  • Non-contact Heart Rate Estimation Based on Joint Approximate Diagonalization of Eigenmatrices Algorithm

    Based on the imaging photoplethysmography (iPPG) and blind source separation (BSS) theory the author put forward a method for non-contact heartbeat frequency estimation. Using the recorded video images of the human face in the ambient light with Webcam, we detected the human face through software, separated the detected facial image into three channels RGB components. And then preprocesses i.e. normalization, whitening, etc. were carried out to a certain number of RGB data. After the independent component analysis (ICA) theory and joint approximate diagonalization of eigenmatrices (JADE) algorithm were applied, we estimated the frequency of heart rate through spectrum analysis. Taking advantage of the consistency of Bland-Altman theory analysis and the commercial Pulse Oximetry Sensor test results, the root mean square error of the algorithm result was calculated as 2.06 beat/min. It indicated that the algorithm could realize the non-contact measurement of heart rate and lay the foundation for the remote and non-contact measurement of multi-parameter physiological measurements.

    Release date: Export PDF Favorites Scan
  • An improved peak extraction method for heart rate estimation

    In order to solve imperfection of heart rate extraction by method of traditional ballistocardiogram (BCG), this paper proposes an improved method for detecting heart rate by BCG. First, weak cardiac activity signals are acquired in real time by embedded sensors. Local BCG beats are obtained by signal filtering and signal conversion. Second, the heart rate is estimated directly from the BCG beat without the use of a heartbeat template. Compared with other methods, the proposed method has strong advantages in heart rate data accuracy and anti-interference, and it also realizes non-contact online detection. Finally, by analyzing the data of more than 20,000 heart rates of 13 subjects, the average beat error was 0.86% and the coverage was 96.71%. It provides a new way to estimate heart rate for hospital clinical and home care.

    Release date:2019-12-17 10:44 Export PDF Favorites Scan
  • Unconstrained detection of ballistocardiogram and heart rate based on vibration acceleration

    The requirement for unconstrained monitoring of heartbeat during sleep is increasing, but the current detection devices can not meet the requirements of convenience and accuracy. This study designed an unconstrained ballistocardiogram (BCG) detection system using acceleration sensor and developed a heart rate extraction algorithm. BCG is a directional signal which is stronger and less affected by respiratory movements along spine direction than in other directions. In order to measure the BCG signal along spine direction during sleep, a 3-axis acceleration sensor was fixed on the bed to collect the vibration signals caused by heartbeat. An approximate frequency range was firstly assumed by frequency analysis to the BCG signals and segmental filtering was conducted to the original vibration signals within the frequency range. Secondly, to identify the true BCG waveform, the accurate frequency band was obtained by comparison with the theoretical waveform. The J waves were detected by BCG energy waveform and an adaptive threshold method was proposed to extract heart rates by using the information of both amplitude and period. The accuracy and robustness of the BCG detection system proposed and the algorithm developed in this study were confirmed by comparison with electrocardiogram (ECG). The test results of 30 subjects showed a high average accuracy of 99.21% to demonstrate the feasibility of the unconstrained BCG detection method based on vibration acceleration.

    Release date:2019-04-15 05:31 Export PDF Favorites Scan
  • Extraction and recognition of attractors in three-dimensional Lorenz plot

    Lorenz plot (LP) method which gives a global view of long-time electrocardiogram signals, is an efficient simple visualization tool to analyze cardiac arrhythmias, and the morphologies and positions of the extracted attractors may reveal the underlying mechanisms of the onset and termination of arrhythmias. But automatic diagnosis is still impossible because it is lack of the method of extracting attractors by now. We presented here a methodology of attractor extraction and recognition based upon homogeneously statistical properties of the location parameters of scatter points in three dimensional LP (3DLP), which was constructed by three successive RR intervals as X, Y and Z axis in Cartesian coordinate system. Validation experiments were tested in a group of RR-interval time series and tags data with frequent unifocal premature complexes exported from a 24-hour Holter system. The results showed that this method had excellent effective not only on extraction of attractors, but also on automatic recognition of attractors by the location parameters such as the azimuth of the points peak frequency (APF) of eccentric attractors once stereographic projection of 3DLP along the space diagonal. Besides, APF was still a powerful index of differential diagnosis of atrial and ventricular extrasystole. Additional experiments proved that this method was also available on several other arrhythmias. Moreover, there were extremely relevant relationships between 3DLP and two dimensional LPs which indicate any conventional achievement of LPs could be implanted into 3DLP. It would have a broad application prospect to integrate this method into conventional long-time electrocardiogram monitoring and analysis system.

