west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "超声心动图" 100 results
  • Progress of Transesophageal Echocardiography in Paediatric Surgery

    With the development of surgical technology and the need of clinical, transesophageal echocardiography is more and more favored by clinicians. Although the transesophageal echocardiography has developed more than 20 years, yet it has not been widely used in operation at present in domestic. In addition, its application in surgery of children is more rare. It has been confirmed that intraoperative use of transesophageal echocardiography has good safety and wide range of application. We will summarize indications, complications, and the progress of the current technology from the scope of transesophageal echocardiography in pediatric surgery.

    Release date: Export PDF Favorites Scan
  • Echo-guiding percutaneous aortic stent implantation for coarctation of the aortic: A case report

    Currently, transcatheter intervention has emerged as a first-line treatment for coarctation of the aortic. Due to the radiation exposure associated with catheter interventional therapy, there are numerous restrictions, which harms both patients and medical personnel and is dependent on sizable radiation apparatus. Here, we report for the first time a case of echo-guiding percutaneous aortic stent implantation for a 27 years female patient of reproductive age. After discharge, the patient's aortic coarctation pressure decreased to 18 mm Hg, and the surgical results were satisfactory.

    Release date:2024-02-20 03:09 Export PDF Favorites Scan
  • Echocardiography Expression in Heart Valve Damage with Rheumatoid Arthritis

    【摘要】随着超声心动图的普及与发展,无症状性类风湿性关节炎心脏瓣膜改变的检出率逐渐增多。临床应重视类风湿性关节炎心脏瓣膜损害以及超声心动图在这类疾病中的诊断价值,以期改善患者预后。【Abstract】 Objective More and more cardiac valve changes are detected in asymptomatic patients with rheumatoid arthritis by echocardiography. It is essential to pay attention to the clinical features of heart valves damage and the diagnostic value of echocardiography on that in order to improve the prognosis of patients.

    Release date:2016-09-08 09:45 Export PDF Favorites Scan
  • Value of transthoracic echocardiography to monitor and evaluate aortic insufficiency after implantation of left ventricular assist device

    ObjectiveTo explore the value of transthoracic echocardiography (TTE) to monitor and evaluate aortic insufficiency (AI) within one year after the implantation of the left ventricular assist device (LVAD).MethodsWe retrospectively collected and analyzed the TTE data of 12 patients who received LVAD implantation from 2018 to 2020 in our hospital. All patients were males, with an average age of 43.3±8.6 years. We analyzed temporal changes in the aortic annulus (AA), aortic sinus (AoS), ascending aorta (AAo), the severity of AI and the opening of aortic valve before operation and 1 month, 3 months, 6 months and 12 months after LVAD implantation.ResultsAll 12 patients survived within 1 year after LVAD implantation. One patient was bridged to heart transplantation 6 months after implantation, and two patients did not receive TTE after 3 and 6 months. Compared to pre-implantation, AoS increased at 1 month after implantation (31.58±5.09 mm vs. 33.83±4.69 mm). The inner diameters of AA, AoS and AAo increased at 3, 6 and 12 months after LVAD implantation compared to pre-implantation (P<0.05), but all were within the normal range except for one patient whose AoS slightly increased before operation. After LVAD pump speed was adjusted, the opening of aortic valve improved. The severity of AI increased at 6 and 12 months after LVAD implantation compared to pre-implantation, and increased at 12 months compared to 6 months after LVAD implantation (P<0.05).ConclusionTTE can evaluate aortic regurgitation before and after LVAD implantation and monitor the optimization and adjustment of LVAD pump function, which has a positive impact on the prognosis after LVAD implantation.

    Release date:2021-07-02 05:22 Export PDF Favorites Scan
  • 超声检测右心室功能对肺切除术患者预后的评估

    目的 探讨用多普勒超声心动图检测术前静息和运动状态右心系统血流动力学变化及与患者术后恢复的关系。 方法 根据静息时右心射血分数 (RVEF)不同将 38例行肺切除术患者分为两组 ,A组 (n=17) :静息RVEFgt;0 .5 0 ,B组 (n=2 1) :RVEFlt;0 .5 0 ;又根据运动后 RVEF是否增加 ,将 38例患者分为两组 ,C组 (n=14 ) :RVEF增加 ,D组 (n=2 4 ) :RVEF降低。分别于术前和术后测定各组静息和运动状态的右心血流动力学等指标 ,观察这些指标的变化与患者术后恢复情况的关系。 结果 术后 D组与 C组比较 ,并发症发生例数增多 ,住院时间显著延长 ,心率增快 ,平均动脉压降低 ,RVEF较低 ,右心室收缩压较高 (Plt;0 .0 5 )。 结论 运动状态 RVEF值可作为肺切除手术患者术后恢复评估指标。

    Release date:2016-08-30 06:28 Export PDF Favorites Scan
  • Echocardiography in Evaluation of Right Ventricular Function

    Abstract: Right ventricular dysfunction or right heart failure is a complex clinical syndrome and often leads to a poor prognosis and high mortality. In order to detect right ventricular dysfunction at an early stage, provide a therapy guidance and evaluate treatment outcomes, right ventricular function evaluation has aroused more and more concern in clinical physicians. With the advantages of being non-invasive, accuracy and repetitiveness, echocardiography is used extensively in the assessment of heart function. In this review, we focus on how to use echocardiography to evaluate right ventricular function easily, efficiently, accurately and sensitively, and provide a good foundation for its further clinical application.

