Objective To evaluate the fixation technique of using the cervical lateral mass plate in the cervical posterior approach operation. Methods Eight patients in this group were admitted from September 2001 to November 2006. Among the 8 patients, there were 6 males and 2 females, with their ages ranging from 28 to 78 years. Cervical vertebral fracture with dislocation was found in 4 patients, C2 spinal cord injury in 1, C1 fracture in 1, cervical spinal stenosis in 1, and C2-5 spinal cord neurofibroma in 1. Muscle strength 3-4. TheFrankel grading system was usedin 6 patients with traumatic injury. Before operation, Grade C was observed in 2patients,Grade D in 3,and Grade E in 1. All the operations were performed according to requirements of the Margel’s method. We positioned 40 screws in all the patients, including 4 screws at C2,6 screws at C3,12 screws at C4,4 screws at C5,4 screws at C6,2 screws at C7,and 6 screws at T1. Results The followingup for an average of 14.1 months (range,645 months) revealed that there was no malposition of the screws in the patients. One of the 8 patients developed spinal instability in the fixed segment at 3 months after operation. The headchestbrace was applied to the patient for 3 months, and the spinal fusion was achieved. The further followingup to 45 months indicated that there was no instability occurring. The remaining patients recovered to their spinal stability by the spinal fusion. The patients also recovered in their neurological function after operation. The Frankel assessment showed that 1 patient had Grade E, 3 from Grade D to Grade E, 1 from Grade C to Grade D, and 1 from Grade C to Grade E. Conclusion The cervical lateral mass plate fixation can provide the immediate and b segmental immobilization for the good cervical spine stability.
Objective To study the cl inical appl ication of Mobi-C prosthesis in treatment of anterior cervical discectomy and artificial disc replacement (ADR). Methods Between January 2009 and June 2009, 20 cases of degenerative cervical disease were treated with anterior discectomy and ADR by Mobi-C prosthesis, including 13 cases of cervical disc herniation and 7 cases of cervical spondylotic radiculopathy, and 25 Mobi-C prosthesis were implanted. There were 8 males and 12 females, aged 29-54 years (mean, 45.2 years). The disease duration was from 4 days to 5 years (mean, 1.2 years). Affected segments of process included C3, 4 in 1 case, C4, 5 in 2 cases, C5, 6 in 7 cases, C6, 7 in 5 cases, C4, 5 and C5, 6 in 2 cases, and C5, 6 and C6, 7 in 3 cases. Radiographs were taken regularly, and cervical range of motion (ROM) on segments of disc replacements were measured. The functions of cervical spinal cord were evaluated by “40 score” system (COA) preoperatively, immediately postoperatively, and at follow-up. The qual ity of l ife was evaluated by neck disabil ity index (NDI) and visual analogue scale (VAS) score. Results All incisions healed by first intention. No perioperative compl ication was found. All cases were followed up 16.5 months on average (range, 14-18 months). There was no significant difference in cervical ROM of operatied segment between preoperation and follow-up duration (t=0.808,P=0.440). No heterotopic ossification was found at follow-up. COA score at last follow-up (38.20 ± 1.14) was significantly higher than preoperative one (32.10 ± 2.96) , (t=9.278,P=0.000) , and the improvement rate at last follow-up was 77.2% ± 5.4%. VAS score at last follow-up (3.20 ± 1.23) had significant difference when compared with preoperative one (5.10 ± 1.29), (t=10.585,P=0.000). NDI score at last follow-up (29.40 ± 4.55) had significant difference when compared with preoperative one (39.20 ± 3.80), (t=16.039, P=0.000). Conclusion A satisfactory short-term curative effect can be obtained by using Mobi-C prosthesis in treatment of anterior cervical discectomy and ADR.
Objective To summarize the methods andskills of anterior cervical locking plate systems in clinical application and to analyze the causes of some complications as well as give some preventive or remedial countermeasures. Methods From 1998 to 2002, 159 patients with cervical spondylotic myelopathy,fracturedislocation,tumor or tuberculosis of the cervical spine were treated with anterior locking plate systems. The complications were reviewed and analyzed. Results Ten kinds of complications related to anterior locking plate systems occurred in 21 patients. Most of the complications were caused by improperly-selecting implants, experience and technique deficiency. Conclusio The important preventive or remedial countermeasures are correctly-selecting patients, meticulous preoperative preparation, properly-selecting implants, standard and skillful manipulation and rational postoperative protection.
