Objective To investigate the biocompatibility of diamond-like carbon(DLC) coated NickelTitanium shape memory alloy with osteoblasts cultured invitro. Methods Rabbit’s osteoblasts were incubated with DLCcoated NickelTitanium shape memory alloy disks and uncoated ones of equal size for 5 days. The control group(without shape memory alloy in culture media) was performed simultaneously. The cultured cells were counted and graphed. The samples from culture media were collected and the concentrations of alkaline phosphatase (ALP) and nickel(Ni2+) were measured from the 1st to 5th day respectively. Results The proliferation of osteoblasts and the concentration of ALP in both DLC-coated group and control gruop was higher than uncoated group. The proliferation of osteoblasts on the 3rd, 4th, and 5th day in both DLC-coatedgroup and control group was significantly higher than that in the uncoated group(P<0.05). The concentration of ALP in DLC-coated group on the 2nd, 3rd, and 5th day and in the control group on the 3rd, 4th, and 5th day was significantly higher than that in the uncoated group(P<0.05). The concentration of Ni2+ on the 3rd, 4th, and 5th day was significantly lower than that in the uncoated group(P<0.05). Conclusion DLC- coated NickelTitanium shape memory alloys appears to have better biocompatibility with osteoblast cultured in vitro compared to uncoated ones.
Objective To investigate the effectiveness of nickel-titanium shape memory staples in treating multiple metatarsal fractures. MethodsThe clinical data of 27 patients with multiple metatarsal fractures who were treated between January 2022 and June 2023 and met the selection criteria were retrospectively analysed. The cohort consisted of 16 males and 11 females, aged 33-65 years (mean, 47.44 years). The causes of injury included heavy object impact in 11 cases, traffic accidents in 9 cases, and crush in 7 cases. Simultaneous fractures of 2, 3, 4, and 5 bones occurred in 6, 6, 4, and 8 cases, respectively, with tarsometatarsal joint injury in 3 cases. Fixation was performed using staples for 16, 22, and 9 fractures in the metatarsal neck, shaft, and the base, respectively, and 5 tarsometatarsal joint injuries. Preoperative soft tissue injuries were identified in 8 cases and classified according to the Tscherne-Oestern closed soft tissue injury classification as type Ⅰ in 5 cases and type Ⅱ in 3 cases. One case of type Ⅱexhibited preoperative skin necrosis. The patients were treated with fixation using nickel-titanium shape memory staples. Complications and fracture healing were documented. At last follow-up, the American Orthopaedic Foot and Ankle Society (AOFAS) forefoot score was used to evaluate the function, and the visual analogue scale (VAS) score was used to evaluate the pain. Results The 27 patients were followed up 9-19 months (mean, 12.4 months). Postoperative X-ray films revealed no loss of fracture reduction, and all fractures achieved bony union. No internal fixator loosening, breakage, or other mechanical failures was observed. The mean fracture healing time was 3.13 months (range, 3-4 months). Postoperatively, 4 cases (2 of Tscherne-Oestern type Ⅰ, 2 of type Ⅱ) developed superficial skin necrosis, which resolved with dressing changes. No infection was observed in the remaining patients, and all wounds healed. At last follow-up, the AOFAS forefoot score ranged from 70 to 95, with an average of 86.6, of which 19 cases were excellent, 6 cases were good, and 2 cases were fair, with an excellent and good rate of 92.6%; the VAS score ranged from 0 to 3, with an average of 0.9, of which 24 cases were excellent, and 3 cases were good, with an excellent and good rate of 100%. Conclusion The use of nickel-titanium shape memory staples in the treatment of multiple metatarsal fractures can effectively protect local skin and soft tissues and minimize secondary damage associated with internal fixator insertion. It is a viable surgical option for management of multiple metatarsal fractures.
ObjectiveTo summarize the effectiveness of nitinol memory alloy two foot fixator with autologous cancellous bone grafting in treating old scaphoid fracture and nonunion.MethodsBetween January 2013 and January 2017, 11 patients of old scaphoid fracture and nonunion were treated with nitinol memory alloy two foot fixator and autologous cancellous bone grafting. All patients were male with an average age of 26.1 years (range, 18-42 years). The fractures were caused by sport in 3 cases, falling in 7 cases, and a crashing object in 1 case. The interval between injury and operation was 6-18 months (mean, 8.9 months). Postoperative outcome measures included operation time, fracture healing time, grip strength, range of motion (ROM) of flexion, extension, ulnar deviation, and radial deviation, Mayo score, visual analogue scale (VAS) score, and the Disabilities of the Arm, Shoulder, and Hand (DASH) score.ResultsThe operation time was 35-63 minutes (mean, 48 minutes). All incisions had primary healing with no infection and loosening or breakage of internal fixator. All patients were followed up 12-30 months (mean, 20.7 months). X-ray films showed that fracture healing was achieved in all patients with an average time of 15 weeks (range, 12-25 weeks). All internal fixators were removed after 10-12 months of operation (mean, 11.2 months). At last follow-up, the grip strength, ROMs of flexion, ulnar deviation, and radial deviation were superior to those before operation (P<0.05), no significant difference was found in ROM of extension between pre- and post-operation (t=0.229, P=0.824). There were significant differences in above indexes between affected and normal sides (P<0.05). At last follow-up, the Mayo, VAS, DASH scores were also significantly superior to those before operation (P<0.05).ConclusionFor the old scaphoid fracture and nonunion, Ni-Ti arched shape-memory alloy fixator and autologous cancellous bone grafting can obtain good effectiveness, which is an effective treatment.
