west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Dislocation" 13 results
  • TREATMENT OF OLD DISLOCATION OF INFERIOR RADIO-ULNAR JOINT BY SHORTENING OPERATION OF PRONATOR QUADRTUS MUSCLE

    The dorsal dislocation inferior radio-ulnar joint was treated by the shortening operation of the pronator quadratus muscle by moving the muscle origin to its dorsum, so that the pronator quadratus muscle was always under tension whether the muscle was contracted or relaxed. Thus the anatomic position and stress distribution were improved. We had treated 11 patients in the past four years.The patients were followed from four months to four and half years and the results were 9 patients excellent and 2 good.

    Release date:2016-09-01 11:38 Export PDF Favorites Scan
  • TREATMENT OF LOWER CERVICAL FRACTURE DISLOCATION BY TITANIUM SCREW-PLATE INTERNAL FIXATION ON CERVICAL LATERAL MASS

    Objective To evaluate surgical results of the titanium screwplate internal fixation in treatment of the lower cervical fracture dislocation. Methods From September 2001 to March 2006, 31 patients(24 males, 7 females; age range, 2063 years) with the lower cervical fracturedislocation were treated in our department. The injuries were caused by a road accident in 25 patients, a high crash in 4, and a heavy object crash in 2. The fracture dislocation occurred in the following cervical segments:C3(1 patient),C4(5 patients), C5(12 patients), C6(10 patients), and C7(3 patients). The disease course ranged from 1 to 23 days. The associated spinal nerve root injury occurred in 29 patients. The Frankle scaling revealed that 14 patients were at Grade A, 3 at Grade B, 7 at Grade C, 3 at Grade D, and 2 at Grade E (associated nerve root injury with hand and shoulder numbness). The 29 patients underwentthe spinal cord decompression, the grafting fusion of the small joints, and thelateral mass titanium screwplate internal fixation; 2 patients without nerve injury underwent only the grafting fusion of the small joints and the lateral mass titanium screwplate internal fixation. The bone fusion, cervical vertebra movement, and internal fixation condition were observed by the X-ray examinations postoperatively. The nerve function recovery was evaluated by the Frankle scaling system. Results The followedup in all the patients for 6months to 4 years revealed that the small joint fusion time was 36 months, with an average of 3.6 months. The cervical X-ray films showed that there was no instability or fracture looseness of the internal fixation at 6 months. Among the 29 patients with the spinal nerve root injury, 14 were at Grade A preoperatively but 13 were improved at Grade B and 1 at Grade C postoperatively; 3 were at Grade B preoperatively but 2 were improved at Grade C and 1 at Grade D postoperatively; 7 were at Grade C preoperatively but 3 were improved at Grade D and 4 at Grade E postoperatively; 3 at Grade D preoperatively but all the 3 were improvedat Grade E postoperatively; 2 were at Grade E preoperatively and remained unchanged postoperatively. In the 2 patients with only the nerve root injury, numbness disappeared soon after operation. Conclusion This posteriorapproach has two advantages: the mobility range of the cervical vertebra can preserved to the greatest extent because of the short segment fixation; the betterstability can obtained because of the titanium screwplate internal fixation on the cervical jointcolumn to prevent the hyperextension and hyperflexion. Therefore, the titanium screwplate internal fixation on the cervical lateral massis an effective treatment of the lower cervical fracture dislocation.

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • A PRELIMINARY REPORT ON CLINICAL APPLICATION OF BIOPOLY ESTER LIGAMENT

    Sixty-one cases of fracture or dislocation were treated with France-made biopolyester ligament. They consisted of 18 cases of fracture of patella, 13 cases of fracture of olecranon, 8 cases of fracture of distal clavicle, 10 cases of dislocation of acromino-clavicular joint, 6 cases of separation of lower tibio-fibular joint, 3 cases of rapture of cruciate ligament and 3 cases of fracture of upper third of ulna with dislolcation of radial head. The follow-up period lasted from 3 to 12 months with an average of 7.3 months. The result showed that of the 56 follow-up cases, 49 were excellent and 7 were satisfactory. There was no redisplacement occured in this group. The Biopolyester ligament was believed to be a good and safe material for fractures or dislocations and was of good strength of extension and easy to use.