ObjectiveTo evaluate the mid-term clinical and radiological results of dynamic cervical implant (DCI) arthroplasty for degenerative cervical disc disease in Chinese population.MethodsBetween April 2010 and June 2011, 25 patients with single-segmental degenerative cervical disc disease underwent DCI replacement. Visual Analogue Scale (VAS), Japanese Orthopaedic Association (JOA) scores, Neck Disability Index (NDI) and 36-Item Short Form Health Survey Questionnaires (SF-36) were used for evaluation of neurological function and pain severity, before and after operation, and during follow-up period. Radiographic evaluation included range of motion (ROM) of C2–7, surgical segments and adjacent level, intervertebral height of the surgical segments, migration, subsidence of the implant and heterotopic ossification (HO).ResultsThe mean follow-up period was 72.3 months (ranged from 68 to 78 months). The VAS, JOA, NDI, and SF-36 mental and physical component summaries improved significantly after surgery (P<0.05) and remained stable over the whole observation period. The ROM (flexion/extension) and intervertebral height at the level treated with DCI remained at the first 2 years and partly reduced at the final follow-up. ROM for C2–7 and adjacent levels maintained during the follow-up period. DCI subsidence was observed in 11 segements, and 9 segements appeared heterotopic ossification.ConclusionsClinical efficacy of DCI arthroplasty improves and maintaines during the mid-to-long period of follow-up. HO formation is a common phenomenon, leading a dramatic decrease of ROM at index level and recurrence of neurological symptoms. Rate of implant subsidence and migration is relatively high, leaving a potential risk of symptom at index level and adjacent segment degeneration. It suggests that for patients with degenerative cervical disc disease, total disc replacement or anterior cervical discectomy and fusion is still the first choice instead of DCI arthroplasty.
Objective To evaluate the cl inical appl ication value and short-term results of Vertex rod-screw system in cervical expansive open-door laminoplasty. Methods Between February 2008 and January 2010, 28 patients underwent Vertex rod-screw system fixation in cervical expansive open-door laminoplasty, including 15 cases of cervical spondylotic myelopathy, 5 cases of ossification of posterior longitudinal l igament,and 8 cases of cervical spondylosis with spinal stenosis. There were 16 males and 12 females, aged 42-77 years (mean, 61.3 years). The disease duration was 2 months to 11 years. The decompression range of cervical spine was from C3 to C7. The operation time, blood loss, Japanese Orthopedic Association (JOA) scores, and incidence of axial symptom were recorded. Pre- and postoperative curvature angles were demonstrated by the cross angle between posterior vertebral body margins of C2 and C7 on cervical X-ray films. The angle of the opened laminae was measured on CT scan at last follow-up. Results The operation time was (142.5 ± 22.8) minutes, and the blood loss was (288.2 ± 55.1) mL. All incisions healed by first intention. All patients were followed up 14-25 months (mean, 22 months). CT showed that no reclosed open-laminae or loosening and breakage of rod-screw system occurred at 1 week and 1 year after operation. The axial bony fusion rate was 89.3% (25/28). The improvement rate of JOA scores at 1 week after operation (29.5% ± 15.0%) was significantly smaller than that at 1 year after operation (64.9% ± 28.1%) (t=0.810, P=0.000). No case presented with C5 nerve root palsy. The cervical curvature angle was (24.29 ± 5.04)° before operation, was (23.89 ± 3.57)° at 1 week, and was (23.41 ± 3.35)° at 1 year after operation, showing no significant difference between pre- and postoperative angles (P gt;0.05). The angle of the opened laminae was (27.90 ± 4.74)° at 1 week after operation, and was (28.07 ± 4.21)° at 1 year after operation, showing no significant difference (P gt; 0.05). Conclusion Vertex rod-screw system in cervical expansive opendoor laminoplasty is effective in preventing reclosed open-laminae, which can reduce the loss of cervical curvature angle.