Objective To evaluate the histocompatibil ity of porous hydroxyapatite (HAP) coating NiTi shape memory alloy and to provide a theoretical basis for its cl inical appl ication in bone defect repair. Methods Twenty-four Chinchilla rabbits weighing 2.0-2.5 kg were randomized into experimental group and control group (n=12). HAP coating NiTi shape memory alloy was implanted into the distal part of left femur of 12 rabbits in the experimental group, while holes without alloy implantation were performed on the control group. At 7, 14, 28 and 56 days after implantation, the animals werekilled (3 rabbits in each group at a time). Gross observation, histology observation, BMP-2 immunohistochemistry observation and image grey scale analysis were performed. And the histology observation was evaluated by GB/T16886.6-1997 in terms of inflammation, capsule wall of fibrous tissue, materials degradation and the response of peripheral tissue. Results All of the animals survived until being killed. The implants reached a peak embedded in bone tissue wholly, without loosening and bone absorption. The inflammatory cell infiltration and fibrous hyperplasia were at 7 days after implantation, with the formation of cyst wall of fibrous tissue and the implant wrapped by the cyst wall. The response of connective tissue proliferation was still obvious in partial samples of experimental group at 56 days after implantation, which was wrose than the control group but consistent with the in vivo implantation standard of GB/T16886.6-1997. Immunohistochemistry observation displayed the endogenous BMP-2 were in the cytoplasm of MSCs and osteoblast. The result of image analysis showed the expression of BMP-2 were staged in line with the repair of bone defect, two groups witnessed the peak expression of the BMP-2 at 14 days after implantation. There wereno significant differences among different time points in the staining gray scale of BMP-2 (P gt; 0.05). Conclusion HAP coating NiTi shape memory alloy, as a biomedical material, has excellent histocompatibility with bone.
【摘要】目的探索内镜直视下应用带膜记忆合金支架对晚期食管、贲门恶性狭窄的介入治疗方法。方法2005年1月2009年11月对49例失去手术机会或拒绝手术的晚期食管癌或贲门癌致食管或贲门狭窄患者,行电子胃镜引导下放置镍钛合金支架;对狭窄程度重、胃镜不能通过者,先行Savary探条扩张再放置支架。结果49例均成功置入支架,解除狭窄有效率达100%。结论内镜直视下带膜支架置入操作方法简便、安全,可改善患者的生存质量,延长生存时间。
ObjectiveTo evaluate the effectiveness of nitinol memory alloy two foot fixator combined with Kirschner wire in the treatment of trans-scaphoid perilunate dislocation.MethodsBetween September 2011 and October 2018, 17 patients with trans-scaphoid perilunate dislocation were treated with nitinol memory alloy two foot fixator and Kirschner wire. There were 12 males and 5 females, with an average age of 32.6 years (range, 23-52 years). The disease duration was 8 hours to 9 days, with an average of 6.5 days. The causes of injury included 6 cases of falling injury, 4 cases of traffic accident injury, 3 cases of stress injury of wrist caused by sports, 2 cases of violent injury of wrist caused by machine impact, 1 case of military training injury, and 1 case of other injury. One case was complicated with nerve injury. According to Herbert’s classification, all the fractures were type B4. At 1 week before operation, 3 months, 6 months after operation and last follow-up, the wrist function was evaluated according to the Krimmer scale score.ResultsAll the 17 patients were followed up 10.5-48 months, with an average of 18.6 months. There was no loosening or infection of the internal fixator, no necrosis of the scaphoid and lunate. The periosteal dislocations of the patients were well reduced and the scaphoid fractures all healed. The healing time was 4-18 months, with an average of 11.3 months. The Krimmer wrist scores were 37.5±4.4, 61.3±7.2, 83.3±9.3, 87.3±8.2 at 1 week before operation, 3 months, 6 months after operation and last follow-up, respectively. The Krimmer wrist score at each time point after operation was significantly improved when compared with that before operation (P<0.05), and at 6 months after operation and last follow-up than at 3 months after operation (P<0.05). There was no significant difference between at 6 months and last follow-up (P>0.05). At last follow-up, the Krimmer wrist function was excellent in 13 cases, good in 2 cases, fair in 1 case, poor in 1 case, and the excellent and good rate was 88.23%.ConclusionNitinol memory alloy two foot fixator combined with Kirschner wire in the treatment of trans-scaphoid periosteal dislocation has definite effectiveness, simple operation, and good recovery of wrist function after operation.
The locking mechanism between bracket and shape memory alloy (SMA) archwire in the newly developed domestic orthodontic device is the key to controlling the precise alignment of the teeth. To meet the demand of locking force in clinical treatment, the tightening torque angle of the locking bolt and the required torque magnitude need to be precisely designed. For this purpose, a design study of the locking mechanism is carried out to analyze the correspondence between the tightening torque angle and the locking force and to determine the effective torque value, which involves complex coupling of contact, material and geometric nonlinear characteristics. Firstly, a simulation analysis based on parametric orthogonal experimental design is carried out to determine the SMA hyperelastic material parameters for the experimental data of SMA archwire with three-point bending. Secondly, a two-stage fine finite-element simulation model for bolt tightening and archwire pulling is established, and the nonlinear analysis is converged through the optimization of key contact parameters. Finally, multiple sets of calibration experiments are carried out for three tightening torsion angles. The comparison results between the design analysis and the calibration experiments show that the deviation between the design analysis and the calibration mean value of the locking force in each case is within 10%, and the design analysis method is valid and reliable. The final tightening torque angle for clinical application is determined to be 10° and the rated torque is 2.8 N∙mm. The key data obtained can be used in the design of clinical protocols and subsequent mechanical optimization of novel orthodontic devices, and the research methodology can provide a valuable reference for force analysis of medical devices containing SMA materials.