Objective To compare the effectiveness of simultaneous and delayed repair of combined full-thickness rotator cuff rupture in proximal humerus fracture. Methods Between January 2015 and January 2017, 44 patients with proximal humerus fractures complicated with full-thickness rotator cuff injuries were included. Twenty-four patients underwent open reduction and internal fixation (ORIF) and rotator cuff repair simultaneously (simultaneous operation group), and 20 patients underwent delayed arthroscopic rotator cuff repair more than 90 days after ORIF (delayed operation group). There was no significant difference in gender, age, cause of injury, and side of injury between the two groups (P>0.05). The fracture healing was observed by X-ray films. The shoulder function was assessed at 3, 6, and 12 months after operation by using the University of California at Los Angeles (UCLA) score. Results All incisions healed by first intention. All patients were followed up 12-24 months (mean, 17 months). Fractures all healed at 3 months after operation in simultaneous operation group. According to UCLA score, the patients had achieved significantly better outcomes in function, active forward flexion, strength of forward flexion, and subjective satisfaction in simultaneous operation group than in delayed operation group at 3, 6, and 12 months after operation (P<0.05). However, there was no significant difference in pain between the two groups (P>0.05). Conclusion For patients with proximal humerus fracture complicated with full-thickness rotator cuff rupture, performing ORIF and simultaneous repair of rotator cuff can improve shoulder function and achieve better effectiveness when compared with delayed repair of rotator cuff.
Objective To compare the effectiveness of ultrasound- and arthrography-assisted Kirschner wire fixation in the treatment of Jakob type Ⅱ lateral condylar humerus fracture (LCHF) in children. Methods A clinical data of 101 children with Jakob type Ⅱ LCHF, who met the selection criteria and were admitted between April 2021 and April 2022, was retrospectively analyzed. Of them, 47 cases were treated with ultrasound-assisted Kirschner wire fixation (group A), and 54 cases with arthrography-assisted surgery (group B). There was no significant difference in gender, age, cause of injury, fracture side, and disease duration between groups (P>0.05). Intraoperative fluoroscopy times, operation time, and hospital stay, Flynn elbow joint function score, and postoperative complications were recorded and compared between groups. X-ray examination was performed to observe the healing of fracture, and measure the carrying angle and the shaft-condylar angle (SCA). ResultsThe success rate of closed reduction was significantly higher in group A than in group B (P<0.05), and the intraoperative fluoroscopy times was significantly less in group A than in group B (P<0.05). There was no significant difference in operation time and hospital stay between groups (P>0.05). All children in both groups were followed up 12-18 months, with an average of 13.6 months. X-ray reexamination showed that the fractures of both groups healed, and the difference in healing time was not significant (P>0.05). At last follow-up, there was no significant difference in carrying angle and SCA between unaffected side and affected side in both groups and between groups A and B in affected side (P>0.05). There was no significant difference in Flynn elbow joint function score between groups (P>0.05). There were 18 cases of lateral spurs formation in group A, 1 case of pinning infection and 26 cases of lateral spurs formation in group B, and there was no significant difference in the incidence of the above complications (P>0.05). ConclusionCompared with the arthrography, the ultrasound-assisted Kirschner wire fixation in the treatment of Jakob type Ⅱ LCHF in children can avoid the open reduction and decrease the number of intraoperative fluoroscopy, and obtain the good effectiveness.
