ObjectiveTo explore the effect of the reimplantation procedure with the De Paulis Valsalva graft in patients with aneurysms. MethodsWe retrospectively analyzed the clinical data of 38 patients underwent valve-sparing aortic root replacement using De Paulis graft in our hospital between September 2005 and July 2013.There were 32 male and 6 female patients at age of 45.5±12.4 years. We compared the parameters of pre-operation and post-operation and followed up the patients for 5 years. ResultsThere were 2(5.3%) deaths in hospital. The follow-up time was 2-95 months with following-up rate of 92.1%(35/38). A total of 2 patients(5.3%) had grade 3 to grade 4 aortic insufficiency. And one of these patients received aortic valve replacement after 1 year. At 5 years of following-up, one patient died of septic shock due to pacemaker infection. One patient died of kidney failure due to renal artery dissection aneurysm affected with impaired renal function and long-term hemodialysis. ConclusionThe reimplantation type of valve-sparing procedure can be facilitated by the use of the De Paulis valsalva graft and can be performed with satisfactory perioperative and mid-term results.
This study aims to explore the effect of aortic sinus diameter on aortic valve opening and closing performance in the case of no obvious disease of aortic valve and annulus and continuous dilation of aortic root. A total of 25 three-dimensional aortic root models with different aortic sinus and root diameters were constructed according to the size of clinical surgical guidance. The valve sinus diameter DS is set to 32, 36, 40, 44 and 48 mm, respectively, and the aortic root diameter DA is set to 26, 27, 28, 29 and 30 mm, respectively. Through the structural mechanics calculation with the finite element software, the maximum stress, valve orifice area, contact force and other parameters of the model are analyzed to evaluate the valve opening and closing performance under the dilated state. The study found that aortic valve stenosis occurs when the DS = 32 mm, DA = 26, 27 mm and DS = 36 mm, DA = 26 mm. Aortic regurgitation occurs when the DS = 32, 36 and 40 mm, DA = 30 mm and DS = 44, 48 mm, DA = 29, 30 mm. The other 15 models had normal valve movement. The results showed that the size of the aortic sinus affected the opening and closing performance of the aortic valve. The smaller sinus diameter adapted with the larger root diameter and the larger sinus diameter adapted with the smaller root diameter. When the sinus diameter is 40 mm, the mechanical performance of the valve are good and it can well adapt with the relatively large range of aortic root dilation.
ObjectiveTo investigate and evaluate the safety and efficacy of Bentall operation in the reoperation of patients with small aortic root or annulus.MethodsBentall procedure was performed in 24 patients with small aortic root or annulus in our hospital from September 2014 to December 2019. There were 18 males and 6 females with a mean age of 31-68 (45.70±15.27) years. All patients had undergone a previous replacement of the aortic valve including 20 patients receiving valve replacement, 2 patients aortic root replacement with a valved conduit and 2 patients bioprothesis replacement.ResultsThere was no early death in hospital and one death during the 30-day postoperative period. Re-thoracotomy due to bleeding was necessary in only 2 patients and no bleeding was related to the proximal anastomosis of the conduit. One patient performed pacemaker implantation for heart block after the procedure. The mean sizes of implanted aortic valve prosthesis were 22.75±1.78 mm. A mean gradient across the aortic valve prostheses in the postoperative echocardiographic examination was 11.17±2.24 mm Hg.ConclusionBentall procedure is safe and allows a larger size of prosthesis implantation in patients with small aortic annulus or root after previous aortic valve or complete root replacement, resulting in good postoperative hemodynamic characteristics and short-term clinical results.
