west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Lumbar vertebra" 27 results
  • SURGICAL TREATMENT OF LUMBAR SPONDYLOLISTHESIS WITH CAGES AND TRANSPEDICAL SCREWS

    Objective To observe the effect of threaded titanium cage and transpedical screw for the treatment of lumbar spondylolisthesis. Methods Eighteen patients with lumbar spondylolisthesis were adopted in this study. Among them, there were 8 males and 10 females, aged from 43 to 62 years old .Roentgenogramshowed that there were 6 cases of Ⅰ° spondylolisthesis, 11 cases of Ⅱ° and 1 case of Ⅲ°. All patients were treated with cages for intervertebral fusion after total laminectomy and pedicle screws for the reduction. Results The cases were followed up from 6 to 12 months with an average of 11 months. The clinical results were excellent in 13 cases and good in 5 cases. All patients achieved successful fusion and bony union . There were no pedicle screw loosening or broken or peripheral nerve dysfunction in this series. Conclusion This method has been proved to be an effective and reliable procedure for treatment of lumbar spondylolithesis. It produces a high fusion rate and clinical success.

    Release date: Export PDF Favorites Scan
  • THE CLINICAL EFFECTS OF PERCUTANEOUS LUMBAR DISCECTOMY COMBINED WITH SODIUM HYALURONATE IN THE TREATMENT OF LUMBAR INTERVERTEBRAL DISC HERNIATION

    OBJECTIVE To investigate the therapeutic effect of percutaneous lumbar discectomy (PLD) combined with sodium hyaluronate (SH) injection in the treatment of lumbar intervertebral disc herniation. METHODS Forty-eight patients suffered from lumbar disc herniation were divided into two groups and treated by PLD combined with SH injection into epidural cavity (treatment group) or single PLD (control group) respectively. All patients were followed up for 24 months. The therapeutic effects in both groups were assessed and compared according to Macnab’s criterion. RESULTS The patients in the treatment group got much more significant improvement than those in the control group, with shorter therapeutic course and more safety. CONCLUSION PLD combined with SH injection into epidural cavity is more effective and safety in the treatment of lumbar disc herniation than of pure PLD.

    Release date: Export PDF Favorites Scan
  • MODIFIED TRANSFORAMINAL LUMBAR INTERBODY FUSION FOR THE TREATMENT OF LUMBAR DEGENERATIVE DISEASE

    Objective To analyze the cl inical effects of modified transforaminal lumbar interbody fusion (TLIF) for the treatment of lumbar degenerative disease. Methods From October 2003 to December 2006, 33 patients with lumbar degenerative disease (L3-S1) were treated by modified TLIF. There were 14 males and 19 females with an average age of 52.2 years(33 to 70 years). The median disease course was 1.8 years (4 months to 15 years). A total of 42 levels were fused, including 24 cases of single level and 9 cases of double levels. The results of preoperative diagnosis were lumbar degenerative spondylol isthesis with stenosis (8 cases), isthmic spondylol isthesis (5 cases), degenerative lumbar stenosis (16 cases), huge herniated disc with segmental instabil ity (3 cases) and failed back surgery syndrome (1 case). During the modified TLIF procedure, total inferior facet process and inner half summit of superior facet process of TLIF side were resected to make the posterior wall of foramen opened partly. After the bone graft (3 to 5 mL) was placed into the interbody space, a single rectangle Cage was inserted obl iquely from 30° to 40° toward the midl ine. Combined with pedicle screw instrumentation, TLIF was accompl ished. Middle canal and opposite side nerve root decompression were performed simultaneously when necessary. Results Intraoperative dura mater rupture, postoperative cerebral spinal fluid leakage, deep wound infection and transient nerve root stimulation occurredin 1 case respectively, and were all recovered after treatment. No patients had permanent neurologic deficit or aggravation. All patients were followed up for 20 to 58 months (mean 27.2 months). At the follow-up after 1 year postoperatively, all the operated segments achieved fusion standard and no broken screw or Cage dislocation occurred. All 13 cases of spondylol isthesis were reduced thoroughly and maintained satisfactorily. Nineteen patients remained sl ight chronic back pain. There was significant difference (P lt; 0.05) in JOA score between preoperation (14.9 ± 5.1) and postoperation (25.9 ± 3.0). The rate of cl inical improvement was 80.5% (excellent in 24 cases, good in 7 cases, and fair in 2 cases). Conclusion The modified TLIF carries out the less invasive principles in opening operations, simpl ifies the manipulation and expands the indication of TLIF to some extent, and the cl inical results for the treatment of lumbar degenerative disease is satisfactory.