    Release date:2016-09-01 11:08 Export PDF Favorites Scan
  • TREATMENTS OF DISLOCATION AFTER TOTAL HIP REPLACEMENT

    Objective To explore the treatment of dislocation after total hip replacement. Methods From July 1997 to October 2004, 23 casesof dislocation after total hip replacement were treated,including 9 males and 14 females and aging 5379 years. The CT and serial X-ray films were taken to observe the position of prostheses. The strength of their hip abductor was also tested. In the patients without loosening, closed reduction was attempted at first. The stability of hip was tested. If closed reduction failed, the offset or/and parts of the components was adjusted, then the capsular was repaired. If instabilitystill existed, revision was adopted. Results In 23 cases of dislocation, 10 cases were treated successfully by closed reduction. In 12 patients who failed reduction, 5 were given open reduction combined with capsular repairing; the offset was adjusted by lengthening femoral head in 2 cases; rim liners were elevated in 2 cases; and larger offset was used and abnormal liner was adjusted in 1 case. Revision was used in 1 case having loosening and 2 cases having instability. Allpatients were followed up 1 year to 5 years (1.9 years on average). The Harrisscoring was 7294 (87 on average). Conclusion The treatment of dislocation after total hip replacement should use different ways according to the causes of dislocation and the stability of hip.

    Release date:2016-09-01 09:19 Export PDF Favorites Scan
  • Surgical treatment of the difficult reduction of shoulder joint dislocation combined with greater tuberosity fracture

    ObjectiveTo explore the clinical effect of open reduction and internal fixation with hollow screw fixation in the treatment of difficult reduction of shoulder joint dislocation combined with fracture of greater tuberosity of humerus.MethodsFrom January 2011 to March 2014, 15 patients with difficult reduction of shoulder joint dislocation combined with fracture of greater tuberosity of humerus were treated with open reduction and hollow screw fixation. There were 9 males and 6 females, aged from 45 to 77 years with an average of 63.5 years. The causes of injury included 7 cases of falls, 5 cases of high falling injury, and 3 cases of traffic accident injury. The injury-to-admission time was 2 hours to 5 days with an average of 1.5 days. The shoulder joint was the initial dislocation. The types of dislocation showed 14 cases of anterior dislocation and 1 case of posterior dislocation. There were 9 cases of simple avulsion fracture of greater tuberosity of humerus, 5 cases of comminuted fracture, 1 case of both greater tuberosity of humeru with small tuberosity of humerus fracture, and 2 cases of incomplete nerve injury; no exploration was carried out in operation.ResultsThere were 14 patients with wound healing at first intention; 1 suffered superficial infection of the wound, which healed by anti infection treatment. Fifteen cases were followed up for 6 to 18 months with an average of 12.2 months, with 1 case of shoulder joint re-dislocation 1 month after operation, and 2 cases of tuberosity of humerus defect absorption. One year after operation, the shoulder joint function were evaluated according to Neer Scoring System, and the results were excellent in 9 cases, good in 3 cases, fair in 2 cases, and poor in 1 case, with the excellent and good rate of 80.0%.ConclusionThe curative effect of open reduction and internal fixation with hollow screw fixation on difficult reduction of shoulder joint dislocation combined with fracture of greater tuberosity of humerus is remarkable, which can obtain satisfactory shoulder joint function.

    Release date:2018-09-25 02:22 Export PDF Favorites Scan
  • CLINICAL STUDY ON SURGICAL REPAIR OF ACUTE ACROMIOCLAVICULAR DISLOCATION BY MODIFIED WEAVER-DUNN TECHNIQUE

