find Keyword "numerical simulation" 17 results
  • Effect of arterial flow on muscle atrophy

    This study analyzed the inherent relation between arterial blood mass flow and muscle atrophy of residual limb to provide some necessary information and theoretical support for the clinical rehabilitation of lower limb amputees. Three-dimensional arterial model reconstruction was performed on both intact side and residual limb of a unilateral transfemoral amputee who is the subject. Then hemodynamic calculation was carried out to comparatively analyze the mass flow state at each arterial outlet of both lower extremities. The muscle atrophy ratio of residual limb was calculated by measuring the cross-sectional area of bilateral muscles. Based on the blood supply relationship, the correlation between arterial blood flow reduction ratio and muscle atrophy ratio was discussed. The results showed that the mass flow of superficial femoral arteries and lateral circumflex femoral arteries severely reduced. Meanwhile rectus femoris, vastus lateralis and vastus medialis which were fed by these arteries showed great atrophy too. On the contrary, the mass flow of deep femoral arteries and medial femoral circumflex arteries slightly reduced. Meanwhile gracilis, adductor longus, long head of biceps which were fed by these arteries showed mild atrophy too. These results indicated that there might be a positive and promotion correlation between the muscle atrophy ratio and the blood mass flow reduction ratio of residual limb during rehabilitation.

    Release date:2019-02-18 03:16 Export PDF Favorites Scan
  • Numerical simulation of the effect of virtual stent release pose on the expansion results

    The current finite element analysis of vascular stent expansion does not take into account the effect of the stent release pose on the expansion results. In this study, stent and vessel model were established by Pro/E. Five kinds of finite element assembly models were constructed by ABAQUS, including 0 degree without eccentricity model, 3 degree without eccentricity model, 5 degree without eccentricity model, 0 degree axial eccentricity model and 0 degree radial eccentricity model. These models were divided into two groups of experiments for numerical simulation with respect to angle and eccentricity. The mechanical parameters such as foreshortening rate, radial recoil rate and dog boning rate were calculated. The influence of angle and eccentricity on the numerical simulation was obtained by comparative analysis. Calculation results showed that the residual stenosis rates were 38.3%, 38.4%, 38.4%, 35.7% and 38.2% respectively for the 5 models. The results indicate that the pose has less effect on the numerical simulation results so that it can be neglected when the accuracy of the result is not highly required, and the basic model as 0 degree without eccentricity model is feasible for numerical simulation.

    Release date:2018-04-16 09:57 Export PDF Favorites Scan
  • Influence of Angle Variation between Right Hepatic Vein and Inferior Vena Cava on Inferior Vena Cava Diaphragm

    Computational fluid dynamics was used to investigate the effect of the pathogenesis of membranous obstruction of inferior vena cava of Budd-Chiari syndrome with various angles between right hepatic vein and inferior vena cava. Mimics software was used to reconstruct the models from magnetic resonance imaging (MRI) angiograms of inferior vena cava, right hepatic vein, middle hepatic vein and left hepatic vein, and 3DMAX was used to construct the models of 30°, 60°, 90° and 120° angles between right hepatic vein and inferior vena cava, which was based on the reconstructed models.The model was conducted with clinical parameters in terms of wall shear stress distribution, static pressure distribution and blood velocity. The results demonstrated that the differences between wall shear stress and static pressure had statistical significance with various angles between right hepatic vein and inferior vena cava by SPSS. The pathogenesis of membranous obstruction of inferior vena cava had a correlation with the angles between right hepatic vein and inferior vena cava.

    Release date: Export PDF Favorites Scan
  • Biomechanical models and numerical studies of atherosclerotic plaque

    Atherosclerosis is a complex and multi-factorial pathophysiological process. Researches over the past decades have shown that the development of atherosclerotic vulnerable plaque is closely related to its components, morphology, and stress status. Biomechanical models have been developed by combining with medical imaging, biological experiments, and mechanical analysis, to study and analyze the biomechanical factors related to plaque vulnerability. Numerical simulation could quantify the dynamic changes of the microenvironment within the plaque, providing a method to represent the distribution of cellular and acellular components within the plaque microenvironment and to explore the interaction of lipid deposition, inflammation, angiogenesis, and other processes. Studying the pathological mechanism of plaque development would improve our understanding of cardiovascular disease and assist non-invasive inspection and early diagnosis of vulnerable plaques. The biomechanical models and numerical methods may serve as a theoretical support for designing and optimizing treatment strategies for vulnerable atherosclerosis.

    Release date:2021-02-08 06:54 Export PDF Favorites Scan
  • Structural design and biomechanical numerical analysis of body-fitted stent in stenotic vessels

    To solve the problem of stent malapposition of intravascular stents, explore the design method of intravascular body-fitted stent structure and to establish an objective apposition evaluation method, the support and apposition performance of body-fitted stent in the stenotic vessels with different degrees of calcified plaque were simulated and analyzed. The traditional tube-mesh-like stent model was constructed by using computational aided design tool SolidWorks, and based on this model, the body-fitted stent model was designed by means of projection algorithm. Abaqus was used to simulate the crimping-expansion-recoil process of the two stents in the stenotic vessel with incompletely calcified plaque and completely calcified plaque respectively. A comprehensive method for apposition evaluation was proposed considering three aspects such as separation distance, fraction of non-contact area and residual volume. Compared with the traditional stent, the separation distances of the body-fitted stent in the incompletely calcified plaque model and the completely calcified plaque model were decreased by 21.5% and 22.0% respectively, the fractions of non-contact areas were decreased by 11.3% and 11.1% respectively, and the residual volumes were decreased by 93.1% and 92.5% respectively. The body-fitted stent improved the apposition performance and was effective in both incompletely and completely calcified plaque models. The established apposition performance evaluation method of stent considered more geometric factors, and the results were more comprehensive and objective.

