ObjectiveTo study the effect of titanium particles on the proliferation, differentiation, and cytomorphology of osteoblasts, and to explore the possible internal relations and mechanism. MethodsCalvarial osteoblasts were separated from 10 newborn Sprague Dawley rats by repeated enzyme digestion, and were cultured in vitro. The cells were identified by alkaline phosphatase (ALP) staining and alizarin red staining. The cells at passage 3 were cultured with titanium particles culture medium at concentrations of 0.01, 0.05, 0.1, 0.5, and 1 mg/mL (0.01, 0.05, 0.1, 0.5, and 1 mg/mL groups). The absorbance (A) values were detected by cell counting kit 8 at 7 days after cultured to compare the effect of titanium particles at different concentrations on proliferation, and median lethal concentration was screened out. The expression of collagen type I was detected by ELISA to observe the effect of titanium particles on differentiation. The osteoblasts co-cultured with titanium particles of median lethal concentration (experimental group) for 7 days, and double fluorescence staining with FITC-phalloidine and propidium iodide was performed. The cytomorphology variation of osteoblasts after swallowing titanium particles was observed under laser scanning confocal microscope. The osteoblasts at passage 3 cultured with culture medium without titanium particles served as control group. ResultsThe cultured cells were identified as osteoblasts by ALP staining and alizarin red staining. Different concentrations of titanium particles could inhibit osteoblasts proliferation and differentiation in varying degrees, showing significant difference when compared with the control group at 7 days after culture (P<0.05). The cell proliferation and differentiation were decreased with increased titanium particles concentration; significant differences were found between the other groups (P<0.05) except 0.01 and 0.05 mg/mL groups (P>0.05). The median lethal concentration of titanium particles was 0.5 mg/mL. Laser scanning confocal microscope showed cellular shrinking, microfilaments distortion, pseudopodia contraction of osteoblasts that swallowed titanium particles in the experimental group. ConclusionTitanium particles can inhibit proliferation and differentiation of osteoblasts. The effect may be related to variation of cytomorphology after swallowing titanium particles.
ObjectiveTo assess outcomes of transcatheter aortic valve replacement (TAVR) for pure native aortic valve regurgitation.MethodsA total of 129 patients underwent transfemoral TAVR in Fuwai Hospital from May 2019 to October 2020 were retrospectively analyzed. There were 83 males and 46 females with an average age of 72.26±8.97 years. The patients were divided into a pure native aortic valve regurgitation group (17 patients) and an aortic valve stenosis group (112 patients).ResultsThe incidence of valve in valve was higher in the pure native aortic valve regurgitation group (47.0% vs. 16.1%, P<0.01). There was no statistical difference between the two groups in conversion to surgery, intraoperative use of extracorporeal circulation, intraoperative left ventricular rupture, postoperative use of extracorporeal membrane oxygenation (ECMO), peripheral vascular complications, disabled stroke, death, or pacemaker implantation. There was no statistical difference in the diameter of annulus (25.75±2.21 mm vs. 24.70±2.90 mm, P=0.068) or diameter of outflow tract (25.82±3.75 mm vs. 25.37±3.92 mm, P=0.514) between the pure native aortic valve regurgitation group and the aortic valve stenosis group.ConclusionTransfemoral TAVR is a feasible method for patients with pure native aortic valve regurgitation. The diameter of annulus plane, the diameter of outflow tract and the shape of outflow tract should be evaluated.
