west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "wire" 53 results
  • Clinical analysis of CT-guided preoperative Hookwire localization of pulmonary nodules in 102 patients

    ObjectiveTo study the feasibility and safety of CT-guided preoperative Hookwire localization of pulmonary nodules in clinical application.MethodsClinical data of 102 patients who were scheduled to undergo surgical treatment for pulmonary nodules from June 2015 to April 2020 in the North Ward of Thoracic Surgery Department of Ruijin Hospital were retrospectively analyzed. There were 38 males and 64 females, aged 23-82 (53.2±12.8) years.ResultsAll 102 patients with pulmonary nodules underwent CT-guided preoperative Hookwire localization successfully, with a localization success rate of 100.0%. The localization time was 27.0 (11-67) min; the number of times to adjust the angle during the positioning process was 6.9 (3-14); the needle depth of the positioning needle was 41.5 (16.3-69.1) mm. A total of 48 (47.1%) patients had a small amount of bleeding in the lung tissue in the positioning area after positioning; 53 (51.9%) patients had a small amount of pneumothorax after positioning; 16 (15.7%) patients were found that the positioning needle completely shedded from the lung tissue in the subsequent surgery. One patient was transferred to open thoracotomy because of extensive dense adhesion in the thorax, and the remaining 101 patients were operated on under thoracoscopy. Postoperative pathology showed that 5 (4.9%) patients were adenocarcinoma in situ, 28 (27.5%) were microinvasive adenocarcinoma, 36 (35.3%) patients were invasive carcinoma and 32 (31.3%) patients were benign lesions. No patients had complications or adverse events related to preoperative positioning.ConclusionPreoperative CT-guided localization of Hookwire intrapulmonary nodules is safe and effective, and can meet the intraoperative localization needs of thoracic surgeons in most clinical situations, and is not inferior to other preoperative localization methods currently used in clinics.

    Release date:2022-01-21 01:31 Export PDF Favorites Scan
  • Application of 3D reconstruction and Hookwire to localize pulmonary nodules in thoracoscopic pulmonary segmentectomy

    ObjectiveTo investigate the clinical value of 3D CT combined with CT-guided Hookwire for localizing small pulmonary nodules in thoracoscopic pulmonary segmentectomy.MethodsFrom December 2017 to February 2019, 39 patients received thoracoscopic pulmonary segmentectomy in our hospital, including 14 males and 25 females with a mean age of 51.33±11.17 years. Before operation, we used Mimics Medical 20.0 to re-establish the anatomy of lung and locate the small pulmonary nodules with Hookwire guided by CT. Based on the position of Hookwire needle, 3D CT images and simulated surgical methods, thoracoscopic pulmonary segmentectomy was performed accurately.ResultsThe surgery was successfully completed in 39 patients without a transfer to open procedure. The mean operation time, mean intraoperative blood loss, mean postoperative hospital stay, mean thoracic tube drainage time were 148.97±28.56 min, 27.95±17.57 mL, 6.95±1.68 d, 4.21±1.95 d, respectively. Postoperative complications occurred in 5 patients (12.82%), including atrial fibrillation in 1, pulmonary infection in 1, chylothorax in 1, intrathoracic hemorrhage in 1 and pneumothorax in 1. All actual surgical margins were larger than 3.0 cm.ConclusionThe application of preoperative 3D CT combined with CT-guided Hookwire to localize small pulmonary nodules is helpful for accurate anatomical segmental resection of the lung, making the operation safe .

    Release date:2020-07-30 02:16 Export PDF Favorites Scan
  • CT-guided Hook-wire versus microcoil localization in the pulmonary nodules surgery: A systematic review and meta-analysis

    ObjectiveTo systematically evaluate the application effect of CT-guided Hook-wire localization and CT-guided microcoil localization in pulmonary nodules surgery. MethodsThe literatures on the comparison between CT-guided Hook-wire localization and CT-guided microcoil localization for pulmonary nodules were searched in PubMed, EMbase, The Cochrane Library, Web of Science, Wanfang, VIP and CNKI databases from the inception to October 2021. Review Manager (version 5.4) software was used for meta-analysis. The Newcastle-Ottawa Scale (NOS) was used to evaluate the quality of studies.ResultsA total of 10 retrospective cohort studies were included, with 1 117 patients including 473 patients in the CT-guided Hook-wire localization group and 644 patients in the CT-guided microcoil localization group. The quality of the studies was high with NOS scores>6 points. The result of meta-analysis showed that the difference in the localization operation time (MD=0.14, 95%CI −3.43 to 3.71, P=0.940) between the two groups was not statistically significant. However, the localization success rate of the Hook-wire group was superior to the microcoil group (OR=0.35, 95%CI 0.17 to 0.72, P=0.005). In addition, in comparison with Hook-wire localization, the microcoil localization could reduce the dislocation rate (OR=4.33, 95%CI 2.07 to 9.08, P<0.001), the incidence of pneumothorax (OR=1.62, 95%CI 1.12 to 2.33, P=0.010) and pulmonary hemorrhage (OR=1.64, 95%CI 1.07 to 2.51, P=0.020). ConclusionAlthough Hook-wire localization is slightly better than microcoil localization in the aspect of the success rate of pulmonary nodule localization, microcoil localization has an obvious advantage compared with Hook-wire localization in terms of controlling the incidence of dislocation, pneumothorax and pulmonary hemorrhage. Therefore, from a comprehensive perspective, this study believes that CT-guided microcoil localization is a preoperative localization method worthy of further promotion.

