Objective To analyze the influence of COPD on the structure and function of left ventricular. Methods Sixty-nine COPD patients ( mean age: 69. 0 ±7. 8 yrs) and forty healthy controls ( mean age: 67. 8 ±7. 6 yrs) were enrolled in this study. Both groups underwent Doppler echocardiography.Heart rate ( HR) were recorded. Left ventricular end-diastolic volume ( LVEDV) , left ventricular enddiastolic diameter ( LVEDD) , interventricular septum( IVS) , stroke volume ( SV) , and cardiac output ( CO)were measured. The changes of left ventricular were compared between the COPD patients and the healthy controls, and also between the COPD patients with or without chronic cor pulmonale. Results Compared with the healthy controls, movement range of IVS, LVEDD, LVEDV, and SV reduced significantly ( P lt;0. 05) , and HR raised significantly in the COPD patients ( P lt; 0. 05) . CO had no significant difference between two groups ( P gt;0. 05) . Sub-group analysis indicated that the thickness and movement range of IVSwere greater in the patients with cor pulmonale secondary to COPD than those without cor pulmonale ( P lt;0. 05) . Conclusions In COPD patients, left ventricular chamber size decreases, and left ventricular systolic function is impaired. Left ventricular function is impaired more severe in cor pulmonale secondary to COPD than COPD without cor pulmonale.
Objective To evaluate the effectiveness of multiple small-diameter drilling decompression combined with hip arthroscopy for early oeteonecrosis of the femoral head (ONFH). Methods Between March 2010 and December 2013, 91 patients with early ONFH were treated with the operation of multiple small-diameter drilling decompression combined with hip arthroscopy in 39 cases (53 hips, group A) or with drilling decompression alone in 52 cases (74 hips, group B). The patients in 2 groups had obvious hip pain and limited motion before operation. There was no significant difference in gender, age, etiology, effected side, stage of osteonecrosis, and preoperative Harris score between 2 groups (P>0.05). Results All operations succeeded and all incisions healed by first intention. The operation time was significantly longer in group A [(73.3±10.6) minutes] than in group B [(41.5±7.2) minutes] (t=8.726, P=0.000). Temporary of sciatic nerve apraxia after operation occurred in 2 patients of group A, and no complication occurred in other patients. Patients were followed up 24-52 months (mean, 39.3 months) in group A and 24-48 months (mean, 34.6 months) in group B. At last follow-up, the Harris scores were 83.34±8.76 in group A and 76.61±9.22 in group B, showing significant differences when compared between 2 groups (t=–4.247, P=0.029) and when compared with preoperative values in 2 groups (t=–10.327, P=0.001; t=–8.216, P=0.008). X-ray films showed that the collapse of the femoral head was observed in 6 hips (1 hip at stage Ⅰand 5 hips at stage Ⅱ) in group A, and in 16 hips (4 hips at stageⅠand 12 hips at stage Ⅱ) in group B; and hip arthroplasty was performed. The total effective rates were 88.68% (47/53) in group A and 78.38% (58/74) in group B, respectively; showing significant difference between 2 groups (χ2=5.241, P=0.041). Conclusion Multiple small-diameter drilling decompression combined with hip arthroscopy is effective in pain relief, improvement of hip function, slowing-down the process of femoral head necrosis, delaying the need for total hip arthroplasty in patients with early ONFH.
