Objective To explore the application effect of virtual reality (VR) technology in low vision teaching for optometry students. Methods Undergraduate students majoring in optometry at West China School of Medicine of Sichuan University were selected as the research subjects. The students enrolled in 2020 adopted the traditional lecture-based learning (LBL) teaching mode (LBL teaching group), while the students enrolled in 2021 adopted the VR teaching mode (VR teaching group). Both groups of students studied the content of the same chapter on low vision, completed in-class tests after learning, and completed a questionnaire survey. Results There were 28 students in the VR teaching group and 30 students in the LBL teaching group. There was no statistically significant difference in age or gender composition between the two groups of students (P>0.05). The in-class test scores of students in the VR teaching group were higher than those in the LBL teaching group (86.43±6.10 vs. 78.10±7.69, P<0.05). Except for “subjective discomfort with this teaching mode”, the differences in other evaluation results between the two groups were statistically significant (P<0.05). VR teaching group students generally believed that applying VR technology to low vision teaching helped understand the visual experience and daily life status of low vision patients, improved learning efficiency and hands-on ability, reduced learning burden, and hoped to use this teaching mode routinely in other subject teaching. All students in the VR teaching group believed that this teaching mode was interesting, highly innovative, and enhanced teacher-student interaction.Conclusions Applying VR technology to low vision teaching can enable students to personally experience the impact of various diseases on patients’ visual function and daily life. This teaching method not only optimizes and improves teaching effectiveness, but also has a high acceptance rate among students, which is worth further promoting in future optometry teaching.
Objective To investigate the clinical characte ristic of vernier acuity in age-related macular degeneration (AMD) patients. Methods The vernier acuity test soft wear system was developed to detect the 23 cases (39 eyes) of AMD patients. Tweenty-one eyes were atrophic type and 17 eyes were exudative type. Two fixed targets and a movable target are shown on the computer screen. The examinee was asked to adjust the position of the central target and the relationship between it and align them by using a track ball. The computer automatically recorded the deviations of distances between the movable target and the specific one, and then computed and analysed the results of average threshold and variance.Results Both the atrophic and exudative AMD had higher vernier acuity threshold and its variance than normal subjects, and the differences were significant (P<0.01). The correlation coefficient between visual acuity and vernier acuity threshold was -0.78, and that between visual acuity and threshold variance was -0.80. The results suggest that vernier acuity thre shold and its variance were reliable parameters that reflect the visual acuity in AMD patients.Conclusions The results suggest that vernier acuity threshold and its variance were reliable parameters that reflect the visual acuity in AMD patients.(Chin J Ocul Fundus Dis,2003,19:201-268)
ObjectiveTo observe and evaluate the predictive value of serum cystatin C (Cys-C) on the risk of sight-threatening diabetic retinopathy (STDR). MethodsA non-randomized controlled cross-sectional clinical study. Ninety-two patients with type 2 diabetes mellitus (T2DM) who were admitted to Department of Ophthalmology of Beijing Tsinghua Changgung Hospital from January 2022 to October 2022 were included in the study. Among them, 50 were male, 42 cases were female, with the mean age of (58.24±12.49) years. The mean duration of T2DM was (13.18±8.35) years, of which 38 cases had a duration of ≥10 years. Twenty-nine cases complicated with hypertension, of which 16 cases had a duration of ≥10 years. Seventeen cases complicated with chronic kidney disease stage 2 and 23 cases were treated with lipid-lowering drugs. Hemoglobin Alc, serum Cys-C, serum lipids and renal function were tested, and urinary microalbumin/creatinine ratio (ACR) was calculated. According to the 2003 American Academy of Ophthalmology "Clinical Guidelines for Diabetic Retinopathy (DR)" and international clinical DR severity grading standards, the patients were divided into STDR and non-STDR groups, with 44 and 48 cases in each group, respectively. STDR was defined as severe non-proliferative DR, proliferative DR, and macular edema. Logistic regression was used to analyze the independent risk factors of STDR in T2DM patients. Receiver operating characteristic curve (ROC curve) was used to calculate and analyze the area under ROC curve (AUC) and the predictive value of serum Cys-C and ACR in predicting STDR in T2DM patients. ResultsSerum Cys-C levels in STDR and non-STDR groups were 1.10 (0.94, 1.28) and 0.91 (0.83, 1.02) mg/L, respectively, with ACR of 4.29 (1.05, 21.89) and 1.39 (0.77, 3.80) mg/mmol, respectively. Compared with non-STDR group, serum Cys-C and ACR in STDR group were higher, and the difference was statistically significant (Z=-3.984, -3.280; P<0.05). Multivariate logistic regression analysis showed that serum Cys-C was an independent risk factor for STDR (odds ratio=1.337, 95% confidence interval 1.145-2.090, P=0.033), and the risk of STDR increased by 33.7% for every 0.1 mg/L increase in serum Cys-C. ROC analysis results showed that serum Cys-C>1.065 mg/L combined with ACR>5.84 mg/mmol predicted the AUC of STDR in T2DM patients was 0.661, with the specificity of 95.8%. ConclusionsThe high serum Cys-C level is an independent risk factor for STDR in T2DM patients. Serum Cys-C has high predictive value for the occurrence of STDR.
