west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Digital" 55 results
  • Multidetector-Row CT Angiography and Digital Subtraction Angiography of Bronchial Artery in Diagnosis of Hemoptysis: A Comparative Study

    Objective To compare the bronchial arteriography through multidetector-row CT (MDCT) with the digital subtraction angiography (DSA) via femoral artery, and evaluate the application value of bronchial arteriography through MDCT in the diagnosis and treatment of hemoptysis. Methods 133 cases complained of hemoptysis were examined by MDCT and DSA via femoral artery respectively to perform bronchial arteriography, and the differences of image results by two methods were compared. Results 129 cases with abnormal bronchial arteries were confirmed by DSA via femoral artery, 117 cases were checked by MDCT [ the positive rate was 90.7% (117/129 ) ] . 117 cases with abnormal bronchial arteries were confirmed by both MDCT and DSA via femoral artery and 4 cases did not detected any abnormal arteries by both methods. The coincidence rate of two methods was 91.0% (121 /133) . MDCT and DSA via femoral artery showed the similar origins of abnormal bronchial arteries. The coincidence rate of two methods was 100% . Conclusions There is a high coincidence rate betweenMDCT and DSA in detecting bronchial artery abnormalities. MDCT shows the origins of abnormal vessels clearly which could be a fist-choice of routine imagination for interventive operation.

    Release date: Export PDF Favorites Scan
  • Modern transformation and development of traditional Chinese medicine instruments in the era of digital intelligence

    Traditional Chinese medicine equipment plays an indispensable role in the prevention, diagnosis, treatment and rehabilitation of traditional Chinese medicine from the needs of people's life and health, and provides technical support for the simple, convenient, cheap and effective clinical practice of traditional Chinese medicine. The traditional Chinese medicine equipment industry has the development advantages of large demand gap, strong policy support and emerging technology empowerment. At the same time, there are also bottlenecks such as lagging standardization construction, weak industrial foundation, insufficient characteristics of traditional Chinese medicine and immature evidence-based evaluation research. The coming of the era of digital intelligence has brought new opportunities for the development and reform of the traditional Chinese medicine equipment industry. This paper provides development ideas for the transformation of traditional Chinese medicine equipment from traditional to modern from the aspects of standardization construction, digital intelligence industry upgrading, improvement of evidence-based evaluation system and in-depth international exchanges and cooperation.

    Release date:2024-07-09 05:43 Export PDF Favorites Scan
  • BASIC CONCEPT IN COMPUTER ASSISTED SURGERY

    Objective To investigate application of medical digital imaging systems and computer technologies in orthpedics. Methods The main computer-assisted surgery systems comprise the four following subcategories. Results ①A collection and recording process for digital data on each patient, including preoperative images (CT scans, MRI, standard X-rays), intraoperative visualization (fluoroscopy, ultrasound), and intraoperative position and orientation of surgical instruments or bone sections (using 3D localisers). Data merging based on the matching of preoperative imaging (CT scans, MRI, standard X-rays) and intraoperative visualization (anatomical landmarks, or bone surfaces digitized intraoperatively via 3D localiser; intraoperative ultrasound images processed for delineationof bone contours). ②In cases where only intraoperative images are used for computer-assisted surgical navigation, the calibration of the intraoperative imaging system replaces the merged data system, which is then no longer necessary. ③A system that provides aid in decisionmaking, so that the surgical approach is planned on basis of multimodal information: the interactive positioning of surgical instruments or bone sections transmitted via pre- or intraoperative images, display of elements to guide surgicalnavigation (direction, axis, orientation, length and diameter of a surgical instrument, impingement, etc.). And ④ A system that monitors the surgical procedure, thereby ensuring that the optimal strategy defined at the preoperative stage is taken into account. Conclusion It is possible that computer-assisted orthopedic surgery systems will enable surgeons to better assess the accuracy and reliability of the various operative techniques, an indispensable stage in the optimization of surgery.

