Objective To investigate the clinical results of allograft and sural neurovascular flap in repairing calcaneus and skin defects.Methods From February 1996 to December 2002, allograft and sural neurovascular flap were used to repair calcaneusand skin defects in 6 cases. The causes included road accident in 3 cases, strangulation in 2 cases and crashing object in 1 case. The defect locations were at theback of the calcaneus( 1/3, 1/2 and 2/3 of calcaneus in 3 cases, 2 cases and 1case respectively). The flap area ranged from 6 cm×7 cm to 12 cm×17 cm. Results The flaps survived completely in 4 cases; the distal flaps necrosed partly in 2 cases and the wound healed by dressing. The postoperative X-ray films showed that the repaired bone and joint had normal position and the arcus plantaris recovered. After a follow upof 6 months to 3 years all the patients were achieved bone union in allograft and had no complications of absorption, infection and repulsion. The weightbearing and walking functions were restored and the injured foot obtained a satisfactory contour. After 36 months of operation, the sensory recovery of foot occurred. Conclusion The used-allograft iseasy to be obtained and arcus plantaris is easy to recover. The reversesural neurovascular- flap in repairing calcaneus and skin defects has the following advantages: the maintenance of blood supply for injured foot, the less dangerous operation, the simple procedure, the recovery of walking function, and the good appearance and sensation.
ObjectiveTo compare the effectiveness of robot assisted internal fixation and traditional open reduction and internal fixation for calcaneal fractures.MethodsThe clinical data of 44 patients (44 feets) with calcaneal fracture admitted between October 2017 and December 2018 who met the selection criteria were retrospectively analyzed. According to different operation methods, they were divided into trial group (19 cases, treated with robot assisted percutaneous reduction and cannulated screw fixation through tarsal sinus incision) and control group (25 cases, treated with open reduction and internal fixation via traditional tarsal sinus incision). There was no significant difference in gender, age, injured side, cause of injury, fracture type, time from injury to operation, and preoperative Böhler angle, Gissane angle, calcaneus width, American Orthopedic Foot and Ankle Association (AOFAS) score, and other general data between the two groups (P>0.05). The operation time, intraoperative fluoroscopy frequency, and fracture healing time were recorded and compared between the two groups. Before operation and at 6 months after operation, the Böhler angle and Gissane angle were measured on the lateral X-ray film, and the calcaneal width was measured on the axial X-ray film of the calcaneus to evaluate the recovery of the deformity and collapse after surgical treatment; the AOFAS score was used to evaluate the function of the affected foot and ankle joint.ResultsThe operation time of the trial group was significantly longer than that of the control group (P<0.05), but the intraoperative fluoroscopy frequency was significantly less than that of the control group (P<0.05). In the control group, 1 case had skin necrosis, and 1 case had a little leakage from the incision; the rest of the two groups had no skin- and incision-related complications. Patients in both groups were followed up 6-12 months, with an average of 9.5 months. At 6 months after operation, the Böhler angle, Gissane angle, and calcaneal width in the two groups were significantly improved when compared with preoperative ones (P<0.05), and there was no significant difference between the two groups (P>0.05); the fractures in the two groups were healed, there was no significant difference in healing time (t=–1.890, P=0.066); the AOFAS scores of the two groups were significantly higher than those before operation (P<0.05), and the AOFAS score of the trial group was significantly higher than that of the control group (t=–3.135, P=0.003).ConclusionCompared with traditional C-arm fluoroscopic internal fixation for calcaneal fractures, robot-assisted internal fixation via tarsal sinus incision for calcaneal fractures significantly improves the function of the affected foot and maintains the accuracy of nail implantation after fracture reduction, reducing intraoperative fluoroscopy times, and the fracture heals well.
Objective To investigate the clinical significance of the distally-based sural musculocutaneous flap for the treatment of chronic calcaneal osteomyelitis. Methods From January 2002 to October 2005, 7 patients (4 males, 3 females; age range, 15-68 years ) were treated with the distallybased sural musculocutaneous flap, who had chronic calcanealosteomyelitis after calcaneal fracture. After the radical debridement for all the nonviable and poorly vascularized tissues, all the chronic calcaneal osteomyelitis patients, who had suffered from open calcaneal fracture or closed calcaneal fracture, were treated with the open reduction, the internal fixation, and thebone graft. The ulcer lasted for 3-12 months before diagnosis of osteomyelitis. The musculocutaneous flaps ranged in size from 8 cm×4 cm to 12 cm×7 cmand the muscle flaps ranged from 4 cm×3 cm to 6 cm×5 cm. The donor defects were closed primarily in 5 patients and were resurfaced with the splitthicknessskin graft in 2 patients. Results All the musculocutaneous flaps survived completely and all the wounds healed smoothly. All the patients followed up for 2-6 months had no recurrence of osteomyelitis or return to their preoperative ambulatory status.Conclusion It is feasible to use the distallybased sural musculocutaneous flap for treatment of chronic calcaneal osteomyelitis.