ObjectiveTo study a deep learning-based dual-modality fundus camera which was used to study retinal blood oxygen saturation and vascular morphology changes in eyes with branch retinal vein occlusion (BRVO). MethodsA prospective study. From May to October 2020, 31 patients (31 eyes) of BRVO (BRVO group) and 20 healthy volunteers (20 eyes) with matched gender and age (control group) were included in the study. Among 31 patients (31 eyes) in BRVO group, 20 patients (20 eyes) received one intravitreal injection of anti-vascular endothelial growth factor drugs before, and 11 patients (11 eyes) did not receive any treatment. They were divided into treatment group and untreated group accordingly. Retinal images were collected with a dual-modality fundus camera; arterial and vein segments were segmented in the macular region of interest (MROI) using deep learning; the optical density ratio was used to calculate retinal blood oxygen saturation (SO2) on the affected and non-involved sides of the eyes in the control group and patients in the BRVO group, and calculated the diameter, curvature, fractal dimension and density of arteriovenous in MROI. Quantitative data were compared between groups using one-way analysis of variance. ResultsThere was a statistically significant difference in arterial SO2 (SO2-A) in the MROI between the affected eyes, the fellow eyes in the BRVO group and the control group (F=4.925, P<0.001), but there was no difference in the venous SO2 (SO2-V) (F=0.607, P=0.178). Compared with the control group, the SO2-A in the MROI of the affected side and the non-involved side of the untreated group was increased, and the difference was statistically significant (F=4.925, P=0.012); there was no significant difference in SO2-V (F=0.607, P=0.550). There was no significant difference in SO2-A and SO2-V in the MROI between the affected side, the non-involved side in the treatment group and the control group (F=0.159, 1.701; P=0.854, 0.197). There was no significant difference in SO2-A and SO2-V in MROI between the affected side of the treatment group, the untreated group and the control group (F=2.553, 0.265; P=0.088, 0.546). The ophthalmic artery diameter, arterial curvature, arterial fractal dimension, vein fractal dimension, arterial density, and vein density were compared in the untreated group, the treatment group, and the control group, and the differences were statistically significant (F=3.527, 3.322, 7.251, 26.128, 4.782, 5.612; P=0.047, 0.044, 0.002, <0.001, 0.013, 0.006); there was no significant difference in vein diameter and vein curvature (F=2.132, 1.199; P=0.143, 0.321). ConclusionArterial SO2 in BRVO patients is higher than that in healthy eyes, it decreases after anti-anti-vascular endothelial growth factor drugs treatment, SO2-V is unchanged.
ObjectiveTo investigate the morphology of coronal femoral intertrochanteric fracture and its effect on reduction and internal fixation.MethodsThe clinical and imaging data of 46 patients with femoral intertrochanteric fracture who met the selection criteria between August 2017 and October 2018 were reviewed. There were 15 males and 31 females; the age ranged from 62 to 91 years, with an average of 72.8 years. The causes of injury included walking falls in 35 cases, falling out of bed in 4 cases, and traffic accidents in 7 cases. The AO/Orthopaedic Trauma Association classification was type 31-A1 in 11 cases and type 31-A2 in 35 cases. All patients underwent closed reduction and internal fixation with intramedullary nails. During the operation, fracture reduction and fixation were performed according to the preoperative evaluation results. According to the patients’ preoperative X-ray film and CT three-dimensional reconstruction images, the direction of the coronal fracture line of the femoral intertrochanter and the morphological characteristics of the fracture block were observed; and the coronal fracture discrimination analysis was carried out for the fractures of different AO/OTA types. The percentages of coronal femoral intertrochanteric fractures diagnosed by preoperative X-ray film and CT three-dimensional reconstruction were calculated and statistically analyzed. The fracture reduction, the position of internal fixation [measurement of tip-apex distance (TAD)]. and the reliability of internal fixation were observed after operation.ResultsX-ray film was not easy to identify coronary fracture, and the coronal fracture line and the shape of the fracture piece weree clearly visible in CT three-dimensional reconstruction images. The morphological characteristics of the coronary fracture block: in AO/OTA 31-A1 type, the fracture line extended obliquely backward from the anterior tip of the large rotor, above the small rotor with or without small rotor fracture; in AO/OTA 31-A2 type, fracture line extended obliquely backward from the anterior tip of the large rotor to below the small rotor. Thirteen cases (28.3%) of coronal fractures were found on preoperative X-ray