west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "骨折" 1540 results
  • APPLICATION OF ENHANCED GREEN FLUORESCENT PROTEIN LABELING TECHNOLOGY TO MONITO RING MARROW MESENCHYMAL STEM CELLS MIGRATION AFTER BONE FRACTURE

    Objective To monitor the stem cell migration into the bone defect following an injection of the labeled mesenchymal stem cells (MSCs) by the enha nced green fluorescent protein (EGFP)technology and to provide insights into an application of MSCs for the fracture healing. Methods Isolated MSCs from the rabbit femur marrow were culture-expanded and were labeled by the transfection with the recombinant retrovirus containing the EGFP gene. Then, some labeled MSCs were cultured under the osteogenic differentiation condition and the phenotype was examined. After the fracture of their bilateral ulna, 18 rabbits were divide d into two groups. The labeled MSCs were injected into the aural vein at 1×107 cells/kg in the experimental group and the unmarked MSCs were injected in the control group 24 hours before surgery, and 1 and 24 hours after surgery, res pectively. Necropsies were performed 2 days after surgery in the two groups. The sections from the left defects were observed under the fluorescence microscope and the others were analyzed by the bright-field microscopy after the HE staining. Results The EGFP did not affect the MSCs viability. After the labeled cells were incubated in the osteogenic medium alkaline phosphatase, the calcium nodule s were observed. All the rabbits survived. The tissue of haematoma was observed in the bone defects and the fluorescent cells were found in the experimental gr oup, but no fluorescent cells existed in the control group. Conclusion The EG FP labeled MSCs can undergo osteogenic differentiation in vitro and can mig rate into bone defects after their being injected into the peripheral vein.

    Release date:2016-09-01 09:25 Export PDF Favorites Scan
  • 闭合复位经胫后空心钛钉内固定在三踝骨折时后踝骨折的应用

    目的 总结闭合复位经胫后空心钛钉内固定治疗三踝骨折时后踝骨折的临床效果。 方法 2004 年6 月- 2007 年1 月,采用闭合复位经胫后应用空心钛钉内固定治疗三踝骨折时后踝骨折30 例。男16 例,女14 例;年龄20 ~ 65 岁,平均45 岁。左侧18 例,右侧12 例,均为闭合骨折。根据Lange-Hansen 分型:Ⅲ、Ⅳ度旋后- 外旋型17 例,Ⅳ度旋前- 外旋型10 例,Ⅱ度旋前- 外展型3 例。后踝骨折均超过关节面的25%,均合并内、外踝骨折。伤后至手术时间为5 ~ 11 d。 结果 3 例复位困难行切开复位内固定,术中见后踝为粉碎性骨折,有骨块嵌顿,不能复位。术后切口均Ⅰ期愈合。27 例获随访,随访时间12 ~ 48 个月,平均31.2 个月。骨折全部愈合,愈合时间81 ~ 108 d,平均87 d,无断钉等并发症。疗效根据Baird-Jackson 标准进行评定,优18 例,良5 例,可3 例,差1 例,优良率为85.2%。平均恢复工作时间为70 d。 结论 闭合复位经胫后空心钛钉内固定是治疗后踝骨折的有效方法之一 。

    Release date:2016-09-01 09:18 Export PDF Favorites Scan
  • Research progress on intra-articular screw penetration in proximal humeral fracture treated with locking plate

    ObjectiveTo review the research progress on intra-articular screw penetration in proximal humeral fracture treated with locking plate. MethodsThe domestic and foreign literature about the proximal humeral fracture treated with locking plate was extensively reviewed. The incidence of screw penetration and risk factors were summarized from both primary and secondary screw penetrations, and the reasons of the intra-articular screw penetration and the technical solutions to avoid the penetration were analyzed. ResultsThe incidence of intra-articular screw penetration is about 11%-30%, which includes primary and secondary screw penetrations. The primary screw penetration is related to improper operation, inaccurate measurement, and “Steinmetz solid” effect, which results in inadequate fluoroscopy and blind zone. The secondary screw penetration is related to the loss of reduction and varus, collapse, and necrosis of the humeral head. The risk factors for intra-articular screw penetration include the bone mass density, the fracture type, the quality of fracture reduction, the applied location, number, and length of the plate and screws, and whether medial column buttress is restored. Improved fracture reduction, understanding the geometric distribution of screws, good intraoperative fluoroscopy, and reconstruction of medial column buttress stability are the key points for success. ConclusionThe risk of the intra-articular screw penetration in the proximal humeral fractures treated with locking plates is still high. Follow-up studies need to further clarify the cause and mechanism of screw penetration, and the risk factors that lead to screw penetration, in order to effectively prevent the occurrence of this complication.

