west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "静脉移植" 31 results
  • 静脉移植延长血管蒂的腓骨皮瓣临床应用

    目的 探讨双侧小腿严重创伤的感染性骨骼与皮肤缺损的修复方法。 方法 2000年3月~2004年6月,收治3例双侧小腿严重创伤患者,年龄22~38岁,均为男性。一侧小腿为主干血管长段损伤致感染性皮肤骨骼缺损,另一侧为胫骨粉碎性骨折合并软组织损伤,骨折已愈合,局部贴骨瘢痕形成。皮肤缺损范围9 cm×6 cm~13 cm×9 cm,骨骼缺损6~10 cm。3例均采用静脉移植延长血管蒂的腓骨皮瓣并腿移位修复。 结果 1例于术后第2天出现血管危象,经探查排除血栓,重新吻合血管后危象解除。另2例骨皮瓣均完全成活。3例均于术后6周断蒂,术后3~5个月,腓骨瓣与受区胫骨达骨性愈合。随访2年,双下肢均可负重行走,步态正常,膝、踝关节屈伸活动可,恢复正常生活与工作。结论 应用延长血管蒂的腓骨皮瓣并腿移位治疗双侧肢体血管损伤,或胫骨骨折的小腿感染性骨骼皮肤缺损,能使患肢避免截肢并恢复一定功能。

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • A NEW METHOD TO REPAIR ARTERY INJURIES IN EXTREMITIES BY PHLEBOPLASTY OF BRANCHED VEIN GRAFT

    In order to develope a new method to overcome the difficulties in anastomosis of blood vessels with different diameter, phleboplasty was utilized at the join-point to expand the diameter of branched vein graft, with a funnel-shaped stoma formed consequently. After successfully experimented in fresh blood vessels in vitro, the method was practised clinically to repair injured arteries in extremities, with the outcome that phleboplasty of branched vein graft could enlarge the diameter by 1-1.25 times, and with satisfied effects in 3 clinic cases. So, the conclusion was that: phleboplasty of branched vein graft was a new effective and convinient method to repair injured arteries with different diameters

    Release date:2016-09-01 11:07 Export PDF Favorites Scan
  • LONGITUDINAL BIOMECHANICAL EFFECT ON REPAIR OPTIONS OF ARTERY INJURY

    OBJECTIVE: To investigate the relationship between the different defect length of vessels and the options of vascular repair, and to compare the different options of repair because of the longitudinal biomechanical effect. METHODS: A clinical analysis was undertaken to evaluate the major arterial and venous injuries in human extremities repaired by end-to-end anastomoses or venous autograft(177 cases, 185 vessels). Compared the defect length of the same kind of vessels repaired by different options (Student-t test). Evaluated the defect length to repair arterial injuries between by end-to-end anastomoses and by vein graft by means of 95% confidence interval. RESULTS: There was significant difference between the defect length of brachial artery repaired by end-to-end anastomosis and femoral artery and popliteal artery repaired by autogenous vein graft (P lt; 0.01). The upper limit of confidence interval in the defect length of brachial artery, femoral artery and popliteal artery was 3.17 cm, 2.81 cm and 2.44 cm respectively by end-to-end anastomosis by means of 95% confidence interval. The lower limit of confidence interval in the defect length of brachial artery, femoral artery and popliteal artery was 2.82 cm, 2.41 cm and 2.17 cm respectively by vein graft by means of 95% confidence interval. The defect length of brachial artery, femoral artery and popliteal artery repaired by vein graft was linear correlation with the length of graft. CONCLUSION: Because of the longitudinal biomechanical difference of arteries and veins in human extremities, different options of repair are necessary to different arterial injuries.

