west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "锁定钢板" 54 results
  • Research progress on intra-articular screw penetration in proximal humeral fracture treated with locking plate

    ObjectiveTo review the research progress on intra-articular screw penetration in proximal humeral fracture treated with locking plate. MethodsThe domestic and foreign literature about the proximal humeral fracture treated with locking plate was extensively reviewed. The incidence of screw penetration and risk factors were summarized from both primary and secondary screw penetrations, and the reasons of the intra-articular screw penetration and the technical solutions to avoid the penetration were analyzed. ResultsThe incidence of intra-articular screw penetration is about 11%-30%, which includes primary and secondary screw penetrations. The primary screw penetration is related to improper operation, inaccurate measurement, and “Steinmetz solid” effect, which results in inadequate fluoroscopy and blind zone. The secondary screw penetration is related to the loss of reduction and varus, collapse, and necrosis of the humeral head. The risk factors for intra-articular screw penetration include the bone mass density, the fracture type, the quality of fracture reduction, the applied location, number, and length of the plate and screws, and whether medial column buttress is restored. Improved fracture reduction, understanding the geometric distribution of screws, good intraoperative fluoroscopy, and reconstruction of medial column buttress stability are the key points for success. ConclusionThe risk of the intra-articular screw penetration in the proximal humeral fractures treated with locking plates is still high. Follow-up studies need to further clarify the cause and mechanism of screw penetration, and the risk factors that lead to screw penetration, in order to effectively prevent the occurrence of this complication.

    Release date:2021-04-27 09:12 Export PDF Favorites Scan
  • Current status and progress of locking plate in the treatment of distal femoral comminuted fracture

    ObjectiveTo review the current status and progress of locking plate for the treatment of distal femoral comminuted fractures.MethodsThe related literature was extensively reviewed to summarize the current status and progress in the treatment of distal femoral comminuted fracture with locking plate from four aspects: the current treatment situation, the shortcomings of locking plate and countermeasures, the progress of locking technology, locking plate and digital orthopedic technology.ResultsTreatment of distal femoral comminuted fractures is challenging. Locking plates, the most commonly used fixation for distal femoral comminuted fractures, still face a high rate of treatment failure. Double plates can improve the mechanical stability of comminuted fractures, but specific quantitative criteria are still lacking for when to choose double plates for fixation. The far cortial locking screw has shown good application value in improving the micro-movement and promoting the growth of callus. The biphasic plating is a development of the traditional locking plate, but needs further clinical examination. As an auxiliary means, digital orthopedic technology shows a good application prospect.ConclusionThe inherent defect of locking plate is a factor that affects the prognosis of distal femoral comminuted fracture. The optimization of locking technology combined with digital orthopedic technology is expected to reduce the failure rate of treatment of distal femoral comminuted fracture.

    Release date:2021-10-28 04:29 Export PDF Favorites Scan
  • SHORT-TERM EFFECTIVENESS OF RECONSTRUCTIVE LOCKED PLATE FOR TREATING STERNOCLAVICULAR JOINT DISLOCATION

    Objective To investigate the short-term effectiveness of reconstructive locked plate for treating sternoclavicular joint dislocation. Methods Between February 2008 and February 2012, 11 patients with sternoclavicular joint dislocation were treated with reconstructive locked plate, and the clinical data were retrospectively analyzed. There were 7 males and 4 females, aged 30-55 years (mean, 44 years). The causes of injury included traffic accident in 8 cases and crashing in 3 cases. The disease duration ranged from 2 hours to 11 days (median, 6 days). All patients had anterior dislocation of sternoclavicular joint. According to the Grade system, there were 2 cases of type II and 9 cases of type III. Results All patients obtained healing of incisions by first intention after operation. There was no neurovascular injury. The X-ray films showed that satisfactory reduction of joint dislocation and stable internal fixation were obtained at 2 days after operation. All patients were followed up 9-24 months (mean, 16 months). According to the Rockwood criteria, the score was 10-15 (mean, 13.2); the results were excellent in 9 cases and good in 2 cases, with an excellent and good rate of 100% at 9 months after operation. No internal fixation failure or re-dislocation occurred. All internal fixators were removed at 9-15 months after operation. Both the stability and the functions of the shoulder joint were good. Conclusion The reconstructive locked plate in treating sternoclavicular joint dislocation has the advantages of good stability and satisfactory reduction, and the patients can do functional exercises early and obtain good recovery of the shoulder joint function. The short-term effectiveness is satisfactory.

