find Keyword "Finite element analysis" 15 results
  • Research on simulation and optimal design of a miniature magnetorheological fluid damper used in wearable rehabilitation training system

    The goal of this paper is to solve the problems of large volume, slow dynamic response and poor intelligent controllability of traditional gait rehabilitation training equipment by using the characteristic that the shear yield strength of magnetorheological fluid changes with the applied magnetic field strength. Based on the extended Bingham model, the main structural parameters of the magnetorheological fluid damper and its output force were simulated and optimized by using scientific computing software, and the three-dimensional modeling of the damper was carried out after the size was determined. On this basis and according to the design and use requirements of the damper, the finite element analysis software was used for force analysis, strength check and topology optimization of the main force components. Finally, a micro magnetorheological fluid damper suitable for wearable rehabilitation training system was designed, which has reference value for the design of lightweight, portable and intelligent rehabilitation training equipment.

    Release date:2023-02-24 06:14 Export PDF Favorites Scan
  • Biomechanical study on wing shaped titanium plate fixation of acetabular anterior column and posterior hemi-transverse fracture under multiple working conditions

    This article aims to compare and analyze the biomechanical differences between wing-shaped titanium plates and traditional titanium plates in fixing acetabular anterior column and posterior hemi-transverse (ACPHT) fracture under multiple working conditions using the finite element method. Firstly, four sets of internal fixation models for acetabular ACPHT fractures were established, and the hip joint stress under standing, sitting, forward extension, and abduction conditions was calculated through analysis software. Then, the stress of screws and titanium plates, as well as the stress and displacement of the fracture end face, were analyzed. Research has found that when using wing-shaped titanium plates to fix acetabular ACPHT fractures, the peak stress of screws decreases under all working conditions, while the peak stress of wing-shaped titanium plates decreases under standing and sitting conditions and increases under forward and outward extension conditions. The relative displacement and mean stress of the fracture end face decrease under all working conditions, but the values are higher under forward and outward extension conditions. Wing-shaped titanium plates can reduce the probability of screw fatigue failure when fixing acetabular ACPHT fractures and can bear greater loads under forward and outward extension conditions, improving the mechanical stability of the pelvis. Moreover, the stress on the fracture end surface is more conducive to stimulating fracture healing and promoting bone tissue growth. However, premature forward and outward extension rehabilitation exercises should not be performed.

    Release date:2025-04-24 04:31 Export PDF Favorites Scan
  • Evaluation of brain injury caused by stick type blunt instruments based on convolutional neural network and finite element method

    The finite element method is a new method to study the mechanism of brain injury caused by blunt instruments. But it is not easy to be applied because of its technology barrier of time-consuming and strong professionalism. In this study, a rapid and quantitative evaluation method was investigated to analyze the craniocerebral injury induced by blunt sticks based on convolutional neural network and finite element method. The velocity curve of stick struck and the maximum principal strain of brain tissue (cerebrum, corpus callosum, cerebellum and brainstem) from the finite element simulation were used as the input and output parameters of the convolutional neural network The convolutional neural network was trained and optimized by using the 10-fold cross-validation method. The Mean Absolute Error (MAE), Mean Square Error (MSE), and Goodness of Fit (R2) of the finally selected convolutional neural network model for the prediction of the maximum principal strain of the cerebrum were 0.084, 0.014, and 0.92, respectively. The predicted results of the maximum principal strain of the corpus callosum were 0.062, 0.007, 0.90, respectively. The predicted results of the maximum principal strain of the cerebellum and brainstem were 0.075, 0.011, and 0.94, respectively. These results show that the research and development of the deep convolutional neural network can quickly and accurately assess the local brain injury caused by the sticks blow, and have important application value for understanding the quantitative evaluation and the brain injury caused by the sticks struck. At the same time, this technology improves the computational efficiency and can provide a basis reference for transforming the current acceleration-based brain injury research into a focus on local brain injury research.

    Release date:2022-06-28 04:35 Export PDF Favorites Scan
  • FINITE ELEMENT STUDY ON ANTERIOR TRANSPEDICULAR SCREW-ARTIFICIAL VERTEBRAL BODY FIXATION IN LOWER CERVICAL SPINE