Objective To analyze the clinical effect of partial aortic root remodeling for root reconstruction on Stanford type A aortic dissection. Methods From January 2010 to December 2015, 30 patients (25 males, 5 females) underwent partial aortic root remodeling for root reconstruction on Stanford type A aortic dissection with involvement of aortic root. The range of age was from 27 to 72 years, and the mean age was 51.2±8.0 years. The proximal aortic dissection received partial aortic root remodeling, and the operation procedures included partial aortic root remodeling+ascending aortic replacement in 9 patients, partial aortic root remodeling+ascending aortic replacement+hemi-arch replacement in 6 patients, partial aortic root remodeling+ascending aortic replacement+Sun's procedure in 15 patients. The patients were followed up for 10 to 60 months with a mean of 37.9±3.2 months. Preoperative and postoperative degrees of aortic regurgitation were compared. Results All patients survived from the operation, and one patient died from severe pulmonary infection 15 days after operation. The overall survival rate was 96.7% (29/30). One patient died during the follow-up. Two patients underwent aortic valve replacement in the 12th and 15th postoperative month respectively because of severe aortic regurgitation (AI). Up to the last follow-up, trivial or no aortic regurgitation was demonstrated in 24 patients, but mild aortic regurgitation occurred in 2 patients. Conclusion The surgical treatment for aortic root pathology due to Stanford type A aortic dissection is challenging, and partial aortic root remodeling operations could restore valve durability and function, and obtains the early- and mid-term results.
ObjectiveTo assess outcomes of transcatheter aortic valve replacement (TAVR) for pure native aortic valve regurgitation.MethodsA total of 129 patients underwent transfemoral TAVR in Fuwai Hospital from May 2019 to October 2020 were retrospectively analyzed. There were 83 males and 46 females with an average age of 72.26±8.97 years. The patients were divided into a pure native aortic valve regurgitation group (17 patients) and an aortic valve stenosis group (112 patients).ResultsThe incidence of valve in valve was higher in the pure native aortic valve regurgitation group (47.0% vs. 16.1%, P<0.01). There was no statistical difference between the two groups in conversion to surgery, intraoperative use of extracorporeal circulation, intraoperative left ventricular rupture, postoperative use of extracorporeal membrane oxygenation (ECMO), peripheral vascular complications, disabled stroke, death, or pacemaker implantation. There was no statistical difference in the diameter of annulus (25.75±2.21 mm vs. 24.70±2.90 mm, P=0.068) or diameter of outflow tract (25.82±3.75 mm vs. 25.37±3.92 mm, P=0.514) between the pure native aortic valve regurgitation group and the aortic valve stenosis group.ConclusionTransfemoral TAVR is a feasible method for patients with pure native aortic valve regurgitation. The diameter of annulus plane, the diameter of outflow tract and the shape of outflow tract should be evaluated.
ObjectiveTo evaluate the midterm effect of valve-sparing aortic root replacement (VSRR) on aortic root aneurysm and moderate to severe aortic regurgitation (AR). MethodsThe clinical data of patients with aortic root aneurysm and moderate to severe AR undergoing VSRR and surviving from the operation from October 2013 to May 2020 were retrospectively analyzed. There were 31 males and 9 females, with an average age of 47.1±13.4 years. There were 30 patients with true aneurysm of aortic root and 10 patients with dissecting aneurysm of aortic root. There were 3 patients with bicuspid aortic valve, and 12 patients with Marfan syndrome. The AR measured by the echocardiogram was moderate in 18 patients and severe in 22 patients. The average diameter of aortic annulus was 27.0±3.9 mm, and the mean largest diameter of aortic sinus was 52.3±6.1 mm. ResultsA total of 32 patients underwent David technique and 8 patients underwent Yacoub technique, and 10 patients underwent aortic cusp repair simultaneously. All 40 patients completed the follow-up, and the follow-up period was 12-86 (45.7±18.9) months. During the period, 1 patient died of heart failure, 2 had reoperation due to new-onset Stanford B aortic dissection, and no patients had reoperation related to aortic valve. The postoperative New York Heart Association cardiac function classification (1.6±0.5 vs. 2.8±0.8), left ventricular end-diastolic dimension (52.2±7.8 mm vs. 61.4±10.6 mm) and left ventricular end-diastolic volume (136.0±58.8 mL vs. 193.3±83.9 mL) of the patients were significantly improved compared with preoperative ones (P<0.05). By echocardiography, 19 patients had no AR, 18 patients had mild AR, 3 patients had mild-moderate AR, and no patients had moderate or higher AR. ConclusionIn patients with aortic root aneurysm and moderate to severe AR, VSRR technique avoids prosthetic valves and anticoagulation-related complications, has lower rate of AR recurrence and reoperation, and improves the quality of life in the midterm period.
