Abstract: Compared with mitral valve replacement, there areseveral advantages in mitral valvuloplasty, so recently more and more sights are caught on mitral valve repair. According to different etiology, the surgeon can apply annuloplasty, triangular resection, quadrangular resection, replacement or transposition of chordae tendineae and so on to treat mitral regurgitation(MR). With the development of minimally invasive surgical technology, robotic mitral valve reconstruction evolve rapidly and percutaneous interventional therapy also commence from lab to bedside.We believe surgeons can repair MR safely and successfully in the majority of patients with proficiency in the basic techniques.
Objective To compare the early outcomes of domestic third-generation magnetically levitated left ventricular assist device (LVAD) with or without concomitant mitral valvuloplasty (MVP). Methods The clinical data of 17 end-stage heart failure patients who underwent LVAD implantation combined with preoperative moderate to severe mitral regurgitation in Fuwai Central China Cardiovascular Hospital from May 2018 to March 2023 were retrospectively analyzed. The patients were divided into a LVAD group and a LVAD+MVP group based on whether MVP was performed simultaneously, and early outcomes were compared between the two groups. Results There were 4 patients in the LVAD group, all males, aged (43.5±5.9) years, and 13 patients in the LVAD+MVP group, including 10 males and 3 females, aged (46.8±16.7) years. All the patients were successful in concomitant MVP without mitral reguragitation occurrence. Compared with the LVAD group, the LVAD+MVP group had a lower pulmonary artery systolic pressure and pulmonary artery mean pressure 72 h after operation, but the difference was not statistically different (P>0.05). Pulmonary artery systolic pressure was significantly lower 1 week after operation, as well as pulmonary artery systolic blood pressure and pulmonary artery mean pressure at 1 month after operation (P<0.01). There was no statistically significant difference in blood loss, operation time, cardiopulmonary bypass time, aortic cross-clamping time, mechanical ventilation time, or ICU stay time between the two groups (P>0.05). The differences in 1-month postoperative mortality, acute kidney injury, reoperation, gastrointestinal bleeding, and thrombosis and other complications between the two groups were not statistically significant (P>0.05). Conclusion Concomitant MVP with implantation of domestic third-generation magnetically levitated LVAD is safe and feasible, and concomitant MVP may improve postoperative hemodynamics without significantly increasing perioperative mortality and complication rates.
ObjectiveTo investigate the predictive value of right atrial myocardial fibrosis in the prognosis of isolated tricuspid regurgitation surgery after left heart valve surgery. MethodsThe patients who underwent tricuspid valvuloplasty by the same operator in Guangdong Provincial People's Hospital from April 2016 to August 2021 due to long-term isolated severe tricuspid regurgitation after left heart valve surgery were included in the study. According to the degree of right atrial myocardial fibrosis, the patients were divided into three groups: a mild group, a moderate group, and a severe group. The clinical data of these patients were compared and analyzed. ResultsA total of 75 patients were enrolled, including 16 males and 59 females with an average age of 57.0±8.4 years. There were 30 patients in the mild group, 29 patients in the moderate group and 16 patients in the severe group. In terms of the preoperative data, there were statistical differences in cardiac function grade, right atrial diameter, tricuspid incompetence area among the three groups (P<0.05). In terms of the postoperative data, there were statistical differences among the three groups in the cardiopulmonary bypass time, mechanical ventilation time, ICU monitoring time, complication rate and mortality (P<0.05). Further pairwise comparison showed that, compared with the mild group, the severe group had longer mechanical ventilation time (P=0.024), longer ICU monitoring time (P=0.003) and higher incidence of postoperative complications (P=0.024), while the moderate group had no statistical difference in all aspects (P>0.05); compared with the moderate group, the severe group had longer ICU monitoring time (P=0.021) and higher incidence of complications (P=0.006). ConclusionThe early outcome of tricuspid valvuloplasty in patients with isolated tricuspid regurgitation after left heart valve surgery with severe right atrial myocardial fibrosis is worse than that in the patients with mild and moderate fibrosis, suggesting that the degree of myocardial fibrosis in the right atrium can be a predictor of the effect of tricuspid regurgitation surgery and a judgement indicator of the surgery timing.