    Objective To compare the biomechanical properties of the anterior transpedicular screw-artificial vertebral body (AVB) and conventional anterior screw plate system (AP) in lower cervical spine by finite element study. Methods CT images (C1-T1) were obtained from a 38-year-old female volunteer. The models of intact C3-7 (intact group), AP fixation (AP group), and AVB fixation (AVB group) were established and analyzed by Mimics 14.0, Geomagic Studio 2013, and ANSYS 14.0 softwares. The axial force of 74 N and moment couple of 1 N·m were loaded on the upper surface and upper facet joint surfaces of C3. Under conditions of flexion, extension, lateral bending, and rotation, the Von Mises stress distribution regularity and maximum equivalent stree of AP and AVB groups were recorded, and the range of motion (ROM) was also analyzed of 3 groups. Results The intact model of lower cervical spine (C3-7) was established, consisting of 286 382 elements and 414 522 nodes, and it was successfully validated with the previously reported cadaveric experimental data of Panjabi and Kallemeyn. The stress concentrated on the connection between plate and screw in AP group, while it distributed evenly in AVB group. Between AP and AVB groups, there was significant difference in maximum equivalent stress values under conditions of 74 N axial force, flexion, extension, and rotation. AVB group had smaller ROM of fixed segments and larger ROM of adjacent segments than AP group. Compared with intact group, whole ROM of the lower cervical spine decreased about 3°, but ROM of C3, 4 and C6, 7 segments increased nearly 5° in both AP and AVB groups. Conclusion As a new reconstruction method of lower cervical spine, AVB fixation provides better stability and lower risk of failure than AP fixation.

    Release date:2016-08-31 10:53 Export PDF Favorites Scan
  • Finite element modeling and simulation study of solid-liquid biphase fiber-reinforced lumbar intervertebral disc

    The lumbar intervertebral disc exhibits a complex physiological structure with interactions between various segments, and its components are extremely complex. The material properties of different components in the lumbar intervertebral disc, especially the water content (undergoing dynamic change as influenced by age, degeneration, mechanical loading, and proteoglycan content) - critically determine its mechanical properties. When the lumbar intervertebral disc is under continuous pressure, water seeps out, and after the pressure is removed, water re-infiltrates. This dynamic fluid exchange process directly affects the mechanical properties of the lumbar intervertebral disc, while previous isotropic modeling methods have been unable to accurately reflect such solid-liquid phase behaviors. To explore the load-bearing mechanism of the lumbar intervertebral disc and establish a more realistic mechanical model of the lumbar intervertebral disc, this study developed a solid-liquid biphasic, fiber-reinforced finite element model. This model was used to simulate the four movements of the human lumbar spine in daily life, namely flexion, extension, axial rotation, and lateral bending. The fluid pressure, effective solid stress, and liquid pressure-bearing ratio of the annulus fibrosus and nucleus pulposus of different lumbar intervertebral discs were compared and analyzed under the movements. Under all the movements, the fluid pressure distribution was closer to the nucleus pulposus, while the effective solid stress distribution was more concentrated in the outer annulus fibrosus. In terms of fluid pressure, the maximum fluid pressure of the lumbar intervertebral disc during lateral bending was 1.95 MPa, significantly higher than the maximum fluid pressure under other movements. Meanwhile, the maximum effective solid stress of the lumbar intervertebral disc during flexion was 2.43 MPa, markedly higher than the maximum effective solid stress under other movements. Overall, the liquid pressure-bearing ratio under axial rotation was smaller than that under other movements. Based on the solid-liquid biphasic modeling method, this study more accurately revealed the dominant role of the liquid phase in the daily load-bearing process of the lumbar intervertebral disc and the solid-phase mechanical mechanism of the annulus fibrosus load-bearing, and more effectively predicted the solid-liquid phase co-load-bearing mechanism of the lumbar intervertebral disc in daily life.

    Release date:2025-08-19 11:47 Export PDF Favorites Scan
  • 3-D FINITE ELEMENT AND CLINICAL ANALYSES OF THE RECONSTRUCTION OF THE FIRST TO THIRD METATARSUS DEFECT WITH ILIUM

    Objective To investigate the effect of first to third metatarsus defect and the effect of reconstruction with ilium on foot function. Methods The first to third metatarsus defect was simulated in a 3D foot model and rebuilt by ilium. The maximal displacement and stress calculated by the method of finite elements were used as the index of estimation. Five cases treated from Mar. 1996 to Jan. 2003 with metatarsus defect rebuilding by free vascular iliac bone incorporating free flapwere evaluated. Results Foot function was affected largely by the defect of the first to third metatarsus. Compared with the normal foot, the maximal displacement was increased by 2.15 times and the maximal stress was increased by 2.12 times in 100% defected foot, and in 50%-defected foot maximal displacement and stress were increased by 1.65 times and 2.05 times respectively. Follow-up had been conducted for 1 to 2 years. All bones and flaps of the 5 cases survived (2 excellent, 2 good, and 1 passable) by function evaluation. Conclusion The first to third metatarsus defect should be repaired, and the method of transplanting iliac bone added by flap is effective. 