    Objective To investigate the clinicalvalue of modified Weaver-Dunn technique in repair of acute acromioclavicular dislocation. Methods From January 1993 to December 1998, 18 cases of acromioclavicular dislocation were treated bymodified Weaver-Dunn technique, and other 17 cases of the same suffering were treated by tension band fixation of the acromioclavicular joints. All of the patients were followed up for 12-36 months before clinical evaluation of the functionof shoulder joints, according to University of Pennsylvanian Shoulder Score System. Results In short term, the shoulder joints recovered much more rapidly in the cases repaired by modified Weaver-Dunn technique; 12, 24 and 36 months after operation, the scores of the cases repaired by modified Weaver-Dunn technique were (1897±67), (193.7±3.6) and (194.7±3.4) respectively according to the Shoulder Score System, while those of the cases treated by tension band fixation were (167.3±7.8), (170.2±6.3) and (165.6±5.9) respectively. The above data indicated that there was significant difference between two groups (P<0.05). Conclusion The modified Weaver-Dunn technique was a better surgical approach than tension band fixation for repair of acute acromioclavicular dislocation.

    Release date: Export PDF Favorites Scan
  • Characteristics and clinical significance of irreducible Pipkin type Ⅰ and Ⅱ femoral head fracture-dislocations

    Objective To summarize the characteristics and clinical significance of irreducible Pipkin type Ⅰ and Ⅱ femoral head fracture-dislocations. Methods The clinical data of 4 patients with irreducible Pipkin type Ⅰ and Ⅱ femoral head fracture-dislocations between January 2010 and December 2019 were collected. There were 2 males and 2 females and the age ranged from 24 to 41 years, with an average age of 33.5 years. The cause of injury included traffic accident in 3 cases and falling in 1 case. Pipkin classification was 2 cases of type Ⅰ and 2 cases of type Ⅱ. The time from injury to operation was 1-2 days. The clinical features were that the hip joint of the affected limb was in a locked position, and the passive range of motion was poor. The affected limb was slightly flexed at the hip joint and shortened, in a state of neutral position or slight adduction and internal rotation. The imaging data suggested that the femoral head dislocated backward and upward, and the hard cortex of the posterior edge of the acetabulum was embedded in the cancellous bone of the femoral head, and the two were compressed and incarcerated. Patients of cases 1-3 underwent closed reduction of hip dislocation 1-2 times at 3, 1, and 3 hours after injury respectively, and femoral neck fracture occurred. The injury types changed to Pipkin type Ⅲ, and open reduction and internal fixation were performed. Patient of case 4 did not undergo closed reduction, but underwent open reduction and internal fixation directly. Results Patients of cases 1-3 were followed up 14, 17, and 12 months, respectively. They developed osteonecrosis of the femoral head at 9, 5, and 10 months after operation respectively, and all underwent total hip arthroplasty. Patient of case 4 was followed up 24 months and had no hip pain and limited mobility; the imaging data indicated that the internal fixator position was good and the fracture healed; no collapse or deformation of the femoral head was seen, and no osteonecrosis of the femoral head occurred. Conclusion Clinicians need to improve their understanding of the unique clinical features and imaging findings of irreducible Pipkin type Ⅰ and Ⅱ femoral head fracture-dislocations. It is suggested that open reduction and simultaneous fixation of femoral head fracture should be directly used to reduce the incidence of osteonecrosis of the femoral head.

    Release date:2022-03-22 04:55 Export PDF Favorites Scan
  • BIOMECHANICAL RECONSTRUCTION OF DISLOCATION OF PATELLA

    From 1974 to 1993, 20 patients with dislocation of patella in 26 knees were treated by surgical technique, including 11 males and 9 females, aged from 10 to 67,averaged 31 year old. Thirteen cases (16 knees) were available for followup with an average period of 6.4 years. Using the criteria of Insall, the result were excellent in 5 knees, good in 5 knees, fair in 3 knees and poor in 3 knees with a success rate of 62%. Based on the biomechanism of patella movement and the findings in this study, the mechanism of dislocation of patella and its biomechanical reconstruction principle as well as the factors influencing the operative results were discussed.

