west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "pelvic" 64 results
  • Effect of percutaneous kyphoplasty on lumbar-pelvic correlation in osteoporotic vertebral compressive fractures

    ObjectiveTo explore the effect of percutaneous kyphoplasty (PKP) on lumbar-pelvic correlation in osteoporotic vertebral compressive fracture (OVCF).MethodsAccording to the inclusion criteria, 63 patients with primary osteoporosis between January 2012 and June 2017 were selected as the control group and 67 patients with single-segment lumbar OVCF receiving PKP and complete clinical data were included as the observation group. There was no significant difference in gender, age, and lumbar spine bone density between the two groups (P>0.05). The visual analogue scale (VAS) score and Oswestry Disability Index (ODI) score were used to assess lumbar pain and function before operation and at 3 days after operation in the observation group; lumbar lordosis (LL), pelvic incidence (PI), pelvic tilt (PT), and sacral slope (SS) were measured in lumbar lateral X-ray films which were taken before PKP and at 1 month after PKP. The same parameters were measured in the lumbar lateral X-ray films which were taken at the time of initial diagnosis in the control group.ResultsAll patients were followed up 3-24 months with an average of 5.8 months in the observation group. The VAS score decreased from 5.6±1.8 before PKP to 2.8±1.3 at 3 days after PKP (t=14.082, P=0.000); ODI decreased from 50.1%±5.0% before PKP to 18.2%±1.8% (t=47.011, P=0.000). Compared with the control group, the LL, PI, and SS decreased and the PT increased in the observation group, and only the difference in LL between the two groups was significant (P<0.05). In the observation group, the LL and SS significantly increased (P<0.05) and PT significantly decreased (P<0.05) at 1 month after operation when compared with preoperative ones, and PI decreased, but the difference was not significant (P>0.05). In the control group, LL was positively correlated with PI and SS (P<0.05); PI was positively correlated with PT and SS (P<0.05). In the observation group, PI was positively correlated with SS (P<0.05) before and after PKP.ConclusionOVCF patients lost the specific lumbar-pelvic correlation. PKP can restore lumbar lordosis, but it still can not restore the normal physiological fitting.

    Release date:2019-11-21 03:35 Export PDF Favorites Scan
  • Research progress of pubic symphysis diastasis

    Objective To review the research progress of pubic symphysis diastasis and provide effective reference for orthopedic surgeons in the diagnosis and treatment of pubic symphysis diastasis. MethodsThe anatomy, injury mechanism, treatment, and other aspects of pubic symphysis diastasis were summarized and analyzed by reviewing the relevant research literature at domestically and internationally in recent years. ResultsThe incidence of pubic symphysis diastasis is high in pelvic fractures, which is caused by the injury of the ligaments and fibrocartilage disc around the pubic symphysis by external force. The treatment plan should be individualized according to the pelvic stability and the needs of patients, aiming to restore the stability and integrity of the pelvis and improve the quality of life of patients after surgery. ConclusionAt present, the research on pubic symphysis diastasis still needs to be improved. In the future, high-quality, multi-center, and large-sample studies are of great significance for the selection of treatment methods and the evaluation of effectiveness for patients with pubic symphysis diastasis.

    Release date:2023-12-12 05:09 Export PDF Favorites Scan
  • The disputes in the radiographic measurements of sagittal balance and how to deal with them

    Objective To review the process of radiographic measurements of sagittal balance and offer reference for the clinical practice. Methods The related literature of spino-pelvic sagittal parameters and their clinical application was reviewed and analyzed from the aspects such as the clinical application, the advantages and disadvantages, and how to use them effectively. Results All parameters have their advantages and disadvantages, and they are influenced by age and race. Sagittal vertical axis can only reflect the global balance, and T1 pelvic angle which accounts for both spinal inclination and pelvic tilt can’t be controlled in the surgery. The correction goal for western people may be not suitable for Chinese. Conclusion The parameters should be used wisely when evaluating the sagittal balance, the global balance and local balance should be considered together and the different groups of people need different correction goals.