    Release date:2023-06-13 11:24 Export PDF Favorites Scan
  • Effectiveness of arthroscopic binding fixation using suture through single bone tunnel for posterior cruciate ligament tibial insertion fracture in adults

    Objective To explore the effectiveness of arthroscopic binding fixation using suture through single bone tunnel for posterior cruciate ligament (PCL) tibial insertion fractures in adults. Methods Between October 2019 and October 2021, 16 patients with PCL tibial insertion fractures were treated with arthroscopic binding fixation using suture through single bone tunnel. There were 11 males and 5 females with an average age of 41.1 years (range, 26-58 years). The fractures were caused by traffic accident in 12 cases and sports in 4 cases. The time from injury to operation ranged from 2 to 10 days with an average of 6.0 days. The fractures were classified as Meyers-McKeever type Ⅱ in 4 cases and type Ⅲ in 9 cases, and Zaricznyi type Ⅳ in 3 cases. There were 2 cases of grade Ⅰ, 7 cases of grade Ⅱ, and 7 cases of grade Ⅲ in the posterior drawer test. There were 3 cases combined with lateral collateral ligament injury and 2 cases with meniscus injury. The visual analogue scale (VAS) score, Lysholm score, International Knee Documentation Committee (IKDC) score, and knee range of motion were used to evaluate knee joint function. The posterior drawer test and knee stability tester (Kneelax 3) were used to evaluate knee joint stability. The X-ray films were used to evaluate fracture reduction and healing. Results All incisions healed by first intention after operation. There was no incision infection, popliteal neurovascular injury, or deep venous thrombosis of lower limbs. All patients were followed up 6-12 months, with an average of 10 months. X-ray films at 6 months after operation showed the fractures obtained bone union. There were 11 cases of grade 0, 4 cases of gradeⅠ, and 1 case of grade Ⅱin posterior drawer test, showing significant difference when compared with preoperative results (Z=23.167, P<0.001). The VAS score, Lysholm score, IKDC score, knee range of motion, and the results of Kneelax3 examination all significantly improved when compared with preoperative results (P<0.05). Conclusion For adult patients with PCL tibial insertion fractures, the arthroscopic binding fixation using suture through single bone tunnel has the advantages of minimal trauma, good fracture reduction, reliable fixation, and fewer complications. The patient’s knee joint function recovers well.

    Release date:2023-06-07 11:13 Export PDF Favorites Scan
  • A Digital System for Bioimpedance and Electrical Impedance Tomography Measurement System

    A digital system for bioimpedance and electrical impedance tomography (EIT) measurement controlled by an ATmega16 microcontroller was constructed in our laboratory. There are eight digital electrodes using AD5933 to measure the impedance of the targets, and the data is transmitted to the computer wirelessly through nRF24L01. The structure of the system, circuit design, system testing, vitro measurements of animals' tissues and electrical impedance tomography are introduced specifically in this paper. The experimental results showed that the system relative error was 0.42%, and the signal noise ratio was 76.3 dB. The system not only can be used to measure the impedance by any two electrodes within the frequency of 1-100 kHz in a sweep scanning, but also can reconstruct the images of EIT. The animal experiments showed that the data was valid and plots were fitting with Cole-Cole theory. The testing verified the feasibility and effectiveness of the system. The images reconstructed of a salt-water tank are satisfactory and match with the actual distribution of the tank. The system improves the effectiveness of the front-end measuring signal and the stability of the system greatly.

