ObjectiveTo compare the short-term effectiveness between Gamma 3 intramedullary nails and Gamma 3 U-Blade system in the treatment of osteoporotic intertrochanteric fractures in the elderly. Methods A retrospective analysis was conducted on the clinical data of 124 elderly patients with osteoporotic intertrochanteric fractures, who were admitted between February 2020 and February 2023 and met the selection criteria. The fractures were fixed with Gamma 3 intramedullary nails in 65 patients (control group) and Gamma 3 U-Blade systems in 59 patients (UB group). The differences between the two groups were not significant in age, gender, body mass index, American Society of Anesthesiologists (ASA) classification, bone mineral density, time from injury to operation, fracture classification, and affected side (P>0.05). The operation time, intraoperative blood loss, hospital stay, and fracture healing time were recorded; the tip-apex distance, fracture reduction quality, and lag screw position were evaluated on X-ray films at immediate after operation; the lag screw sliding distance and change value of neck-shaft angle were measured on X-ray films at last follow-up. Harris hip score at 1 year after operation and the occurrence of internal fixation-related complications were compared between the two groups. Results The operation time, intraoperative blood loss, and hospital stay in the UB group increased compared to the control group, but the differences were not significant (P>0.05). All patients in both groups were followed up 12-24 months (mean, 17.1 months). At 12 months after operation, there was no significant difference in the Harris hip score between the two groups (P<0.05). Radiological examination showed that there was no significant difference between the two groups (P>0.05) in terms of tip-apex distance, fracture reduction quality, and lag screw position. Fractures healed in both groups, and there was no significant difference in healing time (P>0.05). At last follow-up, the change value of neck-shaft angle and lag screw sliding distance in the UB group were significantly lower than those in the control group (P<0.05). During follow-up, no related complications occurred in the UB group, while 6 cases (9.2%) in the control group experienced complications, and the difference in the incidence was significant (P<0.05). ConclusionFor the osteoporotic intertrochanteric fractures in the elderly, the Gamma 3 U-Blade system fixation can achieve good short-term effectiveness, with better imaging results compared to Gamma 3 intramedullary nails fixation.
Objective To analyse the factors of complications aftertreatment of intertrochanteric fractures with Gamma nail. Methods From January 1998 to May 2004, 50 patients were treated with Gamma nail, including 18 males and 32 females and ageing from 47 to 82 years. The locations were the left side in 16 cases andthe right in 34 cases. According to Evans classification, there were 4 cases oftype Ⅰ, 2 cases of type Ⅱ, 23 cases of type Ⅲ, 10 cases of type Ⅳ and 11 cases of type Ⅴ. Results Fifty patients were followed up 429 months. Accordingto the Harris criterion for evaluation, the results were excellent and good in 35 cases, showing sthenic weight loading walking and normal range of motion of the hip joint. The postoperative complications appeared in 15 cases: 5 cases of coxa vara or coxa valga, 3 cases of rotation deformity of lower limb, 2 cases oftension screwprotrusions and lower shorten, 1 case of failure of internal fixation, 1 case of femoral fracture, 2 cases of coxalgia and 1 case of pain in knee joint and stiff knee joint. Conclusion The reason of complications was various, mainly lies in insufficient comprehension and analysis of the types of fractures, unfamiliarity with the characteristics and usage of the instruments and neglected rehabi litation instruction, inappropriate functional training and too early weight loading after operation.