ObjectiveTo observe and analyze the rate of visual acuity progression and binocular symmetry in patients with choroideremia (CHM). MethodsA single-center retrospective longitudinal cohort study. From April 2009 to August 2022, 38 eyes of 19 patients diagnosed with CHM through clinical and genetic testing at the Department of Ophthalmology, Peking Union Medical College Hospital, were included in this study. All patients underwent at least 2 follow-up visits with a minimum interval of 1 year between visits, and binocular best-corrected visual acuity (BCVA) results were recorded at each follow-up visit. Decimal visual acuity was converted into logarithm of the minimum angle of resolution (logMAR) for analysis. The patient group consisted of 19 males from 16 unrelated families. The age at initial visit was (39.52±13.24) years, with a (2.63±1.61) follow-up visits over a duration of (4.95±2.68) years. A total of 50 binocular BCVA data were included. Annual progression rate of visual acuity was calculated based on longitudinal and cross-sectional data. Spearman correlation coefficient and Bland-Altman method were used to evaluate the binocular symmetry. ResultsThe rate of visual acuity progression was (0.095±0.148) logMAR units/year based on longitudinal data and (0.018±0.009) logMAR units/year based on cross-sectional data. The binocular symmetry for BCVA of the baseline values was strong; however, the binocular symmetry of progression rates for BCVA was moderate. Spearman correlation analysis showed that binocular symmetry in baseline BCVA was high (r=0.881, P<0.001). The symmetry of binocular vision progression rates based on longitudinal data was moderately symmetric (r=0.528, P=0.020). Bland-Altman analysis showed that 94.7% of binocular baseline BCVA differences were within 95% confidence interval (CI) of 95% limit difference (LOA), indicating good symmetry of binocular baseline BCVA. The number of binocular BCVA progression rate differences within 95%CI of 95%LOA was 89.5%, suggesting moderate symmetry in binocular BCVA progression rate. The results of Spearman correlation coefficient and Bland-Altman analysis of binocular symmetry were basically consistent. ConclusionsThe rate of visual acuity progression of patients with CHM based on longitudinal and cross-sectional data is (0.095±0.148) and (0.018±0.009) logMAR units/year, respectively. Cross-sectional data from patients of different ages should not be used to infer the progression rate of the natural history. Binocular eyes with highly symmetrical baseline visual acuity may differ in the rate of visual acuity progression.
