Riboflavin-ultraviolet A (UVA) collagen cross-linking has not only achieved good clinical efficacy in the treatment of corneal diseases such as dilatation keratopathy, bullae keratopathy, infectious keratopathy, and in the combined treatment of corneal refractive surgeries, but also its efficacy and safety in scleral collagen cross-linking have been initially confirmed. To better promote the application of cross-linking in the clinical treatment of corneal and scleral diseases, exploring controllability and predictability of the surgical efficacy are both important for evaluating the surgical efficacy and personalized precision treatment. In this paper, the progress on the cross-linking depth of riboflavin-UVA collagen cross-linking, and its relationship with the cross-linking effect will be reviewed. It will provide the reference for further application of this procedure in ophthalmology clinics.
The mechanical properties of the aorta tissue is not only important for maintaining the cardiovascular health, but also is closely related to the development of cardiovascular diseases. There are obvious differences between the ventral and dorsal tissues of the descending aorta. However, the cause of the difference is still unclear. In this study, a biaxial tensile approach was used to determine the parameters of porcine descending aorta by analyzing the stress-strain curves. The strain energy functions Gasser-Ogden-Holzapfel was adopted to characterize the orthotropic parameters of mechanical properties. Elastic Van Gieson (EVG) and Sirius red stain were used to observe the microarchitecture of elastic and collagen fibers, respectively. Our results showed that the tissue of descending aorta had more orthotropic and higher elastic modulus in the dorsal region compared to the ventral region in the circumferential direction. No significant difference was found in hyperelastic constitutive parameters between the dorsal and ventral regions, but the angle of collagen fiber was smaller than 0.785 rad (45°) in both dorsal and ventral regions. The arrangement of fiber was inclined to be circumferential. EVG and Sirius red stain showed that in outer-middle membrane of the descending aorta, the density of elastic fibrous layer of the ventral region was higher than that of the dorsal region; the amount of collagen fibers in dorsal region was more than that of the ventral region. The results suggested that the difference of mechanical properties between the dorsal and ventral tissues in the descending aorta was related to the microstructure of the outer membrane of the aorta. In the relatively small strain range, the difference in mechanical properties between the ventral and dorsal tissues of the descending aorta can be ignored; when the strain is higher, it needs to be treated differently. The results of this study provide data for the etiology of arterial disease (such as arterial dissection) and the design of artificial blood vessel.
China is the country with high incidence of high myopia in the world. High myopia can cause severe vision impairment. So far, there is no effective treatment for high myopia in clinic. Scleral collagen cross-linking surgery has been proven to be effective in preventing animal eye axial elongation in vitro and in vivo. However, the influence of posterior scleral collagen cross-linking on the deformation of the whole eyeball is still unclear. In this study, finite element simulation were used to analyze the changes of eyeball shape and the position of light casting on the retina after posterior sclera cross-linking, and the mathematical algorithm was written to verify their similarity. The results showed that the shape of the whole eyeball was still very similar before and after cross-linking, and the diopter of the eyeball after cross-linking had little change, which had almost no effect on the position of light projection on the retina. Our results indicate that posterior sclera cross-linking wouldn’t lead to distortion to the optometry, that is, the increase of elastic modulus in local scleral tissue after cross-linking wouldn’t cause new problem of optometry and vision.
The decrease of corneal stiffness is the key factor leading to keratoconus, and the corneal collagen fiber stiffness and fiber dispersion are closely related to the corneal biomechanical properties. In this paper, a finite element model of human cornea based on corneal microstructure, namely collagen fiber, was established before and after laser assisted in situ keratomileusis (LASIK). By simulating the Corvis ST process and comparing with the actual clinical results, the hyperelastic constitutive parameters and corneal collagen fiber stiffness modulus of the corneal material were determined before and after refractive surgery. After LASIK, the corneal collagen fiber stiffness modulus increased significantly, and was highly correlated with central corneal thickness (CCT). The predictive relationship between the corneal collagen fiber stiffness modulus and the corresponding CCT before and after surgery was: k1 before = exp(9.14 − 0.009CCTbefore), k1 after = exp(8.82 − 0.008CCTafter). According to the results of this study, the central corneal thickness of the patient can be used to estimate the preoperative and postoperative collagen fiber stiffness modulus, and then a personalized corneal model that is more consistent with the actual situation of the patient can be established, providing a theoretical reference for more accurately predicting the safe surgical cutting amount of the cornea.
Study of the mechanical properties of in vivo corneal materials is an important basis for further study of corneal physiological and pathological phenomena by means of finite element method. In this paper, the elastic coefficient (E) and viscous coefficient (η) of normal cornea and keratoconus under pulse pressure are calculated by using standard linear solid model with the data provided by corneal visualization scheimpflug technology. The results showed that there was a significant difference of E and η between normal cornea and keratoconus cornea (P < 0.05). Receiver operating characteristic curve analysis showed that the area under curve (AUC) for E, η and their combined indicators were 0.776, 0.895 and 0.948, respectively, which indicated that keratoconus could be predicted by E and η. The results of this study may provide a reference for the early diagnosis of keratoconus and avoid the occurrence of keratoconus after operation, so it has a certain clinical value.
