi radialis longus tendon+radial head prothesis replacement (group F). The distance between ulna and radius and radioulnar joint displacement were observed under load and non load. The force loading on both ends of specimen was recorded when the radius shifted 5 mm proximally. ResultsRestoring the radial length could maintain normal distance between radius and ulna. The interosseous membrance reconstruction could restore the load transmission between radius and ulna. The force loading specimen was (74.507±4.967), (49.227±1.940), (17.827±1.496), (24.561±1.390), (140.247±8.029), and (158.423±9.142)N in groups A, B, C, D, E, and F respectively when the radius shifted 5 mm proximally, showing significant difference among groups (P < 0.01). ConclusionReconstruction of the IOM with the extensor carpi radialis longus tendon is insufficient to restore the forearm longitudinal stability. Reconstruction using extensor carpi radialis longus tendon combined with radial head replacement may be a new choice for treatment of forearm longitudinal instability.
Transcatheter aortic valve replacement is an effective treatment for aortic stenosis currently, especially in elderly, surgical high-risk, and surgical procedures-intolerant patients with severe aortic stenosis. After several generations of updates in design and function, the self-expandable valves have shown significant efficacy in treating aortic stenosis patients with bicuspid aortic valve, bioprosthetic valve failure or small annulus, and superiority in terms of valve durability, and the favorable hemodynamic outcomes could translate into clinical endpoint benefit. This literature review summarizes the advantages and recent advances of the self-expandable valves in transcatheter aortic valve replacement.
Abstract The fracture of the prosthetic stem after prosthetic replacement of femoral head is not rare. In this study, the photoeastic instrument was used to study the stress distribution on the prosthetic stem following its insertion and to analyse the factors influencing the fracture of the stem. Through the examination of 9 places in 8 cases, it was found that:(1) The removal of femoral calcar and the inframedullary filling of the bone cement directly influenced the stress distribution. (2) The valgus or varus condition of the prosthesis would lead to stress concentration on the stem. (3) Once lossening of the prosthesis occured it would change the preliminary installingstress distribution in the upper femur which would lead to fatigue fracture. Ths experimental data and clinical observation would provide scientific basis forthe prevention of fracture of prosthetic stem following prosthetic replacement of femoral head.
Objective To explore the effect of minimally invasive and mini-incision surgery (MIS) in total hip arthroplasty (THA) on late osteonecrosis of femoral head (ONFH). Methods From March 2003, Eighteen patients (22 hips) with ONFH underwent MIS in THA. Their ages ranged from 24to 57 years, including 13 males and 5 females. The mean body mass index ranged from 17.1 to 30.1(24.6 on average). The Harris hip score was 46 points before operation. Modified posterior-lateral approach was adopted, and the MIS THA was performed by cementless prosthesis. As a comparison, 18 patients (22 hips) were performed by conventional THA at the same period. The data, including bleeding volume during operation, incision length, operative time, and postoperative function recovery, were compared. Results Follow-ups were done for 6 to 20 months (11 months on average). Dislocation occurred in one patient that underwent conventional THA 2 days after operation. No complication occurred in MIS THA group. The incision lengths ranged from 8.7 to 10.5 cm (9.3 cm on average) in MIS THA group, being statistically different (Plt;0.01). There was no significant difference in Harris scoring of the function between the two groups both before the operation and after the operation (Pgt;0.05). The operative time was almost the same, but the bleeding volume in MIS THA group was less (Plt;0.05). The function recovery was faster in MIS THA group.Conclusion The MIS THA is an alternative to the treatment of late ONFH. The advantages of MIS THA are fewer trauma, less bleeding volume, and faster recovery. The MIS THA should be performed by surgeons with rich experiences in THA and hospitals with necessary instruments.
Objective To investigate the relationship between the initial stabil ity and infected loosening of the total hip arthroplasty (THA) prosthesis. Methods From January 2000 to December 2008, 110 cases (110 hips) were treated with THA revision. Among them, 15 cases (15 hips) were confirmed infected loosening. There were 8 males and 7 females with anaverage age of 62 years (range 42-75 years). The infected signs were found from 6 months to 2 years after initial THA. All of them had Tsukayama type IV and late infection, including 6 cases of acetabular infected loosening (5 cases of one-stage and 1 case of two-stage acetabular revision), 7 cases of simple infected loosening of femoral prosthesis (4 cases of one-stage and 3 cases of twostage femoral prosthesis revision), and 2 cases of joint capsule infection and sinus without prosthesis loosening (debridement and continuous irrigation). Results All incisions healed by first intention. Fifteen patients were followed up for 12 to 36 months (average 24 months). In 13 cases of revision, postoperative X-ray films showed that femoral acetabular prostheses were in good position, and had no cl inical and imaging infective signs of loosening. In 2 cases of joint capsule infection, sinus recurred 6 months postoperation without hip joint pain, the function of weight-bearing and walking of hip joint was normal. Harris score increased from preoperative average of 42 to postoperative average of 85; the results were excellent in 4 cases, good in 7 cases, and fair in 4 cases. Conclusion The infection of THA may occur in the whole joint, half-joint or just in joint capsule. The initial stabil ity of the prosthesis would affect the long-term survival of the prothesis. If the prosthesis initial stabil ity is obtained, even if there are infective factors, infections would also be l imited.
Objective To explore the affecting factors on sinus rhythm maintenance after electric cardioversion for patients with atrial fibrillation (Af) after cardiac valve replacement. Methods One hundred fifty two valvular disease patients with Af after cardiac valve replacement were randomized to 2 groups: Amiodarone group and control group (without anti arrhythmic drugs) after cardioversion. Af recurrence was observed during one year follow up. Results (1) No significant difference of Af recurrence betwe...