In order to accurately implant the brain electrodes of carp robot for positioning and navigation, the three-dimensional model of brain structure and brain electrodes is to be proposed in the study. In this study, the tungsten electrodes were implanted into the cerebellum of a carp with the aid of brain stereotaxic instrument. The brain motor areas were found and their three-dimensional coordinate values were obtained by the aquatic electricity stimulation experiments and the underwater control experiments. The carp brain and the brain electrodes were imaged by 3.0 T magnetic resonance imaging instrument, and the three-dimensional reconstruction of carp brain and brain electrodes was carried out by the 3D-DOCTOR software and the Mimics software. The results showed that the brain motor areas and their coordinate values were accurate. The relative spatial position relationships between brain electrodes and brain tissue, brain tissue and skull surface could be observed by the three-dimensional reconstruction map of brain tissue and brain electrodes which reconstructed the three-dimensional structure of brain. The anatomical position of the three-dimensional reconstructed brain tissue in magnetic resonance image and the relationship between brain tissue and skull surface could be observed through the three-dimensional reconstruction comprehensive display map of brain tissue. The three-dimensional reconstruction model in this study can provide a navigation tool for brain electrodes implantation.
A hand-held electrocardiogram (ECG) monitor with capacitive coupling is designed in this study that can rapidly detect ECG signals through clothing. This new device improves many deficiencies of the traditional ECG monitor, such as infection due to direct skin contacting, inconvenience, and time-consuming. In specificity, the hand-held ECG monitor consists of two parts, a sensor and an embedded terminal. ECG signals are initially detected by a sensing electrode placed on the chest through clothing, then treated by single ended differential amplification, filtering and master amplification, and later processed through A/D conversion and ECG signal transmission by CC2540 module. The waveform and heart rate are finally displayed on the screen based on digital filtering and data processing for the received ECG signal on the embedded terminal. Results confirm that the newly developed hand-held ECG monitor is capable of detecting real-time ECG signals through clothing with advantages of simple operation, portability and rapid detection.
In order to reduce the mortality rate of cardiovascular disease patients effectively, improve the electrocardiogram (ECG) accuracy of signal acquisition, and reduce the influence of motion artifacts caused by the electrodes in inappropriate location in the clothing for ECG measurement, we in this article present a research on the optimum place of ECG electrodes in male clothing using three-lead monitoring methods. In the 3-lead ECG monitoring clothing for men we selected test points. Comparing the ECG and power spectrum analysis of the acquired ECG signal quality of each group of points, we determined the best location of ECG electrodes in the male monitoring clothing. The electrode motion artifacts caused by improper location had been significantly improved when electrodes were put in the best position of the clothing for men. The position of electrodes is crucial for ECG monitoring clothing. The stability of the acquired ECG signal could be improved significantly when electrodes are put at optimal locations.
Micro- and integrated biosensor provides a powerful means for cell electrophysiology research. The technology of electroplating platinum black on the electrode can uprate signal-to-noise ratio and sensitivity of the sensor. For quantifying analysis of the processing method of electroplating process, this paper proposes a grid search algorithm based on the Monte-Carlo model. The paper also puts forward the operational optimization strategy, which can rapidly implement the process of large-scale nanoparticles with different particle size of dispersion (20-200 nm) attaching to the electrode and shortening a simulation time from average 20 hours to 0.5 hour when the test number is 10 and electrode radius is 100 μm. When the nanoparticle was in a single layer or multiple layers, the treatment uniformity and attachment rate was analyzed by using the grid search algorithm with different sizes and shapes of electrode. Simulation results showed that under ideal conditions, when the electrode radius is less than 100 μm, with the electrode size increasing, it has an obvious effect for the effective attachment and the homogeneity of nanoparticle, which is advantageous to the quantitative evaluation of electrode array's repeatability. Under the condition of the same electrode area, the best attachment is on the circular electrode compared to the attachments on the square and rectangular ones.
The injury of the knee joint is usually accompanied with the generation of hydrops. The volume of hydrops can be used as a reference to evaluate the extent of knee joint injuries. Based on the principle of bioimpedance detection, in this paper, a new method is proposed to detect knee joint hydrops. Firstly, a three-dimensional model of the knee joint was established according to the physiological and anatomical structure of the knee joint. Secondly, a knee impedance detection system was constructed based on the four-electrode theory, and the relationship between the knee impedance change and the volume of hydrops was calculated by linear regression. Finally, the model of rat knee joint hydrops was established, and the knee joint impedance was measured under different hydrops content to deduce the relationship between the fluid content and the knee joint impedance. The fluid volume in the joint was calculated by measuring the knee joint impedance, and the error rate was less than 10%. The experimental results show that the method proposed in this paper can establish the relationship between the impedance of the knee and the volume of fluid and realize the detection of the fluid volume.