Objective To investigate the short-term effectiveness of transverse antecubital incision in the treatment of failed closed reduction of Gartland type Ⅲ supracondylar humeral fractures (SHFs) in children. Methods Between July 2020 and April 2022, 20 children with Gartland type Ⅲ SHFs who failed in closed reduction were treated with internal and external condylar crossing Kirschner wire fixation through transverse antecubital incision. There were 9 boys and 11 girls with an average age of 3.1 years (range, 1.1-6.0 years). The causes of injuries were fall in 12 cases and fall from height in 8 cases. The time from admission to operation ranged from 7 to 18 hours, with an average of 12.4 hours. The healing of the incision and the occurrence of complications such as nerve injury and cubitus varus were observed after operation; the elbow flexion and extension range of motion after removing the gypsum, after removing the Kirschner wire, and at last follow-up were recorded and compared, as well as the elbow flexion and extension and forearm rotation range of motion at last follow-up between healthy and affected sides; the Baumann angle was measured on the X-ray film, and the fracture healing was observed. At last follow-up, the effectiveness was evaluated according to the Flynn elbow function evaluation criteria. ResultsAll incisions healed by first intention, and there was no skin necrosis, scar contracture, ulnar nerve injury, and cubitus varus. Postoperative pain occurred in the radial-dorsal thumb in 2 cases. The gypsum was removed and elbow flexion and extension exercises were started at 2-4 weeks (mean, 2.7 weeks) after operation, and the Kirschner wire was removed at 4-5 weeks (mean, 4.3 weeks). All the 20 patients were followed up 6-16 months, with an average of 12.4 months. The fracture healing time was 4-5 weeks, with an average of 4.5 weeks, and there was no complication such as delayed healing and myositis ossificans. The flexion and extension range of motion of the elbow joint gradually improved after operation, and there were significant differences between the time after removing the gypsum, after removing the Kirschner wire, and at last follow-up (P<0.017). There was no significant difference in the flexion and extension of the elbow joint and the forearm rotation range of motion between the healthy and affected sides at last follow-up (P>0.05). There was no significant difference in Baumann angle between the time of immediate after operation, after removing the Kirschner wire, and at last follow-up (P>0.05). According to Flynn elbow function evaluation standard, 16 cases were excellent and 4 cases were good, the excellent and good rate was 100%. Conclusion The treatment of Gartland type Ⅲ SHFs in children with failed closed reduction by internal and external condylar crossing Kirschner wire fixation through transverse antecubital incision has the advantages of complete soft tissue hinge behind the fracture for easy reduction and wire fixation, small incision, less complications, fast fracture healing, early functional recovery, reliable reduction and fixation, and can obtain satisfactory results.
Objective To evaluate the effectiveness of locking plates for Neer 3- and 4-part proximal humerus fractures. Methods A retrospective analysis was made on the clinical data of 77 patients with 3- or 4-part proximal humerus fractures, who underwent open reduction and internal fixation of locking plates and were followed up more than 12 months between July 2008 and May 2011. There were 39 males and 38 females with an average age of 54.2 years (range, 18-81 years). Fractures were caused by falling in 47 cases, by traffic accident in 16 cases, by falling from height in 4 cases, by sporting in 5 cases, and by other reasons in 5 cases. The time between injury and operation was 2-16 days (mean, 4.5 days). According to Neer classification, there were 54 cases of 3-part fracture and 23 cases of 4-part fracture. The Constant scores, visual analogue score (VAS), and the complications were evaluated during follow-up. Results After operation, healing of incisions by first intention was obtained in 76 cases and healing by second intention in 1 case. All patients were followed up 12-36 months (mean, 18.5 months). At last follow-up, the Constant score was 71.1 ± 11.9; the results were excellent in 18 cases, good in 24 cases, fair in 25 cases, and poor in 10 cases with an excellent and good rate of 54.5%. The VAS score was 2.8 ± 2.2. Bone nonunion occurred in 2 cases; the other patients had bone union within 2-6 months (mean, 3.2 months). The complications occurred in 25 cases (32.5%). Revision surgery was performed in 15 patients (19.5%). Conclusion The treatment of Neer 3- and 4-part proximal humerus fractures remains challenging. Anatomic reduction, stable fixation, and reduced humeral head blood supply disruption may lead to a satisfactory outcome.
