ObjectiveTo study the effects of different penetration enhancers on the transdermal penetration of Miao medicine named Diploclisia affinis. MethodsImproved Franz diffusion cell was adopted as the apparatus for in vitro mouse' skin permeation. The kinetic parameters of percutaneous absorption, such as penetration rate, enhancing rate (ER), and lag time (Tlag) were determined by high performance liquid chromatography. Azone, oleic acid (OA) and borneol were investigated for percutaneous absorption effects. ResultsThe penetration rates of the medicine with 3% azone, OA and borneol added were respectively (214.1872±13.5690), (227.5544±9.8490), and (168.1187±21.5640) μg/(cm2·h), and the ER was 1.61, 1.71, and 1.26 compared with the penetration rate of that with nothing added. The Tlag was 2.1081, 1.8256, and 2.9655 hours. ConclusionAll the penetration enhancers can increase significantly the absorption of Miao medicine named Diploclisia affinis, especially 3% OA is the best, but 3% borneol may make the Tlag longer.
PURPOSE:To investigale the influence of orally administered aldose reduetace inhibitor(ARI) and myo-inositol (MI)for contents of gluecose,sorbitol and myo-inositol in experimental diabetic retinal tissue in rat. METHODS :The STZ-induced diabetic rats were administered ARI or MI by oral. The glucose sorbitol and myo-inositol in retinal tissues were analysed by high performance liquid chromatography after experimental period of 6 montbs. RESULTS:It was found that the contents of glucose and sorhitol were increased and myo inosltol was decreased in diabetic group. In diabetes with ARI group.the content of sorbitol was increased although the glucose was in high level. In diabetes wilb MI group,the sorbitol accumulaled and coment of myo-inositol was close to the normal control group. CONCLUSIONS:The ARI can effectively obstruct sorbitol accumulation in retina. MI increase myo-inositol level but fail to reduce sorbitol contenl of retina. (Chin J Ocul Fundus Dis,1997,13: 75-77 )
ObjectiveIn order to improve the levels of clinical diagnosis and treatment of differentiated thyroid cancer, the research status and progress of blood markers of differentiated thyroid cancer in recent years were reviewed.MethodThe literatures about blood markers and liquid biopsy of differentiated thyroid cancer at home and abroad in recent years were searched and summarized.ResultsThyroglobulin and thyroglobulin antibody were the most commonly used for markers of differentiated thyroid cancer. The application value of blood markers such as microRNA and long non-coding RNA in the diagnosis, treatment and follow-up of differentiated thyroid cancer had also been found.ConclusionBecause of the advantages of high specificity, high sensitivity, and no-invasion, blood markers are useful indicators to help improve the diagnosis of thyroid cancer patients and monitor the disease progression and recurrence in the future.
OBJECTIVE: To purify and study Schwann cells cytoplasmic neurotrophic protein. METHODS: The dissociated SC taken from 300 newborn rats sciatic nerves were cultured, collected, ultrasonicated and ultraspeed centrifuged. The supernates were ultrafiltrated and concentrated by using ultrafiltration units with PM10, PM30, PM50 ultrafiltration membranes. The ultrafiltrated-concentrated solution with the protein molecular weight 10-30 ku, 30-50 ku and gt; 50 ku were collected respectively. The dissociated spinal cord motoneurons of 14 days embryonic rats were cultured with serum-free conditional medium and the additional SC cytoplasmic proteins were added into the medium. The results showed that the 10-30 ku and gt; 50 ku SC cytoplasmic proteins were able to maintain the survival of motoneurons for 24 hours. Then the 26 ku and 58 ku proteins were further extracted and purified from SC cytoplasm by high pressure liquid chromatography, and their neurobiological activities were studied. RESULTS: The 26 ku and 58 ku Schwann cell’s cytoplasmic proteins were able to maintain the survival of motoneurons cultured in the serum-free medium for 48 hours. The highest biological activity concentration is 20 ng per well. CONCLUSION: Schwann cells cytoplasm contains motoneuron neurotrophic proteins with molecular weight 26 ku and 58 ku.
Objective To summarize the available clinical research evidence on gliquidone for treating diabetes mellitus. Methods The clinical research on gliquidone for diabetes mellitus was systematically searched and appraised. Result Six randomized controlled trials and eleven controlled clinical trials were identified. The methodological quality of most papers about gliquidone for diabetes mellitus was poor. Currently, clinically patient-related endpoints as outcome measures and health economic analyses are lacking in this field. Conclusions Based on the available evidence, gliquidone appears specifically applicable to elderly diabetic patients with kidney diseases. More methodologically sound and patient-related endpoints and economic analyses based on clinical research are required.
Compound Huangbai liquid coating agent is a preparation that combines multiple traditional Chinese medicinal herbs and has shown significant efficacy in burn treatment. In recent years, the application of this coating agent in burn treatment has received widespread attention, and it plays a role in promoting wound healing, preventing infection, and reducing patient pain. This article reviews the research progress of compound Huangbai liquid coating agent in burn treatment, explores its mechanism of promoting wound healing, evaluates its current advantages and limitations in burn treatment, and provides scientific basis and theoretical support for its better use in burn treatment.