Objective To evaluate the surgical efficiency of treating the intertrochanteric hip fracture with the Gamma nail fixation and to compare two operating methods of the Gamma nail fixation. Methods From August 2000 to August 2006, 69 patients (32 males, 37 females; age, 43-98 years;average, 72.3 years)with the intertrochanteric hip fracture but with no associated injury weretreated with the Gamma nail fixation. The patients’ average illness course was 5.6 days (range, 3-14 days). Among the 69 patients, 36 were treated with the traditional method of the Gamma nail fixation (Group A) and 33 were treated with animproved method of the Gamma nail fixation (Group B). According to the Association for the Study of Internal Fixation (AO-ASIF) classification, in Group A, 5 patients had a disease of Type A1, 23 of Type A2, and 8 of Type A3; inGroup B, 8 patients had a disease of Type A1, 21 of Type A2, and 4 of Type A3. The data from the two groups were analyzed, and the statistical analysis was made on the following aspects: incision length, operating time, intraoperative bleeding, X-ray exposure frequency, drainage amount, blood transfusion volume, postoperative infection of the lungs, superficial infection of the incision, duration of antibiotic use, standing with the walking stick after operation, complication due to internal fixation, healing time for the fracture, and the hip function recovery half a year after operation assessed with the Harris scoring system. Results All the 69 patients were followed up for 8-80 months(average, 42 months). We studied the indexes such as incision length, operating time, intraoperative bleeding, X-ray exposure frequency, drainage amount, and blood transfusion volum; aboveindexes in Group A were 9.5±4.7 cm, 85±35 min, 186.0±87.3 ml, 9.0±5.1 times, 102.7±49.8 ml, 325.0±169.5 ml; and those were 5.3±1.2 cm,46±10 min, 65.0±26.0 ml,3.0±2.1 times,52.5±16.2 ml,203.0± 61.2 ml in Group B. The above indexes showed that the surgical efficiency in Group B was significantly better than that in Group A (Plt;0.05). The postoperative recoveryindexes such as infection of the lungs, infection of the incision, duration of antibiotic use, standing time after operation, union time of fracture, and functionscore, were studied. There was a statistically significiant difference in lung infection, incision infection, duration of antibiotic use, and standing time after operation between Group A and Group B(Plt;0.05). Conclusion The improved method of the Gamma nail fixation fortreating the intertrochanteric hip fracture can increase the surgical efficiency and improve the patient’s early recovery after operation, especially suitable for the elderly patients who have more complications. This kind of method can shorten the operating time and the anesthesia duration, reducing the incision infection and the blood loss during operation, and decrease the frequency of the X-ray use.
Objective To investigate the reasons of failure of Gamma nail treatment for intertrochanteric fractures and define operative techniques of the revision surgery. Methods From January 1999 to January 2008, 20 cases of 432 patients treated with Gamma nails for intertrochanteric fractures were revised. There were 9 males and 11 females, aged 24-87 years (median 65 years). Among them, there were 4 cases of femoral shaft fracture, 2 cases of screw penetrating the femoral head,11 cases of screw cutting out the femoral head and neck, 2 cases of internal rotation malformation, and 1 case of nfection. The operative procedures of revision were as follows: 4 cases were treated with the long Gamma nail, 4 cases by adjusting the position of Gamma nail, 11 cases with artificial femoral head replacement, and 1 case by removing Gamma nail and debriding and reimplant the Gamma nail. Results The hospital ization days were 16-28 days (21.2 days on average); the bleeding volume during operation was 150-600 mL (380 mL on average). All wounds healed by first intention. Bed rest days were 7-15 days (12.5 days on average). All the patients were followed up for 1-8 years (5 years on average). The operations were successful, the femoral intertrochanteric fracture and femoral shaft fracture reached bony union. Compl ications such as loosening, breakage of hardware and coxa adduct were not observed. No loosening and dislocation of the prosthesis occurred. Among the patients with compl ications, 9 patients were treated with a Gamma nail again. Fracture heal ing was achieved within 2 to 5 months, with an average of 3 months. According to the WANG Fang et al. criterion for hip joint function, the results were excellent in 7 cases and good in 2 cases. In 11 patients who receieved artificial femoral head replacement, the hip joint function restored to normal. Harris score was 90-93. Conclusion Various causes such as osteoporosis, ti p-apex distance ( 25 mm), femoral shaft malformation, Gamma nail shortcomings may lead to compl ications after Gamma nail treatment for intertrochanteric fractures. Good results will be achieved by different revision techniques.
Objective To confirm the association between tail femur distance (TFD) and lag screw migration or cutting-out in the treatment of intertrochanteric fracture with the third generation of Gamma nail (TGN). Methods The clinical data of 124 cases of intertrochanteric fracture treated with TGN internal fixation and followed up more than 18 months between January 2012 and December 2015 were reviewed and analyzed. There were 52 males and 72 females, with an age of 46-93 years (mean, 78.5 years). According to AO/Association for the Study of Internal Fixation (AO/ASIF) classification, 43 cases were type 31-A1, 69 cases were type 31-A2, and 12 cases were type 31-A3. The time from injury to operation was 1-10 days (mean, 2.9 days). According to the fracture healing of the patients, the patients were divided into the healing group and failure group. The age, gender, height, bone mineral density (BMD), fracture AO/ASIF classification, the time from injury to operation, and the TFD value at 1 day after operation were recorded and compared. The risk factors for the migration or cutting-out of lag screw were analyzed by logistic regression. Results There were 111 cases in healing group, the healing time was 80-110 days (mean, 95.5 days). There were 13 cases in failure group, including 2 cases of lag screw cutting-out and 11 cases of significant migration. Except for the TFD value at 1 day after operation in failure group was significantly higher than that in the healing group(t=5.14, P=0.00), there was no significant difference in gender, age, height, BMD, fracture of AO/ASIF classification, and the time from injury to operation (P>0.05) between 2 groups. logistic regression analysis showed that TFD value was a risk factor for the migration or cutting-out of lag screw (B=1.22, standardized coefficient=0.32, Wald χ2=14.66, P=0.00, OR=3.37). Conclusion The patients with higher TFD value had higher risk of postoperative lag screw migration or cutting-out. This result indicates that the appropriate length of the lag screw is helpful to reduce TFD value and prevent postoperative lag screw migration or cutting-out.