Objective To evaluate the clinical results of subtalar arthrodesis and calcaneal thalamus reconstruction for malunion of calcaneal fractures and to discuss the indications and its advantages of the management. Methods From December 1994 to January 2006, 84 cases(96 feet) of malunion of calcaneal fractures were treated with subtalar arthrodesis and calcaneal thalamus reconstruction. The L-shaped approach lateral to calcaneus was used. The bone autograft was harvested from iliac crest. Fiftyone cases were male and 33 cases were female, aging from 21 to 58 years (mean 385 years).One side was in volved in 72 cases and two sides in 12 cases. The injury was caused by falling from height in 57 cases, by traffic accident in 22 cases and other in 5 cases. It was 6-31 months from injury to operation (mean 9.5 months). Results Among the patients, all cases were followed up 1 to 132 months. The total excellent and good rate was 87.5%, including excellent in 31 feet, good in 53 feet and fair in 12 feet,according to Hindfoot scores system (American Orthopaedics Foot and Ankle Society). The B[AKo¨]hler’s and Gissane’s angles, the height of calcaneal thalamus and width of calcaneus were significant different from those of preoperation (Plt;0.01). Conclusion The treatment by bone autograft combined with subtalar arthrodesis and calcaneal thalamus reconstruction is an effective operation for malunion of calcaneal fractures, with advantages of correcting deformity, restoring the function of indfoot and relieving the pain of walking.
ObjectiveTo compare the biomechanical characteristics of self-made nickel-titanium shape memory alloy stepped plate with calcaneal plate and cannulated compression screws in fixing calcaneal osteotomy.MethodsCalcaneal osteotomy was operated on 6 fresh-frozen lower limbs collected from donors. Then three kinds of fixation materials were applied in random, including the self-made nickel-titanium shape memory alloy stepped plate (group A), calcaneal plate (group B), and cannulated compression screws (group C). Immediately after fixation, axial loading of 20-600 N and 20 N/s in speed was introduced to record the biomechanical data including maximum displacement, elastic displacement, and maximum load. Then fatigue test was performed (5 Hz in frequency and repeat 3 000 times) and the same axial loading was introduced to collect the biomechanical data. Finally, the axial compression stiffness before and after fatigue test were calculated.ResultsThere was no significant difference in the axial compression stiffness between pre- and post-fatigue test in each group (P>0.05). However, the axial compression stiffness was significant higher in group A than that in groups B and C both before and after fatigue test (P<0.05). No significant difference was found between group B and group C (P>0.05).ConclusionSelf-made nickel-titanium shape memory alloy stepped plate is better than calcaneal plate and cannulated compression screws in axial load stiffness after being used to fix calcaneal osteotomy.
Objective To evaluate the effectiveness of three-dimensional (3-D) printing assisting minimally invasive for intraarticular calcaneal fractures with percutaneous poking reduction and cannulate screw fixation. Methods A retrospective analysis was performed of the 19 patients (19 feet) with intraarticular calcaneal fracture who had been treated between March 2015 and May 2016. There were 13 males and 6 females with an average age of 38.2 years (range, 24-73 years). There were 3 open fractures and 16 closed fractures. By Sanders classification, 12 cases were type Ⅱ, 7 cases were type Ⅲ. By Essex-Lopresti classification, 13 cases were tongue type, 6 cases were joint-depression type. The time from injury to surgery was 1-10 days (mean, 4.7 days). A thin slice CT scan was taken of bilateral calcaneus in patients. By using the mirror imaging technique, the contralateral mirror image and the affected side calcaneus model were printed according to 1∶1 ratio. The displacement of fracture block was observed and contrasted, and the poking reduction was simulated. Calcaneal fracture was treated by percutaneous minimally invasive poking reduction and cannulate screw fixation. The Böhler angle and Gissane angle at immediate after operation and last follow-up was measured on X-ray films, and compared with preoperative measurement. The functional recovery was evaluated by American Orthopaedic Foot and Ankle Society (AOFAS) scores. Results The operation time was 25-70 minutes (mean, 45 minutes). The intraoperative blood loss was 10-40 mL (mean, 14.5 mL). All the incisions healed by first intention and had no relevant postoperative complications such as skin necrosis, nail tract infection, and osteomyelitis. All the patients were followed up 12-25 months (mean, 14.6 months). All patients obtained fracture healing, and the fracture healing time was 8-14 weeks (mean, 10.3 weeks). No screw withdrawal or breakage occurred during follow-up; only 1 patient with Sanders type Ⅱ fracture, whose calcaneus height was partially lost at 6 weeks after operation, the other patients had no reduction loss and fracture displacement, and no traumatic arthritis occurred. The Böhler angle and Gissane angle at immediate after operation and last follow-up were significantly improved when compared with preoperative ones (P<0.05), but there was no significant difference between at immediate after operation and last follow-up (P>0.05). The AOFAS score was 76-100 (mean, 88.2), and the results were excellent in 10 feet, good in 7, and fair in 2, the excellent and good rate was 89.5%. Conclusion 3-D printing assisting minimally invasive for intraarticular calcaneal fractures with percutaneous poking reduction and cannulate screw fixation can reduce the surgical trauma, improve the quality of reduction and fixation, and make the operation more safe, accurate, and individualized.