Objective To observe the intermediate-term outcome and heart function in patients with small aortic root,and to investigate the feasi bility of small size prosthesis. Methods From July 1990 to Jun e 2003, 62 patients underwent 19mm aortic valve prosthesis(19mm group). The resu lts were compaired with other 62 patients receiving larger prosthesis(≥21 mm,21 mm group). Clinical symptoms, signs, electrocardiogram(ECG) and echocardiogr a phy (UCG) were followedup, KaplanMeier survival curve was used for analysis. Results In 19mm group, there were 38 patients with ≥Ⅱ/Ⅵ grade systolic murmur in aortic valve area,18 patients with ECG ST segm ent change and 11 patients with chest pain and/or chest distress. Postoperative cardiac function showed that 33 patients with heart function New York Heart Ass ociation(NYHA) class Ⅱ and 29 patients with NYHA class Ⅲ. Postoperative ECG sh owed in 21mm group,6 patients with ECG ST segment change,3 patients with chest distress and 6 patients with occasional chest pain and there were 48 patients with NYHA class Ⅱ and 14 patients with NYHA class Ⅲ,there was statis tically difference in heart function between two groups(P=0.020). Th ere was a significant regression of left ventricular end diastolic diameter(LVEDD),left ventricular wall thickness, mass index,and pressure gradients in both groups(P<0.05), and left ventricular ejection f raction (LVEF)had a significant increase in patients 5 years after operation tha n that before operation(P<0.05), and there was no statistically differenc e in both groups(P>0.05). Actual survival at 1,5 years were 93.5%,74 .2% in 19mm group compared with 95.2%,790% in the 21mm valve group, there were no statistically difference in both groups (P=0.231,0.110). Conc lus ion Patients with 19mm prosthetic aortic valves can experience a satisf actory improvement and get excellent intermediate-term survival.
Objective To analyze the early prognosis of repairing adult aortic insufficiency with the Florida sleeve procedure. Methods The patients with aortic insufficiency who underwent Florida sleeve repair in the Nanjing First Hospital, Nanjing Medical University between August 2020 and May 2024 were selected. Their general data, perioperative conditions, and echocardiographic data before, during, and after the procedure and at follow-up were analyzed. Results Fifteen patients were included, consisting of 12 males and 3 females, aged 33-71 (53.5±12.4) years. Preoperative echocardiography indicated that there was 1 patient of rheumatic disease, 7 patients of degenerative disease, 4 patients secondary to aortic aneurysm, and 3 patients of bicuspid aortic valve. The severity distribution included 2 patients of severe insufficiency, 4 patients of moderate-to-severe insufficiency, 5 patients of moderate insufficiency, and 4 patients of mild-to-moderate insufficiency. The mean cardiopulmonary bypass time was (135.0±40.0) minutes, the aortic cross-clamp time was (109.9±38.6) minutes, and the median ICU stay was 1.0 day. No mortality was recorded within 30 days postoperatively. Follow-up echocardiography showed that the valve regurgitation, left ventricular end-diastolic diameter, left ventricular end-systolic diameter, and sinus diameter all achieved the desired outcomes. Conclusion Florida sleeve repair for aortic valve in patients with a sinus diameter less than 50 mm not only effectively improves hemodynamics in adults with aortic insufficiency, but also has the advantages of low surgical risk and rapid postoperative recovery, making it a promising procedure for clinical application.