    Release date:2016-09-01 10:26 Export PDF Favorites Scan
  • QUANTITATIVE ANALYSIS OF LIQUID DISTENSION EFFECTS ON MICROSTRUCTURAL COMPONENTS OF GRAFTED VEINS

    The femoral veins were excised from 28 dogs and distended with pressure of 40, 80 and 120 kPa, respectively before grafted to femoral arteries. The veins were harvested at different times and Pollak sections were prepared which revealed different stains of elastin, collagen and smooth muscle in each section. The sections were led to image analysis system to computerize the relative contents of theabove components. The results were as follows: Elastin decreased significantly at 4 weeks (P lt;0.01), and was constant between 4 and 16 weeks. No statistical difference was found in 40, 80 kPa and the control group (P gt;0.05), but the elastin of 120 kPa group by the 16th week was still decreasing. Collagen of each group had no difference, but C/E increased significantly with time. Smooth muscle contents were correlated positively with time, and negatively with the pressure at 1 week, then positively with the pressure at 16th week. The changes of the above trends were the same as development of intimal hyperplasia. The contentions were the value of C/E was determined by the arterial pressure but that of 120 kPa pressure was more higher. The preimplant pressure distension was a possible significantfactor leading to excessive intimal hyperplasia of early and middle stage of autogenous vein grafts.

    Release date:2016-09-01 11:13 Export PDF Favorites Scan
  • 大鼠静脉移植模型建立的常见并发症防治

    目的 探讨大鼠自体静脉移植模型建立常见并发症的预防和处理措施。 方法 采用两点定位法,将65 只大鼠的右侧颈外静脉分支与同侧颈总动脉断端行间断全层外翻端端吻合。通过吻合后血管充盈和搏动情况及远端勒血实验来确定吻合口通畅。从术中操作和术后护理的角度,分析常见并发症的发生原因及相应的防治措施。 结果 65 只大鼠自体颈静脉移植,52 只实验成功,成功率80.0(52/65),其中术中死亡率7.7%(5/65),术后死亡率12.3%(8/65)。导致大鼠术中死亡的主要原因有麻醉意外、呼吸道分泌物阻塞窒息、触碰迷走神经突发心搏骤停、失血性休克;术后死亡的主要原因有吻合口漏血、血管空气栓塞、吻合口血栓形成或闭塞、感染。 结论 实验过程中熟悉各种并发症发生的原因和防治措施,提高手术技巧,可减少并发症的发生,提高手术成功率,达到预期的模型建立效果。

    Release date:2016-08-30 05:48 Export PDF Favorites Scan
  • APPLICATION OF CROTCH-SHAPED VEIN GRAFTS IN REPAIRING DEFECTS OF THEVESSELS WITH A LARGE DIAMETER

    Objective To investigate the results and applicationvalue of crotch-shaped vein grafts in repairing defects of the vessels with a large diameter.Methods From June 1998 to October 2003, 35 cases of vesseldefects with a large diameter were repaired with crotch-shaped vein graft (29 males and 6 females,aged 18 to 45 years with an average of 25.7 years ). The locations of defects were femoral artery in 25 cases, popliteal artery in 2 cases, femoral vein in 7 cases, and subclavian vein in 1 case. The interval between injure and operatioinwas 1-8.5 hours (4.1 hours on average).The blood flows of trouble and healthy vascular were determined with Doppler detector and compared preoperatively andpostoperatively. Results All the anastomotic stomas were patent in 35 cases. Thirty-one cases were followed up 6 weeks to 24 months (9.5 months on average), the patent rate was 100%, no case occurred vasospasm or tromboembolism; 2 cases occurred stomal leak and became hematoma, 3 cases occurred muscular necrosis, and the 5 cases achieved primary healing after secondary operation. The Doppler results showed that there was statistically significant difference in the blood flow betweenpostoperation and preoperation (Plt;0.01), but no statistically significant difference when compared the trouble vascular after operation with healthy vascular (Pgt;0.05). Conclusion The methodof crotch-shaped vein grafts is safe and effective in repairing defects of vessels with a large diameter,which is easy to draw materials and handy to operate. It has a promising value in clinical application.

