west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "plateau" 48 results
  • Treatment of posterolateral tibial plateau fractures with a novel lateral tibial plateau annular plate via fibular neck osteotomy approach

    Objective To investigate the effectiveness of a novel lateral tibial plateau annular plate (hereinafter referred to as the novel plate) fixation via fibular neck osteotomy approach for posterolateral tibial plateau fractures. Methods Between January 2015 and December 2018, 22 patients with posterolateral tibial plateau fractures were treated. There were 10 males and 12 females with an average age of 39.0 years (range, 25-56 years). Seven fractures were caused by falls, 10 by traffic accidents, and 5 by falling from height. The time from injury to hospitalization ranged from 3 to 12 days, with an average of 7.0 days. All patients were closed fractures. According to Schatzker classification, the fractures were classified as type Ⅱ in 8 cases, type Ⅲ in 9 cases, type Ⅴ in 1 case, and type Ⅵ in 4 cases. The fractures were fixed with the novel plates after reduction via fibular neck osteotomy approach. The fracture reduction and healing were observed by X-ray film after operation. The range of motion of the knee joint was recorded and the function was evaluated by modified American Hospital for Special Surgery (HSS) score. Results All operations were completed successfully. The operation time was 60-95 minutes (mean, 77.6 minutes). The intraoperative blood loss was 100-520 mL (mean, 214.5 mL). There was 1 case of common peroneal nerve injury during operation and 2 cases of fat liquefaction of incision after operation. All patients were followed up 13-32 months (mean, 19.4 months). Postoperative X-ray films showed that the fracture reduction was good in 17 cases and moderate in 5 cases, and all fractures healed with a healing time of 10-18 weeks (mean, 13.0 weeks). At last follow-up, the range of motion of the knee joint ranged from 100° to 145° in flexion (mean, 125.5°) and from 0° to 4° in extension (mean, 1.2°). The modified HSS score was 82-95 (mean, 86.3). There was no complications such as plate deformation, screw fracture, fracture reduction loss, skin necrosis, and so on. Conclusion For posterolateral tibial plateau fractures, the novel plate fixation via fibular neck osteotomy approach has the advantages of clear intraoperative field, firm fracture fixation, and less postoperative complications, which is beneficial to the recovery of knee joint function.

    Release date:2022-09-30 09:59 Export PDF Favorites Scan
  • ARTHROSCOPIC PERCUTANEOUS OSTEOSYNTHESIS OF LOW-ENERGY TIBIAL PLATEAU FRACTURES

    Objective To explore the treatment of low-energy tibial plateau fractures with arthroscopic percutaneous osteosynthesis. Methods From May 2004 to April 2008, 27 cases of tibial plateau fractures were treated with arthroscopic management. There were 19 males and 8 females, aged 18-61 years old (mean 41.5 years old). Fracture was caused by trafficaccident in 18 cases, by fall ing from height in 6 cases, by bruise in 2 cases, and by other in 1 case. There were 8 cases of type I, 12 cases of type II, 2 cases of type III and 5 cases of type IV according to Schatzker classification. The time from injury to operation was 3-15 days (mean 5.2 days). After symptomatic managements were performed arthroscopically in 11 cases of meniscus tear, 4 cases of medial collateral l igament rupture of knee joint, 3 cases of anterior cruciate l igament rupture of knee joint and 2 cases of cartilage fracture resulting in joint bodies, fracture was reduced and fixed with 2 or 4 cannulated screws (7 mm in diameter). Autograft of il ium was given 6 cases of bone defect. Early functional exercise was done. Results The operation time was 55-150 minutes (mean 93 minutes); the hospital ization days were 7-22 days (mean 16 days). All incision healed primarily. Edema of the affected leg occurred in all patients and subsided after 3 days of symptomatic management. In one patient who did not cooperate in functional exercise, adhesion occurred and normal function was recovered after by manual dissolution under conditions of anesthesia after 3 months of operation. All patients were followed up 6-36 months (mean 16.6 months). The range of motion of knee joint was 105-140° (mean 121°). According to Lysholm scale of knee joint, the score was 72-100 points (mean 93.6 points) 6 months after operation. The X-ray film showed no signs of osteoarthritis. Conclusion Arthroscopic percutaneous osteosynthesis yields satisfactory results and can be accepted as an alternative and effective method for the treatment of low-energy tibial plateau fractures.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
  • Clinical study on the subchondral screw compression technique assisted reduction of residual or secondary collapse of lateral tibial plateau