    Release date:2016-08-31 10:53 Export PDF Favorites Scan
  • 股骨近端锁定钢板治疗老年股骨转子间骨折

    目的 总结股骨近端锁定钢板在治疗老年股骨转子间骨折的手术经验及成功率。 方法 对2008年1月-2009年3月收治的57例老年股骨转子间骨折患者,行切开复位股骨近端锁定钢板内固定治疗。 结果 在Evans分型1~5型中手术成功率为100%,优良率为98.2%。 结论 股骨近端锁定钢板适用于老年股骨转子间骨折的各种类型。

    Release date:2016-09-08 09:47 Export PDF Favorites Scan
  • EFFECTIVENESS OF LOCKING PLATES FOR Neer THREE- AND FOUR-PART PROXIMAL HUMERUS FRACTURES

    Objective To evaluate the effectiveness of locking plates for Neer 3- and 4-part proximal humerus fractures. Methods A retrospective analysis was made on the clinical data of 77 patients with 3- or 4-part proximal humerus fractures, who underwent open reduction and internal fixation of locking plates and were followed up more than 12 months between July 2008 and May 2011. There were 39 males and 38 females with an average age of 54.2 years (range, 18-81 years). Fractures were caused by falling in 47 cases, by traffic accident in 16 cases, by falling from height in 4 cases, by sporting in 5 cases, and by other reasons in 5 cases. The time between injury and operation was 2-16 days (mean, 4.5 days). According to Neer classification, there were 54 cases of 3-part fracture and 23 cases of 4-part fracture. The Constant scores, visual analogue score (VAS), and the complications were evaluated during follow-up. Results After operation, healing of incisions by first intention was obtained in 76 cases and healing by second intention in 1 case. All patients were followed up 12-36 months (mean, 18.5 months). At last follow-up, the Constant score was 71.1 ± 11.9; the results were excellent in 18 cases, good in 24 cases, fair in 25 cases, and poor in 10 cases with an excellent and good rate of 54.5%. The VAS score was 2.8 ± 2.2. Bone nonunion occurred in 2 cases; the other patients had bone union within 2-6 months (mean, 3.2 months). The complications occurred in 25 cases (32.5%). Revision surgery was performed in 15 patients (19.5%). Conclusion The treatment of Neer 3- and 4-part proximal humerus fractures remains challenging. Anatomic reduction, stable fixation, and reduced humeral head blood supply disruption may lead to a satisfactory outcome.

    Release date:2016-08-31 04:22 Export PDF Favorites Scan
  • 股骨近端锁定钢板治疗股骨转子间骨折

    目的 总结股骨近端锁定钢板(proximal femur locking plate,PFLP)微创治疗股骨转子间骨折的疗效。 方法 2007 年5 月- 2008 年10 月,采用PFLP 微创治疗股骨转子间骨折24 例,并与同期采用动力髋螺钉(dynamic hip screw,DHS)治疗的32 例股骨转子间骨折患者临床疗效进行比较。两组患者年龄、性别、致伤原因、骨折分型(AO 分型)、骨质量Singh 分级、受伤至入院时间等一般资料比较差异均无统计学意义(P gt; 0.05),具有可比性。 结果 术后2 组患者切口均Ⅰ期愈合。PFLP 组患者均获随访,随访时间12 ~ 14 个月,平均12.6 个月。患者骨折均解剖复位,达骨性愈合。DHS 组30 例获随访,随访时间12 ~ 20 个月,平均13.5 个月。除3 例于术后1 个月发现未达解剖复位外,其余患者骨折均解剖复位,达骨性愈合。PFLP 组切口长度、手术时间、术中失血量、术后负重时间均优于DHS 组(P lt; 0.05),骨折愈合时间两组比较差异无统计学意义(P gt; 0.05)。 结论 PFLP 是治疗股骨转子间骨折一种适宜选择,相比DHS 具有手术创伤小、手术时间短、并发症少等优点。

