west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "igament" 379 results
  • Research progress of lateral femoral notch sign in diagnosis of anterior cruciate ligament rupture

    ObjectiveTo summarize the relationship between lateral femoral notch sign (LFNS) and anterior cruciate ligament (ACL) rupture. MethodsThe relevant literature of LFNS at home and abroad in recent years was retrospectively reviewed, and its mechanism, diagnostic criteria and influencing factors in diagnosis of ACL rupture were summarized and analyzed.ResultsThe LFNS is associated with rotational stability of the knee. As an indirect sign of ACL rupture, the LFNS has high clinical diagnostic value, especially the diagnosis of ACL rupture with lateral meniscus injury.ConclusionThe diagnostic criteria and influencing factors of LFNS in diagnosis of ACL rupture are still unclear and controversial, which needs further study.

    Release date:2021-09-28 03:00 Export PDF Favorites Scan
  • DESIGN OF NONINVASIVE STEEL MINIPLATE FOR TENODESIS AND ITS CLINICAL APPLICATION

    To fix the ligaments, tendons or other transplantation materials by passing through bone channels was commonly used and a relialde method in the reconstruction of joint stability. Usually an additional incision was necessary on the side of the outlet of the bone channel, that the screws, plates or U-shaped staple could be applied. An instrument was designed that the steel miniplate could be fixed to the bone by noninvasive method. This technique was applied in 20 cases in which anterior cruciate ligament in 14, posterior cruciate ligament in 4, and collateral ligaments in 2 with carbon fibers. The result was successful in all patients. It was shown that it gave simple manipulation, reliable fixation and no need to have an additional incision, and it could lessen patients’ suffering and lead to satisfactory clinical result.

    Release date:2016-09-01 11:08 Export PDF Favorites Scan
  • Study on advantages and feasibility of cricoid breast ligament in anterior breast muscle prosthesis implantation after breast cancer surgery

    ObjectiveTo explore advantages and feasibility of a new prosthesis implantation method after breast cancer surgery by reacquaint breast anatomy. MethodsThe clinicopathologic data of patients with breast cancer were retrospectively collected. The patients underwent the breast cancer surgery and prosthesis implantation with cricoid breast ligament in the Xuzhou Cancer Hospital from January 1, 2021 to May 30, 2023. ResultsA total of 10 patients were collected, with age ranging from 31 to 59 years old. Three patients received postoperative analgesia, 2 patients occurred infection, 1 patient occurred fat liquefaction. All patients did not experience capsular contracture, flap necrosis, or removal of the prosthesis. Two patients had sentinel lymph node metastasis. All patients followed-up 3 to 24 months after surgery. The BREAST-Q questionnaire was used to assess the quality of life and satisfaction after surgery, 3 patients were very satisfied, 5 were satisfied, and 2 were basically satisfied. ConclusionFrom the results of limited cases analysis in this study, it is safe and feasible to implant the prosthesis with cricoid breast ligament in selected patients after breast cancer surgery.

    Release date:2023-12-26 06:00 Export PDF Favorites Scan
  • BIOMECHANICAL STUDY ON PROXIMALLY BASED CONJOINED TENDON TRANSFER FOR CORACOACROMIAL LIGAMENT RECONSTRUCTION AS ANTEROSUPERIOR RESTRAINT OF SHOULDER JOINT