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
  • Effects of elastic modulus of the metal block on the condylar-constrained knee prosthesis tibial fixation stability

    Although metal blocks have been widely used for reconstructing uncontained tibial bone defects, the influence of their elastic modulus on the stability of tibial prosthesis fixation remains unclear. Based on this, a finite element model incorporating constrained condylar knee (CCK) prosthesis, tibia, and metal block was established. Considering the influence of the post-restraint structure of the prosthesis, the effects of variations in the elastic modulus of the block on the von Mises stress distribution in the tibia and the block, as well as on the micromotion at the bone-prosthesis fixation interface, were investigated. Results demonstrated that collision between the insert post and femoral prosthesis during tibial internal rotation increased tibial von Mises stress, significantly influencing the prediction of block elastic modulus variation. A decrease in the elastic modulus of the metal block resulted in increased von Mises stress in the proximal tibia, significantly reduced von Mises stress in the distal tibia, decreased von Mises stress of the block, and increased micromotion at the bone-prosthesis fixation interface. When the elastic modulus of the metal block fell below that of bone cement, inadequate block support substantially increased the risk of stress shielding in the distal tibia and fixation interface loosening. Therefore, this study recommends that biomechanical investigations of CCK prostheses must consider the post-constraint effect, and the elastic modulus of metal blocks for bone reconstruction should not be lower than 3 600 MPa.

    Release date:2025-08-19 11:47 Export PDF Favorites Scan
  • Biomechanical analysis of Magic screw fixation for acetabular posterior column fracture

    This study aims to analyze the biomechanical stability of Magic screw in the treatment of acetabular posterior column fractures by finite element analysis. A three-dimensional finite element model of the pelvis was established based on the computed tomography (CT) and magnetic resonance imaging (MRI) data of a volunteer and its effectiveness was verified. Then, the posterior column fracture model of the acetabulum was generated. The biomechanical stability of the four internal fixation models was compared. The 500 N force was applied to the upper surface of the sacrum to simulate human gravity. The maximum implant stresses of retrograde screw fixation, single-plate fixation, double-plate fixation and Magic screw fixation model in standing and sitting position were as follows: 114.10, 113.40 MPa; 58.93, 55.72 MPa; 58.76, 47.47 MPa; and 24.36, 27.50 MPa, respectively. The maximum stresses at the fracture end were as follows: 72.71, 70.51 MPa; 48.18, 22.80 MPa; 52.38, 27.14 MPa; and 34.05, 30.78 MPa, respectively. The fracture end displacement of the retrograde tension screw fixation model was the largest in both states, and the Magic screw had the smallest displacement variation in the standing state, but it was significantly higher than the two plate fixations in the sitting state. Magic screw can satisfy the biomechanical stability of posterior column fracture. Compared with traditional fixations, Magic screw has the advantages of more uniform stress distribution and less stress, and should be recommended.

    Release date:2022-10-25 01:09 Export PDF Favorites Scan
  • High stability enhanced ultrasonic microfluidic structure with flexible tip coupled bubbles

    Ultrasonic microfluidic technology is a technique that couples high-frequency ultrasonic excitation to microfluidic chips. To improve the issues of poor disturbance effects with flexible tip structures and the susceptibility of bubbles to thermal deformation, we propose an enhanced ultrasonic microchannel structure that couples flexible tips with bubbles aiming to improve the disturbance effects and the stability duration. Firstly, we used finite element analysis to simulate the flow field distribution characteristics of the flexible tip, the bubble, and the coupling structure and obtained the steady-state distribution characteristics of the velocity field. Next, we fabricated ultrasonic microfluidic chips based on these three structures, employing 2.8 μm polystyrene microspheres as tracers to analyze the disturbance characteristics of the flow field. Additionally, we analyzed the bubble size and growth rate within the adhering bubbles and coupling structures. Finally, we verified the applicability of the coupling structure for biological samples using human red blood cells (RBCs). Experimental results indicated that, compared to the flexible tip and adhering bubble structures, the flow field disturbance range of the coupling structure increased by 439.53% and 133.48%, respectively; the bubble growth rate reduced from 14.4% to 3.3%. The enhanced ultrasonic microfluidic structure proposed in this study shows great potential for widespread applications in micro-scale flow field disturbance and particle manipulation.

    Release date:2024-10-22 02:39 Export PDF Favorites Scan
  • APPLICATION OF THREE-DIMENSIONAL DIGITAL TECHNOLOGY IN KNEE ARTHROPLASTY

    ObjectiveTo review the recent progress in the application of three-dimensional digital technology in knee arthroplasty. MethodsThe relevant literature at home and abroad about the three-dimensional digital technology in the applications of knee arthroplasty in recent years was extensively reviewed. ResultsThe three-dimensional digital technology can obtain arthroplasty knee morphology and biomechanics, and can estimate preoperative planning osteotomy and the sizes of prostheses, so it can guide knee arthroplasty precisely. ConclusionThree-dimensional digital technology can reduce the operation error, improve the operation precision, and improve the effectiveness in knee arthroplasty.

    Release date:2016-10-21 06:36 Export PDF Favorites Scan