west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Digital" 55 results
  • APPLICATION OF V-Y ADVANCEMENT FLAP PEDICLED WITH DORSAL CUTANEOUS BRANCH OF DIGITAL ARTERY FOR SKIN DEFECT AT THE SAME DORSAL FINGER

    Objective To investigate the therapeutic effect of V-Y advancement flap pedicled with dorsal cutaneous branch of digital artery for skin defect at the same dorsal finger. Methods Between January 2008 and February 2010, 15 cases of skin defect at the same dorsal finger were treated. There were 9 males and 6 females, aged 15-72 years (mean, 43 years). Defect was caused by saw machine in 6 cases, machines crush in 7 cases, and cutting nodule in 2 cases. The locationswere distal dorsal finger in 2 cases, middle dorsal finger in 6 cases, and proximal dorsal finger in 7 cases. All cases compl icated by exposure of tendon and bone. The size of defect ranged from 0.8 cm × 0.5 cm to 1.4 cm × 1.0 cm. The interval between injury and operation was 3-8 hours. All fingers were treated by V-Y advancement flap from the dorsal cutaneous branch of digital artery, which size was 1.2 cm × 0.8 cm-2.5 cm × 1.0 cm, and the donor site was directly sutured. Fracture reductionand Kirschner wire for internal fixation were performed in the patients with fracture; extensor tendon was repaired with 4-0 thread in the patients with tendon injury. Results All flaps survived completely. The incisions of donor and recipient sites healed by first intention. Ten cases were followed up 6 months to 2 years after operation. The flaps had good texture, color, and appearance; 2-point discrimination of the V-Y flap was 10-12 mm. X-ray examination showed that all finger fractures healedsuccessfully in 5 cases, with an average bone union time of 6 weeks (range, 5-8 weeks). According to the criteria for function assessment by total active motion, the results were excellent in 8 cases, good in 1, and fair in 1 with an excellent and good rate of 90%. Conclusion It is an ideal method to treat skin defect at the same dorsal finger with V-Y advancement flap pedicled with dorsal cutaneous branch of digital artery.

    Release date:2016-08-31 05:41 Export PDF Favorites Scan
  • CLINICAL APPLICATION OF VASCULARIZED SKIN FLAP WITH NERVE (REPORT OF 10 CASES)

    The digital defects which severely interfered with the hand functions must be reconstructed. The primary repair by vascularized skin flap with the dorsal branch of proper palmar digital nerve could be done. The vascularized flap was rich in blood circulation, perfect sensibility and a good contour, as well as preserving donor digital sensation. However, it was simple, safe, and with higher success. From 1989 to 1991, 10 cases of digital defects were treated, all of the patients gained very good results. The indication and technique of thismethod wasdiscussed in detail.

    Release date:2016-09-01 11:38 Export PDF Favorites Scan
  • EFFECTIVENESS OF DIGITAL CUSTOMIZED STEEL PLATE IN TREATMENT OF COMPLEX FRACTURES OF LIMBS

    ObjectiveTo observe the effectiveness of digital customized plate in the treatment of complex limb fracture. MethodsBetween January 2012 and May 2013, CT raw data of complex limb fracture were used to establish the fracture three-dimensional simulation model after reduction, and a customized personalized anatomic plate was designed and used for internal fixation after open reduction in 42 cases. There were 22 males and 20 females, aged 16-53 years (average, 37.4 years). The causes of injury were traffic accident in 21 cases, falling from height in 18 cases, crush by heavy objects in 3 cases, including 26 cases of fresh closed fracture and 16 cases of open fracture (9 cases of type Ⅰ and 7 cases of type Ⅱ according to Gustilo classification). According to AO classification, there were 15 cases of humerus comminuted fracture, 4 cases of radial comminuted fracture, 8 cases of femoral comminuted fracture, and 15 cases of tibia comminuted fracture. The interval of injury and operation was 6-28 days (mean, 10 days). ResultsReduction and internal fixation of fracture were successfully performed on 42 patients. The length and position of digital customized plate, direction and length of screw implant, number of screw were basically identical with preoperative design. The operation time was 35-120 minutes (mean, 70 minutes); the blood loss volume was 30-500 mL (mean, 180 mL); and X ray fluoroscopy frequency was 2-6 times (mean, 3 times). Superficial infection occurred in 2 cases, and was cured after dressing change; primary healing of incision was obtained in the other patients. Forty-two cases were followed up 6-24 months with an average of 11.5 months. The fracture healing time was 8-19 weeks (mean, 14 weeks) in 41 cases; delayed union occurred in 1 case at 44 weeks after operation. The fracture anatomical reduction was achieved in 19 cases, malunion in 3 cases, and functional reduction in the other patients. At last follow-up, no plate and screw loosening and breakage was observed. ConclusionDigital customized plate in treatment of complex fractures of limbs, especially for the multiple comminuted fracture of long bones of the limbs has the advantages of convenient operation, less trauma, fewer complications, and good effectiveness.