High performance liquid chromatography (HPLC) is currently the mainstream technology for detecting hemoglobin. Glycated hemoglobin (HbA1c) is a gold indicator for diagnosing diabetes, however, the accuracy of HbA1c test is affected by thalassemia factor hemoglobin F (HbF)/hemoglobin A2 (HbA2) and variant hemoglobin during HPLC analysis. In this study, a new anti-interference hemoglobin analysis system of HPLC is proposed. In this system, the high-pressure three-gradient elution method was improved, and the particle size and sieve plate aperture in the high-pressure chromatography column and the structure of the double-plunger reciprocating series high-pressure pump were optimized. The system could diagnose both HbA1c and thalassemia factor HbF/HbA2 and variant hemoglobin, and the performance of the system was anti-interference and stable. It is expected to achieve industrialization. In this study, the HbA1c and thalassemia factor HbF/HbA2 detection performance was compared between this system and the world’s first-line brand products such as Tosoh G8, Bio-Rad Ⅶ and D10 glycosylated hemoglobin analysis system. The results showed that the linear correlation between this system and the world-class system was good. The system is the first domestic hemoglobin analysis system by HPLC for screening of HbA1c and thalassemia factor HbF/HbA2 rapidly and accurately.
ObjectiveTo study the pharmacokinetics of lovastatin/niacin sustained-release tablets in healthy Chinese volunteers. MethodsEligible subjects were enrolled to receive a single dose of 20/500, 20/750 and 20/1 000 mg lovastatin/niacin sustained-release tablets and multiple dose of 20/1 000 mg lovastatin/niacin sustainedrelease tablets, one time per day, sustained for 5 days, respectively. Blood samples were obtained before dosing and up to 10, 20, 30, and 45 minutes, and 1 hour, 1.5, 2, 2.5, 3, 3.5, 4, 5, 7, 9, 12, and 15 hours after dosing. Niacin, niacinamide, nicotinuric acid and lovastatin were detected by high performance liquid chromatography-tandem mass spectrometry method. ResultsThe peak concertration and the area under the plasma concentration-time curve (0-t) of nicotinuric acid had linear dynamics characteristics with the dosage when the dose of niacin was between 500 and 1 000 mg. After multiple dosing, pharmacokinetics parameters of nicotinuric acid and lovastatin were close. No significant diTherence was found between male and female subjects. ConclusionLovastatin/niacin sustained-release tablets possess linear kinetics. Accumulation is not significant after multiple dosing. Gender doesn't affect the pharmacokinetics parameters.
Objective To determine the best threshold value of hemoglobin A2 (HbA2) for diagnosis of β-thalassemia (β-thal) carriers by using high performance liquid chromatography (HPLC), and to improve the application value of HbA2 as a diagnostic index for β-thal carriers to reduce the rates of missed diagnosis and misdiagnosis. Methods Using reverse dot blot (RDB) as a gold standard method, HbA2 results of 1 007 β-thal carriers and 606 normal controls in the past two years determined by HPLC were divided into true positive, false positive, true negative, and false negative based on the different threshold values of HbA2 results. Then, the evaluation indexes such as sensitivity, specificity, positive and negative likelihood ratio, and Youden’s index were evaluated. Next, the receiver operator characteristic (ROC) curve was drawn to determine the best threshold value of HbA2 for diagnosis of β-thal carriers by HPLC. Results If ≥4.0% was taken as the threshold value of HbA2 for diagnosis of β-thal carriers by HPLC, the evaluation indexes values were shown as follows: sensitivity 99.21%, specificity 99.34%, positive likelihood ratio 150.30, negative likelihood ratio 0.008, and Youden’s index 0.99. The Youden’s index was better than the other threshold values, and the corresponding tangent point was the peak point of the ROC curve. Conclusion When ≥4.0% serves as the best threshold value of HbA2 for diagnosis of β-thal carriers using HPLC, integrated evaluation performance of the corresponding sensitivity and specificity is the most ideal, and the authenticity of the diagnostic test is the best.
Objective To study the degradable properties of 3D-SC artificial skin in vitro. Methods The 3D-SC artificial skin materials wererespectively immersed into the solutions of 0.9% normal saline (control group), pancreatic tissue liquid (experimental group 1), physiological buffer (Hanks balanced salt solution,experimental group 2) and 0.2 mol/L phosphate buffer (pH 7.4,experimentalgroup 3), and the degradation was carried out at 37℃. The quality lost ratioswere determined on the 3rd day, the 5th day, the 7th day, the 9th day, 11th dayand 14th day in the experimental group 1, while on the 3rd day, 7th day, 14th day, 15th day, 21st day and 30th day in the other groups. Results The 3D-SC artificial skin was degraded completely in pancreatic tissue liquid about within 14 days in the experimental group 1; in the control group, and in the experimental groups 2 and 3, the degradation ratios were 868%±2.30%,28.51%±10.68% and 7.35%±0.61% on the 14th day; 71.83%±2.58%, 91.32%±1.87% and 75.64%±6.13% on the 15th day, being significant difference between the control group and the experimental group 2(Plt;0.01); and 91.87%±8.15%, 95.62%±1.36% and 92.10%±2.26% on the 30th day, being no significant differences between these 3 groups(Pgt;0.05), respectivelies. Conclusion The 3D-SC artificial skin materials have good degradable properties. The trend of degradation speed is from slow to quick and then to slow without enzyme.