    Release date: Export PDF Favorites Scan
  • Application of thumb blocking technique with ulnar Kirschner wire threading for Gartland type Ⅲ supracondylar humerus fractures in children

    Objective To explore the effectiveness of thumb blocking technique through closed reduction of ulnar Kirschner wire threading in the treatment of Gartland type Ⅲ supracondylar humerus fractures in children. MethodsThe clinical data of 58 children with Gartland type Ⅲ supracondylar humerus fractures treated with closed reduction of ulnar Kirschner wire threading by thumb blocking technique between January 2020 and May 2021 were retrospectively analyzed. There were 31 males and 27 females with an average age of 6.4 years ranging from 2 to 14 years. The causes of injury were falling in 47 cases and sports injury in 11 cases. The time from injury to operation ranged from 24.4 to 70.6 hours, with an average of 49.6 hours. The twitch of ring and little fingers was observed during operation, the injury of ulnar nerve was observed after operation, and the healing time of fracture was recorded. At last follow-up, the effectiveness was evaluated by Flynn elbow score, and the complications were observed. Results There was no twitch of the ring and little fingers when the Kirschner wire was inserted on the ulnar side during operation, and the ulnar nerve was not injured. All children were followed up 6-24 months, with an average of 12.9 months. One child had postoperative infection in the operation area, local skin redness and swelling, and purulent secretion exudation at the eye of the Kirschner wire, which was improved after intravenous infusion and regular dressing change in the outpatient department, and the Kirschner wire was removed after the initial healing of the fracture; 2 children had irritation at the end of the Kirchner wire, and recovered after oral antibiotics and dressing change in the outpatient department. There was no serious complication such as nonunion and malunion, and the fracture healing time ranged from 4 to 6 weeks, with an average of 4.2 weeks. At last follow-up, the effectiveness was evaluated by Flynn elbow score, which was excellent in 52 cases, good in 4 cases, and fair in 2 cases, and the excellent and good rate was 96.6%. ConclusionThe treatment of Gartland type Ⅲ supracondylar humerus fractures in children by closed reduction and ulnar Kirschner wire fixation assisted with thumb blocking technique is safe and stable, and will not cause iatrogenic ulnar nerve injury.

    Release date:2023-02-13 09:57 Export PDF Favorites Scan
  • Feasibility study of Kirschner wire-fixation-cortical bone technique in treatment of intertrochanteric fracture

    Objective To explore the feasibility and effectiveness of maintaining the reduction of unstable intertrochanteric fractures by Kirschner wire-fixation-cortical bone technique. Methods Forty patients with intertrochanteric fracture [AO/Orthopaedic Trauma Association (AO/OTA) type 31-A2.2] admitted between May 2015 and January 2017 and requiring closed reduction and proximal femoral nail antirotation (PFNA) were randomly divided into trial group (intraoperative Kirschner wire-fixation-cortical bone technique group, 20 cases) and control group (conventional treatment group, 20 cases). There was no significant difference in general data of gender, age, side, body mass index, cause of injury, time from injury to operation between the two groups (P>0.05). The operation time, intraoperative blood loss, and intraoperative fluoroscopy times of the two groups were recorded; the reduction quality of fracture was observed according to the corresponding relationship between medial and anterior cortex (positive, neutral, and negative support) of intraoperative fluoroscopy proposed by ZHANG Shimin, and the stability of internal fixation and fracture healing were observed; Harris score was used to evaluate the recovery of hip function at 12 months after operation. Results In the trial group, 6 cases (30%) had 2 Kirschner wires implanted less than 4 times, 7 cases (35%) had 5-8 times, and 7 cases (35%) had 9 times or more. There was no significant difference in operation time and intraoperative blood loss between the two groups (P>0.05), but the blood transfusion volume and intraoperative fluoroscopy times in the trial group were significantly less than those in the control group (P<0.05). Both groups were followed up 13-21 months, with an average of 17 months. There was no complications such as wound infection, deep venous thrombosis of lower extremities, refracture, and internal fixation-related complications. The quality of intraoperative reduction in the trial group was significantly better than that in the control group (Z=–2.794, P=0.024). The Harris score of the trial group was significantly better than that of the control group at 12 months after operation (t=2.98, P=0.01). Conclusion The use of Kirschner wire-fixation-cortical bone technique during intertrochanteric fracture closed reduction and PFNA internal fixation surgery can effectively maintain the reduction effect, reduce the number of fluoroscopy, improve the reduction quality, reduce allogeneic blood input, obtain better hip function, and do not increase the operation time and intraoperative blood loss.

    Release date:2019-09-18 09:49 Export PDF Favorites Scan
  • Interpretation of 2021 China Chest Pain Center Quality Control Report

    The Medical Administration and Hospital Administration of the National Health Commission released the "2021 China Chest Pain Center Quality Control Report" in January 2022. This report analyzes the construction ratio of chest pain centers in the second-level and above medical institutions nationwide in 2021 and the construction of standard and basic chest pain centers, mainly from the way of coming to the hospital, symptom onset to first medical contact time, door to wire time, reperfusion therapy ratio, in-hospital mortality, proportion of discharges with medication recommended by the guidelines and average length and cost of hospital stay of ST-segment elevation myocardial infarction patients to comprehensively describe the current status of the construction of the national chest pain centers. This article interprets the report in detail by reviewing relevant literature.