    Release date:2018-02-26 09:34 Export PDF Favorites Scan
  • Precise measurement of human heart rate based on multi-channel radar data fusion

    To achieve non-contact measurement of human heart rate and improve its accuracy, this paper proposes a method for measuring human heart rate based on multi-channel radar data fusion. The radar data were firstly extracted by human body position identification, phase extraction and unwinding, phase difference, band-pass filtering optimized by power spectrum entropy, and fast independent component analysis for each channel data. After overlaying and fusing the four-channel data, the heartbeat signal was separated using frost-optimized variational modal decomposition. Finally, a chirp Z-transform was introduced for heart rate estimation. After validation with 40 sets of data, the average root mean square error of the proposed method was 2.35 beats per minute, with an average error rate of 2.39%, a Pearson correlation coefficient of 0.97, a confidence interval of [–4.78, 4.78] beats per minute, and a consistency error of –0.04. The experimental results show that the proposed measurement method performs well in terms of accuracy, correlation, and consistency, enabling precise measurement of human heart rate.

    Release date:2024-06-21 05:13 Export PDF Favorites Scan
  • Study on the accuracy of cardiopulmonary physiological measurements by a wearable physiological monitoring system under different activity conditions

    This paper aims to study the accuracy of cardiopulmonary physiological parameters measurement under different exercise intensity in the accompanying (wearable) physiological parameter monitoring system. SensEcho, an accompanying physiological parameter monitoring system, and CORTEX METALYZER 3B, a cardiopulmonary function testing system, were used to simultaneously collect the cardiopulmonary physiological parameters of 28 healthy volunteers (17 males and 11 females) in various exercise states, such as standing, lying down and Bruce treadmill exercise. Bland-Altman analysis, correlation analysis and other methods, from the perspective of group and individual, were used to contrast and analyze the two types of equipment to measure parameters of heart rate and breathing rate. The results of group analysis showed that the heart rate and respiratory rate data box charts collected by the two devices were highly consistent. The heart rate difference was (−0.407 ± 3.380) times/min, and the respiratory rate difference was (−0.560 ± 7.047) times/min. The difference was very small. The Bland-Altman plot of the heart rate and respiratory rate in each experimental stage showed that the proportion of mean ± 2SD was 96.86% and 95.29%, respectively. The results of individual analysis showed that the correlation coefficients of the whole-process heart rate and respiratory rate data were all greater than 0.9. In conclusion, SensEcho, as an accompanying physiological parameter monitoring system, can accurately measure the human heart rate, respiration rate and other key cardiopulmonary physiological parameters under various sports conditions. It can maintain good stability under various sports conditions and meet the requirements of continuous physiological signal collection and analysis application under sports conditions.

    Release date:2020-04-18 10:01 Export PDF Favorites Scan
  • Assessment of the Effect of Pain on Autonomic Nervous System in Human Body Using Heart Rate Variability Analysis

    The purpose of this study is to discuss the feasibility of establishing capsaicin pain model and the possibility to evaluate different degrees of pain by the heart rate variability (HRV). It also aims to investigate the changes of autonomic nervous activity of volunteers during the process of pain caused by capsaicin. A total of 30 volunteers were selected, who were physically and mentally healthy, into the study. To assess the effects of capsaicin on the healthy volunteers, we recorded the Visual Analogue Scale (VAS) scores after the capsaicin stimulus. Additionally, the electrocardiogram signals and HRV analysis index before and after stimulating were also recorded, respectively. More specifically, the HRV analysis indexes included the time domain index, the frequency domain index, and the nonlinear analysis index. The results demonstrated that the activity of the autonomic nerves was enhanced in the process of capsaicin stimulus, especially for the sympathetic nerve, which exhibited a significantly differences in HRV. In conclusion, the degree of pain can be reflected by the HRV. It is feasible to establish a capsaicin pain model. And in further experiments, HRV analysis could be used as a reference index for quantitative evaluation of pain.