films, and 35 cases (76.1%) were found by CT three-dimensional reconstruction, showing significant difference (χ2=21.083, P=0.000). In AO/OTA 31-A1 type patients, the proportion of coronal fractures found by X-ray film and CT three-dimensional reconstruction was 18.2% (2/11) and 54.5% (6/11), respectively, and that in AO/OTA 31-A2 type patients was 31.4% (11/35) and 82.9% (29/35), respectively, showing significant differences (χ2=3.143, P=0.000; χ2=20.902, P=0.000). Among the 35 patients with coronal fractures, 6 cases (17.1%) of AO/OTA 31-A1 type, 29 cases (82.9%) of AO/OTA 31-A2 type. The operation time of the patient was 80-112 minutes, with an average of 95 minutes; the intraoperative blood loss was 180-450 mL, with an average of 360 mL. There was no complication such as infection, falling pneumonia, and deep vein thrombosis of the lower extremities. At 3 days after operation, the internal fixators were all in the proper position. The TAD was 0.9-1.8 cm, with an average of 1.4 cm. All patients were followed up 14-18 months, with an average of 16 months. All the fractures healed osseously, and there was no complication such as nonunion and loosening of internal fixation.ConclusionCT three-dimensional reconstruction can better identify coronal femoral intertrochanteric fractures than X-ray films, and accurately recognize and analyze the incidence and morphological characteristics of coronal fractures, which can help formulate more effective surgical strategies to promote patient recovery.
Objective To study the anteromedial cortical morphology of intertrochanteric fracture with CT three-dimensional reconstruction technique, and to provide a reference for further study of cortical buttress reduction theory. Methods CT data of 75 patients with unstable intertrochanteric fracture with complete imaging data treated between January 2016 and January 2019 were retrospectively analyzed, including 32 males and 43 females, aged 65-98 years (mean, 79.8 years). According to AO/Orthopaedic Trauma Association typing of 2018 edition, there were 46 cases of 31-A2.2 type and 29 cases of 31-A2.3 type. The image processing techniques such as segmentation modeling and virtual reset were performed. The thickness of the cortex at the anteromedial corner, the angle between the anterior wall fracture line and the coronal horizontal line, the angle between the medial wall fracture line and the sagittal horizontal line, the width of the cortex supported by the medial wall were measured, and the morphology of the cortical bone at the anteromedial corner were observed. Results The angle between the anterior wall fracture line and the coronal horizontal line was 51.8-72.6°, with an average of 62.4°; the angle between the medial wall fracture line and the sagittal horizontal line ranged from 17.6° to –47.3°, with an average of −15.8°; the thickness of the cortex at the anteromedial angle was 3.6-6.1 mm, with an average of 4.4 mm; and the width of the cortex supported by the medial wall was 14.3-21.2 mm, with an average of 16.8 mm. The morphology of the cortical bone at the anteromedial corner had 3 forms: angle with femoral neck axis >90°, 57 cases (76.0%); perpendicular to femoral neck axis, 7 cases (9.3%); angle with femoral neck axis <90° (including reverse angle), 11 cases (14.7%). Conclusion CT three-dimensional reconstruction can clearly show the cortical morphology and the direction of the fracture line of intertrochanteric fracture, which can indicate the stability of the intertrochanteric fracture after reduction, and has a good guiding on the form of cortical buttress reduction.
ObjectiveTo systematically review the effectiveness of traditional morphological embryo screening method and other screening methods. MethodsWe electronically searched PubMed, EMbase, Web of Knowledge, CBM, WanFang Data and CNKI, for studies about the effectiveness of traditional morphological embryo screening method and other screening methods from inception to July 1st, 2013. Two reviewers independently screened studies according to the inclusion and exclusion criteria, extracted data and evaluated the methodological quality of the included studies. Then meta-analysis was performed using the software RevMan 5.1. ResultsA total of 4 studies involving 951 patients were included. The results of meta-analysis showed that, for the traditional morphological embryo screening method, when compared with the NIR method and CCS method, there were no significant differences in clinical pregnancy rate (OR=0.94, 95%CI 0.57 to 1.53, P=0.80) and live birth rate (OR=0.90, 95%CI 0.60 to 1.37, P=0.63). However, significant difference was found for the embryos fragment rate (OR=0.40, 95%CI 0.27 to 0.59, P < 0.000 01). ConclusionThe current evidence shows that, compared with other methods, the traditional morphological embryo screening method could significantly reduce the embryos fragments rate. The results are needed to be further validate by more high-quality and large-scale studies.