    Release date: Export PDF Favorites Scan
  • BASIC CONCEPT IN COMPUTER ASSISTED SURGERY

    Objective To investigate application of medical digital imaging systems and computer technologies in orthpedics. Methods The main computer-assisted surgery systems comprise the four following subcategories. Results ①A collection and recording process for digital data on each patient, including preoperative images (CT scans, MRI, standard X-rays), intraoperative visualization (fluoroscopy, ultrasound), and intraoperative position and orientation of surgical instruments or bone sections (using 3D localisers). Data merging based on the matching of preoperative imaging (CT scans, MRI, standard X-rays) and intraoperative visualization (anatomical landmarks, or bone surfaces digitized intraoperatively via 3D localiser; intraoperative ultrasound images processed for delineationof bone contours). ②In cases where only intraoperative images are used for computer-assisted surgical navigation, the calibration of the intraoperative imaging system replaces the merged data system, which is then no longer necessary. ③A system that provides aid in decisionmaking, so that the surgical approach is planned on basis of multimodal information: the interactive positioning of surgical instruments or bone sections transmitted via pre- or intraoperative images, display of elements to guide surgicalnavigation (direction, axis, orientation, length and diameter of a surgical instrument, impingement, etc.). And ④ A system that monitors the surgical procedure, thereby ensuring that the optimal strategy defined at the preoperative stage is taken into account. Conclusion It is possible that computer-assisted orthopedic surgery systems will enable surgeons to better assess the accuracy and reliability of the various operative techniques, an indispensable stage in the optimization of surgery.

    Release date:2016-09-01 09:25 Export PDF Favorites Scan
  • Application progress and thinking of digital therapeutics in orthopedics

    In recent years, the rapid development of information and communication technology, big data, and artificial intelligence has provided technical support for exploring new medical methods, leading to the emergence of digital therapeutics (DTx). At present, the application of DTx in orthopedics is still in the preliminary exploration stage. Therefore, based on the authors’ experience of applying DTx, this article summarizes the definition and formation process of DTx, as well as the relationship among digital health, digital medicine, and DTx, evaluates the working principles and application effects of existing orthopedic related DTx products, analyzes their shortcomings in the application process, and looks forward to their future development trends, aiming to lay a foundation for the comprehensive development and application of DTx in orthopedics.

    Release date:2024-11-27 02:31 Export PDF Favorites Scan
  • Digital drainage system versus traditional drainage system for thoracic drainage after lung surgery: A case control study

    Objective To compare the digital drainage system and the traditional drainage system in the patients after lung surgery, and to evaluate the advantages of digital drainage system. Methods A retrospective analysis of consecutive 42 patients with lung surgery between September 2016 and May 2017 in Beijing University International Hospital was done. There were 30 males and 12 females with a median age of 34 years ranging 19-81 years. After the surgery 21 patients adopted Thopaz digital drainage device (a DDS group), and the other 21 patients adopted traditional drainage (a TDS group). Duration of air leakage and chest tube placement, length of hospital stay, thoracic drainage volume within 48 h and hospitalization expenses in the two groups were compared. Results The patients in the two groups were all successfully discharged. Compared with the TDS group, duration of air leakage and chest tube placement and length of hospital stay significantly shortened in the DDS group (35.6±16.3 h vs. 48.2±20.1 h, P=0.02; 50.0±16.1 h vs. 62.0±20.4 h, P=0.03; 5.9±2.3 d vs. 7.8±3.5 d, P=0.02), and thoracic drainage volume within 48 h and hospitalization expenses showed no significant statistical difference between the two groups. Conclusion Using digital drainage system after lung surgery can significantly shorten the duration of air leakage and the postoperative drainage, at the same time, without increasing the overall hospitalization expenses.