Objective To evaluate the result of treating nonunion of lower segment of humerus with combination of rib flaps of cross chest and double plates. Methods From Feburary 2000 to May 2006, 21 cases of nounion of lower segment of humerus were treated. There were 13 males and 8 females with an average age of 36.5 years (range, 17-56 years). Accordingto AO classification, there were 5 cases of type A1.3, 7 cases of type B1.3, 6 cases of type B2.3, 2 cases of type B3.3, and 1 case of type C1.3. All nonunion occurred after internal fixation, which was caused by bone resorption at fracture end in 12 cases, by plates breakage in 3 cases, and by internal fixation loosening in 6 cases; including 8 cases of hypertrophic nonunion and 13 cases of atrophy nonunion without pseudoarthrosis. An average time of nonunion was 1.5 years (from 8 months to 3 years). All cases were treated with combination of rib flaps of cross chest (length, 3.0-3.5 cm) and double plates. The pedicle was divided 8 to 10 weeks after operation and all cases carried out functional exercise. Results The patients were followed up for an average time of 18.2 months (range, 1-3 years). All nounion of lower segment of humerus were healed and no radial nerve injury occurred. Primary heal ing of wound was achieved at both donor and recipient sites. Bony union was achieved in all cases after an average time of 3.5 months (range, 3-5 months) after operation. According to the the Hospital for Special Surgery (HSS) functional elbow index, the average score was 89.3 (range, 81.7-92.5) and the outcome was excellent in 14 cases, good in 4 cases, and poor in 3 cases, the excellent and good rate was 85.7%. Conclusion Combination of rib flaps of cross chest and double plates is an effective method of treating nonunion of lower segment of humerus.
Objective To evaluate the effectiveness of percutanous fixation with helical bridge combined fixation system (BCFS) for treatment of long split fractures involving the middle and upper humerus. Methods Between February 2018 and February 2020, 15 patients of long split fractures involving the middle and upper humerus were treated. There were 6 males and 9 females, with an average age of 62 years (range, 37-82 years). The fractures were caused by slipping in 7 cases, falling from height in 3 cases, and traffic accident in 5 cases. According to AO classification, the shaft fractures were rated as type A in 4 cases, type B in 9 cases, and type C in 2 cases. And all fractures extended to proximal humerus; and the proximal fractures were rated as one-part fracture in 11 cases and two-part fracture in 4 cases according to Neer classification. The interval between injury and operation was 1-7 days (mean, 3.2 days). Nine patients underwent closed reduction and 6 patients underwent open reduction after lengthening the incisions. All fractures were percutaneously internal fixated with helical BCFS after reduction. The operation time, intraoperative blood loss, incision healing, and fracture healing were recorded. Constant-Murley score was used to evaluate shoulder joint function, and Mayo score was used to evaluate elbow joint function. ResultsThe operation time ranged from 55 to 175 minutes, with an average of 76.5 minutes; the intraoperative blood loss ranged from 80 to 300 mL, with an average of 185.5 mL. All incisions healed by first intention, without infection or radial nerve injury. All patients were followed up 12-23 months, with an average of 16 months. The fractures all reached clinical healing, and the healing time was 12-20 weeks, with an average of 14.5 weeks. At 1 year after operation, the Constant-Murley score of the affected side was 88.7±7.6, and there was no significant difference when compared with that of the healthy side (90.8±8.3) (t=1.421, P=0.052). According to the elbow Mayo score, the score of the affected side was 97.6±6.5, and there was no significant difference when compared with the healthy side (97.7±7.3) (t=0.433, P=0.913). ConclusionThe helical BCFS can avoid the dissection of deltoid insertion and prevent the iatrogenic radial nerve injury. With satisfied effectiveness, it is suggested for minimally invasive surgical treatment of long split fractures involving the middle and upper humerus.
