ObjectiveTo explore the feasibility of using indocyanine green (ICG) angiography to detect brachial artery perforators, and the clinical application of brachial artery perforator propeller (BAPP) flaps to repair soft tissue defects of the trunk and upper limbs.MethodsBetween August 2016 and February 2019, ICG angiography was used to detect the perforating vessels of the brachial artery muscle septum, and the BAPP flaps were cut out with the detected perforating vessels as the pedicle to repair 19 cases of trunk and upper limb soft tissue defects. There were 12 males and 7 females, with an average age of 28.6 years (range, 5-66 years). Etiologies included the post-burn scar in 10 cases, soft-tissue sarcoma in 5 cases, congenital melanocytic nevi in 2 cases, chronic chest wall ulcer in 1 case, and malignant melanoma in 1 case. Defects located in axilla in 8 cases, chest wall in 4 cases, elbow in 5 cases, and shoulder in 2 cases. The area of the defect ranged from 15 cm×3 cm to 20 cm×8 cm. Pre-transfer tissue expansion was used in 11 patients. Thirteen flaps were pedicled with 1 perforator vessel, and 6 flaps were pedicled with 2 perforator vessels. The length of the vascular pedicle was 2.5-4.5 cm, with an average of 3.08 cm. The area of the skin flap ranged from 11 cm×5 cm to 22 cm×10 cm. The flap rotation angle was 110° in 1 case, 120° in 1 case, and 180° in 17 cases. Except for one donor site repaired by skin graft, the other donor sites were directly sutured.ResultsA total of 24 perforating vessels of the brachial artery muscle septum were detected by ICG angiography, 26 were identified during the operation, with an accuracy rate of 92.31%. Eighteen flaps survived without arteriovenous crisis. Venous congestion was observed in the distal 3-cm of one flap and the flap survived after conservative management. Intraoperative analysis showed that the blood perfusion of the distal 4-cm of one flap was poor, the relative value was less than 32%, the flap survived after removing the poor perfusion area. All the patients were followed up 3 to 23 months (mean, 8.6 months). The color and texture of the flap were similar to those of the recipient area. Flap debulking was not needed in all patients owing to the thinness of the flap. The contracture symptoms of patients with scar contracture on the medial of the elbow joint and axilla were significantly improved; a patient with malignant melanoma underwent tumor resection at 1 year and 5 months after operation due to tumor recurrence, and additional surgery was done to remove the recurrent tumor. No tumor recurrence was found in other patients.ConclusionThe ICG angiography technique can be used to explore the perforating vessels of the brachial artery muscle septum. The BAPP flap pedicled with the perforating vessels can be used for the repair of skin and soft tissue defects in the chest wall, axilla, shoulder, and elbow joint.
ObjectiveTo understand the methods of judging the blood supply of parathyroid during thyroidectomy at home and abroad in recent years. MethodThe literature on parathyroid blood supply was collected, the research progress was reviewed, and the advantages and disadvantages of related methods were analyzed. ResultsIn recent years, near-infrared fluorescence, laser speckle contrast imaging and other technologies had been applied. They showed better advantages as compared with naked eye observation. The research on parathyroid blood supply at home and abroad was still in its infancy, and more clinical samples and related equipment optimization were still needed. ConclusionFluorescence imaging technology has a certain auxiliary role in the judgment of intraoperative parathyroid blood supply and can reduce the incidence of hypoparathyroidism to a certain extent.
Objective To explore the accuracy and efficiency of indocyanine green fluorescence (ICGF) imaging in evaluating blood perfusion of parathyroid gland (PG) during total thyroidectomy. Methods Seventy patients who underwent total thyroidectomy and bilateral central lymph node dissection for papillary thyroid carcinoma (PTC) from March 2021 to December 2021 were enrolled and randomly divided into experimental group (ICGF imaging, n=35) and control group (normal treatment, n=35). Blood perfusion of PGs was evaluated by ICGF imaging and naked eye in each group respectively. The perfusion of PGs, incidence of hypoparathyroidism, and number of autotransplanted PGs were analyzed between the two groups. Results There was no difference between two groups in the incidence of transient hypoparathyroidism (P=0.339), and no one occurred permanent hypoparathyroidism. More PGs were autotransplanted in the experimental group compared to the control group (P<0.001). At least one PG with good perfusion in the experimental group predicted an extremely high rate of normal parathyroid hormone levels of the patients postoperatively than the control group (P=0.003). Conclusion ICGF imaging can evaluate the blood perfusion of PGs accurately and guide their autotransplantation.