    Objective To explore the reduction and support effect of the subchondral screw compression technique for residual or secondary collapse of the lateral tibial plateau during operation. Methods Between January 2020 and June 2021, 11 patients with residual or secondary collapse of the lateral tibial plateau during operation were treated with the subchondral screw compression technique. There were 6 males and 5 females, aged 52.3 years old (range, 27-64 years). The fractures were caused by traffic accident in 10 cases and falling from height in 1 case and located at the left knee in 6 cases and the right knee in 5 cases. According to Schatzker classification, there were 5 cases of type Ⅱ fractures, 4 cases of type Ⅲ fractures, and 2 cases of type Ⅴfractures. According to the three columns classification, there were 5 cases of lateral column, 4 cases of lateral column and posterior column, and 2 cases of three columns. The time from injury to operation was 4.5 days (range, 3-7 days). During the follow-up, X-ray films were obtained and the Rasmussen standard was used to evaluate the quality of fracture reduction, meanwhile fracture healing was observed. The medial proximal tibial angle (mPTA), posterior tibial slope angle (pTSA), and articular surface collapse were measured at immediate and 12 months after operation. The knee joint range of motion was evaluated at last follow-up, and the knee joint function was evaluated using the Hospital for Special Surgery (HSS) score. Results All operations were successfully completed, with a mean operation time of 71.4 minutes (range, 55-120 minutes), and a mean hospital stay of 8.0 days (range, 5-13 days). The incisions all healed by first intention, without complications such as infection, flap necrosis, or vascular and nerve injury. All patients were followed up 16.5 months on average (range, 12-24 months). X-ray films showed that the fracture reduction score was 14-18 (mean, 16.7) according to Rasmussen score criteria; and 5 cases were rated as excellent and 6 as good. All fractures healed clinically with a mean clinical healing time of 14.9 weeks (range, 12-16 weeks), and there was no complications such as plate or screw loosening. At 12 months after operation, the mPTA and pTSA were (87.5±1.7)° and (6.2±3.1)°, respectively; there was no significant difference when compared to the values at immediate after operation [(87.6±1.8)° and (6.5±3.1)°] (P>0.05). The articular surface of the tibial plateaus was effectively supported, and it collapsed again by 0-1.0 mm at 12 months, with an average of 0.4 mm. At last follow-up, the knee joint range of motion was 115°-135° (mean, 126.8°) and the HSS score for knee joint function was 87-98 (mean, 93.9). Five patients underwent secondary operation to remove the internal fixator at 12-18 months after operation.ConclusionThe subchondral screw compression technique is helpful for the reduction of residual or secondary collapse of the lateral tibial plateau during operation, and can provide good support for osteochondral blocks.

    Release date:2023-12-12 05:09 Export PDF Favorites Scan
  • Application of a new universal locking anatomical plate in treatment of tibial plateau posterolateral column fractures

    Objective To investigate the effectiveness of a new tibial plateau posterolateral column universal locking anatomical plate (hereinafter referred to as “new universal locking anatomical plate”) in the treatment of tibial plateau posterolateral column fractures. Methods Between October 2020 and December 2021, 14 patients with tibial plateau posterolateral column fracture were treated with a new universal locking anatomical plate. There were 7 males and 7 females with an average age of 59 years ranging from 29 to 75 years. There were 5 cases on the left side and 9 cases on the right side. The causes of injury included falling from height in 5 cases, traffic accident in 7 cases, and other injuries in 2 cases. The time from injury to operation ranged from 3 to 10 days, with an average of 6 days. According to Schatzker classification, there were 4 cases of type Ⅱ, 8 cases of type Ⅴ, and 2 cases of type Ⅵ. All fractures involved the posterolateral tibial plateau. Three column classification: two columns (anterolateral column+posterior column) in 4 cases, three columns in 10 cases. The operation time, intraoperative blood loss, fracture healing, and complications were recorded. The reduction of tibial plateau fracture was evaluated by Rasmussen radiographic score, and the recovery of knee function was evaluated by Hospital for Special Surgery (HSS) score. Results All 14 cases completed the operation successfully. The operation time was 95-180 minutes, with an average of 154 minutes, and the intraoperative blood loss was 100-480 mL, with an average of 260 mL. All patients were followed up 6-19 months, with an average of 12.5 months. All fractures healed, and the healing time was 15-24 weeks, with an average of 18.7 weeks. During the follow-up, there was 1 case of common peroneal nerve palsy and 1 case of traumatic osteoarthritis. There was no other complication such as vascular injury, incision infection, deep venous thrombosis of lower limbs, heterotopic ossification, bone nonunion, and failure of internal fixation. The reduction of tibial plateau fractures was good immediately after operation, and the Rasmussen radiological score was 10-18, with an average of 15.7; 3 cases were excellent, 10 cases were good, and 1 case was fair, with an excellent and good rate of 92.9%. The scores and grades of HSS at 3 months after operation and at last follow-up significantly improved when compared with those before operation (P<0.05). There was no significant difference between 3 months after operation and last follow-up (P>0.05).Conclusion For the fractures involving the posterolateral column of the tibial plateau, the new universal locking anatomical plate can provide strong fixation, satisfactory postoperative fracture reduction, and good recovery of knee function.