    Objective To simulate anterosuperior instabil ity of the shoulder by a combination of massive irreparable rotator cuff tears and coracoacromial arch disruption in cadaveric specimens, use proximally based conjoined tendon transfer forcoracoacromial l igament (CAL) reconstruction to restrain against superior humeral subluxation, and investigate its feasibility and biomechanics property. Methods Nine donated male-adult and fresh-frozen cadaveric glenohumeral joints were applied to mimic a massive irreparable rotator cuff tear in each shoulder. The integrity of the rotator cuff tendons and morphology of the CAL were visually inspected in the course of specimen preparation. Cal ipers were used to measure the length of the CAL’s length of the medial and the lateral bands, the width of coracoid process and the acromion attachment, and the thickness in the middle, as well as the length, width and thickness of the conjoined tendon and the lateral half of the removed conjoined tendon. The glenohumeral joints were positioned in a combination of 30° extension, 0° abduction and 30° external rotation. The value of anterosuperior humeral head translation was measured after the appl ication of a 50 N axial compressive load to the humeral shaft under 4 sequential scenarios: intact CAL, subperiosteal CAL release, CAL anatomic reattachment, entire CAL excision after lateral half of the proximally based conjoined tendon transfer for CAL reconstruction. Results All specimens had an intact rotator cuff on gross inspection. CAL morphology revealed 1 Y-shaped, 4 quadrangular, and 4 broad l igaments. The length of the medial and lateral bands of the CAL was (28.91 ± 5.56) mm and (31.90 ± 4.21) mm, respectively; the width of coracoid process and acromion attachment of the CAL was (26.80 ± 10.24) mm and (15.86 ± 2.28) mm, respectively; and the thickness of middle part of the CAL was (1.61 ± 0.36) mm. The length, width, and thickness of the proximal part of the proximally based conjoined tendon was (84.91 ± 9.42), (19.74 ± 1.77), and (2.09 ± 0.45) mm, respectively. The length and width of the removed lateral half of the proximally conjoined tendon was (42.67 ± 3.10) mm and (9.89 ± 0.93) mm, respectively. The anterosuperior humeral head translation was intact CAL (8.13 ± 1.99) mm, subperiosteal CAL release (9.68 ± 1.97) mm, CAL anatomic reattachment (8.57 ± 1.97) mm, and the lateral half of the proximally conjoined tendon transfer for CAL reconstruction (8.59 ± 2.06) mm. A significant increase in anterosuperior migration was found after subperiosteal CAL release was compared with intact CAL (P lt; 0.05). The translation after CAL anatomic reattachment and lateral half of the proximally conjoined tendon transfer for CAL reconstruction increased over intact CAL, though no significance was found (P gt; 0.05); when they were compared with subperiosteal CAL release, the migration decreased significantly (P lt; 0.05). The translation of lateral half of the proximally conjoined tendon transfer for CAL reconstruction increased over CAL anatomic reattachment, but no significance was evident (P gt; 0.05). Conclusion The CAL should be preserved or reconstructed as far as possible during subacromial decompression, rotator cuff tears repair, and hemiarthroplasty for patients with massive rotator cuff deficiency. If preservation or the insertion reattachment after subperiosteal release from acromion of the CAL of the CAL is impossible, or CAL is entirely resected becauseof previous operation, the use of the lateral half of the proximally based conjoined tendon transfer for CAL reconstruction isfeasible.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
  • TREATMENT OF SEVERE MEDIAL COLLATERAL LIGAMENT RUPTURE IN MULTI-LIGAMENT INJURY

    ObjectiveTo compare the clinical efficacy between medial collateral ligament (MCL) repair and MCL reconstruction in multi-ligament injury. MethodsThirty-one patients with MCL rupture and multi-ligament injury of knee joint were treated between August 2008 and August 2012, and the clinical data were retrospectively analyzed. Of 31 patients, 11 cases underwent MCL repair (repair group), and 20 cases underwent MCL reconstruction (reconstruction group). There was no significant difference in gender, age, body mass, injury side, injury cause, and preoperative knee Lyshlom score, International Knee Documentation Committee (IKDC) subjective score, range of motion, and medial joint opening between 2 groups (P > 0.05). The postoperative knee subjective function and stability were compared between 2 groups. ResultsAll incisions healed by first intention, and no postoperative complication occurred. All patients were followed up 2-4 years (mean, 3.2 years). At 2 years after operation, the IKDC subjective score, Lyshlom score, and range of motion were significantly increased in 2 groups when compared with preoperative ones (P < 0.05). The range of motion of reconstruction group was significantly better than that of repair group (P < 0.05). No significant difference was found in IKDC subjective score and Lyshlom score between 2 groups (P > 0.05). The medial joint opening was significantly improved in 2 groups at 2 years after operation when compared with preoperative one (P < 0.05), but no significant difference was found between 2 groups (P > 0.05). ConclusionBoth the MCL reconstruction and MCL repair can restore medial stability in multi-ligament injury, but MCL reconstruction is better than MCL repair in range of motion.