ObjectiveTo evaluate the effectiveness of cervical disc replacement for cervical myelopathy. MethodsBetween October 2006 and October 2008, 20 patients (26 segments) with cervical myelopathy underwent single-level (14 segments) or bi-level (6 segments) cervical disc replacement. There were 8 males and 12 females with an average age of 46 years (range, 26-65 years). The disease duration ranged 2-18 months (mean, 7 months). The effectiveness was evaluated using visual analogue scale (VAS) score, cervical range of motion (ROM), and the Odom et al. criteria. Heterotopic ossification (HO), osteophyte formation, and prosthesis loosening were observed. ResultsAll incisions healed by first intention, with no severe complication. Twenty patients were followed up 30-48 months (mean, 34 months). At 28 months after operation, according to Odom et al. criteria, the results were excellent in 17 cases and good in 3 cases. The VAS scores of the neck, shoulder, and upper limb were significantly improved when compared with preoperative scores (P lt; 0.05). At 30 months after operation, X-ray films showed that 20 replaced segments were mobile and ROM was (10.6 ± 4.5)°, showing no significant difference (P gt; 0.05) when compared with that of upper adjacent segment (10.8 ± 3.7)° and lower adjacent segment (7.5 ± 4.2)°. HO occurred in 10 cases (13 segments). No displacement, subsidence, or loosening occurred except 1 case of retrodisplacement of the prosthesis. ConclusionCervical disc replacement can obtain good effectiveness. It can maintain normal cervical ROM and physiological curvature. But it needs further long-term follow-up to evaluate the function and the influence on the adjacent segments.
ObjectiveTo investigate the effect of prophylactic C4, 5 foraminal dilatation in posterior cervical open-door surgery on postoperative C5 nerve root palsy syndrome.MethodsThe clinical data of patients with cervical spondylotic myelopathy (cervical spinal cord compression segments were more than 3) who met the selection criteria between March 2016 and March 2019 were retrospectively analyzed. Among them, 40 patients underwent prophylactic C4, 5 foraminal dilatation in posterior cervical open-door surgery (observation group) and 40 patients underwent simple posterior cervical open-door surgery (control group). There was no significant difference between the two groups (P>0.05) in gender, age, disease duration, Nurick grade of spinal cord symptoms, and preoperative diameter of C4, 5 intervertebral foramen, Japanese Orthopaedic Association (JOA) score, and visual analogue scale (VAS) score. The occurrence of C5 nerve root paralysis syndrome was recorded and compared between the two groups, including incidence, paralysis time, recovery time, and spinal cord drift. VAS and JOA scores were used to evaluate the improvement of pain and function before operation and at 12 months after operation.ResultsThe incisions of the two groups healed by first intention, and there was no early postoperative complications such as cerebrospinal fluid leakage. Patients of both groups were followed up 12-23 months, with an average of 17.97 months. C5 nerve root paralysis syndrome occurred in 8 cases in the observation group (3 cases on the right and 5 cases on the left) and 2 cases in the control group (both on the right). There was significant difference of the incidence (20% vs. 5%) between the two groups (χ2=4.114, P=0.043). Except for 1 case in the observation group who developed C5 nerve root palsy syndrome at 5 days after operation, the rest patients all developed at 1 day after operation; the recovery time of the observation group and the control group were (3.87±2.85) months and (2.50±0.70) months respectively, showing no significant difference between the two groups (t=–0.649, P=0.104). At 12 months after operation, the JOA score and VAS score of cervical spine in the two groups significantly improved when compared with those before operation (P<0.05); there was no significant difference in the difference of the cervical spine JOA score and VAS score between at 12 months after operation and before operation and the degree of spinal cord drift between the two groups (P>0.05).ConclusionProphylactic C4, 5 foraminal dilatation can not effectively prevent and reduce the occurrence of postoperative C5 root palsy, on the contrary, it may increase its incidence, so the clinical application of this procedure requires caution.
Objective To investigate the feasibil ity, safety and operative techniques of percutaneous vertebroplasty (PVP) in treating osteolytic bone metastasis of cervical vertebra and reconstructing the function of cervical vertebra. Methods From March 2005 to December 2007, 10 patients with osteolytic bone metastatic carcinoma in single cervical vertebral body received PVP, including 5 males and 5 females aged 38-75 years (mean 54.5 years). Among them, 5 patients had primary lung tumor, 1 primary renal tumor, 1 primary breast tumor, 1 primary cervical tumor and 2 unknown primary lesion. The course of disease was 2-4 years. All the patients suffered from obviously cervical pain and l imitation of activity, including 4 cases of metastatic tumor of the C2 vertebral body, 2 of C3, 2 of C6 and 2 of C7. The general condition of patients was stable before operation, and no blood coagulation dysfunction, radiculalgia and spinal cord compression were detected. Lateral PVP was performed on 6 cases, approaching between the vertebral artery and the carotid sheath under CT guidance and anterolateral PVP was performed on the rest 4 cases, approaching between the trachea and the internal carotid artery under continuously X-ray fluoroscopy. The amount of bone cement injected was 3-4 mL, and the fill ing rate was 50%-100%. Results Without obvious bleeding or organ injury, the puncture was performed successfully on all the patients. Without symptom of spinal cord compression, patients suffered from pain during operation (1 case) and such compl ications noted by immediate CT or X-rays examination after operation as paravertebral epidural cement leakage (2 ases),transverse foramen cement leakage (1 case) and pinhole reflux (3 cases). The pain of patients was improved to various degree postoperatively, the visual analogue scales score was (5.9 ± 1.2) points before operation, which was changed to (2.6 ± 1.2) points at 1 hour after PVP and (1.6 ± 1.3) points at 1 week after PVP, indicating there was a significant difference between pre- and postoperation (P lt; 0.05). During the regular follow-up at 1 week, 3 and 12 months after PVP, all patients had no dislocation of cervical vertebra body, spinal cord compression and paralysis. Five patients died from multiple organ failure due to primary tumor progression, including 3 cases at 6 months after PVP and 2 at 12 months after PVP, and the rest 5 patients’ cervical pain were under control, with sound functional recovery. Conclusion PVP can rel ieve pain quickly and reinforce the stabil ity of the vertebral body, and has sl ight compl ications; the lateral approach is safe and effective.