    Release date:2018-03-28 03:22 Export PDF Favorites Scan
  • V-Y ADVANCEMENT OF VOLAR SKIN FLAPS PEDICLED BY DIGITAL AR-TERIES AND NERVES FOR RECONSTRUCTION OF DIGITAL SKIN DEFECT

    The traditional Kutler and Atasoy V-Y advancement flaps have minimal advancement degree, did not satisfy to repair large skin defect in fingers, hence, have no wide indications. The sensory function of the fingers to be influenced because of injury of sensory nerves and sear formation. Since 1985 to 1991, the V-Y advancement flaps pedicled by bilateral digital arteries and nerves have been used for reconstruction of 33 finger tip defect and 5 digital volar skin contraction. All of these cases obtained satisfactory function and excellent appearance.In this paper, the anatomical charactistics and principles of devicerecommended, the advantages and key points to success discussed.

    Release date:2016-09-01 11:38 Export PDF Favorites Scan
  • TRANSPLANTATION OF THE PALMARIS LONGUS TENDON WITH A VASCULAR PEDICLE FOR THE COMPLEX INJURY OF THE DIGITAL FLEXOR TENDON

    In order to seek a good method to treat the severe, complex damage of the digital flexor tendon, an anatomical study based on 30 cadavers was done, and the result showed that the source of the blood supply to the palmaris longus tendon was from the radial and ulnar arteries. Three cases of severe complex digital flexor tendon injuries were satisfactory. Its main advantages were: (1) The tendon transplant had its own blood supply and had no need to the revascularization, therefore the adhesion formed between the tendon and adjacent tisues might be less;(2) Besides reparing the tendon defect, it can simultaneously solve the problem of the defect of the soft tissues and the skin.

    Release date:2016-09-01 11:33 Export PDF Favorites Scan
  • Control Study on the Value of Head Boneless CT Angiography for Surface Shaded Display and Volume Computed Tomographic Digital Subtraction Angiography in Diagnosing Intracranial Aneurysms

    ObjectiveTo investigate the value of head boneless CT angiography (CTA) for surface shaded display (SSD) (hereinafter referred to as the SSD-CTA technology) and volume computed tomographic digital subtraction angiography (VCTDSA) in diagnosing intracranial aneurysms. MethodsWe collected the clinical data of 35 patients diagnosed to have intracranial aneurysm by VCTDSA between April 2013 and November 2014 from the First Affiliated Hospital of Chongqing Medical University. The original data were imported into the CT workstation of the First People's Hospital of Chengdu. Then, SSD-CTA technology was performed for bone reconstruction. We compared the results of these two technologies. In addition, we selected another 27 patients diagnosed with intracranial aneurysm by SSDCTA and DSA examination at the same time between June 2012 and November 2014 in the First People's Hospital of Chengdu for comparison. ResultsThe quality score of SSD-CTA reconstructed image was lower than that of VCTDSA, but the diagnosis of the two technologies for intracranial aneurysm was not statistically different (P>0.05). Compared with DSA, the sensitivity and specificity of the diagnosis for intracranial aneurysms by SSD-CTA were both 100%. ConclusionSSD-CTA is valuable in diagnosing intracranial aneurysms.

    Release date: Export PDF Favorites Scan
  • Clinical Application of Digital Gastrointestinal Machine and Modified Hypotonic DoubleContrast Barium Enema Technique

    ObjectiveTo improve the efficacy of colon doublecontrast barium enema examination by using digital gastrointestinal machine and modified enema techniques. MethodsSixtyfour patients were examined on digital remote controlled gyration table, with oral coloncleansing preparation and selfmade disposable plastic bag. Results In 64 patients, up to 93.8% were found with none or little fecal materials in the cecum and ascending colon. 80% of the results were scored excellent, and 95% were accurate for making diagnosis. All the patients underwent the examination successfully. ConclusionDigital gastrointestinal machine examination combined with modified hypotonic doublecontrast barium enema is a simple, convenient and efficient way to clearly demonstrate colonic mucosa, and help increase the detection and diagnosis rate.

    Release date:2016-08-28 04:43 Export PDF Favorites Scan
6 pages Previous 1 2 3 ... 6 Next

Format

Content