    Release date: Export PDF Favorites Scan
  • MEASUREMENT OF STRENGTH OF THIGH MUSCLES THROUGH ARTHROSCOPE AFTER RECONSTRUCTION OF ANTERIOR CRUCIATE LIGAMENT

    OBJECTIVE: To observe the strength of thigh muscles after reconstruction of anterior cruciate ligament by autogenous bone-patellar tendon-bone graft. METHODS: Twenty-three patients, 9 males and 14 females, were followed up one year after reconstruction of the anterior cruciate ligament with autogenous bone-patellar tendon-bone graft. Through arthroscope, no intra-articular derangement was found. The strengths of isometric and isotonic contractions of the quadri ceps and the hamstrings muscles of the affected and contralateral thighs were recorded. RESULTS: The donor side for autogenous bone-patellar tendon-bone graft showed significant decrease (P lt; 0.01), but no effect on that of the hamstrings muscle(P gt; 0.05). CONCLUSION: To reconstruct the anterior cruciate ligament, harvest of the bone-patellar tendon-bone graft as a reparative material may markedly lower the strength of the quadriceps femoris muscle.

    Release date:2016-09-01 11:05 Export PDF Favorites Scan
  • Application of unilateral biportal endoscopy technique in single-segment thoracic ossification of ligamentum flavum

    Objective To investigate the safety and effectiveness of unilateral biportal endoscopy (UBE) technique in the treatment of single-segment thoracic ossification of ligamentum flavum (TOLF). Methods Between August 2020 and December 2021, 11 patients with single-segment TOLF were treated with UBE technique. There were 6 males and 5 females, with an average of 58.2 years (range, 49-72 years). The responsible segment was T6, 7 in 1 case, T7, 8 in 1 case, T8, 9 in 2 cases, T9, 10 in 2 cases, T10, 11 in 2 cases, and T11, 12 in 3 cases. Imaging examination showed that the ossification were located on the left side in 4 cases, on the right side in 3 cases, and on bilateral sides in 4 cases. The main clinical symptoms were chest and back pain or lower limb pain, all accompanied by lower limb numbness and fatigue. The disease duration ranged from 2 to 28 months (median, 17 months). The operation time, postoperative hospital stay, and complications were recorded. Visual analogue scale (VAS) score was used to evaluate the chest and back pain and low limb pain, and Oswestry disability index (ODI) and Japanese Orthopedic Association (JOA) score were used to evaluate functional recovery before operation and at 3 days, 1 month, 3 months after operation, and last follow-up. The anteroposterior diameter of the coronal spinal canal was measured by CT before and after operation to evaluate the effect of surgical decompression. Results All operations were successfully completed. The operation time was 50-105 minutes, with an average of 80.0 minutes. No postoperative complication such as dural sac tear, cerebrospinal fluid leakage, spinal nerve injury, or infection occurred. The postoperative hospital stay was 2-5 days, with an average of 3.1 days. All incisions healed by first intention. All patients were followed up 6-22 months, with an average of 14.8 months. CT measurement at 3 days after operation showed that the anteroposterior diameter of the spinal canal was (8.63±1.61) mm, which was significantly larger than that before operation [(3.67±1.37) mm] (t=−12.181, P<0.001). The VAS score of chest and back pain and lower limb pain and ODI at each time point after operation were significantly lower than those before operation (P<0.05). The above indexes were further improved after operation, except that there was no significant difference between at 3 months after operation and at last follow-up (P>0.05), the differences between other time points were significant (P<0.05). There was no recurrence during the follow-up period. Conclusion UBE technique is a safe and effective method to treat single-segment TOLF, but its long-term effectiveness needs to be further studied.

    Release date:2023-02-13 09:57 Export PDF Favorites Scan
  • Effect of Kartogenin combined with adipose-derived stem cells on tendon-bone healing after anterior cruciate ligament reconstruction