    Release date:2016-09-01 11:12 Export PDF Favorites Scan
  • OPERATIVE TREATMENT OF TERRIBLE TRIAD OF THE ELBOW

    Objective To retrospectively reviewed the operative therapy of the terrible triad of the elbow. Methods From October 2003 to September 2007, 10 cases of terrible triad were treated, with an elbow dislocation and an associated fracture of both the radial head and the coronoid process. There were 3 males and 7 females with the age of 18-66 years. The injury was caused by traffic accidents in 4 cases, fall ing from a height in 4 cases, and tumbl ing in 2 cases. The coronoid process fractures of the patients were 5 cases of type I, 3 cases of type II and 2 cases of type III according to Regan- Morrey classification. The radial head fractures of the patients were 1 case of type I, 6 cases of type II and 1 case of type IIIaccording to Mason classification, and their radial heads of the other 2 patiants were resected before they were in hospital. The general approach was to repair the damaged structures sequentially from deep to superficial, from coronoid to anterior capsule to radial head to lateral l igament complex to common extensor origin. And selected cases were repaired of the medial collateral l igaments and assisted mobile hinged external fixation to keep the forearm fixed in functional rotation position. The function of the elbows were evaluated with the criteria of the HSS2 score system. Results The other wounds healed by first intention except 1 case which had infection 7 days after operation and whose soft tissue defect in posterior elbow were repaired with the pedicle thoracoumbil ical flap. The patients were followed up 6 to 51 mouths (mean 24.9 mouths). The fracture heal ing time was 6 to 20 weeks (mean 9.6 weeks). Six mouths postoperatively, the mean flexion-extension arc of the elbow was 106.5° (85-130°), and the mean pronation-supination arc of the forearm was 138°( 100-160°) respectively. According to the criteria of the HSS2 score, the results were excellent in 4 cases, good in 4 cases, and fair in 2 cases. No compl ications such as stiffness and ulnohumeral arthrosis occurred. The radial nerve injury was found in 1 patient 1 day after operation who was treated with neurolysis, and the nerve function was recovered after 4-6 months. And heterotopic ossification occurred in 6 patients 6 months after operation and radiographic subluxation developed in 1 patient 36 months after operation, and conservative treatment weregiven. Conclusion The terrible triad of the elbow can lead to serious elbow instabil ity and should be treated with operationto restore the anatomic structures, to repair the articular capsule and the collateral l igament, using the adjuvant hinged external fixation and early exercise to avoid immobil ization and recover the articular function.

    Release date:2016-09-01 09:05 Export PDF Favorites Scan
  • SHORT-TERM EFFECTIVENESS OF TightRope SYSTEM FOR TREATMENT OF SYNDESMOTIC TIBIOFIBULAR DIASTASIS

    ObjectiveTo summarize the short-term effectiveness of TightRope system for the treatment of syndesmotic tibiofibular diastasis. MethodsBetween June 2013 and June 2015, 23 patients with syndesmotic tibiofibular diastasis were treated by TightRope system, including 15 males and 8 females with an average age of 32.3 years (range, 16-63 years). Injury was caused by sports in 13 cases, by traffic accident in 6 cases, and by falling from height in 4 cases. The locations were the left side in 13 cases and the right side in 10 cases. The time from injury to operation was 6 hours to 12 days (mean, 3.8 days). According to Lauge-Hansen classification, 13 cases were rated as supination-external rotation type, 7 cases as pronation-abduction type, and 3 cases as pronation-external rotation type; according to Weber classification, 5 cases were rated as type A, 11 cases as type B, and 7 cases as type C. ResultsThe mean operative time was 68.1 minutes (range, 48-93 minutes); the mean intraoperative blood loss was 70.3 mL (range, 20-150 mL); and the mean hospitalization days were 7 days (range, 5-13 days). Superficial local skin necrosis occurred in 6 cases, and primary healing of incision was obtained in the others. All patients were followed up 8-30 months (mean, 16.4 months). X-ray films showed bone union was achieved within 6-12 weeks (mean, 9.4 weeks). No related complications of reduction failure and re-fracture occurred. The internal fixators were removed at 10-18 months postoperatively (mean, 13.3 months). According to American Orthopaedic Foot and Ankle Society (AOFAS) score for ankle function evaluation, the results were excellent in 19 cases and good in 4 cases at last follow-up. ConclusionTightRope system is a good method to treat syndesmotic tibiofibular diastasis, because of safety, convenient operation, and satisfactory short-term effectiveness.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content