Biological valves can lead to structural valve degeneration (SVD) over time and due to various factors, reducing their durability. SVD patients need to undergo valve replacement surgery again, while traditional open chest surgery can cause significant trauma and patients often give up treatment due to intolerance. Research has shown that as an alternative treatment option for reoperation of thoracic valve replacement surgery, redo-transcatheter aortic valve replacement for SVD is safe and effective, but still faces many challenges, including prosthesis-patient mismatch, high cross valve pressure difference, and coronary obstruction. This article aims to review the strategies, clinical research status and progress of redo-transcatheter aortic valve replacement in SVD patients.
Objective To compare the efficacy of 6-epsilon-aminocaproic acid (EACA) with aprotinin on reducing postoperative bleeding in cardiac valve replacement procedures, and to investigate its influence on the possible thromboembolism and the renal function. Methods Seventy-nine patients who underwent cardiac valve replacement were randomly divided into two groups: EACA group (n = 39) and aprotinin group (n = 40), which were given EACA and aprotinin separately in operations. The volumes of drainage to body surface area (BSA), blood transfusion were recorded during 24 h after operations. The concentrations of serum D-dimer and α2-antiplasmin (a2- AP) were measured before, during operation and at 72h post-operatively. The serum creatinine levels before operation and at the 72 h after operation were also measured. Results The volume ratio of drainage to BSA in EACA group was significantly higher than that in the aprotinin group at 24 h after operation (P = 0. 019). However, there was no significant difference in the volumes of blood transfusion between two groups (P〉0. 05). Also no statistical difference in the concentrations of D-dimer and a2-AP were found between two groups whether preoperatively or at 72h post-operatively (P= 0. 960,0. 485), D-dimer and a2-AP of the aprotinin group were higher than those in the EACA group after aortic off-clamping (P = 0. 001,0. 000). There was no statistically difference of △CrCl72 in both groups (P〉0. 05). No patient with thrombosis or thromboembolism was detected in two groups.Conclusion Although the efficacy of EACA in reducing postoperative bleeding in cardiac valve replacement can not compare favorably with that of aprotinin, the blood transfusion volume would not increase when EACA is used introoperatively. Proper usage of EACA will not cause thrombosis and renal damage.
The body is at a hypo-coagulation status after the heart mechanic valve prosthesis replacement operation, and the incidence of anticoagulation complications is rather high because of that administration of warfarin may result in “anticoagulation vacuum” at an early stage. Moreover, the necessary application of other anticoagulation methods assisting the employment of warfarin have still not been scientifically normalized. Blood coagulation factor Ⅱ,Ⅶ, prothrombin fragment1+2 (F1+2 ), urine fibrimopeptide A (UFPA) , and International Normalized Ratio(INR), could exactly reflect the anticoagulation intensity 48-72 hours after the replacement operation,reasonable use of anticoagulant therapy as well as accurate and in-time monitoring methods is significant to reduce complications,elevate survival rate, and improve quality of life.
Objective To explore the affecting factors on sinus rhythm maintenance after electric cardioversion for patients with atrial fibrillation (Af) after cardiac valve replacement. Methods One hundred fifty two valvular disease patients with Af after cardiac valve replacement were randomized to 2 groups: Amiodarone group and control group (without anti arrhythmic drugs) after cardioversion. Af recurrence was observed during one year follow up. Results (1) No significant difference of Af recurrence betwe...
Transcatheter aortic valve replacement (TAVR) is the best treatment for severe aortic stenosis with high surgical risk, and low body weight significantly increased the risk of surgery and postoperative all-cause mortality. A case of elderly female diagnosed with severe aortic valve stenosis and extremely low body weight was presented in this article. Additionally, horizocardia and low located coronary orifice were also found in this patient, which markedly increased the risk and complexity of the TAVR procedure. During the operation, circulatory collapse occurred, and prosthetic valve was quickly released under emergency cardiopulmonary resuscitation. The operation was successful and the patient’s vital signs recovered soon. The follow-up showed that the patient was in good condition.
Objective To report the experiences of cardiac valve operation in children. Methods Cardiac valve operations were performed in 87 children who were 58 male and 19 female between age of 4 to 14 years (mean 10.2 years). Of the 87 patients, 36 underwent mitral valve replacement, 13 aortic valve replacement, 6 mitral and aortic valve replacement, 13 aortic valvuloplasty, and 19 mitral valvuloplasty. Associated cardiac lesions were simultaneously managed. Results Postoperative complications included low car...
Transcatheter aortic valve replacement (TAVR) has become a common theraputic option for aortic stenosis, but the evidence for precise anatomy for TAVR is accumulating. This paper presents the case of an 71-year-old female patient who had an extremely high risk of coronary obstruction due to both coronary ostia lying too low. The patient underwent TAVR with the help of coronary protection successfully. During the procedure, the patient was protected with wires only for both coronaries. After deployment, angiofluoroscopy suggested that chimney stenting should be applied for left coronary. The whole procedure was unenventful and both coronaries were seen.
Coronary artery obstruction is a rare but fatal complication of transcatheter aortic valve replacement. Although there is no accepted criteria to fully evaluate the occurrence of coronary artery obstruction, studies have revealed many important risk factors, and some preventive measures have also been found to reduce their occurrence. At present, transcatheter aortic valve replacement is in a stage of rapid development in China, but clinical medical workers’ knowledge of coronary artery obstruction as a complication still needs to be improved. This article discusses the incidence, risk factors, predictive assessment, prevention, treatment and prognosis of coronary artery obstruction complicated by transcatheter aortic valve replacement, so as to increase clinical medical workers’ understanding of this complication.
ObjectiveTo explore the feasibility and effectiveness of Commando procedure for mechanical valve dysfunction requiring reoperation. Methods The clinical data of patients who received Commando surgery (aortic/mitral curtain enlargement+valve replacement surgery) in the Department of Cardiovascular Surgery of Gaozhou People's Hospital from December 2021 to September 2022 were retrospectively analyzed. These patients who had undergone mechanical mitral or aortic valve replacement and then had mechanical valve dysfunction with mitral or aortic valve lesions requiring repeat combined valve replacement surgery were selected. Results Eleven patients were enrolled, including 2 males and 9 females, aged 63.63±11.64 years. All 11 patients successfully underwent the Commando operation, and were implanted with suitable artificial valves, among which the aortic valve size was 27.00±2.00 mm, and the mitral valve size was 27.72±3.13 mm. Cardiopulmonary bypass time was 195.81±39.29 min, aortic cross-clamping time was 121.81±28.60 min, mechanical ventilation time was 15.09±3.72 h, ICU stay time was 3.09±0.70 days, and total postoperative thoracic drainage volume was 417.18±68.65 mL. There was no perioperative death. ConclusionCommando procedure is a safe and effective method to perform combined valve operation for mechanical valve dysfunction. A larger artificial valve can be implanted during the procedure to obtain sound hemodynamic effects. In addition, for elderly patients, a suitable type of bioprosthetic valve can be implanted to improve the patient's quality of life. The early surgical effect is satisfactory, and the long-term impact needs further follow-up.
Transcatheter aortic valve replacement (TAVR) is a reasonable alternative for patients with severe aortic stenosis who are at a medium or high risk from surgery, and it’s gradually extended to low-risk groups. The safety of surgery is confirmed with the advancement of technology and the improvement of surgical instruments, but surgical complications are still common. Cardiovascular collapse is the leading cause of death during the surgery and not rare. This article reported a case of cardiovascular collapse during TAVR who were successfully rescued, while literature review on the causes and treatment of cardiovascular collapse were made.