A new urine analysis core module based on high performance 32-bit microprocessor and high precision color sensor was presented. A novel optical structure and a specific circuit were applied to improve measurement precision and temperature was used to compensate for results in this core module. The information of urine test peice, such as all original data and color RGB value, reflectivity, semi-quantitative level, etc. can be output. The results showed that the measuring precision was about 95% or above with ideal stability and reliability using this presented core module, which can be conveniently applied in various urine analyzers, and can greatly decrease the cost of urine analyzers in development and production.
Non-drug treatment of hypertension has become a research hotspot, which might overcome the heavy economic burden and side effects of drug treatment for the patients. Because of the good treatment effect and convenient operation, a new treatment based on slow breathing training is increasingly becoming a kind of physical therapy for hypertension. This paper explains the principle of hypertension treatment based on slow breathing training method, and introduces the overall structure of the portable blood pressure controlling instrument, including breathing detection circuit, the core control module, audio module, memory module and man-machine interaction module. We give a brief introduction to the instrument and the software in this paper. The prototype testing results showed that the treatment had a significant effect on controlling the blood pressure.
OBJECTIVE: To investigate the characteristics and the pathologic classification of electrical-injury nerve using somatosensory evoked potential(SEP) technique. METHODS: SEP were detected and evaluated in 12 cases with electrical-injury nerve during operation, electrical stimulation was commenced from distal side of nerve where the structure of nerve looks normal under operating microscope, up to proximal side until evoking out a stable SEP predeterminate virtual value. Pathological examination and the following functional evaluation were compared with the values of SEP. RESULTS: At the site of nerve looking normal under operating microscope, perineurium appears normal or slightly thicken. But there are obvious fibrosis and fibrotic proliferation between fascicular and intrafascicular. Vessel plexus is not seen. At SEP stabilizely evoked site, nervous construction is normal, there are visible interfascicular vessel plexus and connective tissue appears loose. Comparing SEP values with pathological section, amplitude and latency of SEP is positively correlative with the quality of nerve. Eight cases repaired with SEP technique to select the anastomosis site for nerve transplantation were followed up, two-point discrimination reached grade III (America hand surgery association criterion) within 62.5% cases. CONCLUSION: SEP technique is valuable method for functional evaluation of electrical- injury nerve which has a complicated pathology. The pathology of electrical-injury nerve can be classified into 4 types, type A: fibrosis of nerve; type B: nerve looking normal under operation microscope, perineurium appears thicken, and there are obvious fibrosis and fibrotic proliferation between fascicular and intrafascicular, vessel plexus is rarely to see; type C: nerve looks normal, lymphocyte infiltration exists and it is obvious that there are many physalis-like, retrogressive construction in the section; type D: nervous construction is normal, there are visible interfascicular vessel plexus, and connective tissue appears loose, SEP always can be stably evoked.
ObjectiveTo investigate the effectiveness of using a sensory prefabricated flap to repair the heel avulsion injury. MethodsBetween August 2012 and August 2013, 6 cases of heel avulsion injury were treated. There were 4 males and 2 females, aged 16-54 years (mean, 29 years). The causes were crush injury in 4 cases and wheel twist injury in 2 cases. The injury to admission time was 2-6 hours (mean, 4 hours). The size of skin avulsion ranged from 5 cm×3 cm to 15 cm×8 cm. Avulsion skin had no replanted condition. At one stage operation, the avulsed heel skin soft tissue was made the full thickness skin graft which was fostered on the anterolateral thigh with lateral circumflex femoral artery perforator, and the lateral femoral cutaneous nerve was put beneath the skin to prefabricate the prefabricated flap; at two stage operation, the prefabricated skin flap pedicled with lateral circumflex femoral artery was used to repair the wound, and the lateral femoral nerve was anastomosed with the calcaneal nerve to reconstruct the feeling. ResultsSix prefabricated flaps all survived, and re-plantation flaps survived after operation. The wounds healed by first intention at donor site and recipient site. The patients were followed up 1-2 years (mean, 1.5 years). The flaps had satisfactory appearance and soft texture. At 1 year after operation, the sensation of the flaps was S3, with two-point discrimination of 22-27 mm (mean, 24.3 mm). According to ZHANG Ming's evaluation standards, the results were excellent in 5 cases, and good in 1 case. The patients could walk normally or with weight-bearing; only linear scar formed at the donor site. ConclusionFor patients with heel soft tissue avulsion injury without replantation qualification, a sensory prefabricated flap by the avulsed heel skin soft tissue can transplanted to repair the heel defect. Satisfactory effectiveness can be obtained in heel appearance and function recovery.
