Objective To determine the efficacy of forced expiratory volume in six seconds( FEV6 ) as an alternative for forced vital capacity( FVC) in the diagnosis for mild-moderate chronic obstructive pulmonary disease( COPD) .Methods A total of 402 mild-moderate COPD and 217 non-COPD patients’ spirometric examinations were retrospectively analyzed. The correlation between FEV6 and FVC, FEV1 /FVC and FEV1 /FEV6 was evaluated by the Spearman test. Considering FEV1 /FVC lt;70% as being the ‘golden standard’ for airway obstruction, a ROC curve was used to determine the best cut-off point for the FEV1 /FEV6 ratio in the diagnosis for COPD. Results The Spearman correlation test revealed the FEV1 and FEV6 , FEV1 /FEV6 and FEV1 /FVC ratios were highly correlated ( r = 0. 992, 0. 980, respectively, P = 0. 000) . Using FEV1 /FEV6 lt; 70% as the diagnosis standard, 12. 69% of the 402 patients could not be diagnosed as COPD. The FEV1 /FVC ratio of these patients was very close to 70% . The best cut-off point for the FEV1 /FEV6 ratio in the diagnosis of mild-moderate COPD was 72% while the sensitivity and specificity were 94. 7% and 92. 2% , respectively. Conclusions There is a b correlation between FEV1 /FVC and FEV1 /FEV6 . The FEV6 can be a valid alternative for FVC in the diagnosis for mild-moderate COPD, although it may result in false negative. The best cut-off point for the FEV1 /FEV6 ratio is 72% .
Objective To evaluate the effect of cardiopulmonary bypass (CPB) on pulmonary function in infants with variable pulmonary arterial pressure resulting from congenital ventricular septal defect (VSD). Methods Twenty infants with VSD underwent corrective surgery were divided into pulmonary hypertension group (n= 10) and non-pulmonary hypertension group (n= 10) according to with pulmonary hypertension or not. Pulmonary function was measured before CPB , 3h,6h,9h,12h,15h,18h,21h, and 24h after CPB and duration for mechanical ventilation and cardiac intensive care unit stay were recorded. Results Pulmonary function parameters before CPB in nonpulmonary hypertension group were superior to those in pulmonary hypertension group (P〈0.01), and pulmonary function parameters after CPB deteriorated than those before CPB (P〈0.05), especially 9h,12h and 15h after CPB (P〈0.01). Compared to pulmonary function parameters before CPB, pulmonary function parameters of pulmonary hypertension group at 3h after CPB were improved (P〉0.05), but they deteriorated at 9h,12h and 15h after CPB (P〈0. 05). Pulmonary function parameters at 21h and 24h after CPB was recoverd to those before CPB in two groups. Conclusions Although exposure to CPB affects pulmonary function after VSD repair in infants, the benefits of the surgical correction to patients with pulmonary hypertension outweigh the negative effects of CPB on pulmonary function. Improvement of cardiac function can avoid the nadir of pulmonary function decreasing. The infants with pulmonary hypertension will be weaned off from mechanical ventilator as soon as possible, if hemodynamics is stable, without the responsive pulmonary hypertension or pulmonary hypertension crisis after operation.
ObjectiveTo know about equipment of pulmonary function tests (PFTs) in community health service centers and the knowledge of pulmonary function in general physicians.MethodsThis questionnaire survey was carried out sponsored by Shanghai Basic Alliance for Respiratory Diseases Prevention and Treatment from June to December in 2016. Most community health service centers in 16 districts of Shanghai participated the survey. The questionnaire included education background, professional qualification, PFTs equipment, and knowledge about PFTs.ResultsThere were 963 general physicians in 131 community health service centers completed the questionnaire. There were 27 (20.6%) community health service centers equipped with simplified pulmonary function test device and 910 (94.5%) physicians knowing PFTs. Out of these 910 physicians, 458 physicians (50.3%) gave the correct answer on question about the items of PFTs. The accuracy of question about the diagnosis of chronic obstructive pulmonary disease (COPD) was 24.0% (218/910).ConclusionsThe rate of community health service centers with equipment on PFTs is low and the knowledge on pulmonary function in general physicians is insufficentt in Shanghai. Training on pulmonary function is essential to adapt the stratified treatment of COPD.