ObjectiveTo explore the biomechanical stability of the medial column reconstructed with the exo-cortical placement of humeral calcar screw by three-dimensional finite element analysis. MethodsA 70-year-old female volunteer was selected for CT scan of the proximal humerus, and a wedge osteotomy was performed 5 mm medially inferior to the humeral head to form a three-dimensional finite element model of a 5 mm defect in the medial cortex. Then, the proximal humeral locking plate (PHILOS) was placed. According to distribution of 2 calcar screws, the study were divided into 3 groups: group A, in which 2 calcar screws were inserted into the lower quadrant of the humeral head in the normal direction for supporting the humeral head; group B, in which 1 calcar screw was inserted outside the cortex below the humeral head, and the other was inserted into the humeral head in the normal direction; group C, in which 2 calcar screws were inserted outside the cortex below the humeral head. The models were loaded with axial, shear, and rotational loadings, and the biomechanical stability of the 3 groups was compared by evaluating the peak von mises stress (PVMS) of the proximal humerus and the internal fixator, proximal humeral displacement, neck-shaft angle changes, and the rotational stability of the proximal humerus. Seven cases of proximal humeral fractures with comminuted medial cortex were retrospectively analyzed between January 2017 and December 2020. Locking proximal humeral plate surgery was performed, and one (5 cases) or two (2 cases) calcar screws were inserted into the inferior cortex of the humeral head during the operation, and the effectiveness was observed. Results Under axial and shear force, the PVMS of the proximal humerus in group B and group C was greater than that in group A, the PVMS of the internal fixator in group B and group C was less than that in group A, while the PVMS of the proximal humerus and internal fixator between group B and group C were similar. The displacement of the proximal humerus and the neck-shaft angle change among the 3 groups were similar under axial and shear force, respectively. Under the rotational torque, compared with group A, the rotation angle of humerus in group B and group C increased slightly, and the rotation stability decreased slightly. All the 7 patients were followed up 6-12 months. All the fractures healed, and the healing time was 8-14 weeks, with an average of 10.9 weeks; the neck-shaft angle changes (the difference between the last follow-up and the immediate postoperative neck-shaft angle) was (1.30±0.42)°, and the Constant score of shoulder joint function was 87.4±4.2; there was no complication such as humeral head varus collapse and screw penetrating the articular surface. ConclusionFor proximal humeral fractures with comminuted medial cortex, exo-cortical placement of 1 or 2 humeral calcar screw of the locking plate outside the inferior cortex of the humeral head can also effectively reconstruct medial column stability, providing an alternative approach for clinical practice.
ObjectiveTo analyze the effectiveness of proximal humeral internal locking system (Philos) plate for proximal humerus fracture. MethodsThirty-three patients with proximal humerus fracture were treated with open reduction and internal fixation with Philos plate between January 2009 and January 2014. There were 19 males and 14 females, aged 23-89 years (mean, 56.6 years). The left side was involved in 15 cases, and the right side in 18 cases. The injury causes included falling in 20 cases and traffic accident in 13 cases. All cases received X-ray and CT scan and three-dimensional reconstruction before operation. According to the Neer classification, 8 cases were rated as two-part fractures, 15 cases as three-part fractures, and 10 cases as four-part fractures. The interval time between injury and surgery was 1-7 days (mean, 3.67 days). Postoperative functional outcome was evaluated using the Constant-Murley score. ResultsInfection and liquefaction occurred in 2 cases respectively, which was cured after corresponding treatment; primary healing of wound was obtained in the other 29 cases. Five patients had shoulder pain. The patients were followed up 11-47 months (mean, 33 months). The mean time of fracture union was 7.5 months (range, 5-9 months) on the X-ray films. Humeral head necrosis occurred in 2 patients with Neer four-part fractures, and internal fixation failure occurred in 3 patients (2 screw broken and 1 plate broken) with four-part fractures (2 cases) and three-part fractures (1 case), which was cured after conservative treatment. At last follow-up, the mean Constant-Murley score was 70.5 (range, 42-90); the results were excellent in 3 cases, good in 21 cases, moderate in 6 cases, and poor in 3 cases. ConclusionSatisfactory results can be expected for proximal humeral fracture by using of the proximal humeral internal locking system plate based on strict indication and early rehabilitation training.
