west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "CT angiography" 18 results
  • Control Study on the Value of Head Boneless CT Angiography for Surface Shaded Display and Volume Computed Tomographic Digital Subtraction Angiography in Diagnosing Intracranial Aneurysms

    ObjectiveTo investigate the value of head boneless CT angiography (CTA) for surface shaded display (SSD) (hereinafter referred to as the SSD-CTA technology) and volume computed tomographic digital subtraction angiography (VCTDSA) in diagnosing intracranial aneurysms. MethodsWe collected the clinical data of 35 patients diagnosed to have intracranial aneurysm by VCTDSA between April 2013 and November 2014 from the First Affiliated Hospital of Chongqing Medical University. The original data were imported into the CT workstation of the First People's Hospital of Chengdu. Then, SSD-CTA technology was performed for bone reconstruction. We compared the results of these two technologies. In addition, we selected another 27 patients diagnosed with intracranial aneurysm by SSDCTA and DSA examination at the same time between June 2012 and November 2014 in the First People's Hospital of Chengdu for comparison. ResultsThe quality score of SSD-CTA reconstructed image was lower than that of VCTDSA, but the diagnosis of the two technologies for intracranial aneurysm was not statistically different (P>0.05). Compared with DSA, the sensitivity and specificity of the diagnosis for intracranial aneurysms by SSD-CTA were both 100%. ConclusionSSD-CTA is valuable in diagnosing intracranial aneurysms.

    Release date: Export PDF Favorites Scan
  • Ultrasonographic characteristics of renal artery involvement in acute Stanford type A aortic dissection and its relationship with renal function: A retrospective cohort study

    Objective To investigate the ultrasonographic characteristics of acute Stanford type A aortic dissection (ATAAD) involving the renal arteries and their relationship with renal function. Methods Patients with ATAAD admitted to Deyang People's Hospital from February 2013 to May 2023 were selected for the study. Based on whether the renal arteries were involved in the dissection, the patients were divided into two groups: a renal artery involvement group and a renal artery non-involvement group. General data and ultrasound characteristics of the two groups were compared. Logistic regression analysis and model correction were performed to analyze the relationship between ultrasound characteristics and renal function involvement in ATAAD patients. Receiver operating characteristic (ROC) curves were used to evaluate the predictive value of ultrasound characteristics for renal artery involvement in ATAAD patients. Additionally, patients in the renal artery involvement group were divided into normal renal function and abnormal renal function subgroups based on serum blood urea nitrogen (BUN) and serum creatinine (Scr) levels. Clinical data of the two subgroups were compared, and a log-binomial model was used to analyze the risk effects of ultrasound characteristics for abnormal renal function. Pearson correlation analysis was performed to assess the correlation between ultrasound characteristics of renal artery involvement and renal function indicators. Results A total of 163 patients were included, consisting of 106 males and 57 females, with a mean age of (50.06±10.46) years (ranging from 20 to 85 years). Significant differences in gender, Scr, and BUN were observed between the renal artery involvement group and the renal artery non-involvement group (P<0.001). Compared to the renal artery non-involvement group, the renal artery involvement group had an increased ascending aorta diameter, a greater proportion of ascending aortic dilation and poor renal perfusion (P<0.05). Logistic regression analysis indicated that ascending aorta diameter, ascending aortic dilation, and poor renal perfusion were independent factors for renal artery involvement (P<0.05). Ultrasonographic characteristics showed good predictive ability for renal artery involvement in ATAAD patients. Furthermore, the combination of the three characteristics yielded a higher predictive value for renal artery involvement. Compared to the normal renal function group, the abnormal renal function group had higher BUN and Scr levels, increased ascending aortic diameter, a greater proportion of ascending aortic dilation and poor renal perfusion (P<0.05). The log-binomial model analysis revealed that the risk ratios for ascending aortic diameter, ascending aortic dilation, and poor renal perfusion were statistically significant both before and after adjustment (P<0.05). Pearson correlation analysis revealed that ascending aortic diameter, ascending aortic dilation, and poor renal perfusion were strongly correlated with renal function parameters (P<0.05). ConclusionUltrasound characteristics of ATAAD involving the renal arteries are associated with renal function. Ascending aorta diameter, ascending aortic dilation, and poor renal perfusion are independent risk factors for abnormal renal function.