Functional tricuspid valve regurgitation (TR) is often secondary to left-sided valvular heart diseases. The precise diagnosis of TR degree and reasonable treatment can improve the long-term prognosis of patient. Now we believe that rectifying the TR during left cardiac valve surgery can prevent a further development of TR and avoid the reducing of the cardiac function for patients with moderate TR, tricuspid valve annulus diameter>40 mm in late diastole, tricuspid valve diameter/body surface area>21 mm/m2, and intraoperative tricuspid valve diameter >70 mm, especially for patients with atrial fibrillation and atrial enlargement. The use of prosthetic ring can effectively prevent recurrence of TR in long term and we should try to use hard or semihard "C" shape prosthetic ring as much as possible. The tricuspid valve replacement should be avioded because of its higher mortality.
Objective To investigate the effect of percutaneous balloon mitral valvuloplasty under echocardiographic guidance for patients with moderate to severe mitral stenosis during pregnancy. Methods A retrospective observational study was conducted to include pregnant women who were diagnosed with moderate to severe mitral stenosis and underwent percutaneous balloon mitral valvuloplasty under echocardiographic guidance in Fuwai Hospital from August 2018 to June 2022, and their baseline characteristics, surgical outcomes, echocardiographic results, and follow-up results were analyzed. Results A total of 3 pregnant women aged 30-35 years, with gestational age of 19-26 weeks, and New York Heart Association (NYHA) function class Ⅲ were included. All the procedures were successfully performed. The mitral valve orifice area increased from 0.9 cm2 preoperatively to 2.1 cm2 postoperatively. The mean transvalvular pressure gradient decreased from 15.0 mm Hg preoperatively to 6.7 mm Hg postoperatively. No perioperative adverse events occurred. The follow-up time ranged from 3 to 48 months. All patients delivered uneventfully and returned to normal life, with maternal-fetal safety. Conclusion Percutaneous balloon mitral valvuloplasty under echocardiographic guidance is a feasible and effective procedure for the treatment of patients with moderate to severe mitral stenosis in pregnancy, with satisfactory maternal-fetal outcomes.
Abstract: Objective To explore whether clinically mild functional tricuspid regurgitation should be addressed at the time of mitral valve repair (MVP) for moderate or severe mitral regurgitation due to myxomatous degeneration. Methods We retrospectively analyzed the outcomes of 135 patients with moderate or severemitral regurgitation due to myxomatous degeneration with mild functional tricuspid regurgitation. All patients were treated between January 1993 and March 2008 in the Department of Cardiothoracic Surgery of Changhai Hospital, the Second Military Medical University. We divided the patients into a MVP group (n=76) and a MVP+tricuspid valvuloplasty (TVP) group(n=59) according to whether they underwent combined TVP, and observed the perioperative mortality rate, degree of tricuspid regurgitation, and compared survival rate, and freedom from longterm moderate or severe tricuspid regurgitation after operation. Cox regression was used to analyzethe risk factors for longterm moderate or severe tricuspid regurgitation after operations. Results (1) There were no deaths during the perioperative period, and postoperative transthoracic echocardiography of all patients indicated that tricuspid regurgitation was mild or less. (2) Survival rate at 5 years, 10 years after operations in MVP group was 98.4%, 95.0%, respectively, and survival rate at 5 years, 10 years after operations in MVP+TVP group was 100.0%, 93.7%, respectively, and there was no significant difference in the survival rate after operations between the two groups(P=0.311), butthere was a significant difference in the freedom from longterm moderate or severe tricuspid regurgitation after operations between the two groups (P=0.040). Multivariate Cox regression showed that preoperative pulmonary artery pressure gt;30 mm Hg (95%CI 1.127 to 137.487, P=0.040 )and atrial fibrillation (95%CI 1.177 to 23.378, P=0.030) wereindependent risk factors for longterm moderate or severe tricuspid regurgitation afteroperations.Conclusion TVP is necessary for most patients undergoing MVP for moderate or severe mitral regurgitation due to myxomatous degeneration who have coexistent mild functional tricuspid regurgitation, especially those patients with preoperative pulmonary artery pressure gt;30 mm Hg or atrial fibrillation.