    Release date:2018-10-31 09:22 Export PDF Favorites Scan
  • Evaluation of closed multi-axial screws iliosacral fixation system combined with posterior segmental spinal fixation for treatment of unstable sacral fractures

    Objective To evaluate the effectiveness of lumbopelvic fixation using the combination of closed multi-axial screws (CMAS) iliosacral fixation system and the posterior segmental spinal fixation for unstable sacral fractures. Methods Between January 2013 and November 2014, 25 patients (39 sides) with unstable sacral fractures were treated with lumbopelvic fixation using the combination of CMAS iliosacral fixation system and the posterior segmental spinal fixation. There were 17 males and 8 females, aged 19-55 years (mean, 33.9 years). The causes were traffic accident injury in 15 cases, falling injury from height in 8 cases, and crushing injury in 2 cases. The interval of injury and operation was 1-13 days (mean, 3.5 days). Fracture was classified as Denis type I in 2 sides, type II in 20 sides, and type III in 17 sides; nerve injury was rated as Gibbons grade I in 2 cases, grade II in 2 cases, grade III in 7 cases, and grade IV in 9 cases. The reduction quality was evaluated by Matta criterion, the clinical function outcome by Majeed, and nerve function by Gibbons criterion. Results The average operation time was 110 minutes (range, 80-150 minutes). The average blood loss was 570 mL (range, 250-1 400 mL). Superficial wound infection occurred in 2 patients, and was cured after debridement and antibiotic therapy. All patients were followed up for an average of 18 months (range, 15-22 months). Postoperative X-ray and CT examination showed clinical healing of sacral fractures at 8-12 weeks after operation (mean, 10 weeks). The mean removal time of internal fixation was 13 months (range, 12-20 months). No screw loosening and fracture, adhesion of internal fixation to surrounding tissue, and obvious electrolysis phenomenon occurred. According to Matta criterion, reduction was rated as excellent in 32 sides, good in 6 sides, fair in 1 side, and the excellent and good rate was 97.5%. According to Majeed functional scoring at last follow-up, the mean score was 84.7 (range, 64-98); the results were excellent in 18 cases, good in 5 cases, and fair in 2 cases, and the excellent and good rate was 92.0%. The nerve function was significantly improved when compared with preoperative one; nerve injury was rated as Gibbons grade I in 8 cases, grade II in 8 cases, grade III in 3 cases, and grade IV in 1 case. Conclusion Lumbopelvic fixation using the combination of CMAS iliosacral fixation system and the posterior segmental spinal fixation is a relatively effective fixation for unstable sacral fractures. Not only is the fracture fixation rigid for early full weight-bearing, but also nerve decompression can be performed which facilitates nerve function recovery.

    Release date:2017-04-01 08:56 Export PDF Favorites Scan
  • Evaluation of pelvic floor muscle structure and function by transluminal dual plane ultrasound