    Release date:2025-04-02 10:54 Export PDF Favorites Scan
  • Evaluation of Peripancreatic Vascular Invasion of Pancreatic Carcinoma by Multi-Slice CT Angiography

    ObjectiveTo explore the value of multi-slice CT angiography (MSCTA) in peripancreatic vascular invasion of pancreatic carcinoma. MethodsThirty-eight patients with pancreatic carcinoma were detected by MSCTA technology before operation. The peripancreatic vascular invasion of pancreatic carcinoma was evaluated by multi-planar reconstruction (MPR) and maximum intensity projection (MIP) combined with axial image, and compared with the surgical results. ResultsThe MSCTA results showed that there were 12 patients (31.6%) with vascular invasion in 38 patients with pancreatic carcinoma, and the surgical results showed that there were 16 patients (42.1%) with vascular invasion. There was a b fit goodness of two results (kappa=0.665, P=0.000). The sensibility and specificity of MSCTA was 68.8% (11/16) and 95.5% (21/22), respectively. ConclusionsMSCTA technology has a high correct rate in evaluation of peripancreatic vessel encroached by pancreatic carcinoma, the MSCTA result has a b consistency to the surgical result. It has a value of clinical application in evaluation of peripancreatic vessel encroached by pancreatic carcinoma.

    Release date:2016-09-08 10:45 Export PDF Favorites Scan
  • THREE DIMENSIONAL VISUAL RESEARCH OF THORACIC DORSAL ARTERY BASED ON CT ANGIOGRAPHY

    ObjectiveTo study the digital anatomy and application value of the thoracic dorsal artery based on CT angiography (CTA). MethodsBetween September 2012 and June 2014, aorta CTA images were chosen from 10 cases (20 sides) undergoing aorta CTA. By using Mimics 17.0 software for three dimensional (3D) reconstruction of image post-processing, the digital vascular anatomical information were obtained after observing and measuring the origin of the thoracic dorsal artery, the number of perforators, type, inner diameter, and pedicle length; and the body surface location of perforator vessel was determined, and then the thoracic dorsal artery perforators tissue flap harvesting was simulated. Results3D reconstruction images showed that the thoracic dorsal artery originated from subscapular artery, 76 perforator vessels were found, including 32 perforators (42.1%) from the medial branch of the thoracic dorsal artery and 44 perforators (57.9%) from the lateral branch of the thoracic dorsal artery, of which 69 were intramuscular perforators (90.8%) and 7 were direct skin artery (9.2%). The inner diameter of the thoracic dorsal artery was (1.69±0.23) mm, and its pedicle length was (2.12±0.64) cm. The first lateral perforator of the thoracic dorsal artery located at (1.65±0.42) cm above the horizontal line of the inferior angle of scapula and at (1.68±0.31) cm lateral to vertical line of the inferior angle of scapula. The first medial perforator located at (1.43 ±0.28) cm above the horizontal line of the inferior angle of scapula and at (1.41±0.28) cm lateral to vertical line of the inferior angle of scapula. The thoracic dorsal artery perforators flap harvesting was successfully simulated. ConclusionCTA is a more intuitive method to study the thoracic dorsal artery in vivo, it can clearly display 3D information of the main blood supply artery course and distribution after flap reconstruction, so it can effectively and accurately guide the design of the flap.

    Release date: Export PDF Favorites Scan
  • Percutaneous left ventricular transapical access guided by cardiac 3D CT angiography combined with echocardiography

    ObjectiveTo investigate the reliability and safety of the technique of percutaneous left ventricular transapical access guided by cardiac three dimensional CT angiography (3D-CTA) combined with echocardiography applied in structural heart defects.MethodsThe clinical data of 9 patients (7 males and 2 females with a median age of 50 years ranging from 43 to 64 years) with paravalvular leaks closed by percutaneous left ventricular transapical access in West China Hospital, from April 2015 to August 2018, were retrospectively analyzed. We applied preoperative cardiac 3D-CTA to define the puncture site and trace, which was established by combining with real-time guidance of transesophageal echocardiography (TEE/3D-TEE), and an occluder was deployed at the apical access point for hemostasis with real-time guidance of transthoracic echocardiography (TTE).ResultsThe puncture needles were successfully introduced into the left ventricular cavity at one time in all patients without injury of lung tissue, coronary artery or papillary muscle. There was no occluder displacement or apex bleeding. One patient developed pleural effusion caused by intercostal artery injury.ConclusionThat cardiac 3D-CTA is used to define puncture sites and trace with advantages of simplicity and repeatability. A safe access and secure exit of left ventricle can be achieved by combining with real-time guidance of echocardiography. There are acceptable technology-related complications.