Objective To study the effect of preparation conditions for small-diameter polyurethane(PU) vascular graft on microstructure and mechanical properties. Methods The small-diameter microporous PU artificial vascular grafts were prepared by dipping and leaching method. The dimension and microstructure were controlled by changing mold diameter, PU materials, salt sizes, salt to polymer ratio, times of dipping layers etc. The mechanical properties of PU grafts including radical compliance, water permeability, longitudinal strength, burst strength, and suture tearing strength were measured and the effect of the graft dimension and microstructure on their properties were studied. Results The internal diameter of grafts prepared was 2-4 mm depending on mold diameter. The wall thickness was 0.6-1.2 mmafter dipping 4-8 layers. The density was 0.23-0.49 g/cm3. The pore was 42-95 μm in diameter. The porosity was 56%80%. The radical compliance was 1.2%-7.4%·13.3 kPa-1 and higher compliances could be obtained by using moreelastic polyurethane, higher salt to polymer ratio, longer diameter and less wall thickness. The water permeability, mainly depending on salt to polymer ratio,diameter, and wall thickness, was 0.29-12.44 g/(cm2·min). The longitudinal strength was 1.55-4.36 MPa correlating with tensile strength of polyurethane and salt to polymer ratio. The burst strength was 60-300 kPa also depending on tensile strength of polyurethane and salt to polymer ratio. The suture tearing strength was 19.5-96.2 N/cm2 depending on tensile strength of polyurethanebut not on the angle of tearing and graft axial directions. The compliance and water permeability of Chronoflex grafts were higher than those of PCU1500 grafts, but longitudinal strength, burst strength, and suture tearing strength of PCU1500 grafts were better than those of Chronoflex grafts. Conclusion Small-diameter grafts with proper pore sizes, porosity, matching compliance can be obtained by selecting PU materials and optimizing the preparation conditions.
ObjectiveTo explore the risk factors for tracheal stenosis caused by tracheotomy or intubation.MethodsFrom July 2010 to July 2020, a total of 44 patients were suffered with tracheal stenosis caused by tracheotomy or intubation at the First Affiliated Hospital of Hunan Normal University as case group (n=44), and 34 patients were suffered tracheotomy or intubation without tracheal stenosis as control group (n=34). The clinical application of intratracheal tube cuff diameter was investigated by univariate comparison, ROC analysis and multivariate logistic regression analysis.ResultsUnivariate analysis showed intratracheal tube cuff diameter (C)/transverse diameter at the level of the clavicle >150%, intubation time>7d, tracheal intubations/tracheostomy ≥2, recurrent respiratory tract infections and replacement of tracheal tube≥ 2 were the influence factors of posttracheostomy tracheal stenosis (PTTS) and postintubation tracheal stenosis (PITS) (P<0.005). Multivariate Logistic regression analysis showed C/T>150% (OR=6.681, 95%CI: 1.164 - 38.363), intubation time>7d (OR=4.723, 95%CI: 1.413 - 15.779), tracheal intubations/tracheostomy ≥2 (OR=4.526, 95%CI: 1.133 - 18.083) and recurrent respiratory tract infections (OR=3.681, 95%CI: 1.177 - 11.513) were positively correlated with PTTS and PITS. The area under the ROC curve (AUC) of C/T>150% was 0.665 with the sensitivity of 0.364 and the specificity of 0.033 (95%CI: 0.555 - 0.775). AUC of intubation time>7 d was 0.717 with the sensitivity of 0.568 and the specificity of 0.133 (95%CI: 0.613 - 0.821). AUC of tracheal intubations/tracheostomy ≥2 was 0.683 with the sensitivity of 0.432 and the specificity of 0.067 (95%CI: 0.574 - 0.791). AUC of recurrent respiratory tract infections was 0.707 with the sensitivity of 0.614 and the specificity of 0.200 (95%CI: 0.603 - 0.811). However, there was no statistically significant difference C/T>150% and those clinical data in Z test (Z=0.839, P=0.402; Z=0.302, P=0.763; Z=0.751, P=0.453).ConclusionIntubation time>7 d, tracheal intubations/tracheostomy ≥2, recurrent respiratory tract infections, replacement of tracheal tube≥ 2 and C/T>150% are risk factors for PTTS and PITS.