    Release date:2021-04-27 09:12 Export PDF Favorites Scan
  • Analysis of the Radiological Performance of the Lower Limbs Fracture in Wenchuan Earthquake

    目的:着重分析汶川地震中伤员下肢骨折的发生部位、类型及其产生机制和临床意义。方法:对5·12汶川大地震发生后近2个月内先后送至四川大学华西医院治疗的496例下肢骨折伤员,按X线检查结果对骨折部位及类型进行分析。结果:下肢多部位粉碎性骨折而截肢者29例(5.8%),其余467例伤员共584个部位发生骨折。按骨折部位分类:股骨162个(27.7%),胫腓骨275个(47.1%),髌骨19个(3.3%)以及足骨128个(21.9%)。按骨折类型分类:粉碎性骨折244个(41.8%),斜行骨折194个(33.2%),横行骨折53个(9.1%),线性骨折35个(6.0%),螺旋形骨折33个(5.7%),嵌插骨折17个(2.9%),凹陷性骨折2个(0.3%),同一部位(胫腓骨骨干)的多种类型骨折6个(1.0%)。结论:本组汶川地震造成的下肢骨折,部位以胫腓骨为主;类型以粉碎性骨折为主。常规X线检查对下肢骨折伤员具有简便、快速和准确的诊断价值。

    Release date:2016-09-08 09:56 Export PDF Favorites Scan
  • SCREW-BASED INTERMAXILLARY TRACTION COMBINED WITH OCCLUSAL SPLINT FOR TREATMENT OF PEDIATRIC MANDIBULAR CONDYLAR FRACTURE

    ObjectiveTo evaluate the effectiveness of the screw-based intermaxillary traction combined with occlusal splint in the treatment of pediatric mandibular condylar fracture. MethodsBetween June 2005 and December 2013, 35 pediatric patients with 49 mandibular condylar fractures were treated, and the clinical data were retrospectively reviewed. There were 25 boys and 10 girls, aged 3-13 years (mean, 7.3 years). The injury causes included falling (18 cases), traffic accident (14 cases), and violence (3 cases). The time between injury and treatment was 2-30 days (mean, 6.8 days). Restricted mouth opening was observed, and the maximal mouth opening was (22.74±7.22) mm except 3 patients who were too young to measure. Condylar fractures were located at the left (12 cases), at the right (9 cases), at bilateral (14 cases) based on the sites; and fractures were classified as intra-capsular (35 fractures), neck (10 fractures), and subcondylar (4 fractures) based on the fracture line. Four self-drilling titanium screws were inserted into the alveolar bone of both maxilla and mandible. After screw inserting, an occlusal splint with a fulcrum was used on the affected side and elastic band was put to perform anterior intermaxillary traction. After 1 month, the screws and splint were removed. Follow-up examinations were carried out on schedule. ResultsAll the patients were followed up from 6 months to 8 years and 10 months (median, 71 months). No screw-related complication occurred in the others except one case of screw loosening. The postoperative maximal mouth opening was (38.82±2.02)mm. Mild joint noise was found in 4 cases and opening deviation occurred in 6 cases. Radiographic results demonstrated complete condyle remodeling was achieved in 24 cases (32 fractures), and moderate remodeling in 11 cases (17 fractures) at last follow-up. ConclusionThe screw-based intermaxillary traction combined with occlusal splint might be an effective method for pediatric mandibular condylar fracture. The screw-related complications may be avoided by careful preoperative investigations.