Objective To explore the feasibilities, methods, outcomes and indications of atlas pedicle screw system fixation and fusion for the treatment of upper cervical diseases. Methods From October 2004 to January 2006, 17 patients with upper cervical diseases were treated with atlas pedicle screw system fixation and fusion. There were 13 males and 4 females, ageing 19 to 52 years. Of 17 cases, there were 14 cases of atlantoaxial dislocation(including 3 cases of congenital odontoid disconnection,4 cases of old odontoid fracture,2 cases of new odontoid fracture(typeⅡC), 3 cases of rupture of the transverse ligament, and 2 cases of atlas fracture; 2 cases of tumor of C2; 1case of giant neurilemoma of C2,3 with instability after the resection oftumors. JOA score before operation was 8.3±3.0. Results The mean operative time and bleeding amount were 2.7 hours (2.1-3.4 hours) and 490 ml (300-750 ml) respectively. No injuries to the vertebral artery and spinal cord were observed. The medial-superior cortex of lateral mass was penetrated by 1 C1 screw approximately 3 mmwithout affecting occipito-atlantal motions. All patients were followed up 3-18 months. The clinical symptoms were improved in some extents and the screws were verified to be in a proper position, no breakage or loosening of screw and rob occurred. All patients achieved a solid bone fusion after 3-6 months. JOA score 3 months after operation was14.6±2.2. JOA improvement rates were 73%-91%(mean 82%). Conclusion The atlas pedicle screw system fixation and fusion is feasible for the treatment of upper cervical diseases and has betteroutcomes, wider indications if conducted properly.
ObjectiveTo systematically review the correlation between Beclin1 protein expression and cervical cancer as well as its different clinical pathologic features. MethodsWe electronically searched databases including The Cochrane Library (Issue 1, 2014), PubMed, EMbase, Ovid, CNKI, VIP, CBM and WanFang Data from inception to February 2014, to collect the correlation between Beclin1 protein expression and cervical cancer as well as its different clinical pathologic features. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data, and assessed the methodological quality of the included studies. Then meta-analysis was conducted using RevMan 5.2 software. ResultsA total of 5 case-control studies involving 637 patients were included, of which, 388 cases in the cervical cancer group, 130 cases in the cervical intraepithelial neoplasia (CIN) group, and 119 cases in the normal cervical tissue group. The results of meta-analysis showed that, a) as for Beclin1 expression, significant differences were found in cervical cancer vs. normal cervical tissues (OR=0.07, 95%CI 0.02 to 0.25, P < 0.000 1), cervical cancer vs. CIN (OR=0.37, 95%CI 0.23 to 0.59, P < 0.000 1), CIN vs. normal cervical tissues (OR=0.23, 95%CI 0.06 to 0.88, P=0.03), and cervical cancer tissues with vs. without lymph node metastasis (OR=0.29, 95%CI 0.17 to 0.49, P < 0.000 01). However, no significant difference was found in medium/low differentiation vs. well differentiation (OR=0.50, 95%CI 0.16 to 1.56, P=0.23), tumour diameter no less than vs. less than 4 cm (OR=0.72, 95%CI 0.44 to 1.18, P=0.20), myometrial invasion depth no less than vs. less than 1/2, and FIGO Ⅰ vs. Ⅱ (OR=0.70, 95%CI 0.44 to 1.10, P=0.12). ConclusionBeclin1 protein expression is notably associated to cervical cancer. Due to the limited quantity and quality of the included studies, the above conclusion still needs to be further verified by performing more high quality studies.