west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "algorithm" 70 results
  • An improved peak extraction method for heart rate estimation

    In order to solve imperfection of heart rate extraction by method of traditional ballistocardiogram (BCG), this paper proposes an improved method for detecting heart rate by BCG. First, weak cardiac activity signals are acquired in real time by embedded sensors. Local BCG beats are obtained by signal filtering and signal conversion. Second, the heart rate is estimated directly from the BCG beat without the use of a heartbeat template. Compared with other methods, the proposed method has strong advantages in heart rate data accuracy and anti-interference, and it also realizes non-contact online detection. Finally, by analyzing the data of more than 20,000 heart rates of 13 subjects, the average beat error was 0.86% and the coverage was 96.71%. It provides a new way to estimate heart rate for hospital clinical and home care.

    Release date:2019-12-17 10:44 Export PDF Favorites Scan
  • Drug-target protein interaction prediction based on AdaBoost algorithm

    The drug-target protein interaction prediction can be used for the discovery of new drug effects. Recent studies often focus on the prediction of an independent matrix filling algorithm, which apply a single algorithm to predict the drug-target protein interaction. The single-model matrix-filling algorithms have low accuracy, so it is difficult to obtain satisfactory results in the prediction of drug-target protein interaction. AdaBoost algorithm is a strong multiple classifier combination framework, which is proved by the past researches in classification applications. The drug-target interaction prediction is a matrix filling problem. Therefore, we need to adjust the matrix filling problem to a classification problem before predicting the interaction among drug-target protein. We make full use of the AdaBoost algorithm framework to integrate several weak classifiers to improve performance and make accurate prediction of drug-target protein interaction. Experimental results based on the metric datasets show that our algorithm outperforms the other state-of-the-art approaches and classical methods in accuracy. Our algorithm can overcome the limitations of the single algorithm based on machine learning method, exploit the hidden factors better and improve the accuracy of prediction effectively.

    Release date:2019-02-18 02:31 Export PDF Favorites Scan
  • Detection study of walking segments of children with cerebral-palsy based on surface electromyographic signals

    In this study, surface electromyography (sEMG) of the lower limbs of cerebral-palsy (CP) subjects in gait cycle was recorded and its parameters of gait cycle characters were analyzed to assess their clinical severity. Three algorithms, including integrated profile (IP), sample-entropy (SampEN) and smooth nonlinear energy operator (SNEO) algorithm, were applied to calculate the duration of walking sEMG segments in simulated SEMG signals. After that, the efficiency and accuracy were compared among these three algorithms. SNEO was then selected as the optimal algorithm among the three algorithms and employed for real sEMG signal processing of CP subjects. The results indicated that there was no significant difference in the accuracy of sEMG segement detection for the three algorithms. However, the computation speed of SNEO algorithm was much faster than those of the others and thus it was a suitable algorithm for detecting walking sEMG segments of CP subjects. In addition, the positive correlation was found between the clinical severity and the mean duration of walking sEMG segments in CP subjects. The results indicated that there was a significant difference in the three groups of CP subjects with different levels of severity. Our findings showed that the mean duration of walking sEMG segments could be considered as an assistant index to evaluate the clinical severity of CP subjects.

    Release date:2017-06-19 03:24 Export PDF Favorites Scan
  • Research on Optimization of Lower Limb Parameters of Cardiopulmonary Resuscitation Simulation Model Based on Genetic Algorithm

    Sudden cardiac arrest is one of the critical clinical syndromes in emergency situations. A cardiopulmonary resuscitation (CPR) is a necessary curing means for those patients with sudden cardiac arrest. In order to simulate effectively the hemodynamic effects of human under AEI-CPR, which is active compression-decompression CPR coupled with enhanced external counter-pulsation and inspiratory impedance threshold valve, and research physiological parameters of each part of lower limbs in more detail, a CPR simulation model established by Babbs was refined. The part of lower limbs was divided into iliac, thigh and calf, which had 15 physiological parameters. Then, these 15 physiological parameters based on genetic algorithm were optimized, and ideal simulation results were obtained finally.

    Release date: Export PDF Favorites Scan
  • Cool-tip Radiofrequency Ablation Therapy Instrument Based on Impedance Control Algorithm

    A new cool-tip radiofrequency (RF) ablation therapeutic instrument based on impedance control algorithm is introduced in this paper. The equipment is composed of hardware system and software system. The RF power output and real time data acquisition are completed by the hardware system, while the software is used mainly to finish the control of the ablation range, the core of which is impedance control algorithm, and it also used to complete the display of the real time data in the course of the experiment. The impedance algorithm has solved the problem of impedance increased rapidly during the RF ablation, which has also expanded the scope of ablation. The pig liver experiments showed that the impedance control algorithm had strong adaptability. It also obtained a result of ablation range up to 3.5~4.5 cm single needle. It has the high clinical practical value of one-time inactivation of 3~5 cm tumor.