    Release date: Export PDF Favorites Scan
  • EFFECTIVENESS OF POSTERIOR MALLEOLUS FIXATION IN TREATING ANKLE FRACTURE

    Objective To evaluate the effectiveness of posterior malleolus fixation on the function of ankle in patients with ankle fracture. Methods Between June 2007 and June 2009, 110 patients with ankle fracture were treated with posteriormalleolus fixation in 59 patients (fixation group) or without fixation in 51 patients (non-fixation group). In fixation group, there were 31 males and 28 females with an average age of 62.6 years (range, 19-75 years); the causes of injury included traffic accident (20 cases), falling (18 cases), and sprain (21 cases) with a disease duration of 1-3 days (2.2 days on average); and the locations were left ankle in 32 cases and right ankle in 27 cases, including 6 cases of type I, 23 of type II, 19 of type III, and 11 of type IV according to the ankle fracture clssification. In non-fixation group, there were 38 males and 13 females with an average age of 64.5 years (range, 16-70 years); the causes of injury included traffic accident (15 cases), falling (12 cases), and sprain (24 cases) with a disease duration of 1-3 days (2.5 days on average); and the locations were left ankle in 22 cases and right ankle in 29 cases, including 8 cases of type I, 16 of type II, 19 of type III, and 8 of type IV according to the ankle fracture clssification. There was no significant difference in general data between 2 groups (P gt; 0.05). Results All patients of 2 groups achieved wound heal ing by first intention. The patients were followed up 12-18 months (16 months on average). X-ray films showed that fractures healed at 8-12 weeks (10 weeks on average) in fixation group and at 10-14 weeks (12 weeks on average) in non-fixation group. There were significant differences in the cl inical score (89.28 ± 8.62 vs. 86.88 ± 9.47, P lt; 0.05), postoperative reposition score (33.34 ± 2.15 vs. 31.24 ± 2.89, P lt; 0.05), and osteoarthritis score (13.22 ± 1.66 vs. 12.46 ± 2.03, P lt; 0.05) according to Phill i ps ankle scoring system between 2 groups at last follow-up. There was no significant difference in cl inical score of type I and II patients between 2 groups (P gt; 0.05), but significant differences were found in cl inical score and osteoarthritis score of type III and IV patients between 2 groups (P lt; 0.05). There were significant differences in the postoperative reposition score between 2 groups in all types of fractures (P lt; 0.05). Conclusion The posterior malleolus fixation may provide satisfactory cl inical functional outcomes for ankle fracture. Proper fracture classification and correct method of internal fixation are important for achieving good reduction and improving the long-term results.

    Release date:2016-09-01 09:04 Export PDF Favorites Scan
  • Effectiveness of one-stage total knee arthroplasty with tibial stem extender for knee arthritis complicated with tibial stress fracture

    ObjectiveTo evaluate the early effectiveness of one-stage total knee arthroplasty (TKA) with tibial stem extender for knee arthritis complicated with tibial stress fractures. MethodsBetween January 2014 and November 2016, 12 patients (12 knees) with knee arthritis and tibial stress fractures underwent one-stage TKA with tibial stem extender. There were 5 males and 7 females with an average age of 71.5 years (range, 60-77 years). There were 8 cases with osteoarthritis and 4 cases with rheumatoid arthritis. The radiographic examination showed the 6 cases of intra-articular fractures and 6 of extra-articular fractures (including transverse fractures in 4 cases and short oblique fractures in 2 cases); 2 cases complicated with middle and upper fibular fractures; 12 cases of varus deformities. Preoperative Knee Society Score (KSS) clinical score was 31.5±8.4 and functional score was 33.3±9.0. The preoperative range of motion (ROM) of the knee was (65.6±9.6)°. ResultsAll incisions healed primarily and no wound infection or skin necrosis occurred. All patients were followed up 36.5 months on average (range, 6-52 months). X-ray films showed that all fractures healed at 3-7 months (mean, 4 months); the position of the prosthesis was good, and no loosening or signs of infection occurred. At last follow-up, the KSS clinical score was 90.5±8.9 and functional score was 92.1±7.8; the ROM of the knee was (115.0±9.8)°. All indexes were significantly improved than those before operation (t=40.340, P=0.000; t=32.120, P= 0.000; t=8.728, P=0.000). ConclusionOne-stage TKA with tibial stem extender for patients with knee arthritis and tibial stress fractures can restore limb alignment, facilitate fracture healing, and obtain the satisfactory early effectiveness.