    Release date:2016-08-30 05:51 Export PDF Favorites Scan
  • Evaluation of the effectiveness of transcatheter closure of fenestrated atrial septal defect via femoral vein under ultrasound guidance

    Objective To introduce the application of transcatheter closure of multi-fenestrated atrial septal defect (ASD) via femoral vein under ultrasound guidance with amplatzer cribriform occluder (ACO) and atrial septal defect occluder (ASDO), as well as to assess its feasibility, effectiveness and safety. Methods The clinical data of 48 patients with fenestrated ASD occluded via femoral vein under ultrasound guidance from December 2015 to May 2018 in our hospital were retrospectively analyzed, including 17 males and 31 females, aged 10 months to 51 years, an average of 11.50±13.86 years, and weighting 6-79 (27.00±20.14) kg. Among 48 patients with fenestrated ASD, 12 patients had double-foramen and 13 atrial septal aneurysm combined with defects and 23 multi-foramen. All patients underwent transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE) to complete the closure of fenestrated ASD. Ultrasound, electrocardiogram and chest X-ray were reviewed the next day after surgery to evaluate the curative effect. Results Forty-eight patients with ASD were treated with 49 occluders, due to one patient with two occluders. There were 29 ASDO (8-26 mm) and 20 ACO (18-34 mm). During the operation, TTE/TEE examination showed that 48 patients were completely occluded, 13 patients showed fine bundle shunt in the unreleased push notification rod, and 9 patients had fine bundle shunt after the release of push notification rod. Fine bundle shunt was found in 8 patients 24 hours after operation, and microshunt was found in 3 patients 1 year after operation. All the patients were followed up. The occluder position was good. The right heart was reduced in different degrees, and the X-ray showed that the pulmonary blood was reduced in different degrees. No arrhythmia was found by electrocardiogram after operation. Conclusion It is a safe and effective method to use ACO and ASDO to occlude ASD through femoral approach under ultrasound guidance.

    Release date:2019-08-12 03:01 Export PDF Favorites Scan
  • 超声心动图诊断肺动脉栓塞

    目的 探讨超声心动图(UCG)诊断肺动脉栓塞(PE)的价值. 方法 采用UCG诊断PE,1例手术治疗,2例保守治疗. 结果 UCG发现1例右侧PE, CT示右侧肺动脉干癌栓或血栓形成; 1例动脉导管未闭合并感染性动脉内膜炎, 肺动脉赘生物形成,复查UCG肺动脉赘生物脱落;1例室间隔缺损修补术后片周漏合并感染性动脉内膜炎,肺动脉赘生物形成,手术证实为脓栓. 结论 UCG检查有助于正确诊断PE.

    Release date:2016-08-30 06:32 Export PDF Favorites Scan
  • 非体外循环冠状动脉旁路移植术后缺血性二尖瓣关闭不全患者的心功能改变

    目的 探讨非体外循环冠状动脉旁路移植术(offpump CABG)对缺血性二尖瓣关闭不全患者心功能改变的影响,以提高治疗效果。 方法 53例缺血性二尖瓣关闭不全患者,男45例,女8例;年龄 51~73 岁,平均年龄63.3岁。53例患者均行offpump CABG,术前及术后12个月分别采用超声心动图检测心功能改变及二尖瓣反流情况。 结果 术后3 h死于突发心室颤动1例;术后发生大出血1例,于术后6 h行二次开胸止血手术。随访52例,随访时间12个月,其中行超声心动图检查48例。术后12个月左心室收缩期末内径(34.75±6.83 mm vs. 38.80±7.21 mm,t=-3.550, P=0.001),左心室舒张期末内径(50.50±10.31 mm vs. 53.85±11.20 mm, t=-6.364, P=0000)和二尖瓣反流面积(25.32%±9.80% vs. 29.45%±12.30%,t=2.129, P=0.001)均较术前减小, 左心室射血分数(62.10% ±24.20% vs. 57.75%±22.10%, t=2.132, P=0.038)较术前增加。 结论 冠心病合并中度二尖瓣关闭不全患者行offpump CABG术后12个月二尖瓣反流量减少,左心室功能改善。

    Release date:2016-08-30 05:59 Export PDF Favorites Scan
  • Multivue reconstruction technique during mitral valve transcatheter edge-to-edge repair: A case report

    Echocardiography is an important imaging technique in transcatheter edge-to-edge mithal valve repair (TEER). During the operation, mitral leaflets capture and clamping have the highest requirements for ultrasound image quality and should be performed under the guidance of high-quality commissural view. However, standard commissural view cannot be obtained in some patients due to cardiac enlargement, transposition or limited esophageal acoustic window. In this condition, the optimal view can be obtained by Multivue technology. This paper reports a case of successful mitral valve TEER under the real-time guidance of Multivue technology, and summarizes the key points of this technology.

    Release date: Export PDF Favorites Scan
10 pages Previous 1 2 3 ... 10 Next

Format

Content