Objective To analyze the effectiveness of tuberosity suture combined with autogenous bone grafting in reverse total shoulder arthroplasty for elderly patients with proximal humerus fracture. Methods A clinical data of 28 patients with fresh proximal humerus fractures, who met the selection criteria and admitted between June 2014 and April 2022, was retrospectively analyzed. There were 7 males and 21 females. Age ranged from 65 to 81 years, with an average of 73.8 years. The causes of injury were 21 cases of fall, 6 cases of traffic accident, and 1 case of falling from height. The time from injury to operation ranged from 5 to 20 days with an average of 9.2 days. There were 8 cases of Neer three-part fracture and 20 cases of four-part fracture. The reverse total shoulder arthroplasty was performed, and the greater and lesser tuberosities were sutered and reconstructed with autogenous bone grafting. After operation, the Constant score, American Society for Shoulder Surgery (ASES) score, and visual analogue scale (VAS) score were used to evaluate shoulder function and pain; and the active range of motion of the shoulder joint was recorded, including flexion, external rotation, and internal rotation. X-ray films were taken to observe the position of prosthesis. According to the evaluation criteria proposed by Boileau, the healing of greater tuberosity was evaluated, and the effectiveness was compared between the patients with healed and non-healed (displacement and absorption) greater tuberosity. ResultsAll incisions healed by first intention after operation. All patients were followed up 24-106 months, with an average of 60.9 months. At last follow-up, the VAS score of shoulder joint ranged from 0 to 6 (mean, 1.1). The Constant score ranged from 45 to 100 (mean, 80.1). The ASES score ranged from 57 to 100 (mean, 84.7). The active range of motions of shoulder joint were 60°-160° (mean, 118°) in flexion, 0°-50° (mean, 30°) in external rotation, and corresponding to reaching the S5-T8 vertebral body level in internal rotation. During follow-up, no shoulder joint re-dislocation or severe shoulder instability occurred, and no revision surgery was performed. X-ray film reexamination showed that there was no loosening of the prosthesis. According to the evaluation criteria proposed by Boileau, the greater tuberosity fused in 22 cases (78.6%), displaced in 3 cases (10.7%), and absorbed in 3 cases (10.7%). The shoulder joint function and pain related evaluation indicators in the healed group were significantly better than those in the non-healed group (P<0.05). ConclusionTuberosity suture combined with autogenous bone grafting is a relatively simple procedure that provides a reliable fixation for the anatomic recovery of greater and lesser tuberosities and is beneficial for the recovery of shoulder function in elderly patients with proximal humeral fractures.
Objective To explore the cl inical effects of different operative procedures in treatment of upper humerus fracture nonunion. Methods From May 2001 to September 2007, 43 cases of upper humerus fractures nonunion were treated, including 31 males and 12 females with an average age of 37 years (range, 20-57 years). The causes were trafficaccident injury in 14 cases, fall ing injury from height in 11 cases, tumbl ing injury in 7 cases, heavy pound injury in 6 cases, machine injury in 4 cases, and pathological injury in 1 case. The time from fracture to hospital ization was 10-52 months (23 months on average). After open reduction, patients were treated respectively by bone-graft plus locking compression plate fixation (9 cases), scapula flap rotation displacement plus locking compression plate fixation (15 cases), and scapula flap rotation displacement plus locking compression plate plus tibia bone lamella fixation (19 cases). Results All incisions healed by first intention. The X-ray films showed good fracture reduction. No symptoms of infection and nerve injury occurred. Forty-three patients were followed up 12 to 25 months with an average of 18 months. All of them achieved radiographic union within 3.0 to 7.5 months (4.9 months on average). According to comprehensive assessing standard of X-ray film and functions of shoulder and elbow, the results were excellent in 21 cases, good in 15 cases, fair in 4 cases, and poor in 3 cases; the excellent and good rate was 83.7%. Conclusion In the treatment of upper humerus fractures nonunion, locking compression plate can provide stable fixation. It can achieve satisfactory results so long as the right method of bone graft is chosen according to fracture site situation. But for patients undergoing repeated surgery or having nonunion for long times and poor fracture site situation, after open reduction, scapula flap rotation displacement plus locking compression plate plus tibia bone lamella fixation has good outcome.