ObjectiveTo explore the difference of the proximal femoral shortening (PFS) between the third generation of Gamma nail (TGN) and the proximal femoral nail anti-rotation (PFNA) in treating intertrochanteric fracture of femur.MethodsThe clinical data of 158 patients with intertrochanteric fracture of femur who were treated with TGN internal fixation or PFNA internal fixation between January 2014 and December 2015 were retrospectively analysed. The patients were divided into TGN group (69 cases) and PFNA group (89 cases) according to surgical operation. There was no significant difference in gender, age, bone mineral density, causes of injury, AO/Association for the Study of Internal Fixation (AO/ASIF) classification, accompanied disease, and the time from injury to operation between 2 groups (P>0.05). The result of fracture reduction was divided into 3 types: positive medial cortex support, neutral position cortex support, and negative medial cortex support according to the method of Changet al. At 18 months postoperatively, bilateral hip anteroposterior X-ray films were taken to measure horizontal PFS values (marked as X), vertical PFS values (marked as Y), and calculate the total PFS values (marked as Z). The PFS values were divided into 4 grades according to the criteria (≤1.0 mm, 1.0-4.9 mm, 5.0-9.9 mm, and ≥10.0 mm), and the constituent ratio was calculated and compared between 2 groups. The X, Y, and Z values and the collodiaphyseal angles of 2 groups at 18 months postoperatively were compared. The X, Y, and Z values of 2 groups of patients with failed fixation and normal healing within 18 months after operation were recorded and compared. The X, Y, and Z values of 2 groups of the patients with different cortex support types were also compared.ResultsThere were 34 cases of positive medial cortex support, 30 cases of neutral position cortex support, and 5 cases of negative medial cortex support in TGN group, and there were 45, 33, and 11 cases in PFNA group respectively, showing no significant difference between 2 groups (Z=–1.06, P=0.29). All patients were followed up 18 months after operation. At 18 months after operation, the constituent ratios of PFS values (X, Y, Z) had significant differences between 2 groups (P<0.05). The patients of shortening of 1.0-4.9 mm and 5.0-9.9 mm were obviously more in TGN group than in PFNA group; the patients of shortening of ≥10.0 mm were obviously more in PFNA group than in TGN group. There were significant differences in X, Y, and Z values between 2 groups (P<0.05), but no significant difference of the collodiaphysial angle was found between 2 groups (t=0.47, P=0.64). Six cases of internal fixation failed in TGN group and PFNA group respectively within 3 months after operation, and there was no significant difference of X, Y, and Z values between failed fixation and normal healing patients within 2 groups (P>0.05). When the reposition effect was the positive medial cortex support, the X, Y, and Z values were significantly lower in TGN group than in PFNA group (P<0.05); but no significant difference was found between 2 groups when the reposition effect was the neutral position cortex support or negative medial cortex support (P>0.05). At 18 months after operation, the X, Y, and Z values of the negative medial cortex support patients were significantly higher than those of the positive medial cortex support or the neutral position cortex support patients within 2 groups (P<0.05).ConclusionPFS is a common complication of the intertrochanteric fracture of the femur after internal fixation. During operation, the selection of internal fixation should be based on the results of intraoperative reduction. TGN should be applied to reduce PFS if positive medial cortex support happened.