Objectives To investigate the correlation between blood total cholesterol (TC) and prognosis of idiopathic sudden sensorineural hearing loss (ISSNHL) and to provide references for clinical treatment and prognosis assessment. Methods We included 232 ISSNHL patients with total deafness in Wenzhou Central Hospital from June 2015 to March 2017 using a prospective cohort design. Recording information including age, gender, hypertension, diabetes mellitus, vertigo, level of blood total cholesterol (TC), level of triglyceride (TG), level of low-density lipoprotein (LDL-C) and LDL/HDL ratio (LDL-C/HDL-C) were collected. Correlation between the prognosis of ISSNHL and blood total cholesterol were analyzed by univariable and multivariable logistic regression analysis. Results The clinical effective rate of patients with TC ranging from 5.2 mmol/L to 6.2 mmol/L was higher than that of patients with TC lower than 5.2 mmol/L (univariable: RR=6.49, 95%CI 3.16 to 13.30, P<0.001; multivariable-adjusted covariates: RR=6.15, 95%CI 2.66 to 14.3,P<0.001) with significant difference. No significant difference was found between patients with TC lower than 5.2 mmol/L and patients with TC higher than 6.2 mmol/L (univariable: RR=1.02, 95%CI 0.52 to 2.00,P=0.960; multivariable-adjusted covariates: RR=1.61, 95%CI 0.55 to 4.73, P=0.386). Gender-specific analysis showed for both male and female groups, the effective rates of patients with TC ranging from 5.2 mmol/L to 6.2 mmol/L were significantly higher than those of patients with TC lower than 5.2 mmol/L. There was no significant difference between patients with TC lower than 5.2 mmol/L and patients with TC higher than 6.2 mmol/L (P>0.05) in either male group or female group. Conclusion The current study suggests that patients with levels of TC ranging from 5.2 mmol/L to 6.2 mmol/L predicts the best prognosis.
Objective To investigate the relationship between graded spinal cord ischemia/reperfusion injury and somatosensory evoked potentials(SEP),neurologic function score(NFS)and the histopathological changes of spinal cord. Methods Forty rabbits were randomized and equally divided into 4 groups: shamoperation group, ischemia for 30min, 45min and 60min groups. The spinal cord ischemiareperfusion injury model was created by occlusion of the abdominal aorta in rabbits. SEP was monitored before ischemia,5,10minutes after ischemia, 15, 30 minutes, 1,2, 24 and 48 hours after reperfusion. NFS was evaluated at 6,12,24 and 48 hours after reperfusion.The pathological changes of spinal cord were observed after reperfusion 48 hours. Results The pathological characters with mild,moderate and severe spinal cord ischemia/reperfusion injury could be simulated by declamping after 30, 45 and 60 minutes infrarenal aorta crossclamping. SEP amplitude returned to normal after reperfusion 15 minutes(Pgt;0.05)and SEP latency returned to normal after reperfusion 30 minutes(Pgt;0.05)during mild spinal cord ischemia/reperfusion injury.SEP amplitude returned to normal after reperfusion 30 minutes(Pgt;0.05)and SEP latency returned to normal after reperfusion 60 minutes(Pgt;0.05)during moderate spinal cord ischemia/reperfusion injury. SEP latency increased and SEP amplitude decreased during severe spinal cord ischemia/reperfusion injury,compared with other groups, there were significant differences in SEP latency and SEP amplitude by clamping the infrarenal aorta for 60min(Plt;0.01). With graded spinal cord ischemia/reperfusion injury, compared with shamoperation group, spinal cord ischemiareperfusion groups had significant differences in NFS(Plt;0.01). Conclusion SEP is much quicker in the recovery of amplitude than latency during spinal cord ischemia/reperfusion. SEP is a sensitive and accurate index for spinal cord function during ischemia/reperfusion injury. SEP monitoring spinal cord ischemia/reperfusion injury during operation provides experimental basis for clinical application.
Objective To assess the effects and safety of vasodilators for sudden sensorineurial hearing loss (SSHL). Search strategy Electronic databases: MEDLINE from 1966, EMBASE from 1974, the Cochrane Controlled Trials Register, Chinese Bio-medicine Database from 1989. Hand search: Five kinds of Chinese otolaryngology journals were searched. Literature references were checked intensively. Selection criteria Randomized controlled trials comparing vasodilators with placebo or other drugs in patients with SSHL. Data collection and analysis At least two reviewers independently assessed trials quality and extracted data. Main results Thirteen trials with 1 155 patients were eligible and included in the systematic review. Ten of the trials were from developed countries and them were from P. R. China. None of the four trials showed that the effects of vasodilators were better than placebo for SSHL. None of the seven trials showed that the effects of one kind of vasodilators were better than that of the other vasodilators. Two trials showed that other drugs, such as batroxobin and hypaque,were probably better than some vasodilators (dextran, papaverine, 654-2, danshen). Eight trials reported the side effects of vasodilators, such as pruritus, allergy, etc. Reviewers’ conclusions Base on the systematic review of current eligible randomized controlled trials, there is no evidence to prove that vasodilator therapy is better than placebo or other therapies for SSHL, or the effects of one kind of vasodilator are better than that of the other vasodilators. We can’t draw a reliable conclusion about the effects of vasodilators for SSHL at the moment. And we must pay attention to their potential adverse reactions.