OBJECTIVE: To establish the animal models of mandibular distraction osteogenesis in rabbits and study its osteogenetic mechanism. METHODS: The right mandibles just anterior to the first molars of 12 rabbits were performed osteotomies, and the mandibles were positioned with distractors. The left mandibles were control group without operation. After 1 week, the distractors were stretched 0.9 mm every day for 10 days progressively. One day, 2, 4, 8 weeks after distraction, the mandibles were studied with gross measurement, X-ray, and histological examination. RESULTS: The right mandible were lengthened 8.3 mm on average without bone nonunion and deformity healing. It was observed that the gaps between the distracted bone edges were first occupied by fibrous tissue. Two weeks after distraction, it was found that the gaps were bridged by callus in X-ray, the new bone and the normal bone could not be differentiated clearly after 8 weeks. In histological sections, there were collagen bundles in early distraction, then those collagen bundles were calcificated and become trabeculaes. No Cartilage was found during distraction. CONCLUSION: It suggests that the rabbit mandible can be lengthened by distraction osteogenesis, and the new bone is formed by intramembranous ossification.
In order to investigate the histological and stereological change of the rapidly expanded skin tube, 15 Japanese Long Ear Rabbits were divided into 3 groups: (1) Rapid expansion group, injecting once a day for 7 days; (2) Routine expansion group, injecting every 3 days for 21 days and (3) Control group, no expander implanted. The results showed that: in the rapid expansion group, the thickness of the epidermis and dermis were both increased, fibroblast proliferation was active, a large amount of new capillaries was observed, the collagen fiber was in loose type, and the mitochondria and rough endoplasmic net of epithelial cell were increased. In the routine expansion group, similar changes were observed. The vascular density and volume fraction were significantly higher in rapid expansion group than those in the control group (P lt; 0.05). It was concluded that the rapid expansion of skin tube was feasible.
ObjectiveTo explore the effect of false acetabulum on the development and anatomical morphology of proximal femur in Crowe type Ⅳ developmental dysplasia of the hip (DDH), providing a theoretical basis for the development of femoral reconstruction strategy and prosthesis selection for total hip arthroplasty. Methods The medical records of 47 patients (54 hips) with Crowe type Ⅳ DDH between February 2008 and March 2020 were retrospectively analyzed, of which 21 patients (26 hips) were Crowe type Ⅳa (type Ⅳa group) and 26 patients (28 hips) were Crowe type Ⅳb (type Ⅳb group). There was no significant difference in general data such as gender, age, height, weight, body mass index, and side between the two groups (P>0.05), which were comparable. The height of femoral head dislocation, the height of pelvis, and the proportion of dislocation were measured based on preoperative anteroposterior pelvic X-ray film. Based on the preoperative femoral CT scan data, the anatomical parameters of the femur and femoral medullary cavity were measured after three-dimensional reconstruction using Mimics19.0 software to calculate the canal fare index; and the femoral medullary cavity parameters were matched with the modular S-ROM prosthesis parameters. ResultsThe results of X-ray film measurement showed that the height of femoral head dislocation and the proportion of dislocation in type Ⅳa group were significantly higher than those in type Ⅳb group (P<0.05). There was no significant difference in the height of pelvis between the two groups (P>0.05). The results of CT three-dimensional reconstruction measurements showed that compared with the type Ⅳb group, the type Ⅳa group had less isthmus height, smaller femoral head, shorter femoral neck, narrower neck-shaft angle, increased anteversion angle, and higher greater trochanter, and the differences were significant (P<0.05). There was no significant difference in the height of femoral head, femoral offset, and height difference between greater trochanter and femoral head between the two groups (P>0.05). There was no significant difference in the mediolateral width (ML), anteroposterior width (AP), and diameter of the isthmus (Ci level) and the AP of the medullary cavity in the plane 