    Release date:2022-12-19 09:37 Export PDF Favorites Scan
  • TREATMENT OF SCHATZKER V/VI TIBIAL PLATEAU FRACTURE INVOLVED POSTEROMEDIAL CONDYLE THROUGH COMBINED APPROACH

    Objective To observe the cl inical results of treatment of Schatzker V/VI tibial plateau fracture involved posteromedial condyle through combined posteromedial and anterolateral approach and fixed with two or three plates. Methods From April 2005 to April 2008, 18 cases of tibial plateau fracture involved posteromedial condyle were treated, including 14 males and 4 females with an average age of 38.5 years old (range, 18-62 years old). According to Schatzker classification, there were 12 cases of type V and 6 cases of type VI. The posteromedial condyle were involved in 13 cases and bilateral posterior condyle in 5 cases. All patients were given posteromedial fragment and medial condyle fracture reduction through posteromedial approach firstly, and then lateral condyle fracture reduction through anterolateral approach, and injury of meniscuses and cruciate l igaments were treated at the same time. Three plates (lateral, medial, posterior) were used in 10 cases and two plates (lateral, posteromedial) in 8 cases. Results All wounds achieved heal ing by first intention without compl ications such as infection, flap necrosis, osteofascial compartment syndrome, chronic osteomyel itis, nonunion. All patients were followed up for 12 to 48 months with an average of 24.4 months. The mean flexion of the knee was 118.4° (range, 100-130°) 1 year after operation. According to Iowa evaluation system, 12 patients got excellent results, 4 good, and 2 fair; the excellent and good rate was 88.9%. Conclusion Combined posteromedial and anterolateral approach and fixed with two or three plates is effective in treatment of the Schatzker V/VI tibial plateau fracture involved posteromedial condyle. Anatomical reduction and rigid internal fixation of the posteromedial fragment are critical to successful operation.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
  • Osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in treatment of tibial plateau fractures involving posterolateral column collapse

    Objective To investigate the effectiveness of osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in the treatment of tibial plateau fractures involving posterolateral column collapse. Methods A clinical data of 23 patients with tibial plateau fractures involving posterolateral column collapse, who had undergone osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation between January 2015 and June 2021, was retrospectively analyzed. There were 14 males and 9 females with an average age of 42.6 years ranging from 26 to 62 years. The causes of injury included traffic accident in 16 cases, falling from height in 5 cases, and other injuries in 2 cases. According to Schatzker classification, there were 15 cases of type Ⅴ and 8 cases of type Ⅵ. The time from injury to operation was 4-8 days with an average of 5.9 days. The operation time, intraoperative blood loss, fracture healing time, and complications were recorded. The depth of articular surface collapse of posterolateral column and posterior inclination angle (PSA) of the tibial plateau were compared before operation and at 2 days and 6 months after operation; fracture reduction of tibial plateau fracture was evaluated by Rasmussen anatomic score. The recovery of knee function was evaluated by Hospital for Special Surgery (HSS) score at 2 days and 6 months after operation. Results All 23 patients were completed the operation successfully. The operation time was 120-195 minutes, with an average of 152.8 minutes; the intraoperative blood loss was 50-175 mL, with an average of 109.5 mL. All patients were followed up 12-24 months, with an average of 16.7 months. One patient had superficial wound infection after operation, and the incision healed after dressing change; primary healing of incision of other patients was obtained. The fracture healing time was 12-18 weeks, with an average of 13.7 weeks. No failure of internal fixation, varus and valgus deformity of the knee joint, and instability of the knee joint was found at last follow-up. One patient developed joint stiffness and the range of motion of the knee joint was 10°-100°; the range of motion of the knee joint of other patients was 0°-125°. At 2 days and 6 months after operation, the depth of articular surface collapse of posterolateral column, PSA, and Rasmussen anatomic scores significantly improved when compared with those before operation (P<0.05). There was no significant difference between the two postoperative time points (P>0.05). The HSS score at 6 months after operation was significantly higher than that at 2 days after operation (P<0.05). Conclusion For tibial plateau fractures involving posterolateral column collapse, reduction and internal fixation through osteotomy of non-core weight-bearing area of the lateral tibial plateau has the advantages of fully expose the posterolateral column fragment, good articular surface reduction, sufficient bone grafting, and fewer postoperative complications. It is beneficial to restore knee joint function and can be widely used in clinic.