    Release date:2022-11-22 02:01 Export PDF Favorites Scan
  • Treatment of Wehbe-Schneider typesⅠB and ⅡB bony mallet fingers with one-stage closed reduction and elastic compression fixation with double Kirschner wires

    Objective To investigate the effectiveness of one-stage closed reduction and elastic compression fixation with double Kirschner wires for Wehbe-Schneider types ⅠB and ⅡB bony mallet fingers. Methods Between May 2017 and June 2020, 21 patients with Wehbe-Schneider type ⅠB and ⅡB bony mallet fingers were treated with one-stage closed reduction and elastic compression fixation using double Kirschner wires. There were 15 males and 6 females with an average age of 39.2 years (range, 19-62 years). The causes of injury were sports injury in 9 cases, puncture injury in 7 cases, and sprain in 5 cases. The time from injury to admission was 5-72 hours (mean, 21.0 hours). There were 2 cases of index finger injury, 8 cases of middle finger injury, 9 cases of ring finger injury, and 2 cases of little finger injury. The angle of active dorsiflexion loss of distal interphalangeal joint (DIPJ) was (40.04±4.02)°. According to the Wehbe-Schneider classification standard, there were 10 cases of typeⅠB and 11 cases of type ⅡB. The Kirschner wire was removed at 6 weeks after operation when X-ray film reexamination showed bony union of the avulsion fracture, and the functional exercise of the affected finger was started. Results The operation time was 35-55 minutes (mean, 43.9 minutes). The length of hospital stay was 2-5 days (mean, 3.4 days). No postoperative complications occurred. All patients were followed up 6-12 months (mean, 8.8 months). X-ray films reexamination showed that all avulsion fractures achieved bony union after 4-6 weeks (mean, 5.3 weeks). Kirschner wire was removed at 6 weeks after operation. After Kirschner removal, the visual analogue scale (VAS) score of pain during active flexion of the DIPJ was 1-3 (mean, 1.6); the VAS score of pain was 2-5 (mean, 3.1) when the DIPJ was passively flexed to the maximum range of motion. The angle of active dorsiflexion loss of affected finger was (2.14±2.54)°, showing significant difference when compared with preoperative angle (t=52.186, P<0.001). There was no significant difference in the active flexion angle between the affected finger (79.52±6.31)° and the corresponding healthy finger (81.90±5.36)° (t=1.319, P=0.195). At 6 months after operation, according to Crawford functional evaluation criteria, the effectiveness was rated as excellent in 11 cases, good in 9, and fair in 1, with an excellent and good rate of 95.24%. Conclusion For Wehbe-Schneider typesⅠB and ⅡB bony mallet fingers, one-stage closed reduction and elastic compression fixation with double Kirschner wires can effectively correct the deformity and has the advantages of simple surgery, no incision, and no influence on the appearance of the affected finger.

    Release date:2022-05-07 02:02 Export PDF Favorites Scan
  • Clinical application of arthroscopic automatic reverse guide wire passer in posterior meniscus root reconstruction

    ObjectiveTo explore the application value and operation skills of arthroscopic automatic reverse guide wire passer (hereinafter referred to as wire passer) in the posterior meniscus root reconstruction. Methods Between August 2015 and December 2020, 36 patients with posterior meniscus root tears were admitted. There were 16 males and 20 females, with an average age of 46 years (range, 26-66 years). There were 15 cases of sports injury and 21 cases of degenerative injury. The disease duration was 3-180 days, with a median of 28 days. The posterior root of the medial meniscus was injured in 29 cases, and the posterior root of the lateral meniscus was injured in 7 cases. The preoperative Lysholm score of the knee joint was 47.6±3.9, and the International Knee Score Committee (IKDC) score was 39.3±3.0. The meniscus was sutured by using wire passer under arthroscopy. During operation, the suture operation was evaluated according to the self-defined evaluation standard. Lysholm score and IKDC score were used to evaluate knee joint function. Results All meniscuses were sutured successfully by using wire passer. The operation time of suture was 5-15 minutes, with an average of 10 minutes. According to the self-defined evaluation standard, the suture operation was scored as 0-10, with an average of 5. After operation, except for 2 cases of incision fat liquefaction, the incisions of the other patients healed by first intention. All patients were followed up 1-3 years, with an average of 1.5 years. The Lysholm score was 88.2±2.1 and the IKDC score was 51.7±2.3 at 1 year after operation, showing significant difference when compared with preoperative ones (P<0.001). Fifteen cases underwent MRI re-examination, the results showed that the continuity and integrity of the posterior root had been restored. Conclusion Under arthroscopy, the wire passer for the posterior meniscus root reconstruction has the advantages of simple operation, reliable suture quality, and shorter operation time.

    Release date:2022-03-22 04:55 Export PDF Favorites Scan
6 pages Previous 1 2 3 ... 6 Next

Format

Content