Objective To explore a novel method for early lung cancer screening based on exhaled breath analysis. MethodsThis study enrolled patients with suspected pulmonary malignancies and healthy individuals undergoing physical examinations at Sir Run Run Shaw Hospital, Zhejiang University School of Medicine (Qingchun and Qiantang campuses) from September 2023 to June 2024. Enrolled subjects were categorized into a lung cancer group, a benign nodule/tumor group, and a healthy control group. Exhaled breath samples were collected using a sensor array constructed from multiple graphene composite materials to capture breath fingerprints. Based on the collected data, screening and diagnostic models for lung cancer were developed and their performance was evaluated. ResultsA total of 4 580 subjects were included. Among them, 3 195 were pathologically diagnosed with pulmonary malignancies, including 1 394 males and 1 801 females with a mean age of (58.93±12.37) years, 599 were diagnosed with benign nodules/tumors including 339 males and 260 females with a mean age of (57.10±11.06) years, and 786 were healthy controls with no pulmonary nodules detected on chest CT including 420 males and 366 females with a mean age of (29.75±9.32) years. The screening model for high-risk populations (distinguishing patients with lung cancer/high-risk pulmonary nodules from healthy individuals) demonstrated excellent performance, with an area under the receiver operating characteristic curve (AUC) of 0.926. At the optimal Youden’s index (cutoff threshold of 63.5%), the external test set achieved a specificity of 85.2%, a sensitivity of 88.4%, and an accuracy of 86.8%. The diagnostic model (distinguishing patients with lung cancer/premalignant lesions from those with benign pulmonary nodules/healthy individuals) achieved an AUC of 0.818. At its optimal Youden’s index (cutoff threshold of 47.0%), the external test set showed a specificity of 71.7%, a sensitivity of 77.3%, and an accuracy of 74.5%. ConclusionThe non-invasive breath analysis platform based on a sensor array, developed in this study, can achieve rapid and relatively accurate lung cancer screening by analyzing breath fingerprints. This confirms the feasibility of this technology for early lung cancer screening and holds promise for facilitating the early detection and intervention of lung cancer.
The transforming growth factor-β1 (TGF-β1)/Smad3 signal pathway is related to mutiple physiological and pathological generation mechanism of human being. Up to date, however, the spacial and time information on the phosphorylated Smad3 is still unclear. In this study, the process of Smad3 phosphorylation was observed under the physiological state in the living cells. Firstly, the ECFP-Smad3-Citrine (Smad3 biosensor) fusion protein expression vector was constructed and identified. Then the Smad3 biosensor was transfected into 293T cells. The transfection efficiency and the expressions of fusion proteins were observed in 24 hours. Thirdly, Smad3 biosensor flurorescence resonance energy transfer (FRET) was observed with the inversion fluorescence microscope and measured by the MetaFlour FRET 4.6 software. Smad3 biosensor transfection efficiency was nearly 40% and the fusion protein was seen under the fluorescence microscope. The FRET ratio of Smad3 biosensor in living 293T cells was decreased after 10 minutes incubation with the ligand of TGF-β1. The period of decreasing CFP and enhancing Citrine signals was about 300 seconds. With the technology of FRET, the TGF-β1/Smad3 signal pathway could be real time monitored dynamically under the physiological condition in living cells.
Artificial prosthesis is an important tool to help amputees to gain or partially obtain abled human limb functions. Compared with traditional prosthesis which is only for decoration or merely has feedforward control channel, the perception and feedback function of prosthesis is an important guarantee for its normal use and self-safety. And this includes the information of position, force, texture, roughness, temperature and so on. This paper mainly summarizes the development and current status of artificial prostheses in the field of perception and feedback technology in recent years, which is derived from two aspects: the recognition way of perception signals and the feedback way of perception signals. Among the part of recognition way of perception signals, the current commonly adopted sensors related to perception information acquisition and their application status in prosthesis are overviewed. Additionally, from the aspects of force feedback stimulation, invasive/non-invasive electrical stimulation, and vibration stimulation, the feedback methods of perception signals are summarized and analyzed. Finally, some problems existing in the perception and feedback technology of artificial prosthesis are proposed, and their development trends are also prospected.