ObjectiveTo compare the clinical characteristics and analyze the factors affecting vision prognosis of idiopathic macular hole (IMH) or myopic macular hole (MMH). MethodsA cross-sectional study. From October 2012 to October 2020, 336 patients with 346 eyes of IMH and MMH who were diagnosed in Shanxi Provincial Eye Hospital with continuous follow-up data after surgery were included. There were 346 eyes (336 cases), including IMH with 247 cases (255 eyes) and MMH with 89 cases (91 eyes), which were divided into IMH group and MMH group. Best corrected visual acuity (BCVA) and optical coherence tomography were performed in all eyes. The BCVA examination used the standard logarithmic visual acuity chart, which was converted into logarithmic minimum angle of resolution (logMAR) visual acuity. The age of outset in IMH and MMH was 64.8±6.6 and 59.2±8.1 years, the logMAR BCVA was 1.11±0.50 and 1.80±0.78, respectively. There were significant differences in age (Wald=34.507) and logMAR BCVA (Z=-7.703) between two groups (P<0.05). All eyes were performed inner limiting membrane (ILM) peeling or partial inverted ILM covering hole operation. After the operation, the vitreous cavity was filled with air, C3F8 and silicone oil, including 73, 102, 83 eyes in IMH group and 9, 10, 72 eyes in MMH group, respectively. Follow-up time after surgery was more than 2 months. The optimal BCVA and macular hole closure of the two groups were observed. If the quantitative data conformed to the normal distribution, the generalized estimating equation was used, otherwise, the Mann-Whitney U test or Kruskal-wallis test was used, the χ2 test was used for the comparison of categorical variables. Generalized estimating equation logistic regression analyzed the influencing factors of optimal BCVA after surgery and visual acuity success. ResultsIn IMH and MMH, the optimal logMAR BCVA were 0.71±0.36, 1.10±0.51 respectively, and 147 (57.6%, 147/255) eyes, 63 (69.2%, 63/91) eyes achieved visual success respectively. There was a significant difference in the optimal logMAR BCVA (Z=-6.803, P<0.005), but no difference in visual success rate (χ2=3.772) between the two groups. The visual success rate of IMH at the same baseline BCVA level was higher than that of MMH, and the difference was statistically significant (χ2=14.500, P=0.001). Logistic regression analysis showed that the influencing factors predicting poor optimal visual acuity after surgery were: IMH, baseline BCVA [odds ratio (OR)=2.941, 95% confidence interval (CI) 1.341-6.447, P<0.05], MH diameter (OR=1.003, 95%CI 1.001-1.005, P<0.05), silicon oil filling (OR=3.481, 95%CI 1.594-7.605, P<0.05); MMH, baseline BCVA (OR=2.549, 95%CI 1.344-4.834, P<0.05), C3F8 filling (OR=18.131, 95%CI 1.505-218.365, P<0.05) and silicon oil filling (OR=7.796, 95%CI 0.997-60.944, P<0.05). The factors leading to a lower likelihood of achieving visual success: IMH, baseline BCVA (OR=213.329, 95%CI 46.123-986.694, P<0.05), MH diameter (OR=0.995, 95%CI 0.992-0.997, P<0.05), silicon oil filling (OR=0.326, 95%CI 0.115-0.926, P<0.05) and duration (OR=1.036, 95%CI 1.005-1.067, P<0.05); MMH, baseline BCVA (OR=13.316, 95%CI 2.513-70.565, P<0.05) and duration (OR=1.022, 95%CI 1.001-1.044, P<0.05). ConclusionsMMH was earlier than IMH in age of outset. Baseline vision significantly affected vision prognosis in IMH and MMH. Silicone oil should be avoided as much as possible under the premise of hole closure.
ObjectiveTo observe the ocular manifestations and the titer of aquaporin 4 antibody (AQP-4) in NMO patients, and to evaluate the BCVA prognosis in patients with different titers of AQP-4Ab.MethodsA retrospective case study. From September 2009 to March 2014, 132 NMO patients diagnosed in Department of Neurology and Ophthalmology in Huashan Hospital of Fudan University were included in the study. Among the patients, 74 patients (56.06%) were involved in optic nerve for the first time, among which 63 patients (47.72%) were involved in optic nerve alone, and 11 patients (8.33%) were involved in optic nerve and spinal cord at the same time. The recurrence rate was 62.88% (twice or more). All patients underwent BCVA, slit lamp microscope, fundus examination, thyroid function, sex hormones, and serum AQP-4Ab detection. BCVA was recorded at admission and before discharge from hospital, and worse BCVA was recorded in binocular patients. The BCVA of patients with different titers of AQP-4Ab were analyzed comparatively.ResultsAmong the 74 patients with optic nerve involved in the first onset, 50 patients with BCVA<0.1 at the initial diagnosis (67.57%); AQP-4Ab positive was found in 56 patients, which including 13, 9 and 34 patients of AQP-4Ab titer 5 - 60, 61 - 100 and >100 RSRU/ml. After 2 weeks of treatment, BCVA improved in 40 patients (71.42%), including 11 (84.62%), 6 (66.67%) and 23 (67.64%) of AQP-4Ab titer 5 - 60, 61 - 100 and > 100 RSRU/ml. Among 132 patients, 98 patients (74.24%) were AQP-4Ab positive. There were 73 patients (55.30%) with abnormal immune rheumatoid index.ConclusionsThe optic nerve is involved in 56.06% patients with NMO for the first time, and 67.57% of the patients had poor vision with BCVA<0.1. BCVA prognosis is better in patients with serum AQP-4Ab titer of 5 - 60 RSRU/ml.