In order to accurately localize the image coordinates and serial numbers of intraoperative subdural matrix electrodes, a matrix electrode localization algorithm for image processing is proposed in this paper. Firstly, by using point-by-point extended electrode location algorithm, the electrode is expanded point-by-point vertically and horizontally, and the initial coordinates and serial numbers of each electrode are determined. Secondly, the single electrode coordinate region extraction algorithm is used to determine the best coordinates of each electrode, so that the image coordinates and serial numbers of all electrodes are determined point-by-point. The results show that the positioning accuracy of electrode serial number is 100%, and the electrode coordinate positioning error is less than 2 mm. The algorithms in this paper can accurately localize the image coordinates and the serial numbers of a matrix electrode arranged in an arc, which could aid drawing of cortical function mapping, and achieve precise positioning of brain functional areas, so that it can be widely used in neuroscience research and clinical application based on electrocorticogram analysis.
In order to quantitatively evaluate the performance of dry electrode for fabric surface bioelectricity, a set of active measuring devices that can simulate electrocardiosignal has been developed on the basis of passive system by our group. Five Ag/AgCl fabric dry electrodes were selected to test and evaluate the devices. The results show that the deviation ratios of peak time interval of the five electrodes are all less than 1%. The maximum voltage amplitude decay rate is 7.2%, and the noise amplitudes are lower than 0.004 mV. The variable coefficient of peak time offset is less than 8%. The variable coefficient of voltage amplitude is less than 2%. The variable coefficient of noise amplitude is less than 10%. Research shows the devices has good repeatability and stability in measuring the simulated electrocardiosignal. The active measuring devices proposed in this paper can provide a new method for performance evaluation and standard formulation of surface bioelectricity dry electrode.
ObjectiveTo evaluate the application of stereotactic electrode implantation on precise epileptogenic zone localization. MethodRetrospectively studied 140 patients with drug-resist epilepsy from March 2012 to June 2015, who undergone a procedure of intracranial stereotactic electrode for localized epileptogenic zone. ResultsIn 140 patients who underwent the ROSA navigated implantation of intracranial electrode, 109 are unilateral implantation, 31 are bilateral; 3 patients experienced an intracranial hematoma caused by the implantation. Preserved time of electrodes, on average, 8.4days (range 2~35 days); Obseved clinical seizures, on average, 10.8 times per pt (range 0~98 times); There were no cerebrospinal fluid leak, intracranial hematoma, electrodes fracture or patient death, except 2 pt's scalp infection (1.43%, scalp infection rate); 131 pts' seizure onset area was precisely localized; 71 pts underwent SEEG-guide resections and were followed up for more than 6 months. In the group of 71 resection pts, 56 pts were reached Engel I class, 2 were Engel Ⅱ, 3 was Engel Ⅲ and 10 were Engel IV class. ConclusionTo intractable epilepsy, when non-invasive assessments can't find the epileptogenic foci, intracranial electrode implantation combined with long-term VEEG is an effective method to localize the epileptogenic foci, especially the ROSA navigated stereotactic electrode implantation, which is a micro-invasive, short-time, less-complication, safe-guaranteed, and precise technique.
Transcranial direct current stimulation (tDCS) is a brain stimulation intervention technique, which has the problem of different criteria for the selection of stimulation parameters. In this study, a four-layer real head model was constructed. Based on this model, the changes of the electric field distribution in the brain with the current intensity, electrode shape, electrode area and electrode spacing were analyzed by using finite element simulation technology, and then the optimal scheme of electrical stimulation parameters was discussed. The results showed that the effective stimulation region decreased and the focusing ability increased with the increase of current intensity. The normal current density of the quadrilateral electrode was obviously larger than that of the circular electrode, which indicated that the quadrilateral electrode was more conducive to current stimulation of neurons. Moreover, the effective stimulation region of the quadrilateral electrode was more concentrated and the focusing ability was stronger. The focusing ability decreased with the increase of electrode area. Specifically, the focusing tended to increase first and then decrease with the increase of electrode spacing and the optimal electrode spacing was 64.0–67.2 mm. These results could provide some basis for the selection of electrical stimulation parameters.
A digital system for bioimpedance and electrical impedance tomography (EIT) measurement controlled by an ATmega16 microcontroller was constructed in our laboratory. There are eight digital electrodes using AD5933 to measure the impedance of the targets, and the data is transmitted to the computer wirelessly through nRF24L01. The structure of the system, circuit design, system testing, vitro measurements of animals' tissues and electrical impedance tomography are introduced specifically in this paper. The experimental results showed that the system relative error was 0.42%, and the signal noise ratio was 76.3 dB. The system not only can be used to measure the impedance by any two electrodes within the frequency of 1-100 kHz in a sweep scanning, but also can reconstruct the images of EIT. The animal experiments showed that the data was valid and plots were fitting with Cole-Cole theory. The testing verified the feasibility and effectiveness of the system. The images reconstructed of a salt-water tank are satisfactory and match with the actual distribution of the tank. The system improves the effectiveness of the front-end measuring signal and the stability of the system greatly.