    Release date: Export PDF Favorites Scan
  • Analysis Methods of Short term Non linear Heart Rate Variability and Their Application in Clinical Medicine

    The linear analysis for heart rate variability (HRV), including time domain method, frequency domain method and timefrequency analysis, has reached a lot of consensus. The nonlinear analysis has also been widely applied in biomedical and clinical researches. However, for nonlinear HRV analysis, especially for shortterm nonlinear HRV analysis, controversy still exists, and a unified standard and conclusion has not been formed. This paper reviews and discusses three shortterm nonlinear HRV analysis methods (fractal dimension, entropy and complexity) and their principles, progresses and problems in clinical application in detail, in order to provide a reference for accurate application in clinical medicine.

    Release date: Export PDF Favorites Scan
  • Investigation into Feasibility of Congestive Heart Failure Diagnosis Based on Analysis of Very Short-term Heart Rate Variability

    The analysis parameters for the characterization of heart rate variability (HRV) within a very short time (<1 min) usually exhibit complicate variation patterns over time, which may easily interfere the judgment to the status of the cardiovascular system. In this study, long-term HRV sequence of 41 cases of healthy people (control group) and 25 cases of congestive heart failure (CHF) patients (experimental group) was divided into multiple segments of very short time series. The variation coefficient of the same HRV parameter under multiple segments of very short time series and the testing proportion with statistically significant differences under multiple interclass t-test were calculated. On this account, part of HRV analysis parameters under very short time were discussed to reveal the stability of difference of the cardiovascular system function under different status. Furthermore, with analyzing the receiver operating characteristic (ROC) curve and modeling the artificial neural network (ANN), the classification effects of these parameters between the control group and the experimental group were assessed. The results demonstrated that ① the indices of entropy of degree distribution based on the complex network analysis had a lowest variation coefficient and was sensitive to the pathological status (in 79.75% cases, there has statistically significant differences between the control group and experimental group), which can be served as an auxiliary index for clinical doctor to diagnose for CHF patient; ② after conducting ellipse fitting to Poincare plot, in 98.5% cases, there had statistically significant differences for the ratio of ellipse short-long axis (SDratio) between the control group and the experimental group; when modeling the ANN and solely adopting SDratio, the classification accuracy to the control group and experimental group was 71.87%, which demonstrated that SDratio might be acted as the intelligent diagnosis index for CHF patients; ③ however, more sensitive and robust indices were still needed to find out for the very-short HRV analysis and for the diagnosis of CHF patients as well.

    Release date:2017-01-17 06:17 Export PDF Favorites Scan
  • Estimation of the Power Spectrum of Heart Rate Variability Using Improved Welch Method to Analyze the Degree of Fatigue

    Heart rate variability (HRV) is an important point to judge a person’s state in modern medicine. This paper is aimed to research a person’s fatigue level connected with vagal nerve based on the HRV using the improved Welch method. The process of this method is that it firstly uses a time window function on the signal to be processed, then sets the length of time according to the requirement, and finally makes frequency domain analysis. Compared with classical periodogram method, the variance and consistency of the present method have been improved. We can set time span freely using this method (at present, the time of international standard to measure HRV is 5 minutes). This paper analyses the HRV’s characteristics of fatigue crowd based on the database provided by PhysioNet. We therefore draw the conclusion that the accuracy of Welch analyzing HRV combining with appropriate window function has been improved enormously, and when the person changes to fatigue, the vagal activity is diminished and sympathetic activity is raised.

    Release date: Export PDF Favorites Scan