ObjectiveTo report the short-term outcomes of a standardized, simplified and reproducible strategy of mitral valvuloplasty (MVP), which was focused on leaflet foldoplasty and anatomic anomalies of congenital mitral regurgitation (MR).MethodsConsecutive 74 patients who underwent MVP by our standardized strategy in our institution from 2016 to 2018 were included retrospectively. There were 30 males and 44 females with a median age of 18.5 (6-146) months and weight of 15.4 (7-51) kg.ResultsAnatomic anomalies of MR included: (1) subvalvular apparatus: 72 (97.3%) patients with mal-connected chordae tendineae, 31 (41.9%) with absent chordae tendineae and 14 (18.9%) with fused or dysplastic papillary muscle; (2) leaflet: 10 (13.5%) patients with cleft of anterior leaflet, 61 (82.4%) with leaflet prolapse including 56 (91.8%) with anterior leaflet prolapse; (3) annulus: 71 (95.9%) patients with annular dilatation. Leaflet foldoplasty was performed in 61 (82.4%) patients with leaflet prolapse. All patients were successfully discharged and 4 (5.4%) patients were with moderate MR. The follow-up time was 22.0 (9.1-41.8) months. During the follow-up period, 3 patients had moderate MR and 1 patient had reoperation for severe MR. All patients were in normal cardiac function with a mean left ventricular ejection fraction of 66.0%±6.1%. In addition, the mean left ventricular end-diastolic dimension was 31.8±6.0 mm, which was significant smaller than that before the operation (t=6.090, P<0.000 1).ConclusionThe standardized leaflet foldoplasty with resection of mal-connected chordae tendineae and posterior annuloplasty technique is safe and feasible with favorable short-term outcomes in MR patients.
ObjectiveTo attempt an innovative mitral valvuloplasty by chained double stitching without shaping ring to repair ischemic mitral regurgitation (IMR) and to evaluate the clinical efficacy of this new procedure. MethodsWe retrospectively analyzed the clinical data of 12 patients with coronary artery disease and IMR underwent the innovative mitral valvuloplasty by chained double stitching without shaping ring in our hospital from August 2012 to December 2013. There were 10 males and 2 females at the mean age of 60±10 years ranging from 42 to 76 years. The cardiac functional parameters and condition of mitral regurgitation were compared among the period of preoperation, discharging and follow-up. ResultsTwelve patients were recovered and discharged from hospital with the New York Heart Association (NYHA) classification of heart function at class Ⅰ-Ⅱ. NYHA classification, grade of mitral regurgitation and regurgita- tion area were statistically improved on both the phase of discharge and follow-up compared with that of the pre-operation (P<0.05). Compared with preoperative left ventricular ejection fraction (LVEF), LVEF of discharging was statistically amelio- rative (P<0.05). And there was a statistic difference of NYHA classification of cardiac function in the phase of follow-up than that of discharging (P<0.05). ConclusionMitral valvuloplasty by chained double stitching without shaping ring is one reliable choice of treating IMR. The cardiac function and the living quality of the patients are statistically improved on the early stage and metaphase after operation, but long-term efficacy of this surgical procedure need be further assessed.