ObjectiveTo discuss the effectiveness of limited open reduction via sinus tarsi approach using medial distraction technique in the treatment of intra-articular calcaneus fractures by comparing with open reduction and internal fixation via extensile L-shaped incision. MethodsA retrospective analysis was made on the clinical data of 21 patients with intra-articular calcaneus fractures treated by sinus tarsi approach combined with medial distraction technique between April 2013 and November 2014 (minimally invasive group), and 32 patients treated by extensile L-shaped incision approach between June 2012 and September 2014 (extensile incision group). No significant difference was found in gender, age, injury pattern, fracture classification, time from injury to operation, preoperative Böhler angle, Gissane angle, calcaneal varus angle, the ankle and hind-foot score of American Orthopaedic Foot and Ankle Society (AOFAS), and visual analogue scale (VAS) score between 2 groups (P>0.05), which was comparable. The operation time, wound complications, and bone healing time were recorded. The postoperative function was also evaluated by AOFAS score and VAS score. The pre-and post-operative Böhler angle, Gissane angle, and calcaneal varus angle were measured on the X-ray films, and the corrective angle was calculated. ResultsSixteen patients were followed up 6-18 months (mean, 11.5 months) in the minimally invasive group, and 23 patients for 6-24 months (mean, 13.5 months) in the extensile incision group. Difference was not significant in operation time between 2 groups (t=0.929, P=0.796). No complication occurred in the minimally invasive group; partial skin flap necrosis occurred in 3 cases of the extensile incision group, was cured after dressing change. There was no loosening of implants or reduction loss in 2 groups at last follow-up. Subtalar joint stiffness occurred in 1 case of the minimally invasive group and 4 cases of the extensile incision group, and 1 patient had discomfort for the implants in the extensile incision group. The bone healing time was (9.9±0.8) weeks in the minimally invasive group, and was (10.1±0.7) weeks in the extensile incision group, showing no significant difference (t=0.613, P=0.845). Böhler angle, Gissane angle, calcaneal varus angle, AOFAS score, and VAS score were significantly improved at last follow-up when compared with preoperative values in 2 groups (P < 0.05), but there was no significant difference between 2 groups (P>0.05), and the corrective value of angle showed no significant difference between 2 groups (P>0.05). ConclusionLimited open reduction via sinus tarsi approach for intra-articular calcaneus fractures could reduce the incidence of wound complications effectively. Meanwhile, the medial distraction technique is helpful to correct the heel varus deformity.
Objective To review the application progress of minimally invasive technique in the treatment of calcaneus fractures and to analyze the advantages and disadvantages of each method as well as to predict the trend of development in the field. Methods Domestic and abroad literature concerning the minimally invasive technique applied in calcaneus fractures in recent years was reviewed extensively and analyzed thoroughly. Results There are both advantages and limitations of each minimally invasive technique including percutaneous reduction and fixation, limited incision, external fixator, arthroscopic assisted reduction, and balloon expansion reduction. But every technique is developing rapidly and becoming more and more effective. Conclusion A variety of minimally invasive technique can not only be used independently but also can be applied jointly to complement one another. It needs further study how to improve the effectiveness and expand the indications. And the theoretical basis of evidence-based medicine needs to be provided more.