Objective To explore the profile and diagnosis value of airway resistances before and after bronchial dilation test ( BDT) in patients with COPD and asthma. Methods Airway resistances before and after BDT were measured in COPD patients and asthma patients with different severity by impulse oscillometry ( IOS) , and the characteristic changes of the two different diseases were analyzed compared with healthy subjects. Results Airway resistance indexes except X5 were higher in the COPD and the asthma patients than those in the healthy subjects before BDT ( P lt; 0. 05) . There were significant differences in airway resistance indexes except X5 and Rc between the mild asthma patients and the moderate to severe asthma patients. Significant difference in Z5, Fres, and Rp were observed in the mild COPD patientscompared with the moderate to severe COPD patients. There were statistical differences in airway resistance indexes except X5 between the two groups before and after BDT both in the COPD and the asthma patients ( P lt;0. 05) . The rates of change in Z5, Fres, R5, and Rp were higher than those of FEV1% pred, especially higher in the asthma patients than in the COPD patients ( P lt; 0. 05) . Significant negative correlations between FEV1% pred and Z5, Fres, R5, Rp were revealed in the COPD and the asthma patients ( P lt;0. 01) .The correlation between Fres and FEV1% pred was most significant in the COPD and the asthma patients ( r = - 0. 561, - 0. 761) . Conclusion Airway resistances measured by IOS is sensitive indicators in detecting the airflow obstruction in COPD and asthma, and is useful in early and differential diagnosis of COPD and asthma.
目的:探讨慢性阻塞性肺疾病(COPD)合并糖尿病患者的肺功能及血气分析特点并分析其临床意义。方法:选取2008年1月~2009年1月在我院门诊就诊的稳定期患者53例作为研究对象,并根据是否合并糖尿病分为COPD合并糖尿病组26例,单纯COPD组27例,并通过肺功能检测及血气分析,检测肺活量 (VC)、用力肺活量 (FVC)、第1秒钟用力呼气容积 (FEV1)、 FEV1/用力肺活量 (FVC)、用力呼气中期流速PEF(25%~75%) 、肺一氧化碳弥散(DLCO)及肺一氧化碳弥散量实测值占预计值的百分比(DLCO /PRED)等肺功能指标及PaO2、PaCO2等血气指标,并进行组间分析。结果:COPD合并糖尿病组肺通气功能指标VC、FVC、FEV1、PEF(25%~75%)和弥散功能指标DLCO、DLCO/PRED及PaO2显著低于单纯 COPD组。结论:COPD合并糖尿病时肺通气功能和弥散功能都可受损。
Objective To estimate the degree of the angle between left principal bronchus and trachea, and it is correlative with the pulmonary function in the patients with rheumatic mitral valve disease. Methods According to various degree of angles between left principal bronchus and trachea,53 patients were divided into three groups, group 1: angle between left principal bronchus and trachea less than 50 degree, group 2: between 50 and 64 degree, group 3: between 65 and 79 degree. The pulmonary function tests,ultrasonic cardiography and left principal bronchus X-ray tomographic film were carried out in three groups before operation. Compare pulmonary function data with different angle between left principal bronchus and trachea in three groups. Results Exception of vital capacity ,residual volume and total lung capacity,the rest markers of lung function showed significant differences (Plt;0.05) in three groups. The correlation of the angle between left principal bronchus and trachea and the ratio of residual volume and total lung capacity among three groups were positively correlative, and the other parameters of lung function were negatively correlative (Plt;0.01). Conclusion The degree of the angle between left principal bronchus and trachea is positively correlative with the extent of pulmonary function impairing.
0bjective To evaluate the efficacy of FEV6 and FEV1/FEV6 as surrogates for FVC and FEV1/FVC in the spirometric diagnosis of airway obstruction,and to determine the fixed cut-off point of FEV1/FEV6 which can be used as an alternative for FEV1/FVC lt; 70%.Methods Spirometry measurements were perform ed in 128 participants.FEV1,FEV6,FVC,FEV1%pred,FVC%pred,FEV1/FVC and FEV1/FEV6 were measured and analyzed.FEV1/FVClt;70% was used as the“gold standard”。Severity of obstruction was based on FEV % pred.From ROC curve analysis,the FEV1/FEV6 ratio,which corresponded to optimal combination of sensitivity and specificity,was determined.Correlation between FEV1/FVC and FEV1/FEV6 was studied.Results Of 128 participants,there were 65(51%)with FEV1/FVC ≥70% .Of the 63 participants with FEV1/FVC lt;70% ,there were 5 with FEV1/FEV6 between 70.09% to 71%。There was no significant difference between the mean value of FVC and that of FEV .Lifear correlation was revealed between FEV1/FVC and FEV1/FEV6 with the value close to 1(r=0.9979,Plt;0.0001).From ROC curve analysis,the FEV1/FEV6lt;71.14% was the best cut-off point coresponding to FEV1/FVC lt;70% .Conclusion These results suggest that FEV1/FEV6 is a valid alternative to FEV1/FVC for spirometric diagnosis of airw ay obstruction.There is a b corelation between FEV1/FEV6 and FEV1/FVC.