    Objective To explore the feasibility of transluminal dual plane ultrasound (TDPU) in evaluating the structure and function of pelvic floor muscle. Methods Non anorectal diseases patients who visited the Department of Medical Ultrasound, West China Hospital of Sichuan University, medical staff and medical staff’s relatives volunteers between May and November 2022 were selected. According to the criteria for ultrasound diagnosis of pelvic organ prolapse (POP) and the pelvic organ prolapse quantification (POP-Q) scoring criteria, the subjects were divided into normal group and POP group. The changes of the thickness of the left and right puborectalis muscle (PRM), the internal anal sphincter (IAS) and the external anal sphincter (EAS) at 3-, 6- and 9-o’clock, the depth and height of the perineal body (PB) were compared, and the changes of the elastic Young’s modulus of PRM, EAS and PB were compared through real-time shear wave elastography. Results A total of 192 subjects were included, including 140 in the normal group and 52 in the POP group. There were statistically significant differences between the POP group and the normal group in terms of gestational frequency, parity, and history of vaginal delivery (P<0.05). There was no statistically significant difference in age, body mass index, menopausal history, and neonatal weight between the two groups (P>0.05). Under the condition of resting and maximum anal constriction, the thickness of PRM on the left and right sides of POP group was not significantly different from that of the normal group (P>0.05), but the elastic Young’s modulus of PRM on the left and right sides were lower than that of the normal group (P<0.05). At resting and maximum anal constriction, there was no significant difference in IAS thickness between the POP group and the normal group at 3-, 6- and 9-o’clock (P>0.05). At resting and maximum anal constriction, the thickness of deep and subcutaneous parts of EAS at 6-o’clock and the subcutaneous part of EAS at 9-o’clock in the POP group were smaller than those in the normal group (P<0.05). At resting and maximum anal constriction, the elastic Young’s modulus of EAS at 3-, 6- and 9-o’clock were lower than those in the normal group (P<0.05). There was no significant difference in the depth and height of PB between the POP group and the normal group at resting and maximum anal constriction (P>0.05). The elastic Young’s modulus of PB in the POP group was lower than that of the normal group (P<0.05). Under the condition of maximum anal constriction, the thickness of deep and subcutaneous parts of EAS at 3-o’clock in the POP group were lower than those in the normal group (P<0.05). Conclusion TDPU can quantitatively evaluate the structure and function of pelvic floor muscle through different states of resting and maximum anal constriction, and also can provide ultrasonic basis for the diagnosis and treatment of female pelvic floor dysfunction diseases.

    Release date:2023-04-24 08:49 Export PDF Favorites Scan
  • Orthopedic robot based on 5G technology for remote navigation of percutaneous screw fixation in pelvic and acetabular fractures

    Objective To investigate the accuracy and safety of percutaneous screw fixation for pelvic and acetabular fractures with remote navigation of orthopedic robot based on 5G technology. Methods Between January 2021 and December 2021, 15 patients with pelvic and/or acetabular fractures were treated with percutaneous screws fixation which were placed by remote navigation of orthopedic robot based on 5G technology. There were 8 males and 7 females. The age ranged from 20 to 98 years, with an average of 52.1 years. The causes of trauma included traffic accident injury in 6 cases, falling from height injury in 6 cases, fall injury in 2 cases, and heavy object smashing injury in 1 case. The time from injury to operation ranged from 3 to 32 days, with an average of 10.9 days. There were 8 cases of simple pelvic fractures, 2 simple acetabular fractures, and 5 both pelvic and acetabular fractures. There were 7 cases of pelvic fractures of Tile type B2, 2 type B3, 1 type C1, and 3 type C2; 4 cases of unilateral anterior column fracture of the acetabulum, 2 bilateral anterior column fractures, and 1 anterior wall fracture. CT images within 5 days after operation were collected for screw position assessment. The screw planning time and guidewire placement time were recorded, as well as the presence of intraoperative adverse events and complications within 5 days after operation. Results All patients achieved satisfactory surgical results. A total of 36 percutaneous screws were inserted (20 sacroiliac screws, 6 LC Ⅱ screws, 9 anterior column screws, and 1 acetabular apical screw). In terms of screw position evaluation, 32 screws (88.89%) were excellent and 4 screws (11.11%) were good; there was no screw penetrating cortical bone. The screw planning time ranged from 4 to 15 minutes, with an average of 8.7 minutes. The guidewire placement time ranged from 3 to 10 minutes, with an average of 6.8 minutes. The communication delayed in 2 cases, but the operation progress was not affected, and no serious intraoperative adverse events occurred. No delayed vascular or nerve injury, infection, or other complications occurred within 5 days after operation. No cases need surgical revision. ConclusionThe fixation of pelvic and acetabular fractures by percutaneous screw with remote navigation of orthopedic robot based on 5G technology is accurate, safe, and reliable.