ObjectiveTo evaluate the value of real-time indocyanine green fluorescence imaging navigation (ICG-FIN) in laparoscopic rectal cancer surgery. MethodsThe patients who adopted ICG-FIN during laparoscopic rectal cancer surgery in the Department of Anorectal Surgery of Xuzhou Central Hospital from April 2022 to June 2023 according to the inclusion and exclusion criteria (ICG-FIN group) were collected, meanwhile matching (1∶1) of patients who did not adopt ICG-FIN during laparoscopic surgery from January 2021 to May 2022 (control group). The general data, surgical conditions, intraoperative and postoperative outcomes between the two groups were compared. ResultsThere were 62 patients in the ICG-FIN group and 62 patients in the control group. There were no statistical differences in the gender, age, body mass index, comorbidities, and so on between the two groups (P>0.05). The tumor localization, lymph node tracing, fluorescence imaging of the intended resection of intestinal tract and anastomotic site were observed in the ICG-FIN group. Seven patients (11.3%) had changed in the intended resection of intestinal anastomotic line during surgery, while there were no changes of the surgical plan in the control group. There were no statistical differences (P>0.05) in terms of surgical method, operative time, intraoperative bleeding, proportion of ileostomy, time of the first postoperative exhaust, postoperative hospital stay, and incidence of short-term complications between the two groups. Compared with the control group, the incidence of anastomotic leakage was lower (P=0.012), and the number of lymph nodes cleaned was more (P=0.016) in the ICG-FIN group. However, there was no statistical difference in the number of positive lymph nodes detected between the two groups (P=0.343). ConclusionsAccording to the results of this study, ICG-FIN is a reliable and effective method during laparoscopic rectal cancer surgery, which can accurately localize tumor, trace and guide lymph node dissection. Real-time evaluation of intestinal blood flow perfusion is of great practical value in reducing anastomotic leakage.
ObjectiveTo summarize the application status and progress of indocyanine green fluorescence imaging in laparoscopic anatomic liver resection , and to analyze its advantages, limitations, and prospects.MethodThe literatures about indocyanine green fluorescence imaging in laparoscopic anatomic liver resection were reviewed.ResultsIndocyanine green fluorescence imaging had been preliminarily used in the operation of liver tumors and had shown its unique value in the anatomical liver resection, providing a new way to reduce the recurrence of liver cancer, improve the therapeutic effect, and prolong the survival time of patients.ConclusionsThe clinical application of indocyanine green fluorescence imaging in anatomic liver resection is still at the stage of development and popularization. Although it has unique advantages and development potential, it needs to be further improved in the aspects of tissue penetration, specificity, and staining success rate.
Objective To observe the location of the watershed zones of the choroidal blood supply relative to the optic disc in glaucoma by indocyan ine green angiography, and to investigate the mechanisms in the development of glaucomatous neuropathy. Method Simultaneous ICGA and FFA were performed on 31 eyes of 31 patients with glaucoma (17 of POAG, 14 of NTG) and 37 eyes of 37 control subjects. The watershed zones were classified into three types according to their location relative to the optic disc: by type I, no water shedzone around the optic disc; type II, the optic disc surrounded partially by watershed zone; type III, the optic disc surrounded completely by watershed zone. Each of the watershed zone types was scored (i.e., type I=1, type II=2, type III=3). Results In 87.1% of the glaucomatous eyes , the watershed zones included or partially included the optic disc. However, the figure in the control group was 56.8%. The glaucoma group had a higher score of watershed zone type than the control group. Conclusions The mechanisms in the development of glaucomatous neuropathy are correlative to the choroidal blood supply around the optic disc. (Chin J Ocul Fundus Dis,2004,20:218-220)
ObjectiveTo investigate the safety and feasibility of fluorescent guided laparoscopic central hepatic tumor resection via anterior transhepatic approach. MethodWe retrospectively analyzed the clinical data of three patients who underwent fluorescent guided laparoscopic central hepatic tumor resection via anterior transhepatic approach in Department of Hepatobiliary and Pancreas Minimally Invasive Surgery of Hunan Provincial People’s Hospital from April 2017 to April 2020.ResultsAll the three patients completed the operation pure laparoscopically. Pathology results showed one case of hepatocellular carcinoma and two cases of focal nodular hyperplasia, the tumor size range from 4–7 cm. The operation time was 240–320 min, and the blood loss was 150–500 mL. There was no intraoperative blood transfusion. The postoperative hospital stay was 10–30 days. Postoperative bile leakage occurred in one patient, which was cured by laparoscopic hepatectomy. Three patients were followed up for 8, 36, and 25 months, respectively, and all the patients survived and there was no tumor recurrence up to november 2020.ConclusionsLaparoscopic resection of central hepatic tumor is difficult and risky. Anterior transhepatic approach can maximize the preservation of liver parenchyma. In hepatobiliary and pancreatic centers with high volume of laparoscopic hepatectomy, this method is safe and feasible after strict patient selection, accurate preoperative evaluation, and fine intraoperative skills. Indocyanine green fluorescence navigation technology is helpful to accurately locate tumor during operation.