Repeated transcranial magnetic stimulation (rTMS) is one of the commonly used brain stimulation techniques. In order to investigate the effects of rTMS on the excitability of different types of neurons, this study is conducted to investigate the effects of rTMS on the cognitive function of mice and the excitability of hippocampal glutaminergic neurons and gamma-aminobutyric neurons from the perspective of electrophysiology. In this study, mice were randomly divided into glutaminergic control group, glutaminergic magnetic stimulation group, gamma-aminobutyric acid energy control group, and gamma-aminobutyric acid magnetic stimulation group. The four groups of mice were injected with adeno-associated virus to label two types of neurons and were implanted optical fiber. The stimulation groups received 14 days of stimulation and the control groups received 14 days of pseudo-stimulation. The fluorescence intensity of calcium ions in mice was recorded by optical fiber system. Behavioral experiments were conducted to explore the changes of cognitive function in mice. The patch-clamp system was used to detect the changes of neuronal action potential characteristics. The results showed that rTMS significantly improved the cognitive function of mice, increased the amplitude of calcium fluorescence of glutamergic neurons and gamma-aminobutyric neurons in the hippocampus, and enhanced the action potential related indexes of glutamergic neurons and gamma-aminobutyric neurons. The results suggest that rTMS can improve the cognitive ability of mice by enhancing the excitability of hippocampal glutaminergic neurons and gamma-aminobutyric neurons.
Genetic epilepsy with febrile seizures plus (GEFS+) is a new type of genetic epilepsy syndrome with a marked hereditary tendency. Febrile seizure is the most common clinical symptom, followed by febrile seizure plus, and with/without absence seizures, focal seizures, and generalized tonic-clonic seizures. Results of the polymerase chain reaction (PCR), exon sequencing and single nucleotide polymorphism (SNP) analysis showed that the occurrence of GEFS+ is mainly related to the mutation of gamma aminobutyric acid type A receptor gamma 2 subunit (GABRG2), but its pathogenesis was still unclear. The main types of GABRG2 mutations include missense mutation, nonsense mutation, frameshift mutation, point mutation and splice site mutation. All these types of mutations can reduce the function of ion channels on cell membrane, but the degree and mechanism of dysfunction are different, which may be the main mechanism of epilepsy. This article will focus on the relationship between GEFS+ and the mutation types of GABRG2 in recent years, which is of great significance for clinical accurate diagnosis, anti-epileptic treatment strategy and new drug development.
The acoustic detection method based on machine learning and signal processing is an important method of pathological voice detection and the extraction of voice features is one of the most important. Currently, the features widely used have disadvantage of dependence on the fundamental frequency extraction, being easily affected by noise and high computational complexity. In view of these shortcomings, a new method of pathological voice detection based on multi-band analysis and chaotic analysis is proposed. The gammatone filter bank was used to simulate the human ear auditory characteristics to analyze different frequency bands and obtain the signals in different frequency bands. According to the characteristics that turbulence noise caused by chaos in voice will worsen the spectrum convergence, we applied short time Fourier transform to each frequency band of the voice signal, then the feature gammatone short time spectral self-similarity (GSTS) was extracted, and the chaos degree of each band signal was analyzed to distinguish normal and pathological voice. The experimental results showed that combined with traditional machine learning methods, GSTS reached the accuracy of 99.50% in the pathological voice database of Massachusetts Eye and Ear Infirmary (MEEI) and had an improvement of 3.46% compared with the best existing features. Also, the time of the extraction of GSTS was far less than that of traditional nonlinear features. These results show that GSTS has higher extraction efficiency and better recognition effect than the existing features.
ObjectiveTo compare the therapeutic effect between intramedullary fixation and external fixation on intertrochanteric fracture. MethodsBetween June 2005 and June 2011, 32 patients with Evans-Jensen type Ⅲ intertrochanteric fracture were treated with proximal femoral nail anti-rotation (PFNA), Gamma nail, dynamic hip screw plate (DHS) or locking compression plate (LCP), separately. The operation duration, peri-operative bleeding, load time, Harris hip score and postoperative complications were observed in the patients, and were used to analyze the therapeutic effect among the four methods. ResultsShorter operation duration, less bleeding in the surgery, smaller quantity of drainage after the operation (P<0.05) were found in group Gamma and group PFNA compared with those in group DHS and LCP. The duration of hospitalization didn't differ much between the two fixation systems (P>0.05). The difference in operation duration, operative bleeding and post-operative drainage between group Gamma and PFNA, and between group DHS and LCP was not significant (P>0.05). ConclusionThe intramedullary fixation was better than external fixation for Evans-Jensen type Ⅲ intertrochanteric fracture.