    Release date:2016-09-01 09:25 Export PDF Favorites Scan
  • APPLICATION OF V-Y ADVANCEMENT FLAP PEDICLED WITH DORSAL CUTANEOUS BRANCH OF DIGITAL ARTERY FOR SKIN DEFECT AT THE SAME DORSAL FINGER

    Objective To investigate the therapeutic effect of V-Y advancement flap pedicled with dorsal cutaneous branch of digital artery for skin defect at the same dorsal finger. Methods Between January 2008 and February 2010, 15 cases of skin defect at the same dorsal finger were treated. There were 9 males and 6 females, aged 15-72 years (mean, 43 years). Defect was caused by saw machine in 6 cases, machines crush in 7 cases, and cutting nodule in 2 cases. The locationswere distal dorsal finger in 2 cases, middle dorsal finger in 6 cases, and proximal dorsal finger in 7 cases. All cases compl icated by exposure of tendon and bone. The size of defect ranged from 0.8 cm × 0.5 cm to 1.4 cm × 1.0 cm. The interval between injury and operation was 3-8 hours. All fingers were treated by V-Y advancement flap from the dorsal cutaneous branch of digital artery, which size was 1.2 cm × 0.8 cm-2.5 cm × 1.0 cm, and the donor site was directly sutured. Fracture reductionand Kirschner wire for internal fixation were performed in the patients with fracture; extensor tendon was repaired with 4-0 thread in the patients with tendon injury. Results All flaps survived completely. The incisions of donor and recipient sites healed by first intention. Ten cases were followed up 6 months to 2 years after operation. The flaps had good texture, color, and appearance; 2-point discrimination of the V-Y flap was 10-12 mm. X-ray examination showed that all finger fractures healedsuccessfully in 5 cases, with an average bone union time of 6 weeks (range, 5-8 weeks). According to the criteria for function assessment by total active motion, the results were excellent in 8 cases, good in 1, and fair in 1 with an excellent and good rate of 90%. Conclusion It is an ideal method to treat skin defect at the same dorsal finger with V-Y advancement flap pedicled with dorsal cutaneous branch of digital artery.

    Release date:2016-08-31 05:41 Export PDF Favorites Scan
  • Digital drainage system versus traditional drainage system for thoracic drainage after lung surgery: A case control study

    Objective To compare the digital drainage system and the traditional drainage system in the patients after lung surgery, and to evaluate the advantages of digital drainage system. Methods A retrospective analysis of consecutive 42 patients with lung surgery between September 2016 and May 2017 in Beijing University International Hospital was done. There were 30 males and 12 females with a median age of 34 years ranging 19-81 years. After the surgery 21 patients adopted Thopaz digital drainage device (a DDS group), and the other 21 patients adopted traditional drainage (a TDS group). Duration of air leakage and chest tube placement, length of hospital stay, thoracic drainage volume within 48 h and hospitalization expenses in the two groups were compared. Results The patients in the two groups were all successfully discharged. Compared with the TDS group, duration of air leakage and chest tube placement and length of hospital stay significantly shortened in the DDS group (35.6±16.3 h vs. 48.2±20.1 h, P=0.02; 50.0±16.1 h vs. 62.0±20.4 h, P=0.03; 5.9±2.3 d vs. 7.8±3.5 d, P=0.02), and thoracic drainage volume within 48 h and hospitalization expenses showed no significant statistical difference between the two groups. Conclusion Using digital drainage system after lung surgery can significantly shorten the duration of air leakage and the postoperative drainage, at the same time, without increasing the overall hospitalization expenses.

    Release date:2018-03-28 03:22 Export PDF Favorites Scan
  • V-Y ADVANCEMENT OF VOLAR SKIN FLAPS PEDICLED BY DIGITAL AR-TERIES AND NERVES FOR RECONSTRUCTION OF DIGITAL SKIN DEFECT

    The traditional Kutler and Atasoy V-Y advancement flaps have minimal advancement degree, did not satisfy to repair large skin defect in fingers, hence, have no wide indications. The sensory function of the fingers to be influenced because of injury of sensory nerves and sear formation. Since 1985 to 1991, the V-Y advancement flaps pedicled by bilateral digital arteries and nerves have been used for reconstruction of 33 finger tip defect and 5 digital volar skin contraction. All of these cases obtained satisfactory function and excellent appearance.In this paper, the anatomical charactistics and principles of devicerecommended, the advantages and key points to success discussed.