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
  • Effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture

    ObjectiveTo summarize the effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture.MethodsBetween January 2011 and October 2016, 25 cases with comminuted Jones fracture were treated with mini locking plate combined with Kirschner wire. There were 9 males and 16 females with an average age of 31.4 years (range, 16-66 years). The fractures located on the left side in 11 cases and on the right side in 14 cases. The causes of injury included spraining in 21 cases, falling down in 3 cases, and bruise in 1 case. The bone fragment of all cases was more than 3 pieces. The fracture line was mostly Y-shape or T-shape. Twelve of them were combined with other fractures. The time from injury to operation was 1-9 days (mean, 5 days). The mini locking plate and Kirschner wire were removed at 9-12 months postoperatively. At 12 months postoperatively, the pain was evaluated by the visual analogue scale (VAS) score, and the function by the American Orthopaedic Foot & Ankle Society (AOFAS) score.ResultsAll incisions healed by first intention. All cases were followed up 12-36 months with an average of 21.7 months. Fracture union was observed in all patients without complications such as nonunion, delayed union, and malunion. The fracture union time was 8-12 weeks (mean, 9.4 weeks). At 12 months postoperatively, the VAS score was 1.15±0.87; the AOFAS score was 89.45±6.24, and the results were excellent in 14 cases, good in 9 cases, fair in 1 case, and poor in 1 case, with an excellent and good rate of 92%.ConclusionThe procedure of mini locking plate combined with Kirschner wire for comminuted Jones fracture has such advantages as convenient operation, more rigid fixation, high rate of fracture healing, and good functional recovery in foot.

    Release date:2018-05-02 02:41 Export PDF Favorites Scan
  • A meta-analysis of the necessity of coracoclavicular ligament reconstruction in the treatment of unstable distal clavicular fractures with locking plate

    Objective To investigate the necessity of coracoclavicular ligament reconstruction in the treatment of unstable distal clavicular fracture with locking plate. Methods We searched PubMed, the Cochrane Library, Embase, China National Knowledge Infrastructure, Wanfang database and VIP database for all the articles about the treatment of unstable distal clavicular fractures using locking plate combined with coracoclavicular ligament reconstruction or locking plate alone from the establishment of databases to November 30th, 2022. According to the inclusion and exclusion criteria, we selected the documents that met the requirements of this paper, and extracted the effective data after evaluating the quality of the documents, including the Constant-Murley score, coracoclavicular distance, fracture healing time, complication rate, operative time, intraoperative blood loss, incision length and the Visual Analogue Scale score of postoperative pain. RevMan 5.4 software was used for meta-analysis. Results A total of 11 retrospective cohort studies were included, and the overall quality of the literature was high. A total of 421 cases were included in this study, including 209 cases in the locking plate combined with coracoclavicular ligament reconstruction group and 212 cases in the locking plate group. The results of meta-analysis showed that locking plate combined with coracoclavicular ligament reconstruction in the treatment of unstable distal clavicular fractures was superior to locking plate alone in the Constant-Murley score [mean difference (MD)=7.35, 95% confidence interval (CI) (2.84, 11.87), P=0.001], coracoclavicular distance [MD=–1.22 mm, 95%CI (–1.92, –0.53) mm, P=0.0006], fracture healing time [MD=–2.76 weeks, 95%CI (–4.74, –0.79) weeks, P=0.006] and complication rate [odds ratio=0.31, 95%CI (0.14, 0.68), P=0.004], but the former had longer operative time [MD=9.27 min, 95%CI (4.53, 14.01) min, P=0.0001]. There was no significant difference in the intraoperative blood loss [MD=3.31 mL, 95%CI (–17.01, 23.63) mL, P=0.75], incision length [MD=0.30 cm, 95%CI (–0.11, 0.71) cm, P=0.15], or Visual Analogue Scale score of postoperative pain [MD=–0.26, 95%CI (–0.79, 0.27), P=0.33]. Conclusions Although the reconstruction of the coracoclavicular ligament increases the time of surgery, locking plate combined with coracoclavicular ligament reconstruction in the treatment of unstable distal clavicular fractures is significantly better than locking plate alone in terms of reduction quality, shoulder function recovery, fracture healing time, and the incidence of complications, without significant intraoperative bleeding, prolonged incision or postoperative pain.