    Release date:2022-08-29 02:38 Export PDF Favorites Scan
  • Magnetic Resonance Imaging in Female Pelvic Masses:A Meta-Analysis

    Objective To evaluate the sensitivity, specificity, and accuracy of magnetic resonance imaging (MRI) in characterizing adnexal masses. Methods The databases such as the Cochrane Library, PubMed, EMbase, CNKI, and WanFang Data were searched on computer from 1991 to 2011. The reviewers screened the trials according to inclusion and exclusion criteria strictly, extracted the data, and assessed the methodology quality. Meta-analysis were performed using the Metadisc 1.40 software. The acquired pooled sensitivity, specificity, and summary receiver operating characteristic curve (SROC) were used to describe the diagnostic value. The pooled likelihood ratios were calculated based on the pooled sensitivity and specificity. Results Ten case-control studies involving 649 women who were suspected to have pelvic masses were included and 729 masses were confirmed by the postoperative histopathology. The pooled statistical results of meta-analysis showed that:the sensitivity and specificity of MRI were 〔89%(84%-92%), P=0.046 6〕 and 〔87% (83%-90%), P=0.000 2〕 respectively, the positive and negative likelihood ratios of MRI were 6.25(P=0.008 5) and 0.14(P=0.029 1) respectively, and the area under the SROC curve (AUC) was 0.941. The sensitivity and specificity of ultrasound were 〔87%(82%-91%), P=0.000 0〕 and 〔73%(69%-77%), P=0.000 0〕 respectively, the positive and negative likelihood ratios of MRI were 3.07(P=0.000 0) and 0.18(P=0.000 1) respectively, and the AUC was 0.897. The speci?city and accuracy of MRI in characterizing female pelvic masses were higher than ultrasound obviously. Conclusion According these evidences, the MRI should be recommended to the women who are suspected to have pelvic masses as a preferred.

    Release date:2016-09-08 10:36 Export PDF Favorites Scan
  • BIOMECHANICAL RESEARCH ON INTERNAL FIXATION METHODS OF POSTERIOR PELVIC RING FRACTURE DISLOCATION

    Objective To investigate the biomechanical differences of three internal fixation approaches, namely improved Galveston (IG), reconstruction plate (RP), and il iosacral screw (LS) to the posterior pelvic ring fracture dislocation and provide experimental evidence for the cl inical appl ication of proper internal fixation method. Methods Six donatedfresh adult cadaver pelvic specimens (age averaged 45 years old) were numbered randomly and their normal biomechanics were tested by the measure instrument (MTS855 Mini-Blonix). The displacement values of normal pelvis were measured under the vertical compression (800 N) and reverse direction compression (8 N·m). Then they were made into left Denis I pelvic fracture and fixed with the IG, RP, and LS, respectively, in different orders. Biomechanics test was conducted on the fixed pelvis from both the vertical and the reversed directions. Results Concerning the direction of vertical ity and torsion, the order of fracture displacement from small to large was the normal pelvis, LS, IG and RP. There was no significant difference between LS and the normal pelvis (P gt; 0.05), and the differences between other tow groups were significant (P lt; 0.05). Conclusion The LS fixation can provide better stabil ity for posterior pelvic ring fracture dislocation when compared with IG and RP.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
  • Retroperitoneal laparoscopic dismembered pyeloplasty for ureteropelvic junction obstruction