Objective To summarize the preoperative CT three-dimensional reconstruction, and administration and visualization of indocyanine green (ICG) during ICG-assisted laparoscopic duodenum-preserving pancreatic head resection (LDPPHR). Methods A 56-year-old female patient admitted to the Department of Biliary Surgery in West China Hospital in April 2022 was retrospectively analyzed. The patient was considered the possibility of benign tumor of pancreatic head, and underwent LDPPHR. Three-dimensional CT reconstruction was performed before operation, and ICG (5 mg) was injected intravenously preoperative and intraoperative to complete LDPPHR. Results Preoperative three-dimensional CT reconstruction can assist in judging the course and relationship of anterior and posterior pancreaticoduodenal arterial arch and surrounding main blood vessels. After intravenous injection of 5 mg ICG 24 hours before operation, the common bile duct at the upper edge of pancreas was clearly visualized, and the cystic mass was judged not to communicate with bile duct and pancreatic duct. But it was difficult to identify the pancreatic segment of the common bile duct in fluorescence mode, ICG 5 mg was injected intravenously during the resection stage, and then the common bile duct was obviously visualized. After the resection stage, injected ICG (5 mg) intravenously again. Within 1 min, the fluorescence of the duodenum was enhanced, which suggested that the blood perfusion of duodenum was well. The operative time was 280 min, the blood loss was about 200 mL. On the 10th day after operation, the patient developed transient gastrointestinal bleeding with bile leakage, which improved after symptomatic treatment and was discharged on the 19th day. Postoperative pathological examination diagnosed pancreatic serous cystadenoma. Conclusions Three-dimensional reconstruction and ICG assisted LPDDHR can successfully visualize and identify the blood vessels and bile ducts, and check the duodenal blood perfusion. Which can making the operation more accurate and visual is a powerful guarantee for LDPPHR to be carried out safely and effectively.
ObjectiveTo investigate the clinical value of three-dimensional reconstruction of liver and resection of hepatocellular carcinoma with indocyanine green (ICG) fluorescence staining. MethodsClinical data of a patient with hepatocellular carcinoma admitted to the Department of Liver Surgery of West China Hospital of Sichuan University in May 2021 were retrospectively collected. In this patient, intrahepatic vascular reconstruction was performed by SYNAPSE 3D software of Japan before operation, and the portal vein and hepatic vein corresponding to the tumor were analyzed to simulate the resection range. Intraoperative ICG fluorescence staining was used to perform laparoscopic resection of segment Ⅳ of the liver.ResultsIn this patient, the fluorescence boundary on the liver surface was clear after staining, and the intrahepatic segment fluorescence interface could still be maintained in the hepatic parenchyma dissociation, and the resection of the liver segment was consistent with the preoperative three-dimensional reconstruction plan. The operation took 230 min in total, and the bleeding was about 200 mL. On the first day after the operation, blood biochemical test showed that the plasma albumin was slightly low, and no obvious abnormalities were observed in transaminase, bilirubin, etc. After the infusion of human albumin, the indexes returned to normal, and the patient recovered and was discharged on the fourth day after the operation. No complications occurred after the operation, and no tumor recurrence and metastasis were observed during follow-up period. Conclusion3D reconstruction and ICG fluorescence guidance are safe and feasible for the treatment of hepatocellular carcinoma after laparoscopic anatomic segment Ⅳ resection, and the positive staining method of ICG fluorescence segment is recommended.
ObjectiveTo explore the feasibility and safety of using indocyanine green combined with autologous blood and methylene blue for localization of small lung nodules during thoracoscopic wedge resection. MethodsPatients who underwent CT-guided percutaneous lung puncture injection of localization agents to locate lung nodules at the First Affiliated Hospital of Fujian Medical University from November 2023 to January 2024 were selected. Under thoracoscopy, lung nodules were located by white light mode, fluorescence mode, or near-infrared mode and wedge resection was performed. The feasibility of using indocyanine green combined with autologous blood and methylene blue for localization of small lung nodules was preliminarily verified by evaluating whether the localization agent concentrated around the nodules, and the safety of this method was verified by analyzing the incidence of adverse reactions during patient puncture and surgery. ResultsA total of 30 patients with lung nodules were included, including 10 males and 20 females, with an average age of (55.5±11.2) years. In 26 patients, the amount of localization agent used was moderate, the localization agent concentrated around the nodules, and successful precise localization of small lung nodules was achieved. In 4 patients, due to excessive use of localization agent, the marker was diffuse with pleural staining. The overall localization success rate was 86.7%, and when the injection volume of localization agent was 0.2-0.5 mL, the localization success rate was 100.0%. All patients successfully completed thoracoscopic wedge resection and found nodule lesions, with negative margins and a distance from the margin to the lesion that met the requirements. There were no complications. ConclusionThoracoscopic surgery using indocyanine green combined with autologous blood and methylene blue for localization of small lung nodules is safe and feasible.