ObjectiveTo establish the Z-score reference ranges of fetal arterial ductus (DA) inner diameter of normal fetus at 20 to 40 weeks’ gestation.MethodsA cross-sectional study was conducted in 781 normal singleton pregnancies with 20-40 weeks of gestation who underwent fetal echocardiography in the Third Affiliated Hospital of Henan University of Chinese Medicine from November 2018 to September 2019. The DA diameter, biparietal diameter (BPD), and femoral diaphysis length (FL) were measured and used to estimate gestational age (GA). With BPD, FL, and GA as independent variables and DA as dependent variables, linear regression analyses were conducted on the mean and standard deviation of each parameter to construct the best Z-score models.ResultsThe linear regression equations reflected strong positive correlations between the fetal biological growth parameter BPD, FL, GA, and fetal DA inner diameter. The heteroscedasticity of standard deviations was eliminated by the weighted regression of absolute stagger, and the best Z-score models were constructed. The linear regression equations of GA (week), BPD (mm), FL (mm), and DA inner diameter (mm) were as follows: Y=−2.661+0.217×GA, Y=−2.505+0.084×BPD, Y=−1.734+0.100×FL; the linear regression equations of GA (week), BPD (mm), FL (mm), and the standard deviation of DA inner diameter (mm) were as follows:Y=−0.273+0.025×GA, Y=−0.440+0.013×BPD, Y=−0.180+0.012×FL. According to the models, Z-score normal range reference values of fetal DA inner diameter were calculated.ConclusionsThere are good linear relationships between fetal DA inner diameter and GA, BPD and FL. The Z-score reference ranges of fetal DA diameter during mid- and late-pregnancy are constructed, which are helpful to quantitatively evaluate the normal development of fetal DA and provide a reference for clinical diagnosis of fetal DA abnormality.
Research on the deposition of inhaled particles in human pulmonary acinus region is important to the pathogenesis investigation, prevention and treatment of lung diseases. Most of the current research focus on the final deposition fraction of inhaled particles in human acinar region, but little is involved in their dynamic deposition characteristics. In this paper, five multi-alveolar models, G3−G7, were built. The evaluation parameter 1/4 deposition time was introduced to study the particle deposition speed. The deposition characteristics of particles in the diameter ranging 0.1−5 μm were numerically simulated and summarized under the influence of factors such as the generation and structure of model, particle diameter and respiratory mode, shedding some new light on the further research of transport of inhaled particles. The results showed that the generation and structure of model had a significance effect on the deposition of particles. 0.1 μm particles were dominated by Brownian diffusion, which experienced a high deposition fraction, a fast deposition speed and a logarithmic deposition curve, while 5 μm particles were dominated by gravitational sedimentation, with a high deposition fraction, a fast deposition speed and an S-shaped deposition curve. The deposition of 0.3−1 μm particles were influenced greatly by convention and varied with the change of respiratory mode. The research methods and results in this paper can provide theoretical basis and data support for the further exploration of the mechanism, prevention and treatment of lung diseases.
ObjectiveTo analyze risk factors of early outcomes of mitral valvuloplasty (MVP)for the treatment of degenerative mitral regurgitation (DMR). MethodsClinical data of 132 DMR patients who underwent MVP in Fu Wai Hospital between January 1, 2011 and November 1, 2011 were retrospectively analyzed. A total of 114 patients (86.4%)were followed up after discharge with their mean age of 51.21±12.78 years, including 76 males (66.7%). Preoperative risk factors of early outcomes of MVP were analyzed. ResultsAmong those patients, there were 25 patients with atrial fibri-llation (AF)(21.9%). Preoperative ejection fraction was 63.88%±6.93%. Preoperative echocardiography showed left ventricular end-diastolic diameter (LVEDD)was 31.61±5.51 mm/m2. There were 66 patients (57.9%)with tricuspid regurg-itation, and 34 patients (29.8%)underwent concomitant tricuspid valvuloplasty including 10 patients (8.8%)who received tricuspid annuloplasty rings. Two patients died postoperatively, 2 patients underwent re-operation of mitral valve replacement or MVP respectively. Postoperative echocardiography showed moderate or severe mitral regurgitation in 15 patients. Preoperative risk factors of early outcomes of MVP included AF (36.8% vs. 18.9%, P=0.035), large LVEDD (34.02±3.76 mm/m2 vs. 31.15±5.68 mm/m2, P=0.042)and functional mitral regurgitation (15.8% vs. 1.1%, P=0.007). Multivariate analysis showed greater postoperative LVEDD reduction significantly lowered the incidence of postoperative events (HR 0.002, 95% CI < 0.001-0.570, P=0.031). ConclusionsEnlargement of the left ventricle is an independent preoperative risk factor for early outcomes of MVP for DMR patients. Greater postoperative LVEDD reduction significantly lowers the incidence of postoperative events.