    Release date:2018-09-03 10:13 Export PDF Favorites Scan
  • Preliminary study on osteoporosis screening among postmenopausal patients with maintenance hemodialysis

    ObjectiveTo preliminarily explore the effect of Osteoporosis Self-assessment Tool for Asians (OSTA) and Fracture Risk Assessment Tool (FRAX) on predicting osteoporosis and osteoporosis fracture in postmenopausal patients with maintenance hemodialysis (MHD).MethodsThirty-six postmenopausal patients undergoing MHD from August 2017 to October 2018 in Hemodialysis Center of Nephrology Department, West China Hospital of Sichuan University were selected. Relevant data such as age, height, and weight were collected. OSTA index and the 10-year probability of major osteoporotic fractures and 10-year probability of hip fractures of FRAX score were calculated. Bone mineral densities (BMD) of the hip and lumbar spine were measured by dual energy X-ray absorptiometry (DXA) at the same time. The value of OSTA index and FRAX scale in evaluating the risk of osteoporosis predicated on T value ≤−2.5 determined by DXA BMD and fracture in postmenopausal patients with MHD were analyzed.ResultsThe DXA BMD of the 36 patients showed that 50.0% (18/36) had a T value≤−2.5, and 30.6% (11/36) had a fracture history. BMD in postmenopausal patients with MHD was negatively correlated with FRAX score (model without BMD values), and positively correlated with OSTA index. The sensitivity and specificity of OSTA in the prediction of osteoporosis were 94.4% and 61.1%, respectively; and the sensitivity and specificity of FRAX (the model without BMD values) in the prediction of osteoporosis were 88.9% and 50.0%, respectively. The FRAX score with or without BMD had the same clinical value in predicting osteoporosis.ConclusionsPostmenopausal MHD patients have a higher risk of osteoporosis and fracture. Both OSTA index and FRAX scale can predict osteoporosis risk among postmenopausal MHD patients, and the FRAX scale with or without BMD has the same clinical value in predicting osteoporosis risk. In clinical work, for primary hospitals and dialysis centers lacking DXA, preliminary screening of osteoporosis in MHD patients can be performed with OSTA and FRAX scales.

    Release date:2019-08-15 01:18 Export PDF Favorites Scan
  • Effectiveness of guide plate with mortise-tenon joint structure combined with off-axis fixation in treatment of Pauwels type Ⅲ femoral neck fractures

    Objective To investigate the effectiveness of using 3 hollow compression screws combined with 1 screw off-axis fixation under the guidance of three-dimensional (3D) printed guide plate with mortise-tenon joint structure (mortise-tenon joint plate) for the treatment of Pauwels type Ⅲ femoral neck fractures. Methods A clinical data of 78 patients with Pauwels type Ⅲ femoral neck fractures, who were admitted between August 2022 and August 2023 and met the selection criteria, was retrospectively analyzed. The operations were assisted with mortise-tenon joint plates in 26 cases (mortise-tenon joint plate group) and traditional guide plates in 28 cases (traditional plate group), and without guide plates in 24 cases (control group). There was no significant difference in the baseline data of gender, age, body mass index, cause of injury, and fracture side between groups (P>0.05). The operation time, intraoperative blood loss, frequency of intraoperative fluoroscopy, incision length, incidence of postoperative deep vein thrombosis of lower extremity, pain visual analogue scale (VAS) score at 1 week after operation, and Harris score of hip joint at 3 months after operation were recorded and compared. X-ray re-examination was taken to check the quality of fracture reduction, fracture healing, and the shortening length of the femoral neck at 3 months after operation, and the incidences of internal fixation failure and osteonecrosis of the femoral head during operation. Results Compared with the control group, the operation time, intraoperative blood loss, and frequency of intraoperative fluoroscopy reduced in the two plate groups, and the quality of fracture reduction was better, but the incision was longer, and the differences were significant (P<0.05). The operation time and intraoperative blood loss were significantly higher in the traditional plate group than in the mortise-tenon joint plate group (P<0.05), the incision was significantly longer (P<0.05); and the difference in fracture reduction quality and the frequency of intraoperative fluoroscopy was not significant between two plate groups (P>0.05). There was 1 case of deep vein thrombosis of lower extremity in the traditional plate group and 1 case in the control group, while there was no thrombosis in the mortise-tenon joint plate group. There was no significant difference in the incidence between groups (P>0.05). All patients were followed up 12-15 months (mean, 13 months). There was no significant difference in VAS score at 1 week and Harris score at 3 months between groups (P>0.05). Compared with the control group, the fracture healing time and the length of femoral neck shortening at 3 months after operation were significantly shorter in the two plate groups (P<0.05). There was no significant difference between the two plate groups (P>0.05). There was no significant difference in the incidences of non-union fractures, osteonecrosis of the femoral head, or internal fixation failure between groups (P>0.05). Conclusion For Pauwels type Ⅲ femoral neck fractures, the use of 3D printed guide plate assisted reduction and fixation can shorten the fracture healing time, reduce the incidence of postoperative complications, and be more conducive to the early functional exercise of the affected limb. Compared with the traditional guide plate, the mortise-tenon joint plate can reduce the intraoperative bleeding and shorten the operation time.