    Objective To investigate the effect of Kartogenin (KGN) combined with adipose-derived stem cells (ADSCs) on tendon-bone healing after anterior cruciate ligament (ACL) reconstruction in rabbits. Methods After the primary ADSCs were cultured by passaging, the 3rd generation cells were cultured with 10 μmol/L KGN solution for 72 hours. The supernatant of KGN-ADSCs was harvested and mixed with fibrin glue at a ratio of 1∶1; the 3rd generation ADSCs were mixed with fibrin glue as a control. Eighty adult New Zealand white rabbits were taken and randomly divided into 4 groups: saline group (group A), ADSCs group (group B), KGN-ADSCs group (group C), and sham-operated group (group D). After the ACL reconstruction model was prepared in groups A-C, the saline, the mixture of ADSCs and fibrin glue, and the mixture of supernatant of KGN-ADSCs and fibrin glue were injected into the tendon-bone interface and tendon gap, respectively. ACL was only exposed without other treatment in group D. The general conditions of the animals were observed after operation. At 6 and 12 weeks, the tendon-bone interface tissues and ACL specimens were taken and the tendon-bone healing was observed by HE staining, c-Jun N-terminal kinase (JNK) immunohistochemical staining, and TUNEL apoptosis assay. The fibroblasts were counted, and the positive expression rate of JNK protein and apoptosis index (AI) were measured. At the same time point, the tensile strength test was performed to measure the maximum load and the maximum tensile distance to observe the biomechanical properties. Results Twenty-eight rabbits were excluded from the study due to incision infection or death, and finally 12, 12, 12, and 16 rabbits in groups A-D were included in the study, respectively. After operation, the tendon-bone interface of groups A and B healed poorly, while group C healed well. At 6 and 12 weeks, the number of fibroblasts and positive expression rate of JNK protein in group C were significantly higher than those of groups A, B, and D (P<0.05). Compared with 6 weeks, the number of fibroblasts gradually decreased and the positive expression rate of JNK protein and AI decreased in group C at 12 weeks after operation, with significant differences (P<0.05). Biomechanical tests showed that the maximum loads at 6 and 12 weeks after operation in group C were higher than in groups A and B, but lower than those in group D, while the maximum tensile distance results were opposite, but the differences between groups were significant (P<0.05). Conclusion After ACL reconstruction, local injection of a mixture of KGN-ADSCs and fibrin glue can promote the tendon-bone healing and enhance the mechanical strength and tensile resistance of the tendon-bone interface.

    Release date:2023-08-09 01:37 Export PDF Favorites Scan
  • Musculoskeletal multibody dynamics investigation for the different medial-lateral installation position of the femoral component in unicompartmental knee arthroplasty

    The surgical installation accuracy of the components in unicompartmental knee arthroplasty (UKA) is an important factor affecting the joint function and the implant life. Taking the ratio of the medial-lateral position of the femoral component relative to the tibial insert (a/A) as a parameter, and considering nine installation conditions of the femoral component, this study established the musculoskeletal multibody dynamics models of UKA to simulate the patients’ walking gait, and investigated the influences of the medial-lateral installation positions of the femoral component in UKA on the contact force, joint motion and ligament force of the knee joint. The results showed that, with the increase of a/A ratio, the medial contact force of the UKA implant was decreased and the lateral contact force of the cartilage was increased; the varus rotation, external rotation and posterior translation of the knee joint were increased; and the anterior cruciate ligament force, posterior cruciate ligament force and medial collateral ligament force were decreased. The medial-lateral installation positions of the femoral component in UKA had little effect on knee flexion-extension movement and lateral collateral ligament force. When the a/A ratio was less than or equalled to 0.375, the femoral component collided with the tibia. In order to prevent the overload on the medial implant and lateral cartilage, the excessive ligament force, and the collision between the femoral component and the tibia, it is suggested that the a/A ratio should be controlled within the range of 0.427−0.688 when the femoral component is installed in UKA. This study provides a reference for the accurate installation of the femoral component in UKA.

    Release date:2023-08-23 02:45 Export PDF Favorites Scan
  • Artificial ligaments applied in anterior cruciate ligament repair and reconstruction: Current products and experience

    The application of artificial ligament products in anterior cruciate ligament (ACL) surgeries has gone through a long twisty way. In the 1970s, early artificial ligament products were initially used for ACL surgeries, which showed poor clinical efficacy and eventually ended up in failure. Over the last 20 years, there has been a growing number of ACL reconstruction with new artificial ligament products, including the Leeds-KeioTM, the LARSTM (Ligament Advanced Reinfocement System), and the Trevira HochfestTM. Among these new products, the LARSTM has been more commonly applied for ACL surgeries. Although these new artificial ligament products have good mechanical properties and show significant improvement of cumulative failure and complication rate, they still have limitations.

    Release date:2020-02-18 09:10 Export PDF Favorites Scan
38 pages Previous 1 2 3 ... 38 Next

Format

Content