Reports about the application of transcatheter aortic valve replacement (TAVR) for patients with aortic stenosis, whose valve sizes exceed the maximum recommended annular diameter of the largest artificial valve, is rarely in China. This paper reports an aortic stenosis patient characterized by large aortic annulus diameter with severe calcification and treated by TAVR. A comprehensive and careful operation plan was made before the operation. The anterior and posterior balloon dilatation and coronary artery protection were used during the operation. The patient was followed up for 2 years and was in stable condition.
ObjectiveTo investigate the feature of the angulation between left pulmonary artery (LPA) and main pulmonary artery (MPA) and its relationship to pulmonary artery development in patients with tetralogy of Fallot (TOF).MethodsA total of 101 TOF patients in West China Hospital from 2014 to 2018 were enrolled in a TOF group, including 62 males and 39 females, aged 6.8 (0.3-45.8) years, and another 20 patients without basic cardiac diseases at the same stage were enrolled in a control group, including 10 males and 10 females, aged 6.9 (0.3-54.0) years. Diameters of LPA, right pulmonary artery (RPA) and MPA, the angulation between LPA and MPA (MPA-LPA), McGoon ratio, and Nakata index were measured and compared between the two groups. The relationship between the above data and MPA-LPA angulation was also analyzed.ResultsThe average MPA-LPA angulation was smaller in the TOF group than that in the control group (113.63° vs. 128.45°, P=0.001 8). The MPA Z score was also smaller in the TOF group than that in the control group (0.46 vs. 2.75, P=0.000 4). No relationship was found by correlation analysis between the MPA-LPA angulation and MPA Z score or LPA Z score in the control group (P=0.239 6, 0.114 7) and the TOF group (P=0.759 3, 0.242 7). The McGoon ratios (2.22±0.72, 2.43±0.94, P=0.340 0) and Nakata index (359.3±294.24, 395.52±329.31, P=0.650 0) were not significantly different between the two groups.ConclusionThe angulation of LPA-MPA and MPA Z score are smaller in the TOF group than those in the control group. There is no relationship between MPA-LPA angulation and pulmonary artery diameters. The LPA-MPA angulation should not be considered as an influence factor for LPA development and trans-annular patch surgery.
【Abstract】 Objective To design a novel small-cal iber vascular graft using a decellularized allogeneic vascularscaffold pre-loaded with bFGF. Methods The decellularized canine common carotid were obtained by a detergent-enzymatic procedure, then the scaffolds were covalently l inked with heparin and pre-loaded with bFGF, the amount of binding bFGF and releasing curve were assayed by ELISA. Canine BMSCs expanded in vitro were seed on the scaffolds to observe the effects of binding bFGF on prol iferation. Both bFGF pre-loaded and non-pre-loaded decellularized grafts were implanted in canines as carotid artery interposition for 8 weeks, the patency was examined by digital subtraction angiography and histological method. Results Histology and electron microscopic examination of the decellularized scaffolds showed that cellular components were removed completely and that the extracellular matrix structure remained intact. The amount of binding bFGF positively related to the concentration of bFGF. There was a significant difference in the amount of binding bFGF between two different scaffoldsthroughout all bFGF concentrations(P lt; 0.05), and up to 100 ng/mL, the local and sustained release of bFGF from the heparin treated scaffolds were assayed up to 20 days. Additionally, MTT test showed the bFGF-preloaded scaffolds significantly enhanced the prol iferation of seeded BMSCs in vitro compared with non-bFGF-preloaded scaffolds at 3 days after seeding and thereafter(P lt; 0.01). Furthermore, in vivo canine experiments revealed that all 8 bFGF-pre-loaded scaffolds remained patent after 8 weeks of implantation, and host cell l ined the lumen and populated the wall. Only 1 non-bFGF-pre-loaded scaffold was patent, and the other 7 grafts were occluded because of thrombsus formation. Conclusion This study provides a new strategy to develop a small diameter vascular graft with excellent biocompatibil ity and high patency rate.