    Release date:2023-06-21 09:43 Export PDF Favorites Scan
  • EFFECT OF DIFFERENT NECK-SHAFT ANGLE ON EFFICACY IN TREATMENT OF PROXIMAL HUMERAL FRACTURES WITH LOCKING PLATE

    ObjectiveTo observe the influence of different humeral neck-shaft angle on the efficacy in the treatment of proximal humeral fractures with locking plate. MethodsA total of 106 patients with proximal humeral fractures were treated by locking plate between March 2009 and March 2013, and the clinical data were retrospectively analyzed. Of 106 cases, 58 were male and 48 were female, aged from 26 to 71 years (mean, 52.3 years). The causes were traffic accident injury in 54 cases, falling injury from height in 23 cases, falling injury in 21 cases, and others in 8 cases. According to the Neer classification, there were 32 cases of two-part fractures, 65 cases of three-part fractures, and 9 cases of four-part fractures. The time from injury to operation was 1-7 days (mean, 2.7 days). According to neck-shaft angle by X-ray measurements at 1-3 days after operation, the patients were divided into 3 groups:valgus group (>145°), normal group (126-145°), and varus group (<126°) to observe the influence of neck-shaft angle on efficacy. ResultsAccording to postoperative humeral neck-shaft angle, there were 10 cases in valgus group, 75 cases in normal group, and 21 cases in varus group. There was no significant difference in general clinical data among 3 groups (P>0.05). The patients were followed up 6-12 months. The X-ray results showed fracture healing, and no significant difference was found in fracture healing time among 3 groups (P>0.05). After 6 months, the varus angle of femoral head and visual analogue scale (VAS) score of normal group were significantly lower than those of valgus group and varus group (P<0.05). The excellent and good rate of Constant-Murley score was 78.67% (59/75) in normal group, and it was significantly higher than that in valgus group (60.00%, 6/10) and varus group (42.86%, 9/21) (P<0.05), but there was no significant difference between valgus group and varus group (P>0.05). The complication rate was 28.57% (6/21) in varus group, was 10.67% (8/75) in normal group, and was 20.00% (2/10) in valgus group, showing no significant difference among 3 groups (χ2=4.31, P=0.12). ConclusionReconstruction of normal neck-shaft angle is the key to good shoulder function and clinical efficacy in the treatment of proximal humeral fracture.

    Release date: Export PDF Favorites Scan
  • 锁定钢板联合纽扣钢板线缆系统治疗Weber-C型踝部骨折

    目的 总结采用锁定钢板联合纽扣钢板线缆系统治疗Weber-C型踝部骨折的疗效。 方法 2011年2月-9月,对25例Weber-C型踝部骨折采用锁定钢板固定外踝、空心螺钉固定内踝及后踝、纽扣钢板线缆系统重建下胫腓联合治疗。男16例,女9例;年龄22~44岁,平均33.4岁。致伤原因:扭伤14例,交通事故伤9例,高处坠落伤2例。左侧12例,右侧13例。受伤至手术时间2~7 d,平均2.6 d。 结果术后第2天踝部正侧位X线片检查示,下胫腓联合间隙、踝穴均恢复正常。患者切口均Ⅰ期愈合,无相关并发症发生。25例均获随访,随访时间12~28个月,平均25.2个月。骨折均愈合,愈合时间9~13个月,平均12个月;无骨折复位丢失以及下胫腓联合固定失效发生。术后12个月根据美国矫形足踝协会(AOFAS)踝关节功能评分系统评分,获优21例,良4例,优良率为100%。 结论锁定钢板联合纽扣钢板线缆系统治疗Weber-C型踝部骨折,避免了单螺钉固定下胫腓联合的相关并发症,近期疗效满意。

    Release date:2016-08-31 10:53 Export PDF Favorites Scan
6 pages Previous 1 2 3 ... 6 Next

Format

Content