40 mm distal to the most prominent point on the medial side of the lesser trochanter (C–40 level) (P>0.05), and the size of medullary cavity was significantly smaller in type Ⅳa group than in type Ⅳb group at the other levels (P<0.05). Compared with the type Ⅳb group, the difference between the outer diameter of the prosthetic sleeve and the diameter of the medullary cavity fitting circle in the plane where the center of femoral head rotation was located from the medial most prominent point of the lesser trochanter (C0 level) in type Ⅳa group was smaller, and the proportion of negative values was greater (P<0.05). The difference between the longest diameter of the prosthetic sleeve triangle and the ML of the medullary cavity in the plane 10 mm proximal to the most prominent point on the medial side of the lesser trochanter (C+10 level) in type Ⅳa group was smaller, and the proportion of negative values was greater (P<0.05). ConclusionFalse acetabulum has a significant impact on the morphology of the proximal femur and medullary cavity in patients with Crowe type Ⅳ DDH, and the application of three-dimensional reconstruction technique can accurately evaluate the femoral morphology and guide the selection of femoral prosthesis.
ObjectiveThe anatomical calcaneal external fixator was designed by measuring and calculating the morphological data of the heel.MethodsA total of 100 normal people were randomly selected to obtain 200 hind foot data, including 45 males and 55 females, with an average age of 43.9 years (range, 19-67 years). According to the principles of human engineering and local anatomy, the morphological data of the heel in the weight-bearing standing position and supine position were measured with the direct measurement mode. The heel length, heel width, heel height, medial ankle height, lateral ankle height, and calcaneal pitch angle (CPA) were measured by vernier calipers and ulnar markers in weight-bearing standing position, and the gender groups and left and right foot groups were compared; the shape of the hind foot in the supine position was measured by three-dimensional (3D) dot matrix inverse model method. According to the stereoscopic data of the comprehensive anatomical morphology of the heel, the anatomical calcaneal external fixator was designed with AutoCAD 2019 and other 3D industrial design softwares.ResultsThe measurements of shoe size, heel length, heel width, heel height, medial ankle height, lateral ankle height, and CPA in male were significantly higher than those in female (P<0.05). There was no significant difference between the left and right feet in the other indexes except that the height of the medial malleolus of the left foot was significantly lower than that of the right foot (t=−2.827, P=0.005). The measurement of 3D dot matrix inverse model in supine position showed that the heel part was non-circular arc edge, and many groups of arc edges fluctuate in a limited range. Based on the above data, an anatomical calcaneal external fixator was designed, which could fit the anatomic radian in theory, so as to be flexible in configuration. On this basis, the ordinary configuration, compression configuration, and orthodontic configuration were designed to meet the treatment needs of calcaneal fractures in different degrees. The ordinary configuration was suitable for patients with Sanders Ⅰ, ⅡA, and ⅡB calcaneal fractures with no or slight displacement of intra-articular fractures; the ordinary configuration was mainly used for simple fixing. The compression configuration was suitable for patients with Sanders ⅡC, ⅢA, and ⅢB, tongue fractures, and avulsion fractures with severe displacement of intra-articular fractures; the compression configuration used obliquely drawn console wires to fix the displaced bones. The orthodontic configuration was suitable for patients with Sanders ⅢC and Ⅳ calcaneal fractures with severe displacement of intra-articular fractures or severe calcaneal bone defects; the orthodontic configuration was a multi-module design, which took into account the stable fixation of the fracture and the arbitrary adjustment of the joint fixation angle.ConclusionThe hind foot is special for morphology, so the external fixator designed based on the vernier caliper measurement method and 3D dot matrix measuring plate measurement method is an anatomical type and its configuration can theoretically meet stable and flexible clinical needs.