The effect of parasitic ions on the results of ultraviolet A (UVA) cross-linking in iontophoresis was still not clear. In this work, the porcine sclera was cross-linked by riboflavin lactate Ringer’s solution (group A) and riboflavin normal saline (group B) in vitro, respectively. The concentration of parasitic ions in the solution was calculated. In addition, the average fluorescence intensity, penetration depth and concentration after the introduction of riboflavin and the mechanical properties of cross-linked sclera tissue were measured. The ranges of diffusion coefficient of the two solutions were also calculated, respectively. The results showed that more kinds of parasitic ions were detected in group A compared with group B, while the average fluorescence intensity, penetration depth and concentration of riboflavin and scleral elastic modulus in group B were significantly higher than those in group A when the penetration time was 10 minutes. Besides, the diffusion coefficient of riboflavin in group B was about 1.5 times larger than that in group A. The results suggested that the species of parasitic ions has a great impact on the permeability of riboflavin, and affects the mechanical properties of cross-linked sclera. The above results could provide a reference for improving the efficiency of riboflavin introduction and optimizing the formula of riboflavin in iontophoresis scleral cross-linking.
ObjectiveTo understand the distribution characteristics and nosocomial infection of carbapenem-resistant Enterobacteriaceae (CRE) in a general hospital of traditional Chinese medicine, so as to provide the evidence for control and management of multidrug-resistant bacteria.MethodsData of CRE in the first Affiliated Hospital of Anhui University of Traditional Chinese Medicine were analyzed retrospectively from 2014 to 2018.ResultsThe total detection rate of CRE was 10.76%, 5.58%, 15.42%, 12.94% and 16.18% from 2014 to 2018, respectively. The detection rate of CRE showed a gradual upward trend (χ2=29.940, P<0.001). The highest number of CRE isolated from clinical specimens was sputum (355 strains, 63.39%), and the next were urine (98 strains, 17.50%) and secretions (38 strains, 6.79%). CRE isolated from different clinical departments were mainly in Neurosurgery Department (172 stains, 30.71%), Intensive Care Unit (Internal Medicine) (145 strains, 25.89%), Intensive Care Unit (Surgery)(106 strains,18.93%), and other internal medical departments (83 strains, 14.82%). A total of 179 patients developed CRE nosocomial infection in the past 5 years, who were mainly male, and with advanced age, long hospital stay, basic diseases, abnormal immune function and invasive operation. The incidence of hospital infection with CRE from 2014 to 2018 were 0.31‰, 0.38‰, 0.89‰, 0.80‰ and 1.14‰, respectively, which also showed a gradual upward trend (χ2=25.111, P<0.001).ConclusionWith the increasing number of clinically isolated CRE strains and the increasing incidence of nosocomial infection of CRE, effective intervention measures should be taken to prevent and control CRE.
Femtosecond laser small incision lenticule extraction (SMILE) with different residual stromal thicknesses (RST) is set to investigate its effect on corneal biomechanical properties of rabbits in vivo. In this study, 24 healthy adult Japanese rabbits were randomly divided into group A and B. The RST of group A was set 30% of the corneal central thickness (CCT), and the RST of group B was 50% of the CCT. The thickness of the corneal cap in both groups was set one third of CCT. Corneal visualization Scheimpflug technology (Corvis ST) and Pentacam three-dimensional anterior segment analyzer were used to determine corneal biomechanical and morphological parameters before surgery, and 1 week, 1 month and 3 months after surgery. Pearson correlation analysis was used to analyze factors affecting corneal biomechanical parameters after SMILE. The results showed that the corneal stiffness of group A was significantly higher than that of group B at 1 week and 1 month after surgery, and most biomechanical parameters returned to preoperative levels at 3 months postoperatively. The results of correlation analysis showed that postoperative CCT and RST were the main factors affecting corneal biomechanical parameters after SMILE. There was no significant difference in corneal posterior surface height (PE) between 3 months after surgery and before surgery in both two groups. It indicates that although the ability to resist deformation of cornea decreases in SMILE with thicker corneal cap and less RST, there is no tendency to keratoconus, which may be related to the preservation of more anterior stromal layer.
The mechanical properties of the cornea in corneal ectasia disease undergo a significant reduction, yet the alterations in mechanical properties within distinct corneal regions remain unclear. In this study, we established a rabbit corneal ectasia model by employing collagenase II to degrade the corneal matrix within a central diameter of 6 mm. Optical coherence tomography was employed for the in vivo assessment of corneal morphology (corneal thickness and corneal curvature) one month after operation. Anisotropy and viscoelastic characteristics of corneal tissue were evaluated through biaxial and uniaxial testing, respectively. The results demonstrated a marked decrease in central corneal thickness, with no significant changes observed in corneal curvature. Under different strains, the elastic modulus of the cornea exhibited no significant differences in the up-down and naso-temporal directions between the control and model groups. However, the cornea in the model group displayed a significantly lower elastic modulus compared to the control group. Specifically, the elastic modulus of the central region cornea in the model group was significantly lower than that of the entire cornea within the same group. Moreover, in comparison to the control group, the cornea in the model group exhibited a significant increase in both creep rate and overall deformation rate. The instantaneous modulus and equilibrium modulus were significantly reduced in the model cornea. No significant differences were observed between the entire cornea and the central cornea concerning these parameters. The results indicate that corneal anisotropy remains unchanged in collagenase-induced ectatic cornea. However, a significant reduction in viscoelastic properties is noticed. This study provides valuable insights for investigating changes in corneal mechanical properties within different regions of ectatic corneal disease.