    Release date:2025-03-14 09:43 Export PDF Favorites Scan
  • Effect of remote controlled injection manipulator system assisted percutaneous kyphoplasty for treatment of rupture of posterior vertebral osteoporotic vertebral fracture

    Objective To evaluate the effect of remote controlled injection manipulator system (RCIM) assisted percutaneous kyphoplasty (PKP) for the treatment of rupture of posterior vertebral osteoporotic vertebral fracture by comparing with intermittent hand bolus injection of bone cement during operation. Methods Between September 2010 and January 2016, a retrospective analysis was made on the clinical data of 48 senile patients with single segment rupture of the posterior vertebral osteoporotic thoracolumbar fracture undergoing PKP who accorded with the inclusion criteria. Of 48 patients, 22 received intermittent hand bolus injection of bone cement in the control group, and 26 received RCIM assisted bone cement perfusion in the trial group. There was no significant difference in age, gender, duration of disease, causes of injury, implicated vertebral bodies, bone mineral density T value, pain duration, preoperative visual analogue scale (VAS), relative vertebral body height in the anterior part, and posterior convex Cobb angle between groups (P>0.05). The bone cement perfusion time, the radiation dose of both doctors and patients, and the amount of bone cement injection were recorded; treatment effects were evaluated based on VAS score, posterior convex Cobb angle, relative ver-tebral body height in the anterior part, ratios of bone cement diffusion area and bone cement leakage rate. Results The patients were followed up for 6 months; no complications of toxic effect of bone cement, spinal cord or nerve root injuries, infection and vascular embolization occurred during follow-up period. There was no significant difference in bone cement injection amount and radiation dose of doctors between groups (P>0.05), but bone cement perfusion time, ratios of bone cement diffusion area, and radiation dose of patients were significantly lower in the trial group than the control group (P<0.05). Bone cement leakage was observed in 6 cases of the control group (27.27%) and 2 cases of the trial group (7.69%), showing significant difference between groups (χ2=4.850,P=0.029); no cement leakage into the spinal canal was found in both groups. VAS score, relative vertebral body height in the anterior part, and posterior convex Cobb angle were significantly improved at 3 days and 6 months after operation when compared with preoperative ones (P<0.05), but no significant difference was observed in the above indexes between groups at 3 days and 6 months after operation (P>0.05). Conclusion Satisfactory effectiveness can be achieved by applying RCIM assisted PKP for the treatment of rupture of posterior vertebral osteoporotic vertebral fracture. RCIM can shorten perfusion time, reduce radiation dose, and decrease incidence of bone cement leakage.

    Release date:2017-05-05 03:16 Export PDF Favorites Scan
154 pages Previous 1 2 3 ... 154 Next

Format

Content