Objective To investigate and evaluate the safety and efficacy of the aortic-mitral annular enlargement technique (double annular enlargement) in patients with small-size valve prostheses after prior valve surgery. MethodsThe clinical data of patients who underwent double valve annular enlargement in Wuhan Asia Heart Hospital from April 2020 to April 2022 were retrospectively analyzed. Results A total of 30 patients were collected, including 2 males and 28 females aged 9-78 (52.71±3.53) years. All patients had previous heart valve surgery, including 1 patient receiving the third heart surgery. All patients were operated on successfully and there were no postoperative in-hospital deaths. There was no postoperative bleeding which needed a secondary open-chest hemostasis, and one patient underwent permanent pacemaker implantation due to postoperative sick sinus syndrome. The mean diameter of the implanted prosthetic aortic valve was 24.23±1.60 mm, which was significantly larger than that of the preoperative aortic valve (21.03±1.90 mm, P<0.001). The mean diameter of the implanted prosthetic mitral valve was 28.33±1.21 mm, which was significantly larger than that of the preoperative mitral valve (25.43±0.84 mm, P<0.001). The mean peak gradient difference across the prosthetic aortic valve on postoperative echocardiography was 18.17±6.44 mm Hg, which was significantly lower than that of the preoperative aortic valve (82.57±24.48 mm Hg, P<0.001). The mean peak gradient difference of the postoperative prosthetic mitral valve was 12.73±5.45 mm Hg, which was significantly lower than that of the preoperative mitral valve (19.43±8.97 mm Hg, P=0.003). Conclusion The double annular enlargement technique is safe and effective for reoperation in patients with a history of valve surgery with a small aortic root to obtain both a larger size prosthetic valve for a larger orifice area and stability of the mitral-aortic valve union, resulting in good postoperative hemodynamic characteristics and clinical outcomes.
Objective To evaluate the early clinical effect of reimplantation in the treatment of bicuspid aortic valve (BAV) with aortic root aneurysm. Methods The clinical data of 25 patients with BAV and aortic root aneurysm[mean diameter: 45-63 (52.68±5.55) mm] undergoing reimplantation in West China Hospital from November 2019 to May 2021 were retrospectively reviewed. There were 22 males and 3 females. The mean age was 15-65 (50.00±13.10) years and body surface area was 1.79±0.23 m2. ResultsThe pathological classification of BAV malformation was confirmed during the operation: Type 0 in 3 patients and Type 1 in 22 patients. There were 12 patients undergoing cusp central plication, and 2 patients were sutured with a closed fusion crest. Postoperative valve leaflet coaptation height was 0.78±0.15 cm, and effective height was 1.27±0.19 cm. In operation, maximum aortic valve flow velocity was 1.65±0.42 m/s, pressure difference was 5.46±3.05 mm Hg, and aortic valve annulus diameter was 21.32±0.95 mm. Cardiopulmonary bypass time was 225.84±35.34 min, and aortic block time was 189.60±26.51 min. In-hospital time was 11.64±3.07 d, ICU stay time was 2.64±0.99 d, and mechanical ventilation time was 1.48±0.87 d. The follow-up time was 17.20±4.70 months, and no death or major complications occurred during the follow-up in all patients. The cardiac function of the patients significantly improved postoperatively (P≤0.05). Echocardiography suggested that 12 patients had no aortic regurgitation, 10 minor aortic regurgitation, 3 mild aortic regurgitation, and no patients with moderate or more severe regurgitation. The diameter of the aortic sinus, left ventricular end-diastolic diameter and volume decreased during the follow-up, compared to preoperative ones (P≤0.05). The maximum flow velocity of the aortic valve was 1.54±0.36 m/s, and the pressure difference was 5.17±2.38 mm Hg during the follow-up. ConclusionReimplantation technology has a good clinical effect for highly selective BAV patients. It can effectively avoid long-term postoperative anticoagulation, but the maximum flow rate after surgery is slightly increased, which may be related to the configuration of BAV itself. While compared with valve replacement, the effect is still worthy of recognition.