    Release date: Export PDF Favorites Scan
  • A multifrequency time-difference electrical impedance tomography algorithm using spectral constraints

    This study aims to propose a multifrequency time-difference algorithm using spectral constraints. Based on the knowledge of tissue spectrum in the imaging domain, the fraction model was used in conjunction with the finite element method (FEM) to approximate a conductivity distribution. Then a frequency independent parameter (volume or area fraction change) was reconstructed which made it possible to simultaneously employ multifrequency time-difference boundary voltage data and then reduce the degrees of freedom of the reconstruction problem. Furthermore, this will alleviate the illness of the EIT inverse problem and lead to a better reconstruction result. The numerical validation results suggested that the proposed time-difference fraction reconstruction algorithm behaved better than traditional damped least squares algorithm (DLS) especially in the noise suppression capability. Moreover, under the condition of low signal-to-noise ratio, the proposed algorithm had a more obvious advantage in reconstructions of targets shape and position. This algorithm provides an efficient way to simultaneously utilize multifrequency measurement data for time-difference EIT, and leads to a more accurate reconstruction result. It may show us a new direction for the development of time-difference EIT algorithms in the case that the tissue spectrums are known.

    Release date:2020-04-18 10:01 Export PDF Favorites Scan
  • Non-contact Heart Rate Estimation Based on Joint Approximate Diagonalization of Eigenmatrices Algorithm

    Based on the imaging photoplethysmography (iPPG) and blind source separation (BSS) theory the author put forward a method for non-contact heartbeat frequency estimation. Using the recorded video images of the human face in the ambient light with Webcam, we detected the human face through software, separated the detected facial image into three channels RGB components. And then preprocesses i.e. normalization, whitening, etc. were carried out to a certain number of RGB data. After the independent component analysis (ICA) theory and joint approximate diagonalization of eigenmatrices (JADE) algorithm were applied, we estimated the frequency of heart rate through spectrum analysis. Taking advantage of the consistency of Bland-Altman theory analysis and the commercial Pulse Oximetry Sensor test results, the root mean square error of the algorithm result was calculated as 2.06 beat/min. It indicated that the algorithm could realize the non-contact measurement of heart rate and lay the foundation for the remote and non-contact measurement of multi-parameter physiological measurements.

    Release date: Export PDF Favorites Scan
  • Recognition of high-frequency steady-state visual evoked potential for brain-computer interface

    Coding with high-frequency stimuli could alleviate the visual fatigue of users generated by the brain-computer interface (BCI) based on steady-state visual evoked potential (SSVEP). It would improve the comfort and safety of the system and has promising applications. However, most of the current advanced SSVEP decoding algorithms were compared and verified on low-frequency SSVEP datasets, and their recognition performance on high-frequency SSVEPs was still unknown. To address the aforementioned issue, electroencephalogram (EEG) data from 20 subjects were collected utilizing a high-frequency SSVEP paradigm. Then, the state-of-the-art SSVEP algorithms were compared, including 2 canonical correlation analysis algorithms, 3 task-related component analysis algorithms, and 1 task discriminant component analysis algorithm. The results indicated that they all could effectively decode high-frequency SSVEPs. Besides, there were differences in the classification performance and algorithms' speed under different conditions. This paper provides a basis for the selection of algorithms for high-frequency SSVEP-BCI, demonstrating its potential utility in developing user-friendly BCI.

    Release date: Export PDF Favorites Scan
  • Design and implementation of a modular pulse wave preprocessing and analysis system based on a new detection algorithm

    As one of the standard electrophysiological signals in the human body, the photoplethysmography contains detailed information about the blood microcirculation and has been commonly used in various medical scenarios, where the accurate detection of the pulse waveform and quantification of its morphological characteristics are essential steps. In this paper, a modular pulse wave preprocessing and analysis system is developed based on the principles of design patterns. The system designs each part of the preprocessing and analysis process as independent functional modules to be compatible and reusable. In addition, the detection process of the pulse waveform is improved, and a new waveform detection algorithm composed of screening-checking-deciding is proposed. It is verified that the algorithm has a practical design for each module, high accuracy of waveform recognition and high anti-interference capability. The modular pulse wave preprocessing and analysis software system developed in this paper can meet the individual preprocessing requirements for various pulse wave application studies under different platforms. The proposed novel algorithm with high accuracy also provides a new idea for the pulse wave analysis process.

    Release date:2023-08-23 02:45 Export PDF Favorites Scan
  • Stress analysis of the molar with the all-ceramic crown prosthesis based on centric occlusal optimization

    Stress distribution of denture is an important criterion to evaluate the reasonableness of technological parameters, and the bite force derived from the antagonist is the critical load condition for the calculation of stress distribution. In order to improve the accuracy of stress distribution as much as possible, all-ceramic crown of the mandibular first molar with centric occlusion was taken as the research object, and a bite force loading method reflecting the actual occlusal situation was adopted. Firstly, raster scanning and three dimensional reconstruction of the occlusal surface of molars in the standard dental model were carried out. Meanwhile, the surface modeling of the bonding surface was carried out according to the preparation process. Secondly, the parametric occlusal analysis program was developed with the help of OFA function library, and the genetic algorithm was used to optimize the mandibular centric position. Finally, both the optimized case of the mesh model based on the results of occlusal optimization and the referenced case according to the cusp-fossa contact characteristics were designed. The stress distribution was analyzed and compared by using Abaqus software. The results showed that the genetic algorithm was suitable for solving the occlusal optimization problem. Compared with the reference case, the optimized case had smaller maximum stress and more uniform stress distribution characteristics. The proposed method further improves the stress accuracy of the prosthesis in the finite element model. Also, it provides a new idea for stress analysis of other joints in human body.

    Release date:2020-12-14 05:08 Export PDF Favorites Scan
7 pages Previous 1 2 3 ... 7 Next

Format

Content