ObjectiveTo analyze the mid-long-term outcomes of surgical balloon valvuloplasty (SBV) for right ventricular decompression in the treatment of pulmonary atresia with intact ventricular septum (PA/IVS).MethodsClinical data of consecutive 91 patients who were diagnosed with PA/IVS and underwent SBV in our institution from January 2005 to December 2017 were retrospectively analyzed, including 52 (57.1%) males and 39 (42.9%) females. The median age was 3 months (1 d, 24 months) and the median weight was 4.1 (2.5, 12.0) kg.ResultsThe SBV was performed in all patients, and 62 of whom received other simultaneous surgeries, including ligation of patent ductus arteriosus (PDA, 33 patients), ligation of PDA with modified Blalock-Taussig shunt (23 patients), ligation of PDA with bidirectional Glenn shunt (6 patients). There was no early postoperative death. The median follow-up time was 8.8 (2.5, 13.4) years, 4 patients were lost. There were 7 (8.0%) deaths and 1 (1.1%) patient with a re-SBV for pulmonary stenosis. The one and a half ventricular repair was performed in 5 (5.7%) patients and Fontan procedure in 2 (2.3%) patients. In addition, the mean Z-value of tricuspid valve annulus was −1.7±1.5, which was significant bigger than that before the operation (t=5.587, P<0.001).ConclusionSBV via right ventricular outflow tract for right ventricular decompression in the treatment of PA/IVS is safe and reliable. The majority of patients can receive biventricular repair instead of single ventricular palliation by SBV with individually customized shunt.
Objective To analyze early and midterm outcomes and summarize clinical experience of mitral valve repair with artificial chordae for degenerative mitral regurgitation (MR). Methods Clinical data of 78 patients with degenerative MR who underwent mitral valve repair with Gore-Tex artificial chordae from October 2008 to December 2011 in General Hospita1 of Shenyang Military Command were retrospectively analyzed. There were 47 male patients and 31female patients with their age of 52.7±9.6 years,who all had degenerative MR. Operation techniques included simple GoreTex artificial chordae replacement in 15 patients,artificial chordae replacement plus quadrangular resection of the posterior leaflet in 58 patients,artificial chordae replacement plus quadrangular resection of the posterior leaflet and Sliding technique in 5 patients. One to three (2.15±1.05) Gore-Tex artificial chordae were used for each patient,and annuloplasty ring was used for all the patients. Thirty-nine patients underwent concomitant tricuspid valvuloplasty. Intraoperative transesophagealechocardiography showed none obvious MR in 62 patients,trivial MR in 13 patients and mild MR in 3 patients. All thepatients were followed up after discharge. Echocardiography was used to evaluate heart function and MR degree duringfollow-up. Results There was no in-hospital death in this group. Postoperative complications included sinus bradycardiain 5 patients,supraventricular tachycardia in 8 patients,late cardiac tamponade in 1 patient,and permanent pacemakerimplantation in 1 patient. Seventy patients were followed up for 1-2 years with the follow-up rate of 89.74% (70/78). Duringfollow-up,1 patient died of cerebral embolism 13 months after discharge,and all the other patients remained alive. There were 60 patients with NYHA classⅠand 9 patients with NYHA classⅡ. Echocardiography at 1 year after dischargeshowed that left atrial diameter,left ventricular end-diastolic diameter,left ventricular end-systolic diameter,and pulmonary artery systolic pressure were significantly smaller or lower than preoperative values (P<0.05),left ventricular ejection fraction (68.00%±7.00% vs. 55.00%±6.00%) and cardiac output were significantly higher than preoperative values(P<0.05),and MR degree (ratio of regurgitation beam area and left atrial area) was significantly reduced compared with preoperative MR degree (3.45%±5.56% vs. 39.55%±9.86%,P<0.05). No artificial chordae rupture was found. There were47 patients without MR and 22 patients with trivial MR during follow-up. Conclusion Gore-Tex artificial chordae replacement is a safe and effective surgical technique for the treatment of degenerative MR.