    Release date:2016-09-01 09:07 Export PDF Favorites Scan
  • The Microscopic Imaging Anatomical Study on Measuring Chinese Adult Male Lumbar Isthmus Thickness by Micro CT 3D Reconstruction Technique

    ObjectiveTo measure L1-L5 lumbar isthmus thickness and to construct Chinese adult male lumbar (L1-L5) 3D model by Micro CT 3D reconstruction technique, in order to provide micro-anatomical data for clinical treatment of L1-L5 lumbar spondylolysis. MethodsDry, non-damaged specimens of L1-L5 lumbar isthmus from 60 Chinese adult males were randomly selected from September 2013 to January 2014. Micro CT scanning was carried out, followed by corresponding 3D model construction. The microscopic anatomical parameters such as superior, inferior, inner and outer edge thickness of left and right L1-L5 lumbar isthmus were measured. ResultsL1-L5 lumbar isthmus superior edge thickness was in the order of L1> L2> L3> L5> L4, with the variation ranging from (4.31±0.95) mm to (4.88±0.75) mm. L1-L5 lumbar isthmus inferior edge thickness was in the order of L1< L2< L3< L4< L5, gradually thickened with the variation ranging from (6.03±1.01) mm to (7.27±1.27) mm. L1-L5 lumbar isthmus inner edge thickness amplitude was not obvious, ranging from (6.33±1.21) mm to (6.57±1.27) mm. L1-L5 lumbar isthmus outer edge thickness was in the order of L1< L2< L3< L4< L5, gradually thickened with the variation ranging from (8.44±1.21) mm to (10.27±1.28) mm. ConclusionThere are certain rules within superior, inferior, inner and outer edge thickness of adult L1-L5 lumbar isthmus:the inferior and outer edge thickness of L1-L5 lumbar isthmus gradually becomes thicker, while superior edge gradually becomes thinner. From L1 to L5 lumbar isthmus, the outer edge of the lumbar isthmus is the thickest, followed by inner and inferior edge, and the upper edge is the thinnest.

    Release date: Export PDF Favorites Scan
  • DESIGN AND EXPERIMENTAL STUDY OF INTERNAL FIXATOR FOR THE RECONSTRUCTION OF LUMBAR ISTHMUS

    Objective To investigate the cl inical appl icabil ity and value of internal fixator for the reconstruction of lumbar isthmus in the treatment of lumbar vertebral spondylolysis and to lay a fundation for its cl inical appl ication. Methods Sixteen healthy goats weighing 22.65-31.22 kg were selected to establ ish the models of vertebral spondylolysis at L5, which thereafter were randomized into two groups (n=8): bone graft group in which 0.8-1.1 g fresh autogenous bone was transplanted into the isthmus spondylolysis area, and internal fixation with bone graft group in which internal fixator was installed before transplanting 0.8-1.1 g fresh autogenous bone into the isthmus spondylolysis area. All animals were killed 8 weeks after operation to receive imaging, topographic anatomy and histology detection. Meanwhile, biomechanics test was performed by using 5 donated vertebral body specimens (4 males and 1 female aged 35-51 years old). The left isthmus of L5 vertebra was transected to serve as lumbar vertebral spondylolysis model. A mini-displacement sensor was put at the transected ends of the isthmus. Then loading was conducted with a constant velocity of 2 mm/min by electronic omnipotent tester simulating the direction of fixation force of the internal fixator, and the deformation value of the transected ends was collected by a dynamic data collector and analyzer. The loading wascontinued until the vertebra specimens were damaged. The deformation of displacement sensor and the closure of transected ends of the lumbar isthmus were observed. Results All the goats behaved normally shortly after operation, and no nerve injury induced by operation and no wound infection occurred. Bilaterally obl ique X-ray films of lumbar vertebra and topographic anatomy 8 weeks after operation showed the fusion rate of the internal fixation and bone graft group and the bone graft group was 100% and 62.5%, respectively, indicating there was a significant difference (P lt; 0.05). Histology observation showed 3 goats in the bone graft group presented empty bone trabecula, empty bone lacuna and the disappearance of osteocytes at the transected ends of lumbar isthmus; while in the internal fixation and bone graft group, the bone trabecula grew into cancellous structures with hematopoietic and fatty bone marrow tissue inside, and parts of the bone trabecula had various degrees of mosaic-l ike pattern. During the upload, the biomechanics test and data processing results showed when the external load was 40 N, the deformation of displacement sensor was identified and the gap between the transected ends of lumbar isthmus started to close; then with the increase of external load, the displacement sensor tended to ascend in a l inearity manner; while when the external load was 212 N, the displacement sensor had no further deformation, the gap between the transected ends of lumbar isthmus wascompletely closed, and the pressor effect appeared. Conclusion The internal fixator for the reconstruction of lumbar isthmus has mechanical effects of stabil izing and elevating pressure with a high fusion rate.