    Release date:2019-06-18 10:20 Export PDF Favorites Scan
  • Effectiveness of pulmonary artery CT angiography and pulmonary embolism findings based on artificial intelligence

    Objective To explore the application value of artificial intelligence (AI) pulmonary artery assisted diagnosis software for suspected pulmonary embolism patients. Methods The data of 199 patients who were clinically suspected of pulmonary embolism and underwent pulmonary artery CT angiography (CTA) from June 2016 to December 2021 were retrospectively analyzed. Images of pulmonary artery CTA diagnosed by radiologists with different experiences and judged by senior radiologists were compared with the analysis results of AI assisted diagnostic software for pulmonary artery CTA, to evaluate the diagnostic efficacy of this software and low, medium, and senior radiologists for pulmonary embolism. The agreement of pulmonary embolism based on pulmonary artery CTA between the AI software and radiologists with different experiences was evaluated using Kappa test. Results The agreement of the AI software and the evaluation of pulmonary embolism lesions by senior radiologists based on pulmonary artery CTA was high (Kappa=0.913, P<0.001), while the diagnostic results of pulmonary artery CTA AI software was good after judged by senior radiologists based on pulmonary artery CTA (Kappa=0.755, P<0.001). Conclusions The AI software based on pulmonary artery CTA diagnosis of pulmonary embolism has good consistency with diagnostic images of radilogists, and can save a lot of reconstruction and diagnostic time. It has the value of daily diagnosis work and worthy of clinical promotion.

    Release date:2024-02-22 03:22 Export PDF Favorites Scan
  • LENGTHENED PEDICLE OF RECTUS ABDOMINIS FLAP TO REPAIR DEFECT ON NECK AND CHEST

    ObjectiveTo explore the feasibil ity to repair defect on the neck and chest with the rectus abdominis flap which pedicle is lengthened by measuring the width, thickness, and the intercostal space of the inferior costicartilage using CT angiography (CTA). MethodsThirty cases receiving CTA and three-dimensional reconstruction between July and December 2013 were included in the study. Of 30 cases, 17 were male and 13 were female, aged 44-70 years (mean, 56 years). The width and thickness of the 3rd to 7th costicartilages and the distance of the 3rd to 6th intercostal spaces were measured, and the lengthened pedicle was calculated after the 4th to 7th costicartilage was cut off. Between July 2012 and November 2013, the lengthened pedicle of the rectus abdominis flap was cl inically used to repair the defect on the neck and chest in 4 cases. ResultsThe pedicle of the rectus abdominis flap was about 6 cm in length. When the left 7th, 6th, 5th, and 4th costicartilages were cut off, the average pedicle was lengthened by 4.07, 7.99, 12.50, and 17.48 cm respectively; when the right 7th, 6th, 5th, and 4th costicartilages were cut off, the average pedicle was lengthened by 4.63, 10.82, 16.64, and 22.05 cm respectively. In 4 flaps which were cl inically used to repair defects, 3 flap completely survived, 1 flap had partial necrosis. Three patients were followed up 6 months, and the appearance and texture of the flap were satisfactory; 1 patient failed to be followed up. ConclusionResecting the inferior costicartilage can prolong the pedicle of the rectus abdominis flap, therefore it can be used to repair defect on the upper chest and the neck.

    Release date: Export PDF Favorites Scan
  • APPLICATION OF DIGITAL TECHNOLOGY IN ANTEROLATERAL THIGH FLAP FOR REPAIRING WOUNDS OF HAND AND FOOT