    Objective To investigate the clinical effect of retroperitoneal laparoscopic dismembered pyeloplasty on ureteropelvic junction obstruction (UPJO). Methods From November 2010 to September 2015, a total of 28 cases (21 males and 7 females) with ureteropelvic junction obstruction (UPJO) underwent retroperitoneal laparoscopic dismembered pyeloplasty. All the 28 patients had a previous history of different degrees of lumbar pain, which was confirmed as typical UPJO by imaging examination. Operation method: following complete renal pelvis and upper ureter isolation, the renal pelvis was clipped into a trumpet-shaped mouth, 1/3 of the upper renal pelvis was temporarily kept without section. In the inferior margin of renal pelvis, longitudinal cut procedure was operated in the ureter and across the stenotic segment in about 1–2 cm; and then, anastomosis of the ureter and the renal pelvis at the lowest was performed, to maintain the continuity of the renal pelvis and ureter. Subsequently, the stenosed segment of ureter and the dilatant renal pelvis were removed, the posterior ureteropelvic anastomosis was made with an interrupted suture, and antegrade stenting of double J tube was further performed, followed by a continuous suture of the anterior wall. Results The procedure was successfully accomplished in all patients whithout conversion to open surgery. The operating time was 90-240 minutes with the median time of 160 minutes. The estimated blood loss was 20-70 mL with the median of 50 mL. No severe surgical complication occurred in perioperative period. The 3-24 -month follow up showed that symptoms of lumbar pain were relieved or disappeared in all the incorporated patients. Postoperative radiographic examination showed no stomal stenosis at the ureteropelvic junction, and the hydronephrosis was alleviated. Conclusions Retroperitoneal laparoscopic dismembered pyeloplasty for UPJO is an effective, safe, and minimally invasive surgical technique. The key to the success of the operation is to the accurate renal pelvis clipping, tension- and torsion-free anastomosis of the lowest position of the renal pelvis and the ureter, and the reconstruction of a new funnel-shaped ureteropelvic junction.

    Release date:2017-06-22 02:01 Export PDF Favorites Scan
  • TiRobot-assisted percutaneous sacroiliac cannulated screw fixation for posterior pelvic ring injury with sacral variations

    ObjectiveTo investigate the effectiveness of TiRobot-assisted percutaneous sacroiliac cannulated screw fixation in the treatment of posterior pelvic ring injuries with sacral variations, and to evaluate its feasibility and safety. Methods The clinical data of 7 patients with Tile type C pelvic fractures and sacral variations treated with TiRobot-assisted percutaneous sacroiliac cannulated screw fixation between January 2020 and June 2021 were retrospectively analyzed. There were 5 males and 2 females with an average age of 36 years (range, 17-56 years). The causes of injury were traffic accident in 4 cases and falling from height in 3 cases. According to Tile classification of pelvic fractures, there were 1 case of type C1.1, 1 case of type C1.2, and 5 cases of type C1.3; according to Denis classification of sacral fractures, there were 3 cases of zone Ⅰ and 4 cases of zone Ⅱ; sacral deformities included 3 cases of lumbar sacralization, 2 cases of sacral lumbarization, and 2 cases of accessory auricular surface of the sacrum. The time from injury to operation ranged from 2 to 7 days, with an average of 4.6 days. The implantation time of each screw, the fluoroscopy times of each guide pin, the quality of fracture reduction (according to Matta score), the excellent and good rate of screw position, the healing time of fracture, and the incidence of complications were recorded, and the effectiveness was evaluated by Majeed score. Results A total of 13 screws were implanted during the operation, the implantation time of each screw was 10-23 minutes, with an average of 18.2 minutes; the position of the guide pin was good, and no guide pin was adjusted, the fluoroscopy times of each guide pin were 3-7 times, with a median of 4 times. Postoperative imaging data at 3 days showed that the position of sacroiliac screw implantation was evaluated as excellent. No complication such as incision infection or vascular nerve injury occurred, and no adverse events related to robotic devices occurred. At 3 days after operation, according to Matta score, the quality of fracture reduction was excellent in 6 cases and good in 1 case, and the excellent and good rate was 100%. All the 7 patients were followed up 6-15 months, with an average of 12.4 months. Bone union was achieved in all patients, and the healing time ranged from 18 to 24 weeks, with an average of 21.2 weeks. Majeed score at last follow-up was 81-95, with an average of 91.5; 5 cases were excellent, 2 cases were good, and the excellent and good rate was 100%. ConclusionTiRobot-assisted percutaneous sacroiliac cannulated screw fixation for posterior pelvic ring injury with sacral variation is accurate, safe, minimally invasive, and intelligent, and the effectiveness is satisfactory.

    Release date:2022-08-29 02:38 Export PDF Favorites Scan
7 pages Previous 1 2 3 ... 7 Next

Format

Content