    Release date:2016-09-01 09:05 Export PDF Favorites Scan
  • RESEARCH ADVANCEMENT OF LUMBAR INTER-SPINOUS PROCESS NON-FUSION TECHNIQUES

    Objective To elucidate the new development, structural features and appl ication of the lumbar interspinous process non-fusion techniques. Methods With the review of the development course and important research works in the field of the lumbar inter-spinous process non-fusion techniques, the regularity summary, science induction, and prospect were carried out. Results The lumbar inter-spinous process non-fusion technique was a part of non-fusion insertof spinal division posterior surface. According to the design, it could be divided into two major categories: dynamic and static systems. The dynamic system included Coflex and device for intervertebral assisted motion; the static system included X-STOP, ExtenSure and Wall is. The lumbar inter-spinous process non-fusion technique was a new technique of spinal division, it could reserve the integrated function of intervertebral disc and zygapophysial joint, maintain or recover the segmental movement to a normal level, and have no adverse effect on the neighboring segments. A lot of basic and cl inical researches indicated that lumbar inter-spinous process insert had extensive appl ication to curatio retrogression lumbar spinal stenosis, discogenic low back pain, articular process syndrome, lumbar intervertebral disc protrusion and lumbar instabil ity and so on. Conclusion With the matures of lumbar inter-spinous process non-fusion techniques and the increased study of various types of internal fixation devices, it will greatly facil itate the development of treatment of lumbar degenerative disease. But long-term follow-up is needed to investigating the long-term efficacy and perfect operation indication.

    Release date:2016-08-31 05:47 Export PDF Favorites Scan
  • Short-term effectiveness of accurate decompression via foraminoplasty in treatment of lumbar lateral recess stenosis

    Objective To discuss the effectiveness and the safety of accurate decompression via foraminoplasty in treating lumbar lateral recess stenosis patients who accompanied by disk-flavum ligamentum space and bony lateral recess stenosis, and to analysis the short-term effectiveness of the surgical procedures. Methods Forty-five lumbar lateral recess stenosis patients accompanied by disk-flavum ligamentum space and bony lateral recess stenosis were treated by accurate decompression via foraminoplasty between January 2013 and January 2016. There were 29 males and 16 females with a median age of 58 years (range, 42-82 years). The disease duration was 3-96 months (mean, 24.4 months). The lesion segment included L4, 5 in 36 cases and L5, S1 in 9 cases. The visual analogue scale (VAS) score of low back pain and leg pain at preoperation and last follow-up were recorded, and the modified Macnab criteria was used to evaluate the effectiveness at last follow-up. Postoperative CT and MRI were reviewed to evaluate the stability and decompression of the lumbar spine. Results All operations were successfully completed. All the 45 patients were followed up 3-18 months (median, 11 months). Dural tear occurred in 2 cases during operation, bone graft removed into the spinal canal in 1 case, postoperative low back pain occurred in 5 cases, and there was no nerve root injury, hematoma formation, or other complications. The leg pain VAS score at last follow-up (0.6±1.2) was significantly improved when compared with preoperative score (5.7±1.4) (t=8.981, P=0.001); and the low back pain VAS scores showed no significant difference between preoperation and last follow-up (1.5±1.3vs. 1.7±1.4;t=0.535, P=0.585). According to the modified Macnab criteria, the results were excellent in 20 cases, good in 22 cases, fair in 2 cases, and poor in 1 case at last follow-up, and the excellent and good rate was 93.3%. Conclusion Accurate decompression via foraminoplasty is an effective, safe, and less invasive way for treating lumbar recess stenosis patients accompanied by disk-flavum ligamentum space and bony lateral recess stenosis.