    ObjectiveTo investigate the effectiveness of digital technology in repairing wounds of the hand and foot with anterolateral thigh flap. MethodsBetween September 2013 and September 2014, 16 cases of wounds of the hand and foot were treated with the anterolateral thigh flap. There were 10 males and 6 females, with an average age of 31 years (range, 20-52 years). The causes included traffic accident injury in 8 cases, crushing injury by machine in 6 cases, burning injury in 1 case, and animal biting injury in 1 case. The locations of soft tissue defect were the dorsum of the foot in 5 cases, the ankle in 4 cases, the planta pedis in 1 case, and the hand and forearm in 6 cases. The time was 2 hours to 45 days from injury to hospitalization (mean, 14.3 days). All defects were associated with exposure of bone and tendon. The size of wound was from 9.0 cm×4.0 cm to 29.0 cm×8.5 cm. CT angiography (CTA) was performed before operation, and the appropriate perforator as well as the donor site was selected. Then the Mimics15.0 software was used to reconstruct the data of CTA so as to locate the main perforators, design the three-dimensional models of the anterolateral thigh flap, and simulate operation. The flap was obtained according to preoperative plan during operation. The size of flaps varied from 11 cm×5 cm to 31 cm×10 cm. The donor sites were sutured directly in 14 cases and were repaired by free skin graft in 2 cases. ResultsThe lateral femoral circumflex artery identified by Mimics15.0 software before operation, as well as the starting position of its descending branch, the blood vessel diameter at start site, vascular distribution, the maximum cutting length of the vascular pedicle were consistent with the actual observation during operation. All flaps were harvested and were used to repair defect smoothly. Vascular crisis occurred in 1 flap after operation, and the other flaps survived successfully. The wounds and the incisions obtained healing by first intention, and grafted skin survived completely. All cases were followed up 6-17 months (mean, 9 months). Fifteen flaps had good shape;but a second-stage operation was performed to make the flap thinner in 1 case. At last follow-up, the results were excellent in 3 cases, good in 2 cases, and fair in 1 case according to total active motion (TAM) in 6 cases of hand and forearm injury;the results were excellent in 5 cases, good in 3 cases, and fair in 2 cases according to American Orthopaedic Foot and Ankle Society (AOFAS) in 10 cases of foot injury. The total excellent and good rate was 81.25%. ConclusionThe preoperative individualization design of the flap can be realized through CTA digital technology and Mimics15.0 software;it can reduce the operation risk.

    Release date: Export PDF Favorites Scan
  • The Effect of Snapshot Freeze on Improving Image Quality of Coronary CT Angiography in Patients with High Heart Rate

    ObjectiveTo explore the effect of snapshot freeze (SSF) on the image quality of coronary artery in 64 multislice spiral CT for patients with high heart rate. MethodsWe retrospectively analyzed the clinical data of 98 patients with an mean heart rate of ≥ 70 beats/min who underwent coronary CT angiography examination between August 2013 and February 2014. According to the inclusion criteria, 60 patients were included in our study. The image quality of standard reconstruction (STD) and motion-corrected (MC) reconstruction based on SSF platform were analyzed. The image quality was classified into 4 grades, and the image quality of coronary segments named according to AHA standard was evaluated. Then, we compared the image quality between the two different reconstruction methods. ResultsAltogether 180 coronary arteries and 795 coronary segments were evaluated. Before MC reconstruction, there were 133 (73.89%) arteries and 287 (36.10%) segments had pseudomorph, while after MC reconstruction, those two numbers were 89 (49.44%) and 150 (18.87%) (P<0.05). The right coronary artery (RCA) had a higher rate of pseudomorph and a lower image quality score[91.67% (55/60), 3.32±0.40] than left anterior descending artery[60.00% (36/60), 3.69±0.42] and left circumflex artery[70.00% (42/60), 3.44±0.55], especially the S2[90.00% (54/60), 2.45±0.85]. Overall image quality was higher with the use of MC reconstruction on per-artery level (P<0.05) and most of the per-segment level (P<0.05) compared with STD, especially for RCA and its segments (P<0.05). ConclusionSSF improves image quality of coronary artery in patients with high heart rate, especially for RCA.

    Release date: Export PDF Favorites Scan
  • Clinical Application of Multi-Slice Spiral CT in Portal Vein Imaging

    Objective To study the clinical significance of multi-slice spiral CT in portal vein imaging. Methods One hundred and thirty seven cases underwent enhanced scan with GE Light SpeedQX/i4 CT scanner were collected, including 41 cases of liver cancer, 20 cases of hepatic cirrhosis, 21 cases of cavernous hemangioma of liver, 9 cases of hepatic abscess, 6 cases of carcinoma of gallbladder, 14 cases of cholangiocarcinoma, 16 cases of pancreatic carcinoma, and 5 cases in normal. The results of portal vein images were reconstructed with three-dimensional software and analyzed. Results In 109 cases, portal vein, cranial mesenteric vein, and splenic vein were demonstrated successfully in the stage of portal vein: volume rendering images were clear in 84 cases, and maximum intensity projection images and multiplanar reconstruction images were clear in 109 cases. Forty-five cases of portal hypertension, 18 cases of opened collateral circulation, 15 cases of portal vein tumor thrombus, 1 case of splenic vein tumor thrombus, and 6 cases of large cavernous hemangioma were demonstrated successfully. Conclusion The portal vein imaging with multi-slice spiral CT can show the dissection and lesions of portal vein and its branches clearly, and can provide the clinical evidence for clinicians to formulate a treatment plan correctly.

    Release date:2016-09-08 10:49 Export PDF Favorites Scan
2 pages Previous 1 2 Next