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
  • Inhibitory effect and mechanism of epigallocatechin-3-gallate on autogenous vein graft stenosis in rat models

    Objective To investigate the effect and mechanism of epigallocatechin-3-gallate (EGCG) on restenosis of the vein graft. Methods Totally 90 Sprague-Dawley rats were randomly divided a the control group, a vein graft group and an EGCG+vein graft group. At week 1, 2 and 4, the intimal and tunica thickness of the venous graft wall was evaluated by hematoxylin-eosin staining, and the expression of Ki-67 was assessed by immunohistochemistry analysis, and then the expression of hairy and enhancer of split-1 (HES1) was measured by Western blot assay. Results At week 2, the intimal thickness (46.76±4.89 μmvs. 8.93±0.82 μm, 46.76±4.89 μmvs. 34.24±3.57 μm), tunica thickness (47.28±4.37vs. 16.33±1.52 μm, 47.28±4.37vs. 36.27±3.29 μm), positive cell rate of Ki-67 (21.59%±2.29%vs. 1.12%±0.22%, 21.59%±2.29%vs. 15.38%±1.30%), expression of HES1 respectively increased in the experimental group than those in the control group and the EGCG+vein graft group (P<0.05, respectively). At week 4, the intimal thickness (66.38±6.23 μmvs. 8.29±0.79 μm, 66.38±6.23 μmvs. 48.39±4.23 μm), tunica thickness (63.27±6.18 μmvs. 15.29±1.49 μm, 63.27±6.18 μmvs. 44.63±4.49 μm), positive cell rate of Ki-67 (33.19%±3.03%vs. 1.09%±0.19%, 33.19%±3.03%vs. 24.37%±2.73%), expression of HES1 increased in the experimental group than those in the control group and EGCG+vein graft group (P<0.05, respectively). Conclusion EGCG may inhibite restenosis of vein graft by inhibiting Notch signal pathway.

    Release date:2017-09-26 03:48 Export PDF Favorites Scan
  • Expression of Receptor of Advanced Glycation End Products and Effect of Aminoguanidine on Intimal Hyperplasia in Autogenous Vein Graft of Rats with Streptozotocin Induced Diabetes

    Objective To study the expression of receptor of advanced glycation end products (RAGE) in autogenous vein graft of streptozotocin induced diabetic rats and the inhibitory effects of aminoguanidine on intimal hyperplasia. Methods Sixty male Sprague-Dawley rats were randomly divided into three groups: aminoguanidine group, distilled water group and control group. Autogenous vein graft models were established in all groups. Streptozotocin was injected into abdominal cavity to induce diabetes in both aminoguanidine group and distilled water group, and they were intragastric administrated with aminoguanidine or distilled water, respectively before and after transplantation. Specimens were collected from autogenous vein graft 7 days and 14 days after surgery to undergo histological examination. At the same time, the level of serum advanced glycation end products (AGE) was tested. Western blotting and immunohistochemistry were used to detect the protein expression of RAGE and NF-κB p65. RAGE and NF-κB p65 mRNA were measured by reverse transcription-PCR. Results  The mRNA and protein expressions of RAGE, NF-κB p65, the level of serum AGE and the intimal thickness of vein graft in distilled water group increased in comparison with those in control group 7 days and 14 days after surgery (P<0.05). The level of serum AGE, mRNA and protein expressions of NF-κB p65 and the intimal thickness of vein graft in aminoguanidine group were lower than those in distilled water group (P<0.05), and showed no significant difference compared with control group (P>0.05). Conclusion The over-expression of RAGE in vein graft activats NF-κB in streptozotocin-induced diabetic rat, which has a close relation with intimal hyperplasia. Aminoguanidine can block the binding of AGE and RAGE by inhibiting the production of AGE, which will prevent intimal hyperplasia of vein graft.