    Release date:2016-09-01 11:38 Export PDF Favorites Scan
  • CLINICAL APPLICATION OF VASCULARIZED SKIN FLAP WITH NERVE (REPORT OF 10 CASES)

    The digital defects which severely interfered with the hand functions must be reconstructed. The primary repair by vascularized skin flap with the dorsal branch of proper palmar digital nerve could be done. The vascularized flap was rich in blood circulation, perfect sensibility and a good contour, as well as preserving donor digital sensation. However, it was simple, safe, and with higher success. From 1989 to 1991, 10 cases of digital defects were treated, all of the patients gained very good results. The indication and technique of thismethod wasdiscussed in detail.

    Release date:2016-09-01 11:38 Export PDF Favorites Scan
  • Clinical Application of Digital Gastrointestinal Machine and Modified Hypotonic DoubleContrast Barium Enema Technique

    ObjectiveTo improve the efficacy of colon doublecontrast barium enema examination by using digital gastrointestinal machine and modified enema techniques. MethodsSixtyfour patients were examined on digital remote controlled gyration table, with oral coloncleansing preparation and selfmade disposable plastic bag. Results In 64 patients, up to 93.8% were found with none or little fecal materials in the cecum and ascending colon. 80% of the results were scored excellent, and 95% were accurate for making diagnosis. All the patients underwent the examination successfully. ConclusionDigital gastrointestinal machine examination combined with modified hypotonic doublecontrast barium enema is a simple, convenient and efficient way to clearly demonstrate colonic mucosa, and help increase the detection and diagnosis rate.

    Release date:2016-08-28 04:43 Export PDF Favorites Scan
  • Single-Injection Digital Block versus Traditional Digital Block for Local Anesthesia in Digital Injury Patients: A Randomized Controlled Trial

    Objective To compare the anesthetic effects of traditional digital block with single-injection digital block in digital injury patients for subcutaneous digital blocks. Methods Patients with one or two digits injured were randomized to the traditional digital block group and single-injection digital block group. All of the blocks were conducted by one investigator. The patients and outcome assessor were blinded to the treatment allocation. Both of the per-protocol-population (PP) analysis and the intention-to-treatment (ITT) analysis were performed to compare the two block techniques in terms of the pain during infiltration, the onset time of anesthesia and the failure rate of anesthesia. Results A total of 93 patients (109 digits) were included with 51 (61 digits) in the traditional block group and 42 (48 digits) in the single-injection block group.Two patients (3 digits) dropped out. Both of the PP analysis and ITT analysis showed that no significant difference between the two groups were detected in terms of the pain during infiltration, the onset time of anesthesia and the failure rate of anesthesia (P﹥0.05). Conclusions The subcutaneous single-injection digital block is as effective as the traditional digital block, but is much easier to perform. This technique is indicated for the digital anesthesia of palmar aspect distal to the proximal digital crease and dorsal aspect of the distal and middle phalanxes.

    Release date:2016-09-07 02:18 Export PDF Favorites Scan
  • Application of digital drainage system after da Vinci robot-assisted lobectomy: A retrospective cohort study

    Objective To investigate the clinical effect of digital drainage system (DDS) in patients after robot-assisted lobectomy. MethodsThe clinical data of the patients who underwent da Vinci robot-assisted lobectomy from August 2020 to December 2021 were retrospectively analyzed. The patients were divided into a DDS group and a conventional group (using traditional single thoracic drainage tube device) according to different drainage devices used after operation. The preoperative data, intraoperative blood loss, total drainage volume within 48 h after operation, postoperative extubation time and postoperative hospital stay were compared between the two groups. ResultsFinally, 170 patients were collected, including 76 males and 94 females with an average age of 61.8±8.7 years. Postoperative extubation time [5.53 (6.00, 7.00) days vs. 6.36 (6.00, 8.00) days, Z=–2.467, P=0.014] and postoperative hospital stay [7.80 (8.00, 10.00) days vs. 8.94 (9.00, 10.00) days, Z=–2.364, P=0.018] in the DDS group were shorter than those in the conventional group. For patients with postoperative persistent air leak, postoperative extubation time (Z=–2.786, P=0.005) and postoperative hospital stay (Z=–2.862, P=0.003) in the DDS group were also shorter than those in the conventional group. ConclusionDDS has a positive effect on enhanced recovery after robot-assisted lobectomy, which is safe and stable, and is beneficial to postoperative rehabilitation and shortening the average hospital stay.

    Release date:2024-02-20 04:11 Export PDF Favorites Scan
6 pages Previous 1 2 3 ... 6 Next

Format

Content