ObjectiveTo investigate the mid-term effectiveness of three‐dimensional (3D) printed osteotomy guide plate and personalized prosthesis in knee‐preserving tumor resection. Methods The clinical data of 12 patients who underwent knee‐preserving tumor resection and reconstruction with 3D printed osteotomy guide plate and personalized prosthesis between September 2016 and October 2018 were retrospectively analyzed. There were 7 males and 5 females. The age ranged from 7 to 59 years, with a median of 44.5 years. There were 11 cases of osteosarcoma and 1 case of fibrosarcoma, all of which were Enneking grade ⅡB. The distance from the tumor to the joint surface was 5.5-8.2 cm, with an average of 6.94 cm. Incision healing, tumor recurrence, periprosthetic fracture, and aseptic loosening were observed after operation. The Musculoskeletal Tumor Society (MSTS) scoring system was used to evaluate the function of the patients, and the knee flexion range of motion was measured. ResultsThe 12 patients were followed up 41-66 months, with an average of 54.5 months. The length of osteotomy ranged from 14 to 26 cm, with an average of 22.08 cm. Except for 2 patients with superficial infection of incision tissue, no deep infection involving the prosthesis occurred, no patient underwent revision surgery because of prosthesis infection. During the follow-up, local recurrence occurred in 2 cases and distant metastasis occurred in 3 cases. The overall disease-free survival rate was 58.3%. Two patients died of lung metastasis, and the overall survival rate was 83.3%. One patient underwent amputation due to local recurrence, and 1 patient underwent total knee arthroplasty due to prosthesis rupture. No aseptic loosening of the prosthesis and periprosthetic fracture occurred during the follow-up, and the overall prosthesis survival rate was 83.3%. At last follow-up, 10 patients obtained satisfactory knee flexion range of motion that ranged from 95° to 125°, with an average of 110°. Two children could not cooperate with early rehabilitation treatment due to pain, and the knee flexion range of motion was not ideal (50°, 75°). All patients achieved acceptable lower limb function with MSTS scores ranged from 26 to 30, with an average of 28. All patients walked without crutches. ConclusionThe treatment of malignant bone tumors around the knee joint with 3D printed osteotomy guide plate and personalized prosthesis can preserve the articular surface, obtain good limb function, reduce the risk of aseptic loosening of prosthesis, and achieve better mid-term effectiveness.
Objective To explore the feasibility and early effectiveness of computer-simulated osteotomy based on the health-side combined with guide plate technique in the treatment of cubitus varus deformity in adolescents. Methods The clinical data of 23 patients with cubitus varus deformity who met the selection criteria between June 2019 and February 2023 were retrospectively analyzed. There were 17 males and 6 females, ranging in age from 4 to 16 years with an average of 8.5 years. The time from injury to operation was 1-4 years. The angle of distal humerus rotation was defined by humeral head posterior inclination angle using low radiation dose CT to scan the patient’s upper extremity data at one time, and the preoperative rotation of the distal humerus on the affected side was (33.82±4.39)°. The CT plain scan data were imported into 9yuan3D digital orthopaedic system (V3.34 software) to reconstruct three-dimensional images of both upper extremities. The simulated operation was performed with the healthy upper extremity as the reference, the best osteotomy scheme was planned, overlapped and compared, and the osteotomy guide plate was prepared. The patients were followed up regularly after operation, and the formation of callus in the osteotomy area was observed by X-ray examination. Before and after operation, the carrying angle of both upper extremities (the angle of cubitus valgus was positive, and the angle of cubitus varus was negative) and anteversion angle were measured on X-ray and CT images. At the same time, the flexion and extension range of motion of elbow joint and the external rotation range of motion of upper extremity were measured, and Mayo score was used to evaluate the function of elbow joint. ResultsThe operation time ranged from 34 to 46 minutes, with an average of 39 minutes. All patients were followed up 5-26 months, with a mean of 14.9 months. All the incisions healed by first intention after the operation; 2 patients had nail path irritation symptoms after Kirschner wire fixation, which improved after dressing change; no complication such as breakage and loosening of internal fixators occurred after regular X-ray review. Continuous callus formed at the osteotomy end at 4 weeks after operation, and the osteotomy end healed at 8-12 weeks after operation. At last follow-up, the carrying angle, anteversion angle, external rotation range of motion, and extension and flexion range of motion of the elbow joint of the affected side significantly improved when compared with preoperative ones (P<0.05). Except for the extension range of motion of the healthy elbow joint (P<0.05), there was no significant difference in other indicators between the two sides (P>0.05). At last follow-up, the Mayo elbow score was 85-100, with an average of 99.3; 22 cases were excellent, 1 case was good, and the excellent and good rate was 100%. ConclusionComputer-simulated osteotomy based on health-side combined with guide plate technique for treating cubitus varus deformity in adolescents can achieve precise osteotomy, which has the advantages of short operation time and easy operation, and the short-term effectiveness is satisfactory.