    Release date:2023-04-11 09:43 Export PDF Favorites Scan
  • Correlation study on the influencing factors of semitendinosus insertion location

    Objective To investigate the relationship between the vertical distance from semitendinosus insertion to tibial plateau (S-T) and the physical characteristics of patients, in order to provide reference for incision design to expose the semitendinosus insertion. Methods The patients with ligament injury who underwent primary anterior cruciate ligament reconstruction between January 2022 and December 2022 were selected as the research subjects. The patients’ baseline data were collected, including age, gender, height, and body mass. During reconstruction operation, the S-T was measured. Considering the S-T as the dependent variable and baseline data as the independent variable, multiple linear regression analysis was used to establish a regression equation to determine the possible influencing factors of semitendinosus insertion location. Results According to the selection standard, a total of 214 patients were enrolled, including 156 males and 58 females, aged (27±9) years (14-49 years), with a height of (174.7±6.8) cm (range, 160-196 cm) and a body mass of (73.43±12.35) kg (range, 53-105 kg). The S-T was (56.36±3.61) mm (range, 47-67 mm). The multiple linear regression analysis results showed that the height was positively correlated with S-T (β=0.407, SE=0.055, t=7.543, P<0.001); the regression equation was S-T=−14.701+0.407×height, R2=0.690. ConclusionThere was a linear relationship between the height and semitendinosus insertion. The location of semitendinosus insertion estimated by the formula (S-T=−14.701+0.407×height) is reasonable, which provides a theoretical basis for rapid, accurate, and safe location of semitendinosus insertion and design of surgical incision in clinic.

    Release date:2023-08-09 01:37 Export PDF Favorites Scan
  • Application of reverse traction device in preoperative treatment of high-energy tibial plateau fracture

    Objective To investigate the effectiveness of the reverse traction device in the preoperative treatment of high-energy tibial plateau fractures. Methods A retrospective study was conducted to analyze the clinical data of 33 patients with high-energy tibial plateau fractures who met the selection criteria between December 2020 and December 2023. All patients were treated by open reduction and internal fixation. According to the preoperative traction method, they were divided into the observation group (16 cases, treated with a reverse traction device on the day of admission) and the control group (17 cases, treated with heel traction on the day of admission). There was no significant difference in baseline data such as gender, age, body mass index, affected side, cause of injury, fracture Schatzker classification between the two groups (P>0.05). Preoperative waiting time, preoperative related complications (nail channel loosening, nail channel oozing, nail channel infection, soft tissue necrosis, soft tissue infection, deep vein thrombosis of the lower extremity, etc.), operation time, and total hospitalization time were recorded and compared between the two groups. On the 4th day after traction, visual analogue scale (VAS) score was used to evaluate the pain relief of the patients, the swelling value of the affected limb was measured, and the Immobilization Comfort Questionnaire (ICQ) score was used to evaluate the perioperative hospital comfort of the patients. Results Both groups of patients completed the operation successfully, and the operation time, total hospitalization time, and preoperative waiting time of the observation group were significantly less than those of the control group (P<0.05). There was no preoperative related complications in the observation group; in the control group, 3 patients had nail channel loosening and oozing, and 2 cases had the deep vein thrombosis of the lower extremity; the difference in the incidence of complication between the two groups was significant (P<0.05). On the 4th day after traction, the ICQ score, VAS score, and limb swelling value of the observation group were significantly better than those of the control group (P<0.05). X-ray films showed that the tibial plateau fracture separation and lower limb alignment recovered after calcaneal traction in the control group, but not as obvious as in the observation group. The fracture gap in the observation group significantly reduced, the tibial plateau alignment was good, and the lateral angulation deformity was corrected. Conclusion The use of reverse traction treatment in patients with high-energy tibial plateau fractures on admission can accelerate the swelling around the soft tissues to subside, reduce patients’ pain, shorten the preoperative waiting time, improve the patients’ preoperative quality of life, and contribute to the shortening of the operation time, with a good effectiveness.