    Release date:2021-12-24 04:01 Export PDF Favorites Scan
  • Progress on numerical simulation of the deposition of inhaled particles in human pulmonary acinus region

    The inhalation and deposition of particles in human pulmonary acinus region can cause lung diseases. Numerical simulation of the deposition of inhaled particles in the pulmonary acinus region has offered an effective gateway to the prevention and clinical treatment of these diseases. Based on some important affecting factors such as pulmonary acinar models, model motion, breathing patterns, particulate characteristics, lung diseases and ages, the present research results of numerical simulation in human pulmonary acinus region were summarized and analyzed, and the future development directions were put forward in this paper, providing new insights into the further research and application of the numerical simulation in the pulmonary acinus region.

    Release date:2019-06-17 04:41 Export PDF Favorites Scan
  • Research progress in computational fluid dynamics simulation of alveolar airflows

    Due to their diverse types, complex causes, high incidence, and difficult treatment, lung diseases have become major killers threatening human life and health, and some lung diseases have a significant impact on alveolar morphology and histology. Numerical simulation of alveolar mechanical response, alveolar flow field information, multiphase flow, and material transport based on computational fluid dynamics is of great significance for lung disease diagnosis, clinical treatment, and in vitro experiments. Starting from the simplification and pathological differences of geometric and mechanical models, this paper analyzes and summarizes the conditions and application scenarios of the airflow dynamics calculation method in pulmonary alveoli, to provide a reference for further simulation and application of the alveolar region.

    Release date:2023-08-24 10:24 Export PDF Favorites Scan
  • Progress in numerical simulation and experimental study on inhalable particles deposition in human respiratory system

    Inhalable particles deposition in the human respiratory system is the main cause of many respiratory and cardiovascular diseases. It plays an important role in related disease prevention and treatment through establishing computer or external entity models to study rules of particle deposition. The paper summarized and analyzed the present research results of various inhalable particle deposition models of upper respiratory tract and pulmonary area, and expounded the application in the areas of disease inducement analysis, drug inhale treatment etc. Based on the review, the paper puts forward the problems and application limitations of present research, especially pointing out future emphasis in development directions. It will have a value of reference guidance for further systematic and in-depth study on the inhalable particle deposition simulation, experiment and application.

    Release date:2017-08-21 04:00 Export PDF Favorites Scan
  • Numerical study on the mechanical coupling of external vascular stent and vein graft in coronary artery bypass surgery

    External support stent is a potential means for restricting the deformation and reducing wall stress of the vein graft, thereby improving the long-term patency of the graft in coronary artery bypass surgery. However, there still lacks a theoretical reference for choosing the size of stent based on the diameter of graft. Taking the VEST (venous external support) stent currently used in the clinical practice as the object of study, we constructed three models of VEST stents with different diameters and coupled them respectively to a model of the great saphenous vein graft, and numerically simulated the expansion-contraction process of the vein graft under the constraint of the stents to quantitatively evaluate the influence of stent size on the radial deformation and wall stress of the vein graft. The results showed that while the stent with a small diameter had a high restrictive effect in comparison with larger stents, it led to more severe concentration of wall stress and sharper changes in radial deformation along the axis of the graft, which may have adverse influence on the graft. In order to solve the aforementioned problems, we ameliorated the design of the stent by means of changing the cross-sectional shape of the thick and thin alloy wires from circle into rectangle and square, respectively, while keeping the cross-sectional areas of alloy wires and stent topology unchanged. Further numerical simulations demonstrated that the ameliorated stent evidently reduced the degrees of wall stress concentration and abrupt changes in radial deformation, which may help improve the biomechanical environment of the graft while maintaining the restrictive role of the stent.

    Release date:2021-02-08 06:54 Export PDF Favorites Scan
  • Numerical simulation and performance analysis of mixed flow blood pump

    The high rotational speed of the axial flow blood pump and flow separation of the centrifugal blood pump are the main causes for blood damage in blood pump. The mixed flow blood pump can effectively alleviate the high rotational speed and the flow separation. Based on this, the purpose of this study is to explore the performance of the mixed blood pump with a closed impeller. A mixed flow blood pump with closed impeller was studied by numerical simulation in this paper. The flow field characteristics and the pressure distribution of this type of blood pump were analyzed. The hydraulic performance of the blood pump and the possible damages to red blood cells were also discussed. At last, pump performance was compared with the mixed flow blood pump with semi-open impeller. The results show that the mixed flow blood pump with close impeller studied in this paper can operate safely and efficiently with a good performance. The pump can reach the pressure head of 100 mmHg at 5 L/min mass flow rate. Flow in the blood pump is uniform and no obvious separation or vortex occurs. Pressure distribution in and on the impeller is uniform and reasonable, which can effectively avoid the thrombosis of blood. The average mean value of hemolysis index is 4.99 × 10−4. The pump has a good biocompatibility. Compared with the mixed flow blood pump with semi-open impeller, the mixed flow blood pump with closed impeller has higher head and efficiency, a smaller mean value of hemolysis index prediction, a better hydraulic performance and the ability to avoid blood damage. The results of this study may provide a basis for the performance evaluation of the closed impeller mixed flow blood pump.

    Release date:2020-06-28 07:05 Export PDF Favorites Scan