    Release date:2017-11-09 10:16 Export PDF Favorites Scan
  • CLINICAL APPLICATION OF POSTERIOR DYNAMIC STABILIZATION DEVICE

    Objective To review the current development of the dynamic stabilization devices and their biomechanics as well as clinical application.Methods The related biomedical research papers at home and abroad were consulted and analyzed Results There were obvious advances in the theoretic foundation and the clinical application in treatment of the degenerative lumbar disorders with the dynamic stabilization devices, especially with the nonfusion dynamic stabilization devices. Conclusion The effectiveness of the dynamic stabilization devices have attracted more and more biomedical researchers, especially the posterior dynamic stabilization device, which has provided a new approach to treatment of the degenerative lumbar disorders.

    Release date:2016-09-01 09:20 Export PDF Favorites Scan
  • EVALUATION OF TWO-DIMENSION COMPUTER-AIDED SURGERY NAVIGATION SYSTEM FOR LUMBAR PEDICLE SCREW FIXATION ON RECOMBINANT CT SECTION AFTER OPERATION

    ObjectiveTo investigate the accuracy of the two-dimension computer-aided surgery navigation system in the lumbar pedicle screw fixation on recombinant CT section after operation. MethodsBetween February 2011 and April 2013, 218 patients undergoing lumbar spinal pedicle screw fixation were divided into 2 groups:two-dimension computer-aided surgery navigation system was used in 95 cases (the navigation group) and X-ray fluoroscopy assistant technology in 123 cases (the fluoroscopy assistant group). There was no significant difference in age, gender, and type of disease between 2 groups (P>0.05). The mean operating time, blood loss volume, and fluoroscopy times, and the one-time success rate of pedicle screw implant were observed. The sagittal screw angle (SSA), the relationship between the pedicle cortex and screw, the accuracy rate of pedicle screw, and the sagittal angle on both sides (SBA) were observed. ResultsA total of 504 screws were inserted in navigation group, 432 (85.7%) were inserted successfully at first time and 472 (85.7%) were inserted successfully at end time. A total of 656 screws were inserted in fluoroscopy assistant group, 474 (72.3%) were successfully inserted at first time, and 563 (85.8%) were inserted successfully at end time. There were significant differences in the one-time success rate and final success rate of pedicle screw implant between 2 groups (χ2=30.19, P=0.00; χ2=18.16, P=0.00). There was no significant difference in the mean operating time and the blood loss volume of pedicle screw implant between 2 groups (t=0.88, P=0.38; t=1.47, P=0.14); but the fluoroscopy times of pedicle screw implant in navigation group 0.7±0.3 were significantly less than that in fluoroscopy assistant group 1.5±1.0 (t=-8.09, P=0.00). The SSA and SBA in navigation group[(3.7±0.9)° and (1.7±0.8)°] were significantly less than those in fluoroscopy assistant group[(6.0±1.7)° and (3.5±1.6)°] (t=-26.92, P=0.00; t=-22.49, P=0.00). ConclusionThe sagittal screw angle and accuracy of pedicle screw implant can be significantly improved using the two-dimension computer-aided surgery navigation system in lumbar posterior fixation.

    Release date: Export PDF Favorites Scan
  • RESEARCH PROGRESS OF STRESS FRACTURE OF LUMBAR PEDICLE

    Objective To review the research progress of stress fracture of the lumbar pedicle. Methods The literature about the stress fracture of the lumbar pedicle was reviewed extensively and summarized. Results There are two types of stress fracture: fatigue and structure insufficient. Stress fracture of lumbar pedicle occurred mainly in the crowd with repetitive and large activities of spine, contralateral spondylolysis, or previous surgery of lumbar vertebra. The main stresses causing stress fracture of the lumbar pedicle are shear stress and twisting stress, followed by sudden hyperflexion or hyperextension of the spine. Stress fracture of lumbar pedicle was easily missed by conventional X-ray examination, usually XCT, MRI, or bone scan was needed to confirm the diagnosis. It is divided into 4 types or 4 periods according to MRI findings: stress reaction, incomplete fracture, complete fracture, and pseudarthrosis. For patients with incomplete, complete, and juvenile stress fractures of the lumbar pedicle without nerve root irritation, the majority of claims preferred conservative treatment and the healing rate of fracture was high; for patients with bilateral pseudarthrosis and with nerve root irritation as well as patients who failed to the conservative treatment, surgical management was advocated and the operation result is good. Conclusion Stress fracture of the lumbar pedicle as one of the causes of low back pain is extremely rare, and is easily missed clinically. Surgery or conservative management should be selected based on type of fracture and specific condition of the patient, the treatment results are satisfactory.

    Release date:2016-08-31 04:06 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content