    Release date:2024-07-12 11:13 Export PDF Favorites Scan
  • EFFECTIVENESS OF OPEN REDUCTION AND INTERNAL FIXATION WITHOUT OPENING JOINT CAPSULE ON TIBIAL PLATEAU FRACTURE

    ObjectiveTo introduce the surgery method to reset and fix tibial plateau fracture without opening joint capsule, and evaluate the safety and effectiveness of this method. MethodsBetween July 2011 and July 2013, 51 patients with tibial plateau fracture accorded with the inclusion criteria were included. All of 51 patients, 17 cases underwent open reduction and internal fixation without opening joint capsule in trial group, and 34 cases underwent traditional surgery method in control group. There was no significant difference in gender, age, cause of injury, time from injury to admission, side of injury, and types of fracture between 2 groups (P>0.05). The operation time, intraoperative blood loss, incision length, incision heal ing, and fracture healing were compared between 2 groups. The tibial-femoral angle and collapse of joint surface were measured on X-ray film. At last follow-up, joint function was evaluated with Hospital for Special Surgery (HSS) knee function scale. ResultsThe intraoperative blood loss in trial group was significantly less than that in control group (P<0.05). The incision length in trial group was significantly shorter than that in control group (P<0.05). Difference was not significant in operation time and the rate of incision heal ing between 2 groups (P>0.05). The patients were followed up 12-30 months (mean, 20.4 months) in trial group and 12-31 months (mean, 18.2 months) in control group. X-ray films indicated that all cases in 2 groups obtained fracture heal ing; there was no significant difference in the fracture healing time between 2 groups (t=1.382, P=0.173). On X-ray films, difference was not significant in tibial-femoral angle and collapse of joint surface between 2 groups (P>0.05). HSS score of the knee in trial group was significantly higher than that of control group (t=3.161, P=0.003). ConclusionIt can reduce the intraoperative blood loss and shorten the incision length to use open reduction and internal fixation without opening joint capsule for tibial plateau fracture. Traction of joint capsule is helpful in the reduction and good recovery of joint surface collapse. In addition, the surgery without opening joint capsule can avoid joint stiffness and obtain better joint function.

    Release date: Export PDF Favorites Scan
  • CLINICAL STUDY ON TREATMENT OF POSTEROLATERAL FRACTURE OF TIBIAL PLATEAU VIA SUPERIOR FIBULAR HEAD APPROACH

    Objective To observe the effectiveness of the superior fibular head approach for the treatment of posterolateral fracture of the tibial plateau. Methods Between June 2010 and February 2012, 20 cases of posterolateral fracture of the tibial plateau were treated through superior fibular head approach, including 1 case of simple posterolateral fracture of the tibial plateau and 19 cases of posterolateral fracture of the tibial plateau with other fractures. There were 12 males and 8 females with an average age of 42.2 years (range, 28-58 years). All patients had closed fractures. Fracture was caused by traffic accident in 14 cases, by falling from height in 4 cases, and by twist injury in 2 cases. Associated injuries included lateral meniscus injury in 5 cases, medial meniscus injury in 2 cases, and anterior cruciate ligament injury in 1 case. The time from injury to admission ranged from 90 minutes to 32 hours (mean, 4.5 hours), and the time from admission to operation was 5-12 days (mean, 7.8 days). All cases underwent fracture reduction and fixation with Pilon plates through the superior fibular head approach, and associated fracture and meniscal injury were treated. Results All incisions healed by first intention, and no numbness or articular instability occurred. All patients were followed up 6-26 months (mean, 19.1 months). The average fracture healing time was 10.2 weeks (range, 8-12 weeks). During following-up, no related complication of fixation loosening or articular surface loss occurred. According to Rasmussen knee score criteria at last follow-up, the score was 18-30 (mean, 27.9); 16 cases were graded as excellent, 3 cases as good, and 1 case as fair, with an excellent and good rate of 95%. Conclusion The superior fibular head approach for the treatment of posterolateral fracture of the tibial plateau is simple, safe, and effective, and can achieve a good surgical outcome.

    Release date:2016-08-31 04:06 Export PDF Favorites Scan
5 pages Previous 1 2 3 4 5 Next

Format

Content