ObjectiveTo investigate the effectiveness of digital three-dimensional (3D) printing osteotomy guide plate assisted total knee arthroplasty (TKA) in treatment of knee osteoarthritis (KOA) patients with femoral internal implants. Methods The clinical data of 55 KOA patients who met the selection criteria between July 2021 and October 2023 were retrospectively analyzed. Among them, 26 cases combined with femoral implants were treated with digital 3D printing osteotomy guide plate assisted TKA (guide plate group), and 29 cases were treated with conventional TKA (control group). There was no significant difference in gender, age, body mass index, side, Kellgren-Lawrence classification, preoperative visual analogue scale (VAS) score, Hospital for Special Surgery (HSS) knee score, knee range of motion, and other baseline data between the two groups (P>0.05). The operation time, intraoperative blood loss, incision length, postoperative first ambulation time, surgical complications; VAS score, knee HSS score, knee range of motion before operation, at 1 week and 3 months after operation, and at last follow-up; distal femoral lateral angle, proximal tibial medial angle, hip-knee-ankle angle and other imaging indicators at last follow-up were recorded and compared between the two groups. ResultsThe operation time, incision length, intraoperative blood loss, and postoperative first ambulation time in the guide plate group were significantly lower than those in the control group (P<0.05). In the control group, there were 1 case of incision rupture and bleeding and 1 case of lower limb intermuscular venous thrombosis, which was cured after symptomatic treatment. There was no complication such as neurovascular injury, incision infection, or knee prosthesis loosening in both groups. Patients in both groups were followed up 12-26 months, with an average of 16.25 months. The VAS score, HSS score, and knee range of motion improved at each time point after operation in both groups, and further improved with time after operation, the differences were significant (P<0.05). The above indicators in the guide plate group were significantly better than those in the control group at 1 week and 3 months after operation (P<0.05), and there was no significant difference between the two groups at last follow-up (P>0.05). At last follow-up, the distal femoral lateral angle, the proximal tibial medial angle, and the hip-knee-ankle angle in the guide plate group were significantly better than those in the control group (P<0.05). Conclusion The application of digital 3D printing osteotomy guide plate assisted TKA in the treatment of KOA patients with femoral implants can simplify the surgical procedures, overcome limitations of conventional osteotomy guides, reduce surgical trauma, achieve individualized and precise osteotomy, and effectively restore lower limb alignment and knee joint function.
ObjectiveTo explore the biomechanical characteristics and clinical application effects of three-dimensional (3D) printed osteotomy guide plate combined with Ilizarov technique in the treatment of rigid clubfoot. Methods A retrospective analysis was performed on the clinical data of 11 patients with rigid clubfoot who met the inclusion criteria and were admitted between January 2019 and December 2024. There were 6 males and 5 females, aged 21-60 years with an average of 43.2 years. Among them, 5 cases were untreated congenital rigid clubfoot, 4 cases were recurrent rigid clubfoot after previous treatment, and 2 cases were rigid clubfoot due to disease sequelae. All 11 patients first received slow distraction using Ilizarov technique combined with circular external fixator until the force lines of the foot and ankle joint were basically normal. Then, 1 male patient aged 24 years was selected, and CT scanning was used to obtain imaging data of the ankle joint and foot. A 3D finite element model was established and validated using the plantar stress distribution nephogram of the patient. After validation, the biomechanical changes of the tibiotalar joint under the same load were simulated after triple arthrodesis and fixation. The optimal correction angle of the hindfoot was determined to fabricate 3D-printed osteotomy guide plates, and all 11 patients underwent triple arthrodesis using these guide plates. The functional recovery was evaluated by comparing the American Orthopaedic Foot and Ankle Society (AOFAS) score, International Clubfoot Study Group (ICFSG) score, and 36-Item Short Form Survey (SF-36) score before and after operation. Results Finite element analysis showed that the maximum peak von Mises stress of the tibiotalar joint was at hindfoot varus 3° and the minimum at valgus 6°; the maximum peak von Mises stress of the 3 naviculocuneiform joints under various conditions appeared at lateral naviculocuneiform joint before operation, and the minimum appeared at lateral naviculocuneiform joint at neutral position 0°; the maximum peak von Mises stress of the 5 tarsometatarsal joints under various conditions appeared at the 2nd tarsometatarsal joint at hindfoot neutral position 0°, and the minimum appeared at the 1st tarsometatarsal joint at valgus 6°. Clinical application results showed that the characteristics of clubfoot deformity observed during operation were consistent with the preoperative 3D reconstruction model. All 11 patients were followed up 8-24 months with an average of 13.1 months. One patient had postoperative incision exudation, which healed after dressing change; the remaining patients had good incision healing. All patients achieved good healing of the osteotomy segments, with a healing time of 3-6 months and an average of 4.1 months. At last follow-up, the AOFAS score, SF-36 score, and ICFSG score significantly improved when compared with those before operation (P<0.05). ConclusionThe 3D-printed osteotomy guide plate combined with Ilizarov technique has favorable biomechanical advantages in the treatment of rigid clubfoot, with significant clinical application effects. It can effectively improve the foot function of patients and achieve precise and personalized treatment.