    Release date: Export PDF Favorites Scan
  • 自体大隐静脉移植治疗肾移植术后感染性髂外动脉破裂一例

    Release date:2016-08-31 04:05 Export PDF Favorites Scan
  • INHIBITORY EFFECT OF TOPICAL APPLICATION OF 5-FLUOROURACIL ON INTIMAL HYPERPLASIA OF VEIN GRAFT

    Objective To assess the effect of topical appl ication of 5-fluorouracil (5-FU) on intimal hyperplasia in rabbit vein graft. Methods Sixty-four male New Zealand white rabbits, aged 5 months and weighing 2.8-3.0 kg, were randomly divided into group A, B, C, and D (n=16 rabbits per group). Artery defect model was establ ished by cutting about 1 cm artery from the middle part of the dissociated left common carotid artery. A section about 3 cm was cut from the right external jugular vein, and the harvested vein was inverted and end-to-end anastomosed to the artery defect with 9-0 non-traumatic suture. After anastomosis, the extima of the grafted veins in group A, B, and C was completely wrapped with cotton sheet (12 mm × 30 mm × 1 mm in size) immersed by 5-FU at a concentration of 50.0, 25.0, and 12.5 mg/mL, respectively, and eachvein was treated 5 times (1 minute at a time). In group D, the extima of the graft veins was treated with normal sal ine instead of 5-FU. The grafted veins were obtained 1, 2, 4, and 6 weeks after operation, HE staining and Masson staining were preformed for histological changes of grafted vein wall, prol iferating cell nuclear antigen (PCNA) immunohistochemistry staining and TUNEL label ing staining were conducted for prol iferation and apoptosis of smooth muscle cell of the grafted vein, and transmission electron microscope observation was performed for cellular ultrastructure. Results The HE staining, Masson staining, and PCNA immunohistochemistry staining showed that the thickness of intima in group A and B was obviously less than that in group C and D at 1, 2, 4, and 6 weeks after operation, and the prol iferation cells in group A and B were less than that in group C and D at 1, 2, and 4 weeks after operation. The thickness of the intima, the degree of intima hyperplasia, the degree of vessel lumen stenosis of four groups at different time points were as follows: at 1 week after operation, group A [(12.69 ± 1.68) μm, 0.73 ± 0.05, 0.025 ± 0.003], group B [(17.52 ± 2.01) μm, 0.86 ± 0.06, 0.027 ± 0.004], group C [(21.92 ± 1.85) μm, 1.06 ± 0.09, 0.036 ± 0.006] and group D [(26.45 ± 3.86) μm, 1.18 ± 0.08, 0.041 ± 0.005]; at 2 weeks after operation, group A [(24.61 ± 2.91) μm, 0.86 ± 0.06, 0.047 ± 0.003], group B [(37.28 ± 2.78) μm, 1.17 ± 0.09, 0.060 ± 0.004], group C [(46.52 ± 2.25) μm, 1.44 ± 0.08, 0.073 ± 0.003], and group D [(52.07 ± 3.29) μm, 1.45 ± 0.05, 0.081 ± 0.006]; at 4 weeks after operation, group A [(61.09 ± 6.84) μm, 1.38 ± 0.08, 0.106 ± 0.007], group B [(63.61 ± 8.25) μm, 1.40 ± 0.07, 0.107 ± 0.010], group C [(80.04 ± 7.65) μm, 1.64 ± 0.07, 0.129 ± 0.011], and group D [(84.45 ± 9.39) μm, 1.68 ± 0.10, 0.139 ± 0.014]; at 6 weeks after operation, group A [(65.27 ± 5.25) μm, 1.46 ± 0.07, 0.113 ± 0.005], group B [(65.82 ± 7.12) μm, 1.45 ± 0.05, 0.112 ± 0.011], group C [(84.45 ± 9.39) μm, 1.69 ± 0.09, 0.135 ± 0.007], and group D [(87.27 ± 8.96) μm, 1.76 ± 0.05, 0.140 ± 0.012]. Group A and B were inferior to group C and D in terms of the above three parameters and cell prol iferation index 1, 2 and 4 weeks after operation (P lt; 0.05). Group A and B were superior to group C and D in terms of cell apoptosis index of intima and media 1 and 2 weeks after operation (P lt; 0.05). Transmission electron microscope observation showed that the synthetic cell organelles such as rough endoplasmic reticulum, golgi apparatus, and ribosome in group A and B were obviously less than those in group C and D (P lt; 0.05). Conclusion Topicalappl ication of 5-FU can effectively inhibit intima hyperplasia of the vein grafts.

    Release date:2016-09-01 09:07 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content